microSYST miline FTL10 Operating Manual

Page 1
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de
miline FTL10
LED Multifunction Clock
Operating Manual
Page 2
miline FTL10
LED Multifunction Clock
Page 2
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de
Index
1 SAFETY INSTRUCTIONS 3
2 SCOPE OF DELIVERY 3
3 MOUNTING 4
4 BRIEF DESCRIPTION 5
5 START-UP 6
6 OPERATING MODE 7
7 CONFIGURATION 8
7.1 Display Settings 9
7.2 Channel Setting Multifunction Sensor (optional) 10
7.3 DCF Setting (optional) 10
8 DECLARATION OF CONFORMITY 11
9 GUARANTEE 12
10 TECHNICAL DATA 13
11 DIMENSIONS 15
Page 3
miline FTL10
LED Multifunction Clock
Page 3
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de
1 Safety Instructions
Please read these instructions carefully and follow all instructions and safety infor­mation. Non-observance could result in injury to persons and / or damage the unit.
Use only the included AC adapter. Check for tight fit in the socket. Wobbly plugs or receptacle may cause a fire. If you want to disconnect power, do not unplug the cord, but disconnect the AC adapter.
Connect the display to an easily accessible power outlet (230 V / 50 Hz), which is located near the installation site.
Do not touch the plug contacts with metallic, sharp or wet objects. Please do not open the housing of the display. Refer servicing to an expert, as this
usually leads to the loss of your warranty claims. Protect the display from moisture, water, steam and aggressive fluids! Do not install near strong magnetic fields. The reception may be impaired.
2 Scope of Delivery
Please check the product’s package for completeness: Standard:
Multifunction clock including angle bracket AC adapter Remote control Batteries for the remote control
Option:
Multifunction Sensor Batteries for the multifunction sensor
Page 4
miline FTL10
LED Multifunction Clock
Page 4
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de
3 Mounting
LED Multifunction Clock “miline FTL10”
The adjustable bracket on the back allows wall or ceiling mounting. Examples:
Multifunction Sensor “MFS10” (optional)
The integrated antenna must be in horizontal position for DCF77-reception. Please regard for a correct position in case of wall mounting. The sensor is always horizontal, if it’s mounted on the ceiling.
Example:
Antenna
Page 5
miline FTL10
LED Multifunction Clock
Page 5
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de
4 Brief Description
The "miline FTL10" display with 120 mm character height and white LEDs is de­signed for use in indoor and semi-outdoor areas. The standard version of this display alternately shows time and date (user adjustable, based on quartz) in an adjustable change interval from 1 to 30 seconds.
Optionally, the standard model can be upgraded to a multi-function display. An external wireless sensor “MFS10” provides DCF77 radio clock, temperature and humidity sensor.
The implemented LED dot matrix technology and automatic brightness adjust­ment to the ambient light serve for a readability up to an angle of ±60°.
A variable wall bracket on the back of the anodised aluminium profile housing al­lows both wall and ceiling mount.
In case of power failure, the internal battery is able to save time and date up to 10 years. Settings on the display are done with the included remote control.
Remote Control for Configuration
Multifunction Sensor “MFS10“ (optional)
IR
433 Mhz
LED Multifunction Clock “miline FTL10“
Page 6
miline FTL10
LED Multifunction Clock
Page 6
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de
5 Start-Up
Display without Multifunction Sensor
Plug the AC adapter.  Open the remote control and insert the batteries.  Set time and date (see chapter “Configuration“).
Display with Multifunction Sensor
Plug the AC adapter.  Open the remote control and insert the batteries.  Open the multifunction sensor and insert the batteries. At this, the green function
LED will flash up for one second.
Regarding the synchronisation settings, see chapter "Configuration".
Page 7
miline FTL10
LED Multifunction Clock
Page 7
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de
6 Operating Mode
According to expansion stage, the display shows the following measures:
Time
Date
Temperature (optional, with “MFS10”)
Relative humidity (optional, with “MFS10”)
Low Battery:
If the batteries in the sensor "MFS10" are too low, the display shows a battery icon instead of temperature and humidity level.
Page 8
miline FTL10
LED Multifunction Clock
Page 8
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de
7 Configuration
The display is configured with the included universal remote control.
Button
Function
On-off switch for the display
Setup mode
VOLUME +/-
Digit selection (date / time) and menu navigation
CHANNEL +/-
Value adjustment
Page 9
miline FTL10
LED Multifunction Clock
Page 9
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de
7.1 Display Settings
Press button for 2 seconds until the display’s hour digit starts to flash, then use the navigation keys to select the desired menu item. The values can be changed with the corresponding buttons.
Menu Navigation (button “VOLUME +“):
Hours
Time setting For systems with multi-function sensor, DCF77 defaults always take precedence.
Minutes
Day
Date setting For systems with multi-function sensor, DCF77 defaults always take precedence.
Month
P1 - Display time
Appearance of the single measures: 00: deactivated
01: activated Standard without „MFS10“: P1 + P2 = 01
P3 + P4 = 00 Standard with „MFS10“: P1...P4 = 01
P2 - Display date
P3 - Display temperature (optional with “MFS10”)
P4 - Display humidity (optional with “MFS10”)
P5 - Alternation interval
Time for displaying a measure. Setting range: 01 to 30 seconds Standard: 05
P6 - Maximum brightness
This menu item is shown with the current maxi­mum brightness. Setting range: 01 to 99 Standard: 99
P7 - Flashing colon (at the time)
Setting range: 00 / 01 00: deactivated 01: activated Standard: 01
P8 - Radio channel
Selection of the radio channel Setting range: 01 to 06 Standard: 01
P9 - Request DCF77 reception
DCF77 status (description see next page)
The settings are saved with the button . After that, setup mode is left.
Page 10
miline FTL10
LED Multifunction Clock
Page 10
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de
7.2 Channel Setting Multifunction Sensor (optional)
6 radio channels are provided for communication between the sensor and display. This allows the operation of up to 6 display systems in the same transmission range.
It may be necessary to synchronize the multifunction sensor with the display.
Please proceed as follows:
Select desired radio channel (01 to 06) with display’s menu item P8. Open the multi-function light sensor and press the button on the board about 1
second until the green LED is lit.
After synchronisation, this LED goes off and the display will quit setup mode
automatically.
After 20 seconds at the earliest, current data are shown.
7.3 DCF Setting (optional)
You can force an attempt for DCF77 reception with menu item P9 to find the optimal position for the multifunction sensor. Please stay in this menu and observe the status message. If the reception is suffi­cient, you get the following sequence (within max. 5 minutes):
Status message
Meaning
0
Attempt for reception started
1
DCF signal identified
2
Data reception
3
Time and date have been updated
The DCF signal is not sufficient, if the status message changes between “1” and “2”.
At status “0”, no reception is possible.
Page 11
miline FTL10
LED Multifunction Clock
Page 11
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de
8 Declaration of Conformity
EU-Konformitätserklärung
EU Declaration of Conformity
Produktbezeichnung: miline
Product name:
Typenreihe: miline FTL 10
Type code:
Hersteller: microSYST Systemelectronic GmbH
Manufacturer: Am Gewerbepark 11 92670 Windischeschenbach
Das bezeichnete Produkt stimmt mit der folgenden Europäischen Richtlinie überein:
We herewith confirm that the above men­tioned product meets the requirements of the following standard:
Die Übereinstimmung des bezeichneten Produk­tes mit den Vorschriften der angewandten Richt­linie(n) wird nachgewiesen durch die Einhaltung folgender Normen / Vorschriften:
The conformity of the product described above with the provisions of the applied Directive(s) is demon­strated by compliance with the following standards / regulations:
Richtlinien / Directives
Europäische Norm / Standard
EMV Richtlinie
EMC Directive
2014/30/EU
EN61000-6-2:2005
EN61000-6-3:2007 +A1:2011
RoHS Richtlinie
RoHS Directive
2011/65/EU
EN50581:2012
Windischeschenbach, 11.12.2017
Manuel Raß Geschäftsführer / General Manager
Page 12
miline FTL10
LED Multifunction Clock
Page 12
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de
9 Guarantee
The display is guaranteed for the duration specified in the “General
Terms and Conditions” regarding manufactured products and services
rendered for the electrical industry against defects which existed at the time the device was delivered to the buyer.
The device is subject to technical change without notice. Errors and omissions are accepted. No claims can be honored for the shipment of a new product. The buyer is required to make notification of defects within 2 weeks after identification of such. Non-observance of notifica­tion requirements is equated with acceptance of the defect.
Defects and their symptoms must be described as accurately as possi­ble in order to allow for reproducibility and elimination. The buyer must provide for access to all required and/or useful information regarding de­fects at no charge, as well as to the affected devices, and must make all of the required data and machine time available free of charge.
The guarantee does not cover defects, which result from non­observance of the prescribed conditions of use, or from improper han­dling.
If the device has been placed at the disposal of the buyer for test pur­poses and has been purchased subsequent to such testing, both parties
agree that the product is to be considered “used” and that it has been
purchased “as is”. No guarantee claims may be made in such cases.
The “General Terms and Conditions” regarding manufactured products
and services rendered for the electrical industry apply as well.
Page 13
miline FTL10
LED Multifunction Clock
Page 13
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de
10 Technical Data
LED Multifunction Clock “miline FTL10”
Display type: LED dot matrix Application range: indoor and semi-outdoor (without direct solar radiation) Angle of radiation: ±60° Character height: 120 mm Reading distance: up to approx. 50 m Display colour: white Light intensity: > 2000 cd/sqm Brightness control: automatically; maximum value manually adjustable View: single-sided Display: time: hours + minutes, date: day + month; With optional multifunction sensor: temperature: -40 to +60 °C; humidity: h 01 to 99 % Clock preciseness: ±1 min. / year from 0 to +40 °C ambient temperature; DCF-exact (“radio controlled clock“) via optional multifunction sensor Interfaces: IR interface; 433 MHz radio interface (6 channels) Operating voltage: 15 to 40 VDC; 230 VAC via external power supply plug Power consumption: approx. 10 W Housing: anodised aluminium Housing dimensions: see next chapter Housing colour: black Mounting: wall or ceiling mounting; inclination adjustable Protection: IP54 Operating temperature: -20 to +60 °C Storage temperature: -25 to +70 °C Equipment: multifunction sensor “MFS10“
Multifunction Sensor “MFS10”
Interface: 433 MHz radio interface (6 channels) Sensors: temperature sensor; humidity sensor Aerial: DCF77-reception (“radio controlled clock”) Features: temperature measurement; humidity measurement; 2 x a day DCF77-reception; communication to “miline FTL10“ via radio (433 MHz) Number of displays per multifunction sensor: 10 pieces with parallel operation Range: max. 50 m, depending on ambient conditions Operating voltage: 3 VDC (via 2 x batteries AA) Housing: plastic Housing dimensions: see next chapter Housing colour: grey Mounting: wall or ceiling mounting Protection: IP65 Operating temperature: -40 to +60 °C Storage temperature: -40 to +60 °C
Page 14
miline FTL10
LED Multifunction Clock
Page 14
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de
Maximum T-tolerance
Maximum RH-tolerance (at 25 °C)
ΔT (°C)
Temperature °C
ΔRH (%RH)
Relative Humidity (%RH)
Page 15
miline FTL10
LED Multifunction Clock
Page 15
microSYST Systemelectronic GmbH, Am Gewerbepark 11, 92670 Windischeschenbach +49 9681 91960-0, +49 9681 91960-10, info@microsyst.de, www.microsyst.de
11 Dimensions
LED Multifunction Clock “miline FTL10”
Multifunction Sensor “MFS10”
Loading...