iID®DESKTOP smart USB 7.0
User Manual
DESKTOPSmartUSB7-0_UserManual_001E © 2019 microsensys User Manual
RFID Read/Write Device for transponders and sensors
The iID® DESKTOP smart USB 7.0 is a RFID device suitable for read/write of transponder and sensor units
working on HF (13.56MHz) frequency. It was designed for office and laboratory applications and is
particularly suitable for programming and evaluating TELID® sensor data loggers. The device is to be
powered using USB and works together with Windows. Exchanging of command and data with a PC will be
also done through the USB connector. Most of all established HF transponders and cards can be read and
written.
Product Short Description & available Versions:
iID® DESKTOP smart USB 7.0
Stationary HF RFID USB Read/Write module
CE, FCC, IC certified
System: iID®3000PRO, ISO 15693, ISO14443, all customized
Product Code: 35.29.701.00

iID®DESKTOP smart USB 7.0
User Manual
DESKTOPSmartUSB7-0_UserManual_001E © 2019 microsensys User Manual
FCC compliance statement
IC compliance statement
These devices comply with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. These devices may not cause harmful interferences;
2. These devices must accept any interference received, including interference that may cause undesired
operation.
The following figures list the Grant by FCC ID Number for each of the following devices:
FCC ID: ZLCDESKTOPSHFX
Please refer to the FCC’s website ( http://www.fcc.gov/ ) to view the grant and related documentation.
CAUTION !
Exposure to Radio Frequency Radiation. The radiated output of this device is far below the FCC radio
frequency exposure limits. Nevertheless, the device shall be used in such a manner that the potential for
human contact during normal operation is minimized. In order to avoid the possibility of exceeding the FCC
radio frequency exposure limits, human proximity to the antenna shall not be less than 20cm (8inches)
during normal operation. These devices may not be co-located with any other transmitter or transmitter
antenna.
NOTE:
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interferences when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment
in a residential area is likely to cause harmful interference in which case the user will be required to correct
the interference at his own expense.
Changes or modifications not expressly approved by Microsensys GmbH could void the user’s authority to
operate the equipment described in the manual.
Industry Canada ID: 21228-DESKTOPSHFX
This device complies with Industry Canada RSS-210. Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of
the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio RSS-210.
L’exploitation est autorisée aux deux conditions suivantes:
(1) l’appareil ne doit pas produire de brouillage, et
(2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.

iID®DESKTOP smart USB 7.0
User Manual
DESKTOPSmartUSB7-0_UserManual_001E © 2019 microsensys User Manual
Performance description
The iID® DESKTOP smart USB 7.0 is suitable for data capture and wireless RFID read / write applications,
which can be connected via its integrated USB interface to PCs.
Based on iID® SPC functionality, scripts can be used for definition of LED, as well as communication
functionalities as RF, USB.
The iID® DESKTOP smart USB 7.0 is a USB powered device.
The device supports HF systems suitable for closed coupling communication with very small sized up to
large RFID transponders. Additionally, all devices support TELID® sensor transponder applications.
First commissioning
Manner of functioning
The iID® DESKTOP smart USB 7.0 may be used as RFID read/write device with USB. See following table
for available configurations.
Operation mode
configuration
Bi-directional USB communication,
based on iID® driver engine, device
configuration
script with output functionality on
device
The iID® DESKTOP smart USB 7.0 is delivered in SPC/DOC mode. Please adjust operation mode
connecting to a PC via USB interface. Using iID® interface configuration tool you may configure the device
according your requirements before first usage. Micro-Sensys provides sample scripts for device usage in
SPC mode, which are available for download in iID® interface configuration tool.
(2)(3) Green and red
operation state LED

iID®DESKTOP smart USB 7.0
User Manual
DESKTOPSmartUSB7-0_UserManual_001E © 2019 microsensys User Manual
Software to be installed
Please download and install iID® software package including iID® DEMOsoft 2013 or TELID®Soft 5, iID®
interface config tool and iID® connection tool as well as iID® driver engine from:
https://www.microsensys.de/downloads/CDContent/Install/Setup%20iID%c2%ae%20software%20package.
exe
Device configuration is possible using iID® interface configuration tool running on Windows PC environment
- via BT connection as well as USB interface. For using USB interface you may also need to install the USB
driver, which is available at
https://www.microsensys.de/downloads/CDContent/USBDriver/Microsensys%20USB%20devices%20driver
%20CDM%20v2.12.16%20WHQL%20Certified.zip
Depending on operation mode (see “manner of functioning”) and platform installation of further software
may be required:
Windows 32/64
(without RT)
iID® software package including iID® driver engine, optional iID® tray
application
(https://www.microsensys.de/downloads/CDContent/Install/iID%c2%ae%20tr
ay%20application.zip)
Windows Mobile,
Windows embedded
handheld
iID® driver engine, iID® DEMOsoft
(https://www.microsensys.de/downloads/CDContent/Install/RFIDDriver/Wind
ows/iID3000PRO/,
https://www.microsensys.de/downloads/CDContent/Install/iID%c2%ae%20D
EMOsoft/Windows/Mobile/RFID-Demo%20iID%20driver%20engine.CAB,
optional iID® trigger scan
(https://www.microsensys.de/downloads/CDContent/Install/iID%c2%ae%20tr
ay%20application/iID%c2%ae%20TriggerScan%20Mobile/iID%20TriggerSca
n.CAB)
TELID®Soft5
(https://www.microsensys.de/downloads/CDContent/Install/iID%c2%ae%20D
EMOsoft/Android/)
Further Micro-Sensys product related software is located here:
https://www.microsensys.de/downloads/CDContent/
Signs & their meaning
The iID® DESKTOP smart USB 7.0 LEDs are used to show operation state. Additionally, there are device
states shown as described below.
(2) GREEN
operation state LED
in DOC mode automatic RF state visualization
in SPC mode free programmable
(3) RED
operation state LED
in DOC mode automatic RF state visualization
in SPC mode free programmable

iID®DESKTOP smart USB 7.0
User Manual
DESKTOPSmartUSB7-0_UserManual_001E © 2019 microsensys User Manual
Safety instructions
• The device may only be used for the intended purpose designed by for the manufacturer.
• Unauthorized changes and the use of spare parts and additional devices which have not
been sold or recommended by the manufacturer may cause fire, electric shocks or
injuries. Such unauthorized measures shall exclude any liability by the manufacturer.
• The liability-prescriptions of the manufacturer in the issue valid at the time of purchase are
valid for the device. The manufacturer shall not be held legally responsible for
inaccuracies, errors, or omissions in the manual or automatically set parameters for a
device or for an incorrect application of a device.
• Repairs may only be executed by the manufacturer.
• Installation, operation, and maintenance procedures should only be carried out by
qualified personnel.
• Use of the device and its installation must be in accordance with national legal
requirements and local electrical codes.
• When working on devices the valid safety regulations must be observed.

iID®DESKTOP smart USB 7.0
User Manual
DESKTOPSmartUSB7-0_UserManual_001E © 2019 microsensys User Manual
Technical data
Following table contains general technical data.
micro USB female, 5V +/- 5%, ripple <50mV
0mm...50 mm (depending on transponder type and environmental
conditions)

iID®DESKTOP smart USB 7.0
User Manual
DESKTOPSmartUSB7-0_UserManual_001E © 2019 microsensys User Manual
Equipment delivered:
1 x iID® DESKTOP smart USB 7.0
Standard accessories:
1 x USB cable
Complementary microsensys Documents
Technical Datasheet: DESKTOPSmart700-HF xxx.pdf
Product or System Documentation: DOC-iID SPC 01D.pdf
Contact/Copyright
Micro-Sensys GmbH • In der Hochstedter Ecke 2 • 99098 Erfurt • Germany
phone: +49 (0) 361 59874-0 fax: +49 (0) 361 59874-17
e-mail: info@microsensys.de web: www.microsensys.de
Any reproduction of this short manual in whole or in part, the storage in electronic media and the translation
into foreign languages without the written permission of microsensys GmbH is forbidden.
© 2019 microsensys • all rights reserved