Microtek Bio-1000F User Manual

Gel Scanner User's Manual
www.microtek.com
2 Bio-1000F User's Manual
Preface
Copyright
Trademarks
Microtek, ScanMaker, ArtixScan, ScanWizard and ColoRescue are trademarks or registered trademarks of Microtek International, Inc. All other trademarks or
registered trademarks are the property of their respective holders. Specications,
software and hardware bundles are subject to change without notice. Not responsible for typographical errors.
Disclaimer
The contents of this manual have been checked carefully for accuracy, and every effort has been made to ensure that there are no errors. However, Microtek makes no guarantee as to the accuracy of the contents of this document and reserves the right to make changes to the contents without prior warning.
I49-005119 A1 October 2016
Microtek International, Inc. No. 6, Industry East Road 3, Science Based Industrial Park, Hsinchu, 30075, Taiwan
Tel: 886-3-5772155, Fax: 886-3-5772598, http://www.microtek.com
Bio-1000F User's Manual 3
FCC Compliance Statement
This equipment (Model: MFS-300L) has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
NOTE: A shielded Hi-Speed USB interface cable with ferrite core installed on the gel scanner connector end must be used with this equipment.
Caution: Changes or modications not expressly approved by the manufacturer
responsible for compliance could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
4 Bio-1000F User's Manual
Safety Precautions
Before using your scanner, read the following safety guides carefully, which detail the proper operation of the scanner and its accessories to prevent injuries or damage to users or equipment.
Meanings of Symbol Signs
This indicates hazardous situation which, if not paid attention, could result injury or damage to users or equipment.
This indicates hazardous situation which, if not paid attention, could result serious injury or death to users.
Power Supply:
Use a power source only with a power rating specied on the marking label.
Ensure to turn off the power of each device before connecting or
disconnecting the cables.
Insert the plug completely into the outlet, as a loose connection may cause arcing and result in re.
Ensure to hold the plug or connector to disconnect the cable; otherwise, if you pull the cable only, it may damage the core wire and result in re or
electric shock.
Place and route the power supply cord such that it is not likely to be walked
on or pinched by items placed upon or against them, paying particular attention to the cord near the power plugs, convenience receptacles, and at the point where it exits from the outlet.
When the scanner is left unattended and unused for long periods of time,
unplug it from the wall outlet.
Moving and Storing the Gel scanner:
Always ensure that the scanner is stored properly before shipping or moving
it. Quick stops, excessive force, and uneven surfaces may cause the product to overturn when moving.
Do not hit or drop the scanner. The scanner may be damaged if it receives a strong jolt, which may result in re or electric shock if the scanner is used
without being repaired.
Do not place the scanner on any slippery, slanted, or unstable surface. The
product may slide or fall, causing serious injury to people as well as serious damage to the product.
CAUTION
WARNING
Bio-1000F User's Manual 5
Do not use the scanner near water. Never spill liquid of any kinds on the
product, or it may result in electric shock or other hazards.
This scanner should be situated away from heat sources such as radiators, heat registers, stoves, or other products (including ampliers) that produce
heat.
Do not store the scanner in which it may be exposed to direct sunlight.
Using the Scanner
Before using the scanner, make sure the area of the glass surface is clear
from obstacles.
Maintenance and Service:
When the scanner is going to be cleaned, ensure to turn off the power of
each device and unplug the power cable from the AC outlet.
When you need a repair service, unplug the scanner from the power outlet and consult qualied service personnel.
When replacement parts are required, use replacement parts that are specied by the manufacturer or have the same characteristics as the
original parts.
For safety reasons, ensure to inspect the device before using it. In addition,
carrying out a regular inspection at least once a year.
Blue-LED Light
The blue-LED of the scanner is classied as Risk Group 1 (RG1), containing
very low risk. While the product is under a normal operation, the light
emitted from the blue-LED would not endanger human eyes
In order to protect your eyes, do not stare directly at the light of the blue­LED in any circumstances without using an appropriate shielding or lter
plate to unshield blue light.
When using the blue-LED to perform gel excising or observation, ensure that you use the lter plate came with your scanner package. Or, use an
appropriate shield or eye protector together with your scanner to avoid the damage from the direct blue light to your eyes.
For details on how to use the supplied lter plate, refer to section of this
manual titled ”Using the Filter Plate”.
6 Bio-1000F User's Manual
Table of Contents
Preface ................................................................................................2
Safety Regulations ..............................................................................3
FCC Compliance Statement ................................................................ 3
Regulations ...................................................................................... 4
Safety Precautions ............................................................................ 5
Knowing about Your Gel scanner ........................................................9
Features of the Bio-1000F .................................................................. 9
System Requirements ...................................................................... 10
Taking a Closer Look ....................................................................... 11
Front/Open View ....................................................................... 11
Rear View ................................................................................ 12
Initial Setup .......................................................................................13
Step 1: Unpacking Package Contents ................................................ 14
Step 2: Installing the Software.......................................................... 15
Step 3: Unlocking the Scanner .......................................................... 16
Step 4: Connecting the Scanner ........................................................ 18
To the Power Cord .................................................................... 18
To the Hi-Speed USB Cable ........................................................ 17
Digitizing a Gel .................................................................................. 18
Positioning a Gel ............................................................................. 18
Scanning a Gel ............................................................................... 19
Excising or Observing a Gel...............................................................21
Using the Filter Plate ....................................................................... 21
Knowing the MiBio Fluo Software Better ..........................................23
Launching MiBio Fluo ....................................................................... 23
Exiting MiBio Fluo ........................................................................... 23
Main Control Panel .......................................................................... 24
Image Capture Button ................................................................ 26
Light Up Button ........................................................................ 26
Settings Button ......................................................................... 28
File's Saving Location .......................................................... 28
Gray Mode ......................................................................... 29
Resolution .......................................................................... 29
Stain Prole........................................................................ 29
Bio-1000F User's Manual 7
File Naming ........................................................................ 30
File Format ......................................................................... 31
Show Warning Message(s) ................................................... 31
Care and Cleaning .............................................................................32
Cleaning the Glass Surfaces ............................................................. 32
Maintenance ......................................................................................33
Appendix ...........................................................................................34
Troubleshooting .............................................................................. 34
Specications ................................................................................. 35
8 Bio-1000F User's Manual
Bio-1000F User's Manual 9
Knowing about Your Gel scanner
The Bio-1000F is a gel scanner which is specically designed for the use of
scanning with global EtBr-alternative stain brands.
With a patented optical design, sensitive CCD and exible software, Bio-1000F is capable to capture faint uorescence, which demonstrates more sensitive and better performance than UV- and other blue-LED based gel imaging systems. Besides, equipped with blue-LED and lter plate, Bio-1000F provides multilevel
protections from direct damages to eyes and skins, making safer and friendlier to both researchers and environment.
Features of the Bio-1000F
The Bio-1000F comes with several important features, including the following:
High sensitivity of uorescence — Bio-1000F goes perfectly with global EtBr-
alternative stain brands. The highest sensitivity of Bio-1000F can reach to
0.008 ng/μl.
Space-saving compact design — The modern and compact design of the Bio-
1000F makes it perfect for small rooms and workshops, saving desk space and keep storage space neat and clean.
Hi-Speed USB connecting port — High-Speed USB (USB 2.0) is capable of
480 Mbps data transfer, provides plug-and-play connectivity for a hassle-free installation.
Microtek MiBio Fluo software — The easy and friendly user interface of
MiBio Fluo stores gel images in a computer readable format, offering an easy and quick access and management.
Easy to operate, clean and maintain — The Bio-1000F requires virtually no
routine maintenance and no daily cleaning, which is ideal for busy working environments.
10 Bio-1000F User's Manual
System Requirements
In order to use your Bio-1000F, your computer must satisfy the following system requirements:
CD-ROM drive (for installing software)
Color display with 24-bit color output capability
512 MB RAM or above
300 MB HDD or above
Pentium IV PC or higher with Hi-Speed USB (USB 2.0)
Microsoft Windows XP, Windows 7, Windows 8 or Windows 10
Bio-1000F User's Manual 11
Taking a Closer Look
Open View
No. Names of Parts Functions of Parts
1 Holes (2) Used to hang up a lter plate when lighting up a blue-LED
for a gel excising or observation.
2 Scanner Lid The top cover of the scanner.
3 Rear Glass Surface The place where the scanner makes a calibration.
4 Red Arrow Mark Used to align a gel properly.
5 Front Glass Surface The place to put a gel for scanning, excising or observing.
Loading...
+ 25 hidden pages