This is a Class-A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Introduction
Features
Specifications
Packing List
Safety Precaution
CHAPTER
1Chapter1
Chapter 1 Overview
1.1 Introduction
The 4 10/100TX + 2 or 1 100FX Industrial Switch is a cost-effective solution and meets
the high reliability requirements demanded by industrial applications.
1.1.1 High-Speed Transmissions
The 4 10/100TX + 2 or 1 100FX Industrial Switch provides you with Fiber port for your
fiber optic cable to make a long-distance connection. The 4 10/100TX + 2 or 1 100FX
Industrial Switch includes a switch controller that can automatically sense transmission
speeds (10/100 Mbps). The RJ-45 interface can also be auto-detected, so MDI or MDIX is automatically selected and a crossover cable is not required. All Ethernet ports
have memory buffers that support the store-and-forward mechanism. This assures that
data is properly transmitted.
1.1.2 Dual Power Input
To reduce the risk of power failure, the 4 10/100TX + 2 or 1 100FX Industrial Switch
provides +12 ~ 48 VDC dual power inputs. If there is power failure, 4 10/100TX + 2 or 1
100FX Industrial Switch will automatically switch to the secondary power input.
1.1.3 Flexible Mounting
4 10/100TX + 2 or 1 100FX Industrial Switch is extremely compact and can be
mounted on a DIN-rail or a panel, so it is suitable for any space-constrained
environment.
1.1.4 Advanced Protection
The power line of 4 10/100TX + 2 or 1 100FX Industrial Switch supports up to 3000
VDC EFT protection, which secure equipment against unregulated voltage and make
systems safer and more reliable. Meanwhile, 4000 VDC ESD protections for Ethernet
ports make 4 10/100TX + 2 or 1 100FX Industrial Switch more suitable for harsh
environments.
1.1.5 Wide Operating Temperature
The operating temperature of the 4 10/100TX + 2 or 1 100FX Industrial Switch is
between -40 ~ 75 ℃ (wide operating temperature model) or -10 ~ 60 ℃ (standard
model). With such a wide range, you can use the 4 10/100TX + 2 or 1 100FX Industrial
Switch in some of the harshest industrial environments that exist.
1.1.6 Easy Troubleshooting
LED indicators make troubleshooting quick and easy. Each 10/100 Base-TX port has 2
LEDs that display the link status, transmission speed and collision status. Also the
three power indicators P1, P2 and Fault help you diagnose immediately.
2
1.2 Features
Provides 4 x 10/100TX + 2 x 100FX or 4 x 10/100TX + 1 x 100FX Mbps Ethernet
ports with
Provides 2K (wide operating temp. model) or 1K (standard model) MAC address
table
TX ports support full/half duplex flow control
Supports MDI/MDI-X auto-crossover
Supports surge (EFT) protection 3000 VDC for power line
Supports 4000 VDC Ethernet ESD protection
Provides broadcast storm protection
Embedded with a switch controller, supports auto-negotiation
Supports store & forward transmission
Supports redundant +12 ~ 48 VDC power input
Provides flexible mounting: DIN-rail, Wall Mounting
Supports operating temperatures from -40 ~ 75 ℃ (wide operating temperature
model) or -10 ~ 60 ℃ (standard model)
3 Chapter1
Communications
Compatibility
IEEE 802.3, 802.3u, 802.3x
LAN
10/100Base-TX, 100FX
Transmission Distance
Multi-Mode Fiber 2KM
(50/125μm ~ 62.5/125μm)
Single-Mode Fiber 30KM (9/125μm)
UTP/STP up to 100 meters
Transmission Speed
Up to 100 Mbps
Interface
Connectors
4 x RJ-45
2 x SC type 100M fiber (2 x 100FX model)
1 x SC type 100M fiber (1 x 100FX model)
6-pin removable screw terminal (power)
LED Indicators
Unit: P1, P2, Fault
TX port: Link/Active, Duplex/Collision
Power
Power Consumption
6.41 W (2 x 100FX model)
4.44 W (1 x 100FX model)
Power Input
2 x Unregulated +12 ~ 48 VDC
Fault Output
1 Relay Output
Mechanism
Dimensions (WxHxD)
30 x 95 x 140
Enclosure
IP30, Metal shell with solid mounting kits
Mounting
DIN35 rail, Wall
Protection
ESD (Ethernet)
4000 VDC
Surge (EFT for power)
3000 VDC
Power Reverse
Yes
Environment
Operating Temperature
-40~75 ℃ (wide operating temperature model)
-10~60 ℃ (standard temperature model)
1.3 Specification
4
Operating Humidity
5%~95% (non-condensing)
Storage Temperature
-40~85 ℃
Certifications
EMC
EU: EN55011, EN61000-6-4
EN55022, Class A,
EN61000-3-2/3
EN55024
IEC61000-4-2/3/4/5/6/8/11/12
EN61000-6-2
Free Fall
IEC60068-2-32
Shock
IEC60068-2-27
Vibration
IEC60068-2-6
5 Chapter1
Attention
IF DC voltage is supplied by an external circuit, please use a protection device
on the power supply input.
1.4 Packing List
4 x 10/100TX + 2 x 100FX or 4 x 10/100TX + 1 x 100FX Industrial Switch
1 x User manual
2 x Wall Mounting Bracket and Screws
1.5 Safety Precaution
6
Installation
Sections include:
LED Indicators
Dimensions
Mounting
Network Connection
Power Connection
CHAPTER
7Chapter2
Table 2.1: 4 10/100TX + 2 or 1 100FX Industrial Switch LED Definition
LED
Color
Description
P1
Green
On
Power input 1 is active
Off
Power input 1 is inactive
P2
Green
On
Power input 2 is active
Off
Power input 2 is inactive
P-Fail
Red
On
Power input 1 or 2 is inactive
Off
Power input 1 and 2 are both active, or no power input
Link/Active
(1~6 for 2 x 100FX)
(1~5 for 1 x 100FX)
Green
On
Connected to network
Flashing
Networking is active
Off
Not connected to network
Duplex/Collision
(1~4)
Orange
On
Ethernet port full duplex
Flashing
Collision of packets occurs
Off
Ethernet port half duplex or not connect to network
Chapter 2 Installation
In this chapter, you will be given an overview of the 4 10/100TX + 2 or 1 100FX
Industrial Switch hardware installation procedures.
2.1 LED Indicators
There are few LEDs display the power status and network status located on the front
panel of 4 10/100TX + 2 or 1 100FX Industrial Switch, each of them has its own
specific meaning as below table.
8
2.2 Dimensions (units: mm)
Figure 2.1: Front View of 4 10/100TX + 2 or 1 100FX Industrial Switch
9 Chapter2
Figure 2.2: Side View of 4 10/100TX + 2 or 1 100FX Industrial Switch
10
Figure 2.3: Rear View of 4 10/100TX + 2 or 1 100FX Industrial Switch
11 Chapter2
Please refer to page 17 for pin assignment of power connector.
Figure 2.4: Top View of 4 10/100TX + 2 or 1 100FX Industrial Switch
12
2.3 Mounting
The 4 10/100TX + 2 or 1 100FX Industrial Switch supports two mounting methods:
DIN-rail & Wall.
2.3.1 Wall mounting
4 10/100TX + 2 or 1 100FX Industrial Switch can be wall-mounted by using the
included mounting kit. Then, hang on the 4 10/100TX + 2 or 1 100FX Industrial Switch
to the nails on the wall.
First, use the screws included in the package to combine the 4 10/100TX + 2 or 1
100FX Industrial Switch and metal mounting kit. And then you can install the device
firmly via the components, please see Figure 2.5 as below.
Figure 2.5: Combine the Metal Mounting Kit
13 Chapter2
2.3.2 DIN-rail Mounting
You can also mount 4 10/100TX + 2 or 1 100FX Industrial Switch on a standard DINrail by below steps.
The DIN-rail kit is screwed on the industrial switch when out of factory. If the DIN-rail kit
is not screwed on the industrial switch, please screw the DIN-rail kit on the switch first.
First, hang the 4 10/100TX + 2 or 1 100FX Industrial Switch to the DIN-rail with angle
of inclination. See figure 2.6.
Figure 2.6: Installation to DIN-rail Step 1
14
Then, let the device down straight to slide over the rail smoothly. See Figure 2.7
Figure 2.7: Installation to DIN-rail Step 2
15 Chapter2
Attention
This is a Class 1 Laser/LED product. Don’t stare into the Laser/LED Beam.
2.4 Network Connection
The 4 10/100TX + 2 or 1 100FX Industrial Switch has the SC type fiber port using in
multi mode (2Km) or single mode (30Km). When you connect the fiber port to another
one, please follow the below figure to connect it. Wrong connection will not allow the
port to work normally.
Figure 2.8: Pin Assignment of the Power Connector
The 4 10/100TX + 2 and 1 100FX Industrial Switch both have 4 x RJ-45 ports that
support connection to 10 Mbps Ethernet, or 100 Mbps Fast Ethernet, and half or full
duplex operation. 4 10/100TX + 2 or 1 100FX Industrial Switch can be connected to
other hubs or switches through a twisted-pair straight through the cable or a crossover
cable up to 100m long. The connection can be made from any TX port of the 4
10/100TX + 2 or 1 100FX Industrial Switch (MDI-X) to another hub or switch either
MDI-X or uplink MDI port.
The 4 10/100TX + 2 or 1 100FX Industrial Switch supports auto-crossover to make
networking more easy and flexible. You can connect any RJ-45 (MDI-X) station port on
the switch to any device such as a switch, bridge or router.
16
2.5 Power Connection
The 4 10/100TX + 2 or 1 100FX Industrial Switch supports dual +12 ~ 48 VDC power
inputs and power-fail relay output.
Figure 2.9: Pin Assignment of the Power Connector
You can connect an alarm indicator, buzzer or other signaling equipment through the
relay output. The relay opens if power input 1 or 2 fails ( “Open” means if you connect
relay output with an LED, the light would be off).
17 Chapter2
18
Troubleshooting
CHAPTER
19Chapter2
Chapter 3 Troubleshooting
1. Power Input
Verify that is using the right power cord/adapter (+12~48 VDC), please don’t use the
power adaptor with DC output voltage higher than 48V, or it will burn this converter
down.
2. Cable
Select the proper UTP cable to construct user network. Please check that is using the
right cable. Use Unshielded Twisted-Pair (UTP) or Shielded Twisted-Pair (STP) cable
for RJ-45 connections: 100 Category 3, 4 or 5 cable for 10 Mbps connections or 100
Category 5 cable for 100 Mbps connections. Also, be sure that the length of any
twisted-pair connection does not exceed 100 meters (328 feet).
Otherwise, use the 50/125 ~ 62.5µm fiber cable to connect the fiber port in multi-mode
or 9/125µm fiber cable in single-mode.
3. Diagnosing LED Indicators
The switch can be easily monitored through panel indicators, which describes common
problems user may encounter and where user can find possible solutions, to assist in
identifying.
If the power indicator does not light up when the power cord is plugged in, user may
have a problem with power cord. Then check for loose power connections, power
losses or surges at power outlet. If user still cannot resolve the problem, contact the
local dealer for assistance.
If the Industrial switch LED indicators are normal and the connected cables are correct
but the packets still cannot transmit, please check your system’s Ethernet devices
configuration or status.
20
Pin Assignment & Wiring
APPENDIX
21Chapter2
Appendix A Pin Assignment & Wiring
It is suggested to adopt ELA/TIA as the wiring of the RJ-45.
Figure A.1: RJ-45 Pin Assignment
Figure A.2: EIA/TIA-568B
Figure A.2: EIA/TIA-568A