SENKO Auto Open Heat Press Manual
Model No.:SENKO-15A/20A
CONTENTS
I. Assembly Drawing -----------------------------------------------------------------------------------1
II. Technical Parameters ------------------------------------------------------------------------------2
III. Operation Process -------------------------------------------------------------------------------3-4
IV. Maintenance ------------------------------------------------------------------------------------------5
V. Trouble Shooting For Transfer Print Quality------------------------------------------------5
VI. Circuit Diagram -------------------------------------------------------------------------------------6
VII. Explosion View ----------------------------------------------------------------------------------7-8
I. Assembly Drawing
II. Technical Parameters
1. Model No.: SENKO-15A/20A
2. Machine Dimensions: 780*680*400mm
3. Heat Platen Size : 15’’X15’’, 16’’x20’’ (38*38cm,40*50cm)
4. Printable Articles Max Size: 400*500*10mm
5. Voltage: 220V/1Phase; 120V/1Phase
6. Power: 220V/1.8KW; 120V/1.2KW
7. Recommend Setting: 30~280s; 180~200°C
Time Range: 0~999s
Maximum Temp: 225 C°
8. Packing size:102*64*82cm
9. Gross weight: 81.06kg
○7Electrical Parts Bracket
III. Operation Process
1. Set temperature required
Turn on power switch, temperature
light is ON. The digital display shows
.
Press button, the light is
on (C denotes Celsius). Press
arrows “△” or “▽” to select “℃” or
“℉” (F denotes Fahrenheit)
according to your habits.
Press button, the temp light
is ON. Press Up “△” or Down “▽”
button to set temperature according
to different transfer material.
(Normally 180℃~200℃)
Note: Temperature will be shown on
the controller only after it reached to
100℃, it’s normal that there is no
temperature shows right after the
setting.
Press button after the
temperature setting and the
time light is ON. Press Up “△” or
Down “▽” button to set time
according to different transfer
material.
Press button after time setting;
the display shows the temperature
starts to rise. “CD-L” shows the time
counting down during your transfer.
If there is a difference between the
actual temperature and temperature
shows on the controller, you can
use P5 mode to calibrate the
difference.
For example, when actual heat
platen temperature is 180 °C but the
display shows 200°C, press
button for 5 seconds to enter the P5
mode. When enter P5 mode,
press UP button “△”to set to 20,
and then press button again
for 5 seconds return to operation
mode. In the contrast, when actual