Layer 2 Switch
with 8 10/100BASE-TX (RJ-45) Ports,
and 2 Gigabit Combination Ports (RJ-45/SFP)
MS453490M
E102010-CS-R01
149100000110A
COMPLIANCESAND SAFETY
STATEMENTS
CE MARK DECLARATIONOF CONFORMANCEFOR EMI AND SAFETY (EEC)
This information technology equipment complies with the requirements of the
Council Directive 89/336/EEC on the Approximation of the laws of the Member
States relating to Electromagnetic Compatibility and 73/23/EEC for electrical
equipment used within certain voltage limits and the Amendment Directive 93/
68/EEC. For the evaluation of the compliance with these Directives, the following
standards were applied:
RFI Emission:
Immunity:
LVD:
◆Limit class A according to EN 55022
◆Limit class A for harmonic current emission according to EN 61000-3-
2
◆Limitation of voltage fluctuation and flicker in low-voltage supply
system according to EN 61000-3-3
◆Product family standard according to EN 55024
◆Electrostatic Discharge according to EN 61000-4-2
◆Radio-frequency electromagnetic field according to EN 61000-4-3
◆Electrical fast transient/burst according to EN 61000-4-4
◆Surge immunity test according to EN 61000-4-5
◆Immunity to conducted disturbances, Induced by radio-frequency
fields: EN 61000-4-6
◆Power frequency magnetic field immunity test according to EN 61000-
4-8
◆Voltage dips, short interruptions and voltage variations immunity test
according to EN 61000-4-11
◆EN60950-1:2006+A11:2009
– 5 –
C
CLASS I
LASER DEVICE
DISPOSITIF LASER
DE CLASSE I
LASERGER
DER KLASSE I
ÄT
OMPLIANCES AND SAFETY STATEMENTS
SAFETY COMPLIANCE
W
ARNING
:
fiber optic, although invisible to the human eye, can nevertheless
cause damage.
To avoid damage to the eyes:
◆never look straight into the output of fiber optic components -
◆cover all unused optical connections with caps.
◆commission the transmission link only after completing all
The active laser components used with this product comply with the
provisions of Laser Class 1.
A
TTENTION
transmission de données via la Fibre Optique, ne sont pas visibles à
l'œil nu mais peuvent tout de même être dangereux pour l'œil humain.
Pour éviter toute nuisance à l'œil:
◆Ne jamais approcher ses yeux trop près de la sortie des
◆Couvrir les connecteurs optiques non utilisés d'un cache.
◆Mettre en service la ligne de transmission une fois que tous les
Les composants Laser optiques utilisés dans ce produit appartiennent
à la Classe-Laser 1.
A
CHTUNG
Glasfaserbereich verwendet wird, ist für das menschliche Auge nicht
sichtbar, kann aber dennoch zu Schädigungen führen.
Bitte beachten Sie immer folgende Hinweise, um Augenschäden zu
vermeiden:
◆schauen Sie niemals mit ungeschütztem Auge in die sich im
◆versehen Sie unbenutzte aktive Glasfaseranschlüsse immer mit
◆Übertragungsstrecke erst in Betrieb nehmen, wenn alle
In diesem Produkt verwendete aktive Laser-Komponenten
entsprechen der Laserschutzklasse 1.
Infrared radiation as used for data transmission within the
danger of blinding!
connections.
:
les rayons Infrarouge, utilisés usuellement pour la
composants optiques ou de la Fibre Optique. Danger
d'aveuglement!
branchements ont été effectués.
:
Infrarot-Strahlung, wie sie für die Datenübertragung im
Betrieb befindenden optischen Ausgänge!
den mitgelieferten Schutzkappen!
Verbindungen hergestellt sind
– 6 –
C
OMPLIANCES AND SAFETY STATEMENTS
POWER CORD SAFETY
Please read the following safety information carefully before installing
the switch:
WARNING:
Installation and removal of the unit must be carried out by qualified
personnel only.
◆The unit must be connected to an earthed (grounded) outlet to comply with
international safety standards.
◆Do not connect the unit to an A.C. outlet (power supply) without an earth
(ground) connection.
◆The appliance coupler (the connector to the unit and not the wall plug) must
have a configuration for mating with an EN 60320/IEC 320 appliance inlet.
◆The socket outlet must be near to the unit and easily accessible. You can
only remove power from the unit by disconnecting the power cord from the
outlet.
◆This unit operates under SELV (Safety Extra Low Voltage) conditions
according to IEC 60950. The conditions are only maintained if the
equipment to which it is connected also operates under SELV conditions.
France and Peru only
This unit cannot be powered from IT
†
supplies. If your supplies are of IT type,
this unit must be powered by 230 V (2P+T) via an isolation transformer ratio
1:1, with the secondary connection point labelled Neutral, connected directly to
earth (ground).
†
Impédance à la terre
I
MPORTANT
!
Before making connections, make sure you have the correct cord
set. Check it (read the label on the cable) against the following:
– 7 –
C
OMPLIANCES AND SAFETY STATEMENTS
Power Cord Set
U.S.A. and CanadaThe cord set must be UL-approved and CSA certified.
The minimum specifications for the flexible cord are:
- No. 18 AWG - not longer than 2 meters, or 16 AWG.
- Type SV or SJ
- 3-conductor
The cord set must have a rated current capacity of at least 10 A
The attachment plug must be an earth-grounding type with NEMA
5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V) configuration.
DenmarkThe supply plug must comply with Section 107-2-D1, Standard
SwitzerlandThe supply plug must comply with SEV/ASE 1011.
U.K.The supply plug must comply with BS1363 (3-pin 13 A) and be fitted
EuropeThe supply plug must comply with CEE7/7 (“SCHUKO”).
DK2-1a or DK2-5a.
with a 5 A fuse which complies with BS1362.
The mains cord must be <HAR> or <BASEC> marked and be of type
HO3VVF3GO.75 (minimum).
The mains cord must be <HAR> or <BASEC> marked and be of type
HO3VVF3GO.75 (minimum).
IEC-320 receptacle.
Veuillez lire à fond l'information de la sécurité suivante avant d'installer
le Switch:
AVERTISSEMENT:
L’installation et la dépose de ce groupe doivent être confiés à
un personnel qualifié.
◆Ne branchez pas votre appareil sur une prise secteur (alimentation
électrique) lorsqu'il n'y a pas de connexion de mise à la terre (mise à la
masse).
◆Vous devez raccorder ce groupe à une sortie mise à la terre (mise à la
masse) afin de respecter les normes internationales de sécurité.
◆Le coupleur d’appareil (le connecteur du groupe et non pas la prise murale)
doit respecter une configuration qui permet un branchement sur une entrée
d’appareil EN 60320/IEC 320.
– 8 –
C
OMPLIANCES AND SAFETY STATEMENTS
◆La prise secteur doit se trouver à proximité de l’appareil et son accès doit
être facile. Vous ne pouvez mettre l’appareil hors circuit qu’en débranchant
son cordon électrique au niveau de cette prise.
◆L’appareil fonctionne à une tension extrêmement basse de sécurité qui est
conforme à la norme IEC 60950. Ces conditions ne sont maintenues que si
l’équipement auquel il est raccordé fonctionne dans les mêmes conditions.
France et Pérou uniquement:
Ce groupe ne peut pas être alimenté par un dispositif à impédance à la terre. Si
vos alimentations sont du type impédance à la terre, ce groupe doit être
alimenté par une tension de 230 V (2 P+T) par le biais d’un transformateur
d’isolement à rapport 1:1, avec un point secondaire de connexion portant
l’appellation Neutre et avec raccordement direct à la terre (masse).
Cordon électrique - Il doit être agréé dans le pays d’utilisation
Etats-Unis et Canada:Le cordon doit avoir reçu l’homologation des UL et un certificat de
Danemark:La prise mâle d’alimentation doit respecter la section 107-2 D1 de
Suisse:La prise mâle d’alimentation doit respecter la norme SEV/ASE
EuropeLa prise secteur doit être conforme aux normes CEE 7/7
la CSA.
Les spécifications minimales pour un cable flexible sont AWG No.
18, ouAWG No. 16 pour un cable de longueur inférieure
ètres.
m
- type SV ou SJ
- 3 conducteurs
Le cordon doit être en mesure d’acheminer un courant nominal
d’au moins 10 A.
La prise femelle de branchement doit être du type à mise à la
terre (mise à la masse) et respecter la configuration NEMA 5-15P
(15 A, 125 V) ou NEMA 6-15P (15 A, 250 V).
la norme DK2 1a ou DK2 5a.
1011.
(“SCHUKO”)
LE cordon secteur doit porter la mention <HAR> ou <BASEC> et
doit être de type HO3VVF3GO.75 (minimum).
à 2
– 9 –
C
OMPLIANCES AND SAFETY STATEMENTS
Bitte unbedingt vor dem Einbauen des Switches die folgenden
Sicherheitsanweisungen durchlesen:
WARNUNG:
Die Installation und der Ausbau des Geräts darf nur durch
Fachpersonal erfolgen.
◆Das Gerät sollte nicht an eine ungeerdete Wechselstromsteckdose
angeschlossen werden.
◆Das Gerät muß an eine geerdete Steckdose angeschlossen werden, welche
die internationalen Sicherheitsnormen erfüllt.
◆Der Gerätestecker (der Anschluß an das Gerät, nicht der
Wandsteckdosenstecker) muß einen gemäß EN 60320/IEC 320
konfigurierten Geräteeingang haben.
◆Die Netzsteckdose muß in der Nähe des Geräts und leicht zugänglich sein.
Die Stromversorgung des Geräts kann nur durch Herausziehen des
Gerätenetzkabels aus der Netzsteckdose unterbrochen werden.
◆Der Betrieb dieses Geräts erfolgt unter den SELV-Bedingungen
(Sicherheitskleinstspannung) gemäß IEC 60950. Diese Bedingungen sind
nur gegeben, wenn auch die an das Gerät angeschlossenen Geräte unter
SELV-Bedingungen betrieben werden.
Stromkabel. Dies muss von dem Land, in dem es benutzt wird geprüft werden:
SchweizDieser Stromstecker muß die SEV/ASE 1011Bestimmungen einhalten.
EuropeDas Netzkabel muß vom Typ HO3VVF3GO.75 (Mindestanforderung)
sein und die Aufschrift <HAR> oder <BASEC> tragen.
Der Netzstecker muß die Norm CEE 7/7 erfüllen (”SCHUKO”).
– 10 –
WARNINGSAND CAUTIONARY MESSAGES
W
ARNING
:
This product does not contain any serviceable user parts.
W
ARNING
:
qualified personnel only.
W
field ground lead on the tri-pole power plug to a valid earth ground line
to prevent electrical hazards.
W
cable. The lasers are compliant with the requirements of a Class 1
Laser Product and are inherently eye safe in normal operation.
However, you should never look directly at a transmit port when it is
powered on.
C
AUTION
measures to prevent electrostatic discharge when handling this
equipment.
C
AUTION
may damage this device.
C
AUTION
conform to FCC standards.
Installation and removal of the unit must be carried out by
ARNING
:
When connecting this device to a power outlet, connect the
ARNING
:
This switch uses lasers to transmit signals over fiber optic
:
Wear an anti-static wrist strap or take other suitable
:
Do not plug a phone jack connector in the RJ-45 port. This
:
Use only twisted-pair cables with RJ-45 connectors that
C
OMPLIANCES AND SAFETY STATEMENTS
ENVIRON ME NTAL STATEMENTS
The manufacturer of this product endeavours to sustain an environmentallyfriendly policy throughout the entire production process. This is achieved though
the following means:
◆Adherence to national legislation and regulations on environmental
production standards.
◆Conservation of operational resources.
◆Waste reduction and safe disposal of all harmful un-recyclable by-products.
◆Recycling of all reusable waste content.
◆Design of products to maximize recyclables at the end of the product’s life
span.
◆Continual monitoring of safety standards.
– 11 –
C
OMPLIANCES AND SAFETY STATEMENTS
ENDOF PRODUCT LIFE SPAN
This product is manufactured in such a way as to allow for the recovery and
disposal of all included electrical components once the product has reached the
end of its life.
MANUFACTURING MATERIALS
There are no hazardous nor ozone-depleting materials in this product.
DOCUMENTATION
All printed documentation for this product uses biodegradable paper that
originates from sustained and managed forests. The inks used in the printing
process are non-toxic.
– 12 –
ABOUT THIS GUIDE
PURPOSE
This guide details the hardware features of the switch, including the physical and
performance-related characteristics, and how to install the switch.
AUDIENCE
The guide is intended for use by network administrators who are responsible for
installing and setting up network equipment; consequently, it assumes a basic
working knowledge of LANs (Local Area Networks).
CONVENTIONS
The following conventions are used throughout this guide to show information:
N
OTE
:
Emphasizes important information or calls your attention to
related features or instructions.
C
AUTION
:
or damage the system or equipment.
Alerts you to a potential hazard that could cause loss of data,
W
ARNING
:
Alerts you to a potential hazard that could cause personal
injury.
RELATED PUBLICATIONS
The following publication gives specific information on how to operate and use
the management functions of the switch:
The Management Guide
– 13 –
A
BOUT THIS GUIDE
REVISION HISTORY
This section summarizes the changes in each revision of this guide.
OCTOBER 2010 REVISION
This is the first revision of this guide.
– 14 –
CONTENTS
COMPLIANCESAND SAFETY STATEMENTS 5
A
BOUT THIS GUIDE 13
C
ONTENTS 15
T
ABLES 17
F
IGURES 19
1I
NTRODUCTION 21
Overview 21
Description of Hardware 23
2NETWORK PLANNING 27
Introduction to Switching 27
Application Examples 28
Application Notes 32
3INSTALLINGTHE SWITCH 33
Selecting a Site 33
Ethernet Cabling 34
Equipment Checklist 35
Mounting 35
Installing an Optional SFP Transceiver 37
Connecting to a Power Source 38
Connecting to the Console Port 39
The MS453490M is a Fast Ethernet Layer 2 switch with 8 100BASE-TX ports, and
two Gigabit combination ports: 1000BASE-T RJ-45 and Small Form Factor
Pluggable (SFP) transceiver slots
includes an SNMP-based management agent, which provides both in-band and
out-of-band access for managing the switch.
The MS453490M provides a broad range of powerful features for Layer 2
switching, delivering reliability and consistent performance for your network
traffic. It brings order to poorly performing networks by segregating them into
separate broadcast domains with IEEE 802.1Q compliant VLANs, and empowers
multimedia applications with multicast switching and CoS services.
Figure 1: Front Panel
1
(see Figure 1-1, Ports 9-10). The switch also
1.If an SFP transceiver is plugged in, the corresponding RJ-45 port is disabled for
ports 9-10.
– 21 –
C
Power Socket
HAPTER
1
Overview
Figure 2: Rear Panel
| Introduction
SWITCH ARCHITECTURE
The switch employs a wire-speed, non-blocking switching fabric. This permits
simultaneous wire-speed transport of multiple packets at low latency on all
ports. The switch also features full-duplex capability on all ports, which
effectively doubles the bandwidth of each connection.
This switch uses store-and-forward switching to ensure maximum data integrity.
With store-and-forward switching, the entire packet must be received into a
buffer and checked for validity before being forwarded. This prevents errors
from being propagated throughout the network.
NETWORK MANAGEMENT OPTIONS
With a comprehensive array of LEDs, the switch provides “at a glance”
monitoring of network and port status. The switch can be managed over the
network with a web browser or Telnet application, or via a direct connection to
the console port. The switch includes a built-in network management agent that
allows it to be managed in-band using SNMP or RMON (Groups 1, 2, 3, 9)
protocols. It also has an RS-232 serial port (DB-9 connector) on the front panel
for out-of-band management. A PC may be connected to this port
configuration and monitoring out-of-band via a
null-modem serial cable.
For a detailed description of the management features, refer to the Management Guide.
– 22 –
for
C
HAPTER
1
| Introduction
Description of Hardware
DESCRIPTIONOF HARDWARE
RJ-45 PORTS
The switch contains 8 100BASE-TX RJ-45 ports and 2 shared
1000BASE-T RJ-45/SFP ports. All RJ-45 ports support automatic MDI/MDI-X
operation, so you can use straight-through cables for all network connections to
PCs or servers, or to other switches or hubs. (See “1000BASE-T Pin
Assignments” on page 54.)
Each of these ports support auto-negotiation, so the optimum transmission
mode (half or full duplex), and data rate (10, or 100 Mbps - ports 1~8, and 10,
100, or 1000 - ports 9~10) can be selected automatically
Each port also supports IEEE 802.3x auto-negotiation of flow control, so the
switch can automatically prevent port buffers from becoming saturated.
SFP TRANSCEIVER SLOTS
The Small Form Factor Pluggable (SFP) transceiver slots are shared with the two
1000BASE-T RJ-45 ports (ports 9~10). In the default configuration, if an SFP
transceiver (purchased separately) is installed in a slot and has a valid link on
the port, the associated RJ-45 port is disabled. The switch can also be
configured to force the use of an RJ-45 port or SFP slot, as required.
2
.
The following table shows a list of transceiver types which have been tested with
the switch. For an updated list of vendors supplying these transceivers, contact
your local dealer. For information on the recommended standards for fiber optic
cabling, see “1000 Mbps Gigabit Ethernet Collision Domain” on page 45.
Table 1: Supported SFP Transceivers
Media Standard Cable Diameter
1000BASE-SX50/125850550 m
2.The 1000BASE-T standard does not support forced mode. Auto-negotiation must
always be used to establish a connection over any 1000BASE-T port or trunk.
(microns)
62.5/125850400 m
Wavelength (nm)
– 23 –
Maximum Distance
*
C
Power
Diag
1
35
79
246810
Power
Diag
1
35
79
246810
Port Status LEDs
System Status LEDs
HAPTER
1
Description of Hardware
| Introduction
Table 1: Supported SFP Transceivers (Continued)
Media Standard Cable Diameter
(microns)
Wavelength (nm)
Maximum Distance
*
1000BASE-LX50/1251300550 m
62.5/1251300550 m
9/125130010 km
1000BASE-LH9/125131035 km
155080 km
1000BASE-T100 m
*Maximum distance may vary for different SFP vendors.
PORTAND SYSTEM STATUS LEDS
The switch includes a display panel for key system and port indications that
simplify installation and network troubleshooting. The LEDs, which are located
on the front panel for easy viewing, are shown below and described in the
following tables.
Figure 3: Port LEDs
– 24 –
C
HAPTER
1
| Introduction
Description of Hardware
Table 2: 10/100 Mbps Port Status LEDs (1~8)
LEDConditionStatus
(Link/Activity)On/Flashing GreenPort has established a valid 10/100 Mbps network
OffThere is no valid link on the port.
Table 3: 1000 Mbps Port Status LEDs (9~10)
LEDConditionStatus
(Link/Activity)On/Flashing GreenPort has established a valid 1000 Mbps network
On/Flashing AmberPort has established a valid 10/100 Mbps network
OffThere is no valid link on the port.
Table 4: System Status LEDs
LEDConditionStatus
PowerOn GreenThe unit’s internal power supply is operating
On AmberThe unit has an internal power supply fault.
OffThe unit has no power connected.
DiagOn GreenThe system diagnostic test has completed
Flashing GreenThe system diagnostic test is in progress.
On AmberThe system diagnostic test has detected a fault.
connection. Flashing indicates activity.
connection. Flashing indicates activity.
connection. Flashing indicates activity.
normally.
successfully.
– 25 –
C
HAPTER
1
Description of Hardware
| Introduction
POWER SUPPLY SOCKET
There is one power socket on the rear panel of the switch. The standard power
socket is for the AC power cord.
Figure 4: Power Supply Socket
– 26 –
2NETWORK PLANNING
INTRODUCTIONTO SWITCHING
A network switch allows simultaneous transmission of multiple packets via noncrossbar switching. This means that it can partition a network more efficiently
than bridges or routers. The switch has, therefore, been recognized as one of
the most important building blocks for today’s networking technology.
When performance bottlenecks are caused by congestion at the network access
point (such as the network card for a high-volume file server), the device
experiencing congestion (server, power user, or hub) can be attached directly to
a switched port. And, by using full-duplex mode, the bandwidth of the dedicated
segment can be doubled to maximize throughput.
When networks are based on repeater (hub) technology, the distance between
end stations is limited by a maximum hop count. However, a switch turns the
hop count back to zero. So subdividing the network into smaller and more
manageable segments, and linking them to the larger network by means of a
switch, removes this limitation.
A switch can be easily configured in any Ethernet, Fast Ethernet, or Gigabit
Ethernet network to significantly boost bandwidth while using conventional
cabling and network cards.
– 27 –
C
Power
Diag
1
35
79
2468 10
Power
Diag
1
35
79
2468 10
HAPTER
2
Application Examples
| Network Planning
APPLICATION EXAMPLES
The switch is not only designed to segment your network, but also to provide a
wide range of options in setting up network connections. Some typical
applications are described below.
COLLAPSED BACKBONE
The switch is an excellent choice for mixed Ethernet, Fast Ethernet, and Gigabit
Ethernet installations where significant growth is expected in the near future.
You can easily build on this basic configuration, adding direct full-duplex
connections to workstations or servers. When the time comes for further
expansion, just connect to another hub or switch using one of the Fast Ethernet
ports built into the front panel or a Gigabit Ethernet port on a plug-in SFP
transceiver.
In the figure below, the switch is operating as a collapsed backbone for a small
LAN. It is providing dedicated 10 Mbps full-duplex connections to workstations,
100 Mbps full-duplex connections to power users, and 1 Gbps full-duplex
connections to servers.
Figure 5: Collapsed Backbone
– 28 –
C
Server Farm
10/100 Mbps
Segments
...
...
1000 Mbps
Segments
Power
Diag
1
35
79
2468 10
Power
Diag
1
35
79
2468 10
HAPTER
2
| Network Planning
Application Examples
NETWORK AGGREGATION PLAN
With 10 parallel bridging ports (i.e., 10 distinct collision domains), the switch can
collapse a complex network down into a single efficient bridged node, increasing
overall bandwidth and throughput.
In the figure below, the 100BASE-TX ports on the switch are providing 100 Mbps
connectivity for up to 8 segments. In addition, the switch is also connecting
several servers at 1000 Mbps.
Figure 6: Network Aggregation Plan
– 29 –
C
...
...
Headquarters
1000BASE-LX SMF
(10 kilometers)
Remote Switch
10/100/1000 Mbps Segments
1000BASE-SX MMF
(550 meters)
Remote Switch
Server Farm
28
27
28
27
Power
Diag
1
35
79
2468 10
Power
Diag
1
35
79
2468 10
HAPTER
2
Application Examples
| Network Planning
REMOTE CONNECTIONSWITH FIBER CABLE
Fiber optic technology allows for longer cabling than any other media type. A
1000BASE-SX (MMF) link can connect to a site up to 550 meters away, a
1000BASE-LX (SMF) link up to 10 km, and a 1000BASE-LH link up to 80 km.
This allows the switch to serve as a collapsed backbone, providing direct
connectivity for a widespread LAN.
The figure below illustrates the switch connecting multiple segments with fiber
cable.
Figure 7: Remote Connections with Fiber Cable
– 30 –
C
Finance
Marketing
VLAN 3
Untagged Ports
VLAN
unaware
switch
Tagged Port
VLAN
aware
switch
Tagged
Ports
Finance
VLAN 3
R&D
VLAN 2
Testing
R&D
Testing
VLAN 1
VLAN 2
VLAN 4
VLAN 1
Power
Diag
1
35
79
2468 10
Power
Diag
1
35
79
2468 10
HAPTER
2
| Network Planning
Application Examples
MAKING VLAN CONNECTIONS
This switch supports VLANs which can be used to organize any group of network
nodes into separate broadcast domains. VLANs confine broadcast traffic to the
originating group, and can eliminate broadcast storms in large networks. This
provides a more secure and cleaner network environment.
VLANs can be based on untagged port groups, or traffic can be explicitly tagged
to identify the VLAN group to which it belongs. Untagged VLANs can be used for
small networks attached to a single switch. However, tagged VLANs should be
used for larger networks, and all the VLANs assigned to the inter-switch links.
Figure 8: Making VLAN Connections
N
OTE
:
When connecting to a switch that does not support IEEE 802.1Q
VLAN tags, use untagged ports.
– 31 –
C
HAPTER
2
Application Notes
| Network Planning
APPLICATION NOTES
1. Full-duplex operation only applies to point-to-point access (such as when a
switch is attached to a workstation, server or another switch). When the
switch is connected to a hub, both devices must operate in half-duplex
mode.
2. Avoid using flow control on a port connected to a hub unless it is actually
required to solve a problem. Otherwise back pressure jamming signals may
degrade overall performance for the segment attached to the hub.
3. Based on recommended standards, the length of fiber optic cable for a
single switched link should not exceed:
■
1000BASE-SX: 550 m (1805 ft) for multimode fiber.
■
1000BASE-LX: 10 km (6.2 miles) for single-mode fiber.
■
1000BASE-LH: 80 km (49.7 miles) for single-mode fiber.
However, power budget constraints must also be considered when
calculating the maximum cable length for your specific environment.
– 32 –
3INSTALLINGTHE SWITCH
SELECTINGA SITE
Switch units can be mounted in a standard 19-inch equipment rack or on a flat
surface. Be sure to follow the guidelines below when choosing a location.
◆The site should:
■
be at the center of all the devices you want to link and near a power
outlet.
■
be able to maintain its temperature within 0 to 45 °C (32 to 113 °F)
and its humidity within 10% to 90%, non-condensing
■
provide adequate space (approximately two inches) on all sides for
proper air flow
■
be accessible for installing, cabling and maintaining the devices
■
allow the status LEDs to be clearly visible
◆Make sure twisted-pair cable is always routed away from power lines,
fluorescent lighting fixtures and other sources of electrical interference,
such as radios and transmitters.
◆Make sure that the unit is connected to a separate grounded power outlet
that provides 100 to 240 VAC, 50 to 60 Hz, is within 2 m (6.6 feet) of each
device and is powered from an independent circuit breaker. As with any
equipment, using a filter or surge suppressor is recommended.
– 33 –
C
RJ-45 Connector
HAPTER
3
Ethernet Cabling
| Installing the Switch
ETHERNET CABLING
To ensure proper operation when installing the switch into a network, make sure
that the current cables are suitable for 10BASE-T, 100BASE-TX or 1000BASE-T
operation. Check the following criteria against the current installation of your
network:
cables with RJ-45 connectors; Category 3 or better for 10BASE-T, Category
5 or better for 100BASE-TX, and Category 5, 5e or 6 for 1000BASE-T.
◆Protection from radio frequency interference emissions
◆Electrical surge suppression
◆Separation of electrical wires (switch related or other) and electromagnetic
fields from data based network wiring
◆Safe connections with no damaged cables, connectors or shields
Figure 9: RJ-45 Connections
– 34 –
C
HAPTER
3
| Installing the Switch
Equipment Checklist
EQUIPMENT CHECKLIST
After unpacking this switch, check the contents to be sure you have received all
the components. Then, before beginning the installation, be sure you have all
other necessary installation equipment.
PACKAGE CONTENTS
◆Fast Ethernet Switch (MS453490M)
◆Four adhesive foot pads
◆Power Cord—either US, Continental Europe or UK
◆RJ-45 to RS-232 console cable
◆Management Guide CD
MOUNTING
The switch can be mounted on a desktop or shelf. Mounting instructions follow.
DESKTOPOR SHELF MOUNTING
1. Attach the four adhesive feet to the bottom of the first switch.
– 35 –
C
P
o
w
e
r
D
ia
g
1
35
79
2468 1
0
P
o
w
e
r
D
ia
g
1
35
79
2468 1
0
HAPTER
3
Mounting
| Installing the Switch
Figure 10: Attaching the Adhesive Feet
2. Set the device on a flat surface near an AC power source, making sure there
are at least two inches of space on all sides for proper air flow.
3. If installing a single switch only, go to “Connecting to a Power Source” on
page 38.
4. If installing multiple switches, attach four adhesive feet to each one. Place
each device squarely on top of the one below, in any order.
– 36 –
C
P
o
w
e
r
D
ia
g
1
35
79
2468 1
0
P
o
w
e
r
D
ia
g
1
35
79
2468 1
0
HAPTER
3
Installing an Optional SFP Transceiver
| Installing the Switch
INSTALLINGAN OPTIONAL SFP TRANSCEIVER
Figure 11: Inserting an SFP Transceiver into a Slot
The SFP slots support the following optional SFP transceivers:
◆1000BASE-SX
◆1000BASE-LX
◆1000BASE-LH
To install an SFP transceiver, do the following:
1. Consider network and cabling requirements to select an appropriate SFP
transceiver type.
2. Insert the transceiver with the optical connector facing outward and the slot
connector facing down. Note that SFP transceivers are keyed so they can
only be installed in one orientation.
3. Slide the SFP transceiver into the slot until it clicks into place.
– 37 –
C
HAPTER
3
Connecting to a Power Source
| Installing the Switch
N
OTE
:
SFP transceivers are hot-swappable. The switch does not need to
be powered off before installing or removing a transceiver. However,
always first disconnect the network cable before removing a
transceiver.
N
OTE
:
SFP transceivers are not provided in the switch package.
CONNECTINGTOA POWER SOURCE
To connect a switch to a power source:
1. Insert the power cable plug directly into the AC socket located at the back of
the switch.
Figure 12: Power Socket
2. Plug the other end of the cable into a grounded, 3-pin, AC power source.
N
OTE
:
For International use, you may need to change the AC line cord.
You must use a line cord set that has been approved for the socket type
in your country.
3. Check the front-panel LEDs as the device is powered on to be sure the
Power LED is lit. If not, check that the power cable is correctly plugged in.
– 38 –
C
RJ-45 Connector
Console Port
DB-9 Port
aaa
aaaaaa
aaa
HAPTER
3
| Installing the Switch
Connecting to the Console Port
CONNECTINGTOTHE CONSOLE PORT
This port is used to connect a console device to the switch through a serial cable.
The console device can be a PC or workstation running a VT-100 terminal
emulator, or a VT-100 terminal. A crossover RJ-45 to DB-9 cable is supplied with
the unit for connecting to the console port, as illustrated below. The PIN
assignments used to connect to the serial port are described below.
Figure 13: Console Cable
WIRING MAPFOR SERIAL CABLE
The serial port’s configuration requirements are as follows:
The switch is designed to be connected to 10 or 100 Mbps network cards in PCs
and servers, as well as to other switches and hubs. It may also be connected to
remote devices using optional 1000BASE-SX, 1000BASE-LX, or 1000BASE-LH
SFP transceivers.
TWISTED-PAIR DEVICES
Each device requires an unshielded twisted-pair (UTP) cable with RJ-45
connectors at both ends. Use Category 5, 5e or 6 cable for 1000BASE-T
connections, Category 5 or better for 100BASE-TX connections, and Category 3
or better for 10BASE-T connections.
CABLING GUIDELINES
The RJ-45 ports on the switch support automatic MDI/MDI-X pinout
configuration, so you can use standard straight-through twisted-pair cables to
connect to any other network device (PCs, servers, switches, routers, or hubs).
See Appendix B for further information on cabling.
C
AUTION
:
will damage the switch. Use only twisted-pair cables with RJ-45
connectors that conform to FCC standards.
Do not plug a phone jack connector into an RJ-45 port. This
– 41 –
C
HAPTER
4
Twisted-Pair Devices
| Making Network Connections
CONNECTINGTO PCS, SERVERS, HUBSAND SWITCHES
1. Attach one end of a twisted-pair cable segment to the device’s RJ-45
connector.
Figure 14: Making Twisted-Pair Connections
2. If the device is a network card and the switch is in the wiring closet, attach
the other end of the cable segment to a modular wall outlet that is
connected to the wiring closet. (See the section “Fiber Optic SFP Devices.”)
Otherwise, attach the other end to an available port on the switch.
Make sure each twisted pair cable does not exceed 100 meters (328 ft) in
length.
N
OTE
:
Avoid using flow control on a port connected to a hub unless it is
actually required to solve a problem. Otherwise back pressure jamming
signals may degrade overall performance for the segment attached to
the hub.
3. As each connection is made, the Link LED (on the switch) corresponding to
each port will light green or amber to indicate that the connection is valid.
– 42 –
C
HAPTER
4
| Making Network Connections
Fiber Optic SFP Devices
FIBER OPTIC SFP DEVICES
An optional Gigabit SFP transceiver (1000BASE-SX, 1000BASE-LX or 1000BASELH) can be used for a backbone connection between switches, or for connecting
to a high-speed server.
Each single-mode fiber port requires 9/125 micron single-mode fiber optic cable
with an LC connector at both ends. Each multimode fiber optic port requires 50/
125 or 62.5/125 micron multimode fiber optic cabling with an LC connector at
both ends.
W
ARNING
:
cable. The lasers are compliant with the requirements of a Class 1
Laser Product and are inherently eye safe in normal operation.
However, you should never look directly at a transmit port when it is
powered on.
W
make sure that it can function at a temperature that is not less than the
recommended maximum operational temperature of the product. You
must also use an approved Laser Class 1 SFP transceiver.
This switch uses lasers to transmit signals over fiber optic
ARNING
:
When selecting a fiber SFP device, considering safety, please
1. Remove and keep the LC port’s rubber plug. When not connected to a fiber
cable, the rubber plug should be replaced to protect the optics.
2. Check that the fiber terminators are clean. You can clean the cable plugs by
wiping them gently with a clean tissue or cotton ball moistened with a little
ethanol. Dirty fiber terminators on fiber optic cables will impair the quality
of the light transmitted through the cable and lead to degraded performance
on the port.
3. Connect one end of the cable to the LC port on the switch and the other end
to the LC port on the other device. Since LC connectors are keyed, the cable
can be attached in only one orientation.
– 43 –
C
27
P
o
w
e
r
D
ia
g
1
35
79
2468 10
P
o
w
e
r
D
ia
g
1
35
79
2468 10
HAPTER
4
Fiber Optic SFP Devices
| Making Network Connections
Figure 15: Making Fiber Port Connections
4. As a connection is made, check the Link LED on the switch corresponding to
the port to be sure that the connection is valid.
The 1000BASE-SX, 1000BASE-LX, 1000BASE-LH fiber optic ports operate at
1 Gbps, full duplex, with auto-negotiation of flow control. The maximum length
for fiber optic cable operating at Gigabit speed will depend on the fiber type as
listed under “1000 Mbps Gigabit Ethernet Collision Domain” on page 45.
– 44 –
C
HAPTER
4
| Making Network Connections
Connectivity Rules
CONNECTIVITY RULES
When adding hubs (repeaters) to your network, please follow the connectivity
rules listed in the manuals for these products. However, note that because
switches break up the path for connected devices into separate collision
domains, you should not include the switch or connected cabling in your
calculations for cascade length involving other devices.
1000BASE-T CABLE REQUIREMENTS
All Category 5 UTP cables that are used for 100BASE-TX connections should also
work for 1000BASE-T, providing that all four wire pairs are connected. However,
it is recommended that for all critical connections, or any new cable installations,
Category 5e (enhanced Category 5) or Category 6 cable should be used. The
Category 5e and 6 specifications include test parameters that are only
recommendations for Category 5. Therefore, the first step in preparing existing
Category 5 cabling for running 1000BASE-T is a simple test of the cable
installation to be sure that it complies with the IEEE 802.3-2005 standards.
1000 MBPS GIGABIT ETHERNET COLLISION DOMAIN
Table 6: Maximum 1000BASE-T Gigabit Ethernet Cable Length
Cable TypeMaximum Cable LengthConnector
Category 5, 5e, or 6 100-ohm UTP or STP100 m (328 ft)RJ-45
Table 7: Maximum 1000BASE-SX Gigabit Ethernet Cable Lengths
10BASE-TCategory 3 or better 100-ohm UTP100 m (328 ft)RJ-45
– 46 –
C
HAPTER
4
| Making Network Connections
Cable Labeling and Connection Records
CABLE LABELINGAND CONNECTION RECORDS
When planning a network installation, it is essential to label the opposing ends of
cables and to record where each cable is connected. Doing so will enable you to
easily locate inter-connected devices, isolate faults and change your topology
without need for unnecessary time consumption.
To best manage the physical implementations of your network, follow these
guidelines:
◆Clearly label the opposing ends of each cable.
◆Using your building’s floor plans, draw a map of the location of all network-
connected equipment. For each piece of equipment, identify the devices to
which it is connected.
◆Note the length of each cable and the maximum cable length supported by
the switch ports.
◆For ease of understanding, use a location-based key when assigning
prefixes to your cable labeling.
◆Use sequential numbers for cables that originate from the same equipment.
◆Differentiate between racks by naming accordingly.
◆Label each separate piece of equipment.
◆Display a copy of your equipment map, including keys to all abbreviations at
each equipment rack.
– 47 –
C
HAPTER
4
Cable Labeling and Connection Records
| Making Network Connections
– 48 –
ATROUBLESHOOTING
DIAGNOSING SWITCH INDICATORS
Table 12: Troubleshooting Chart
SymptomAction
Power LED is Off
Power LED is on
Amber
DIAG LED On Amber
Link LED is Off
◆Check connections between the switch, the power cord and
the wall outlet.
◆Contact your dealer for assistance.
◆Contact your local dealer for assistance.
◆Power cycle the switch to try and clear the condition.
◆If the condition does not clear, contact your dealer for
assistance.
◆Verify that the switch and attached device are powered on.
◆Be sure the cable is plugged into both the switch and
corresponding device.
◆If the switch is installed in a rack, check the connections to
the punch-down block and patch panel.
◆Verify that the proper cable type is used and its length does
not exceed specified limits.
◆Check the adapter on the attached device and cable
connections for possible defects. Replace the defective
adapter or cable if necessary.
– 49 –
A
PPENDIX
Power and Cooling Problems
A
| Troubleshooting
POWERAND COOLING PROBLEMS
If the power indicator does not turn on when the power cord is plugged in, you
may have a problem with the power outlet, power cord, or internal power
supply. However, if the unit powers off after running for a while, check for loose
power connections, power losses or surges at the power outlet. If you still
cannot isolate the problem, the internal power supply may be defective.
INSTALLATION
Verify that all system components have been properly installed. If one or more
components appear to be malfunctioning (such as the power cord or network
cabling), test them in an alternate environment where you are sure that all the
other components are functioning properly.
IN-BAND ACCESS
You can access the management agent in the switch from anywhere within the
attached network using Telnet, a web browser, or other network management
software tools. However, you must first configure the switch with a valid IP
address, subnet mask, and default gateway. If you have trouble establishing a
link to the management agent, check to see if you have a valid network
connection. Then verify that you entered the correct IP address. Also, be sure
the port through which you are connecting to the switch has not been disabled.
If it has not been disabled, then check the network cabling that runs between
your remote location and the switch.
N
OTE
:
The management agent accepts up to four simultaneous Telnet
sessions. If the maximum number of sessions already exists, an
additional Telnet connection will not be able to log into the system.
– 50 –
BCABLES
8
1
1
8
TWISTED-PAIR CABLEAND PIN ASSIGNMENTS
For 10/100BASE-TX connections, the twisted-pair cable must have two pairs of
wires. For 1000BASE-T connections the twisted-pair cable must have four pairs
of wires. Each wire pair is identified by two different colors. For example, one
wire might be green and the other, green with white stripes. Also, an RJ-45
connector must be attached to both ends of the cable.
C
AUTION
:
only twisted-pair cables with RJ-45 connectors that conform with FCC
standards.
C
specific orientation.
The figure below illustrates how the pins on the RJ-45 connector are numbered.
Be sure to hold the connectors in the same orientation when attaching the wires
to the pins.
DO NOT plug a phone jack connector into any RJ-45 port. Use
AUTION
:
Each wire pair must be attached to the RJ-45 connectors in a
Figure 16: RJ-45 Connector Pin Numbers
– 51 –
A
PPENDIX
Twisted-Pair Cable and Pin Assignments
B
| Cables
10BASE-T/100BASE-TX PIN ASSIGNMENTS
Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for RJ-45
connections: 100-ohm Category 3 or better cable for 10 Mbps connections, or
100-ohm Category 5 or better cable for 100 Mbps connections. Also be sure
the length of any twisted-pair connection does not exceed 100 meters (328 feet).
The RJ-45 ports on the switch base unit support automatic MDI/MDI-X
operation, so you can use straight-through cables for all network connections to
PCs or servers, or to other switches or hubs. In straight-through cable, pins 1, 2,
3, and 6, at one end of the cable, are connected straight through to pins 1, 2, 3,
and 6 at the other end of the cable. When using any RJ-45 port on this switch,
you can use either straight-through or crossover cable.
Table 13: 10/100BASE-TX MDI and MDI-X Port Pinouts
PinMDI Signal NameMDI-X Signal Name
1Transmit Data plus (TD+)Receive Data plus (RD+)
2Transmit Data minus (TD-)Receive Data minus (RD-)
3Receive Data plus (RD+)Transmit Data plus (TD+)
6Receive Data minus (RD-)Transmit Data minus (TD-)
4,5,7,8Not usedNot used
Note:The “+” and “-” signs represent the polarity of the wires that
make up each wire pair.
that
STRAIGHT-THROUGH WIRING
If the twisted-pair cable is to join two ports and only one of the ports has an
internal crossover (MDI-X), the two pairs of wires must be straight-through.
(When auto-negotiation is enabled for any RJ-45 port on this switch, you can
use either straight-through or crossover cable to connect to any device type.)
You must connect all four wire pairs as shown in the following diagram to
support Gigabit Ethernet.
– 52 –
A
White/Orange Stripe
Orange
White/Green Stripe
Green
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
EIA/TIA 568B RJ-45 Wiring Standard
10/100BASE-TX Straight-through Cable
End A
End B
Blue
White/Blue Stripe
Brown
White/Brown Stripe
White/Orange Stripe
Orange
White/Green Stripe
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
EIA/TIA 568B RJ-45 Wiring Standard
10/100BASE-TX Crossover Cable
End A
End B
Green
Blue
White/Blue Stripe
Brown
White/Brown Stripe
Twisted-Pair Cable and Pin Assignments
PPENDIX
B
| Cables
Figure 17: Straight-through Wiring
CROSSOVER WIRING
If the twisted-pair cable is to join two ports and either both ports are labeled
with an “X” (MDI-X) or neither port is labeled with an “X” (MDI), a crossover
must be implemented in the wiring. (When auto-negotiation is enabled for any
RJ-45 port on this switch, you can use either straight-through or crossover cable
to connect to any device type.)
You must connect all four wire pairs as shown in the following diagram to
support Gigabit Ethernet.
Figure 18: Crossover Wiring
– 53 –
A
PPENDIX
Twisted-Pair Cable and Pin Assignments
B
| Cables
1000BASE-T PIN ASSIGNMENTS
All 1000BASE-T ports support automatic MDI/MDI-X operation, so you can use
straight-through cables for all network connections to PCs or servers, or to other
switches or hubs.
The table below shows the 1000BASE-T MDI and MDI-X port pinouts. These
ports require that all four pairs of wires be connected. Note that for 1000BASE-T
operation, all four pairs of wires are used for both transmit and receive.
Use 100-ohm Category 5, 5e or 6 unshielded twisted-pair (UTP) or shielded
twisted-pair (STP) cable for 1000BASE-T connections. Also be sure
length of any twisted-pair connection does not exceed 100 meters (328 feet)
Table 14: 1000BASE-T MDI and MDI-X Port Pinouts
Pin MDI Signal NameMDI-X Signal Name
1Bi-directional Pair A Plus (BI_DA+)Bi-directional Pair B Plus (BI_DB+)
2Bi-directional Pair A Minus (BI_DA-)Bi-directional Pair B Minus (BI_DB-)
3Bi-directional Pair B Plus (BI_DB+)Bi-directional Pair A Plus (BI_DA+)
4Bi-directional Pair C Plus (BI_DC+)Bi-directional Pair D Plus (BI_DD+)
5Bi-directional Pair C Minus (BI_DC-)Bi-directional Pair D Minus (BI_DD-)
6Bi-directional Pair B Minus (BI_DB-)Bi-directional Pair A Minus (BI_DA-)
7Bi-directional Pair D Plus (BI_DD+)Bi-directional Pair C Plus (BI_DC+)
8Bi-directional Pair D Minus (BI_DD-)Bi-directional Pair C Minus (BI_DC-)
that the
.
CABLE TESTINGFOR EXISTING CATEGORY 5 CABLE
Installed Category 5 cabling must pass tests for Attenuation, Near-End Crosstalk
(NEXT), and Far-End Crosstalk (FEXT). This cable testing information is specified
in the ANSI/TIA/EIA-TSB-67 standard. Additionally, cables must also pass test
parameters for Return Loss and Equal-Level Far-End Crosstalk (ELFEXT). These
tests are specified in the ANSI/TIA/EIA-TSB-95 Bulletin, “The Additional
Transmission Performance Guidelines for 100 Ohm 4-Pair Category 5 Cabling.”
Note that when testing your cable installation, be sure to include all patch cables
between switches and end devices.
– 54 –
A
PPENDIX
B
| Cables
Fiber Standards
ADJUSTING EXISTING CATEGORY 5 CABLINGTO RUN 1000BASE-T
If your existing Category 5 installation does not meet one of the test parameters
for 1000BASE-T, there are basically three measures that can be applied to try
and correct the problem:
1. Replace any Category 5 patch cables with high-performance Category 5e or
Category 6 cables.
2. Reduce the number of connectors used in the link.
3. Reconnect some of the connectors in the link.
FIBER STANDARDS
The International Telecommunication Union (ITU-T) has standardized various
fiber types for data networks. These are summarized in the following table.
Table 15: Fiber Standards
ITU-T
Standard
G.651Multimode Fiber
G.652Non-Dispersion-Shifted Fiber
G.652.CLow Water Peak Non-
G.653Dispersion-Shifted Fiber
DescriptionApplication
50/125-micron core
Single-mode, 9/125-micron core
Dispersion-Shifted Fiber
Single-mode, 9/125-micron core
Single-mode, 9/125-micron core
– 55 –
Short-reach connections in the 1300nm or 850-nm band
Longer spans and extended reach.
Optimized for operation in the 1310nm band. but can also be used in the
1550-nm band
Longer spans and extended reach.
Optimized for wavelength-division
multiplexing (WDM) transmission
across wavelengths from 1285 to
1625 nm. The zero dispersion
wavelength is in the 1310-nm region.
Longer spans and extended reach.
Optimized for operation in the region
from 1500 to 1600-nm.
A
PPENDIX
Fiber Standards
Table 15: Fiber Standards (Continued)
B
| Cables
ITU-T
Standard
G.6541550-nm Loss-Minimized Fiber
G.655Non-Zero Dispersion-Shifted
DescriptionApplication
Single-mode, 9/125-micron core
Fiber
Single-mode, 9/125-micron core
Extended long-haul applications.
Optimized for high-power
transmission in the 1500 to 1600-nm
region, with low loss in the 1550-nm
band.
Extended long-haul applications.
Optimized for high-power dense
wavelength-division multiplexing
(DWDM) operation in the region from
1500 to 1600-nm.
– 56 –
CSPECIFICATIONS
PHYSICAL CHARACTERISTICS
PORTS
8 10/100BASE-TX, with auto-negotiation
2 10/100/1000BASE-T, shared with two SFP transceiver slots
NETWORK INTERFACE
Ports 1-10: RJ-45 connector, auto MDI/X
10BASE-T: RJ-45 (100-ohm, UTP cable; Category 3 or better)
100BASE-TX: RJ-45 (100-ohm, UTP cable; Category 5 or better)
1000BASE-T: RJ-45 (100-ohm, UTP or STP cable; Category 5, 5e or 6)
*Maximum Cable Length - 100 m (328 ft)
BUFFER ARCHITECTURE
4 Mbit packet buffer
AGGREGATE BANDWIDTH
5.6 Gbps
SWITCHING DATABASE
8K MAC address entries
LEDS
System: Power, DIAG (Diagnostic),
status (link, speed, and activity)
Port:
– 57 –
A
PPENDIX
Physical Characteristics
C
| Specifications
WEIGHT
0.72 kg (1.59 lbs)
SIZE
(W x D x H): 195 mm x 115 mm x 36 mm (7.68 x 4.53 x 1.42 inches)
TEMPERATURE
Operating: 0°C to 45°C (32°F to 113°F)
Storage: -40°C to 70°C (-40°F to 158°F)
HUMIDITY
Operating: 10% to 90% (non-condensing)
AC INPUT
100 to 240 V, 50-60 Hz, 0.2A
POWER SUPPLY
Internal, auto-ranging transformer: 100 to 240 VAC, 50 to 60 Hz
POWER CONSUMPTION
32 Watts maximum
MAXIMUM CURRENT
0.25 A @ 100 VAC
0.12 A @ 240 VAC
– 58 –
SWITCH FEATURES
FORWARDING MODE
Store-and-forward
THROUGHPUT
Wire speed
FLOW CONTROL
Full Duplex: IEEE 802.3x
Half Duplex: Back pressure
MANAGEMENT FEATURES
A
PPENDIX
C
| Specifications
Switch Features
IN-BAND MANAGEMENT
SSH, Telnet, SNMP, or HTTP
OUT-OF-BAND MANAGEMENT
RS-232 RJ-45 console port
SOFTWARE LOADING
TFTP in-band, or XModem out-of-band
– 59 –
A
PPENDIX
Standards
C
| Specifications
STANDARDS
IEEE 802.3-2005
Ethernet, Fast Ethernet, Gigabit Ethernet
Full-duplex flow control
Link Aggregation Control Protocol
IEEE 802.1D -2004
Spanning Tree Protocol
Rapid Spanning Tree Protocol
Multiple Spanning Tree Protocol
ISO/IEC 8802-3
COMPLIANCES
EMISSIONS
EN55022 (CISPR 22) Class A
EN 61000-3-2/3
CE Mark
IMMUNITY
EN 61000-4-2/3/4/5/6/8/11
SAFETY
CB (IEC/EN60950-1)
– 60 –
GLOSSARY
10BASE-T
IEEE 802.3 specification for 10 Mbps Ethernet over two pairs of Category 3, 4, or
5 UTP cable.
100BASE-TX
IEEE 802.3u specification for 100 Mbps Ethernet over two pairs of Category 5
UTP cable.
1000BASE-LH
Specification for long-haul Gigabit Ethernet over two strands of 9/125 micron
core fiber cable.
1000BASE-LX
IEEE 802.3z specification for Gigabit Ethernet over two strands of 50/125, 62.5/
125 or 9/125 micron core fiber cable.
1000BASE-SX
IEEE 802.3z specification for Gigabit Ethernet over two strands of 50/125 or
62.5/125 micron core fiber cable.
1000BASE-T
IEEE 802.3ab specification for Gigabit Ethernet over 100-ohm Category 5, 5e or
6 twisted-pair cable (using all four wire pairs).
AUTO-NEGOTIATION
Signalling method allowing each node to select its optimum operational mode
(e.g., speed and duplex mode) based on the capabilities of the node to which it
is connected.
– 61 –
G
LOSSARY
BANDWIDTH
The difference between the highest and lowest frequencies available for network
signals. Also synonymous with wire speed, the actual speed of the data
transmission along the cable.
COLLISION DOMAIN
Single CSMA/CD LAN segment.
CSMA/CD
CSMA/CD (Carrier Sense Multiple Access/Collision Detect) is the communication
method employed by Ethernet, Fast Ethernet, and Gigabit Ethernet.
END STATION
A workstation, server, or other device that does not forward traffic.
ETHERNET
A network communication system developed and standardized by DEC, Intel,
and Xerox, using baseband transmission, CSMA/CD access, logical bus topology,
and coaxial cable. The successor IEEE 802.3 standard provides for integration
into the OSI model and extends the physical layer and media with repeaters and
implementations that operate on fiber, thin coax and twisted-pair cable.
FAST ETHERNET
A 100 Mbps network communication system based on Ethernet and the CSMA/
CD access method.
FULL DUPLEX
Transmission method that allows two network devices to transmit and receive
concurrently, effectively doubling the bandwidth of that link.
GIGABIT ETHERNET
A 1000 Mbps network communication system based on Ethernet and the CSMA/
CD access method.
– 62 –
G
LOSSARY
IEEE
Institute of Electrical and Electronic Engineers.
IEEE 802.3
Defines carrier sense multiple access with collision detection (CSMA/CD) access
method and physical layer specifications.
IEEE 802.3AB
Defines CSMA/CD access method and physical layer specifications for
1000BASE-T Gigabit Ethernet. (Now incorporated in IEEE 802.3-2005.)
IEEE 802.3U
Defines CSMA/CD access method and physical layer specifications for 100BASETX Fast Ethernet. (Now incorporated in IEEE 802.3-2005.)
IEEE 802.3X
Defines Ethernet frame start/stop requests and timers used for flow control on
full-duplex links. (Now incorporated in IEEE 802.3-2005.)
IEEE 802.3Z
Defines CSMA/CD access method and physical layer specifications for 1000BASE
Gigabit Ethernet. (Now incorporated in IEEE 802.3-2005.)
LAN SEGMENT
Separate LAN or collision domain.
LED
Light emitting diode used for monitoring a device or network condition.
LOCAL AREA NETWORK (LAN)
A group of interconnected computer and support devices.
– 63 –
G
LOSSARY
MEDIA ACCESS CONTROL (MAC)
A portion of the networking protocol that governs access to the transmission
medium, facilitating the exchange of data between network nodes.
MIB
An acronym for Management Information Base. It is a set of database objects
that contains information about the device.
MODAL BANDWIDTH
Bandwidth for multimode fiber is referred to as modal bandwidth because it
varies with the modal field (or core diameter) of the fiber. Modal bandwidth is
specified in units of MHz per km, which indicates the amount of bandwidth
supported by the fiber for a one km distance.
NETWORK DIAMETER
Wire distance between two end stations in the same collision domain.
RJ-45 CONNECTOR
A connector for twisted-pair wiring.
SWITCHED PORTS
Ports that are on separate collision domains or LAN segments.
TIA
Telecommunications Industry Association
TRANSMISSION CONTROL PROTOCOL/INTERNET PROTOCOL (TCP/IP)
Protocol suite that includes TCP as the primary transport protocol, and IP as the
network layer protocol.
USER DATAGRAM PROTOCOL (UDP)
UDP provides a datagram mode for packet-switched communications. It uses IP
as the underlying transport mechanism to provide access to IP-like services.
– 64 –
G
LOSSARY
UDP packets are delivered just like IP packets – connection-less datagrams that
may be discarded before reaching their targets. UDP is useful when TCP would
be too complex, too slow, or just unnecessary.
UTP
Unshielded twisted-pair cable.
VIRTUAL LAN (VLAN)
A Virtual LAN is a collection of network nodes that share the same collision
domain regardless of their physical location or connection point in the network.
A VLAN serves as a logical workgroup with no physical barriers, allowing users to
share information and resources as though located on the same LAN.
Fast Ethernet connectivity rules 46
features 59
fiber cables 43
flow control, IEEE 802.3x 23
front panel of switch 21
full duplex connectivity 27
G
Gigabit Ethernet cable lengths 45
I
IEEE 802.3x flow control 23
indicators, LED 24
installation
connecting devices to the switch
desktop or shelf mounting 35
network wiring connections 43
port connections 41, 43
power requirements 33
problems 50
rack mounting 35
site requirements 33
L
laser safety 43
LC port connections 43
LED indicators
location requirements 33
25
DIAG
PWR 25
42
– 67 –
I
NDEX
M
management
mounting the switch
multimode fiber optic cables 43
22
agent
features 59
out-of-band 22
SNMP 22
web-based 22
in a rack
on a desktop or shelf 35
35
N
network
connections
examples 28
41, 43
O
out-of-band management 22
P
package contents 35
pin assignments 51
1000BASE-T 54
10BASE-T/100BASE-TX 52
console port 39, 40
port saturation 23
ports, connecting to 41, 43
power, connecting to 38
specifications
compliances
environmental 58
power 58
standards
compliance
IEEE 60
status LEDs 24
surge suppressor, using 33
switch architecture 22
switching method 22
60
60
T
Telnet 50
troubleshooting
in-band access
power and cooling problems 50
twisted-pair connections 41
50
V
VLANS, tagging 31
W
web-based management 22
R
rack mounting 35
rear panel of switch 21
rear panel socket 26
RJ-45 port 23