Microsonic crm+25/D/TC/E, crm+35/D/TC/E, crm+130/D/TC/E, crm+340/D/TC/E, crm+600/D/TC/E Instruction Manual

T2
T1
T2
T2
T1
T1 + T2
Set detect distance in mm or cm
For single detect point press T2 until »- - -« is displayed
Choose » « for NCC or » « for NOC
T1
T2
For window mode operation set far detect point in mm or cm
T1 + T2
Press T1 and T2 simultaneously for about 3 s until welcome message has passed
T1 + T2
T2
T1
T1 + T2
T1 + T2
T1 + T2
T2
T1
Set switched output
Ready
Start here
Set sensor parameters alternatively numerically using LED-display...
Product description
The crm+sensor with one switched output
measures the distance to an object within the detection zone contactless. Depen­ding on the adjusted detect distance the switched output is set.
The ultrasonic transducer surface of the
crm+sensors is laminated with a PEEK film. The transducer itself is sealed against the housing by a PTFE joint ring. This composition ensures a high resitance against many aggressive substances.
All settings are done with two push-but-
tons and a three-digit LED-display (TouchControl).
Light emitting diodes (three-colour LEDs)
indicate the switching status.
The output functions are changeable
from NOC to NCC.
The sensors are adjustable manually using
the numerical LED-display or may be trai­ned using Teach-in processes.
Useful additional functions are set in the
Add-on-menu.
Using the LinkControl adapter (optional
accessory) all TouchControl and additio­nal sensor parameter settings may be made by a Windows-Software.
Safety Notes
Read the operating instructions prior to
start-up.
Connection, installation and adjustment
works may only be carried out by expert personnel
.
No safety component in accordance with
the EU Machine Directive.
The crm+ sensors indicate a blind zone, in which the distance cannot be measured. The operating range indicates the distance of the sensor that can be applied with normal re­flectors with sufficient function reserve. When using good reflectors, such as a calm water surface, the sensor can also be used up to its maximum range. Objects that strongly absorb (e.g. plastic foam) or diffusely reflect sound (e.g. pebble stones) can also reduce the defined operating range.
Synchronisation
If the assembly distances shown in Fig.1 for two or more sensors are exceeded the inte­grated synchronisation should be used. Con­nect Sync/Com-channels (pin 5 at the units re­ceptable) of all sensors (10 maximum).
Fig. 1: Assembly distances, indicating syn-
chronisation/multiplex
Multiplex mode
The Add-on-menu allows to assign an indivi­dual address »01« to »10« to each sensor connected via the Sync/Com-channel (Pin5). The sensors perform the ultrasonic measure­ment sequentially from low to high address. Therefore any influence between the sensors is rejected. The address »00« is reserved to synchronisa­tion mode and deactivates the multiplex
0.35 m
0.40 m
2.50 m
2.50 m
1.10 m
2.00 m
8.00 m
18.00 m
4.00 m
30.00 m
mode. (To use synchronised mode all sensors must be set to address »00«.)
Assembly instructions
Assemble the sensor at the installation lo-
cation.
Plug in the connector cable to the M 12
connector.
Fig. 2: Pin assignment with view onto sensor
plug and colour coding of the microsonic connection cable
Start-up
crm+ sensors are delivered factory made with the following settings:
Switched output on NOCDetecting distance at operating range
1 3
colour
+U
B
-U
B
brown
blue 4 2 5
D
-
black
white
Sync/Com. grey
1
5
2
34
Measurement range set to maximum ran-
ge
Set the parameters of the sensor manually or use the Teach-in procedure to adjust the de­tect points.
Fig. 3: TouchControl
Operation
crm+sensors work maintenance free. Small amounts of dirt on the surface do not influ­ence function. Thick layers of dirt and caked­on dirt affect sensor function and therefore must be removed.
Note
As a result of the design the assembly of
PEEK film and PTFE joint ring is not gas­proof.
The chemical resistance has to be tested
experimentally if necessary.
crm+ensors have internal temperature
compensation. Because the sensors heat up on their own, the temperature com­pensation reaches its optimum working point after approx. 30 minutes of operati­on.
During normal mode operation, a yellow
LED D2 signals that the switched output has connected.
During normal mode operation, the mea-
sured distance value is displayed on the LED-indicator in mm (up to 999 mm) or cm (from 100 cm). Scale switches auto­matically and is indicated by a point on top of the digits.
During Teach-in mode, the hysteresis
loops are set back to factory settings.
If no objects are placed within the detec-
tion zone the LED-indicator shows »- - -«.
If no push-buttons are pressed for 20 se-
conds during parameter setting mode the made changes are stored and the sensor returns to normal mode operation.
You can lock the key pad to provide in-
puts, see »Key lock and factory setting«.
You can reset the factory settings at any
time, see »Key lock and factory setting«.
Show parameters
Tapping push-button T1 shortly during nor­mal mode operation shows »PAr« on the LED-display. Each time you tap push-button T1 the actual settings of the switched output are shown.
Instruction manual
crm+ Ultrasonic Sensors with one switched output
c
m m m %
T 1 D 1 D 2 T
2
measuring range
LED D1 and D2
3-digit LED-display
Push-buttons T1 and T2
crm+25/D/TC/E crm+35/D/TC/E crm+130/D/TC/E crm+340/D/TC/E crm+600/D/TC/E
2014/30/EU
...or with the Teach-in procedure
Adjust detect point
Place object at position
Press T2 until »d« is shown
Current measu­ring value
Press T2 until »End« is shown
Adjust window mode
Place object at position
Press T2 until »d« is shown
Place object at position
Current measu­ring value
Press T2 until »End« is shown
Current measu­ring value
Adjust two-way reflectiv bar-
rier
Place reflector at position
Set NOC/NCC
Press T2 until »d« is shown
Current measu­ring value
Press T2 until countdown passed from »- 8 -« to »- 0 -« and NOC or NCC symbol is
displayed
Press T2 until countdown passed from »- 8 -« to »- 0 -«
and »End« is displayed
To change output function
press T2
Press T1 and T2 simultaneous-
ly until »End« is displayed
Symbol NOC or NCC
Symbol NOC or NCC
Normal mode operation
Usefull additional functions in Add-on menu (for experienced users only, settings not required for standard applications)
T1 + T2
T1
T2
T1 + T2
Press T1 and T2 simultaneously for about 13 s until »Add« is shown in the LED-display
T1 + T2
T2
T1
Start here
T2
T1
T1 + T2
Ready
»C01«: Display bright
»C02«: Display dim­med
»C03«: Display off
To optimize multi­plex speed the hig­hest sensor address may be set.
Setting range »01« to »10«
»F00«: no filter »F01«: standard fil-
ter »F02«: averaging fil-
ter »F03«: foreground
filter »F04«: background
filter
Defines the strength of the chosen filter.
»P00«: weak filter up to
»P09«: strong filter
Affects the size of the detection zone.
»E01«: high »E02«: standard »E03«: slight
Minimum value: blind zone
Maximum value: ne­arwindow limit - 1
Low power mode
Measurement filter Filter strength Foreground
suppression
Multiplex mode
device addressing
Multiplex mode highest address
»00«: synchronisati­on
»01« to »10«: sensor address for multi­plex mode
»oFF«: synchronisati­on deactivated
Minimum value: sen­sor-distant window margin
Maximum value: 999 mm for crm+25/... and crm+35/... and 999 cm for all other typs
Measurement range Calibration
display
Detection zone
sensitivity
Put plane reflector vertically disposed in front of sensor: in an exact distance of 250 mm for crm+
25... and crm+35... and 900 mm for all other typs. Adjust display to 250 mm or 900 mm. Confirm calibration with T1 + T2.
T1 + T2
T1
T2
T1 + T2
T2
T1
T1 + T2
T1
T2
T1 + T2
T2
T1
T1 + T2
T1
T2
T1 + T2
T2
T1
T1 + T2
T1
T2
T1 + T2
T2
T1
T1 + T2
T1
T2
T1 + T2
T2
T1
T1 + T2
T1
T2
T1 + T2
T2
T1
T1 + T2
T1
T2
T1 + T2
T2
T1
T1 + T2
T1
T2
T1 + T2
T2
T1
Delay in seconds between the detec­tion of an object and the output of the measured dis­tance in case of ob­ject approach (beha­ves as on-delay).
"00": 0 s (no delay) up to
"20": 20 s response time
Response time
T1 + T2
T1
T2
T1 + T2
T2
T1
Note
Changes in the Add-on menu may impair the sensor function. A6, A7, A8 , A10 , A11, A12 have influence on the response time of the sensor.
Hysteresis
switched output
Minimum value: »001«
Maximum value: dif­ference between maximum range and detect point - 1
During window mode operation hys­teresis influences both detect points.
T1 + T2
T1
T2
T1 + T2
T2
T1
Teach-in swítched output
Key lock and factory setting
Activate/deactivate
TouchControl
Reset to factory set-
ting
Turn supply voltage
OFF
While pressing T1 turn
supply voltage ON until »on« or »off« is
displayed
Turn supply voltage
OFF
While pressing T1 turn supply voltage ON for
ca. 15 s until «rESET» has past through the
display
To activate or
deactivate press T1
»on« or »off«
To activate or
deactivate press T1
»on« or »off«
Normal mode operation
Loading...