Microsens MS400240, MS400241, MS400249 User Manual

1
Introduction
This 2-port Gigabit Ethernet Bridging Converter is ideal to couple copper and fiber optic segments in an Ethernet network. The device has one 10/100/1000Base-T (RJ-
45) port and one Fiber Port according to 1000Base-X. There are versions with build in transceiver for Multimode and Single Mode fibers or optional a version with a SFP slot for pluggable transceivers available.
Packing list
Please check the following items in the package before installing the Bridging Converter: Gigabit Ethernet Bridging Converter 1 pc. AC/DC adapter 1 pc. User manual 1 pc. Please contact your reseller immediately for any loss or damage to the above items.
Installation
RJ-45 interface: The transmission media supports min. CAT5 twisted­pair cable with a maximum length of 100 meter. It supports auto-negotiation feature with automatic detection of the speed (10/100/1000 Mbps), the duplex mode and auto-crossing (MDI/MDIX).
Fiber interface: Available as duplex or simplex SC. The duplex version includes two connectors, labelled TX (transmit) and RX (receive). The connection between two duplex fiber ports has to be crossed, so the connection has to be RX­TX and TX-RX.
Connection
The network device (e.g. PC, Switch, Access Point) with copper interface is connected to RJ-45 port of the Bridging Converter through a twisted-pair cable. The Multi or Single Mode fiber cable is connected to SC fiber interface (optional to the SFP transceiver). After powering on the Bridging Converter, the LEDs should show correct connections by the corresponding Link LED. (See the table below for the LED description).
Fixed SC Transceiver Version
Pluggable SFP Transceiver Version
Drawing of LEDs DIP Switches
Description for LEDs
LED indicator lamps serve as device monitoring and for trouble shooting. The functions of the LEDs are described in the following table.
LED
Status
Function
PWR
On
Ready for operation
1000M
On
RJ-45 with 1000 Mbps
Off
RJ-45 with 10/100 Mbps
LINK/ACT
(FX)
On
Link at fiber port
Flashing
Data activity on fiber port
Off
No connection at fiber port
LINK/ACT
(TX)
On
Link at RJ-45 port
Flashing
Data activity on RJ-45 port
Off
No connection at RJ-45 port
SD
On
Fiber signal detected
Off
No fiber signal detected
FDX/COL
(TX)
On
RJ-45 connection full duplex
Off
RJ-45 connection half duplex
2
Technical Specifications optical transceiver simplex:
Version
Optical wavelength (nm)
Optical power (dBm)
Sensitivity (dBm)
Distance (km) TP/SM simplex
1310/1550
-3..-8
<-22
20
TP/SM simplex
1310/1550
0..-5
<-24
40
TP/SM simplex
1310/1550
0..-3
<-25
60
Technical Specifications optical transceiver duplex:
Version
Optical wavelength (nm)
Optical power (dBm)
Sensitivity (dBm)
Distance (km) TP/MM
850
-12..-15
<-20
0.55
TP/SM 20
1310
-3..-8
<-22
20
TP/SM 40
1310
0..-5
<-24
40
TP/SM 60
1310
0..-3
<-25
60
TP/SM 80
1550DFB
0..-1
<-25
80
DIP-Switch configuration:
Switch
Status
Function
1 On
Link Through on
Off
Link Through off
2 On
Not used
Off
Not used
3 On/Off
Copper port forced to 10Mb
On/On
10/100/1000T adaptive
4 On
Not used
Off
Not used
Main features:
Compact Gigabit Ethernet Bridging Converter
Compliant to IEEE 802.3, 802.3u, and 802.3x,
IEEE 802.3ab 1000BaseT, IEEE 802.3z Standards
Integrated Link-Through function (links status forwarding)
Automatic configuration via auto-negotiation
Manual configuration via DIP-switches possible
Integrated auto-crossing (MDI/MDIX) on RJ-45 port
Technical Specifications:
Type: Gigabit Ethernet Bridging Converter for coupling
of twisted-pair (10/100/1000Base-T) and fiber (1000Base-X)
Cable type: Shielded twisted-pair cable, 100 Ohm, min. Cat 5e Fiber type: Multimode fiber 50 or 62,5/125 µm, Single Mode
fiber 9/125 µm, duplex SC-connector (optional SC simplex), optional SFP slot for pluggable transceivers Power supply: 5 V DC / max. 1 A via external power supply (included at delivery)
Operating temperature: 0 °C to 50 °C Storage temperature: -20 °C to 80 °C Humidity: 5 % to 90 % non-condensing Dimensions: 26 x 70 x 94 mm (H x B x T)
Products
Article-No
Description
MS400240
Gigabit Ethernet Bridge 10/100/1000Base-T to 1000Base-SX SC, 850 nm Multimode
MS400241
Gigabit Ethernet Bridge 10/100/1000Base-T to 1000Base-LX SC, 1310 nm Single Mode
MS400249
Gigabit Ethernet Bridge 10/100/1000Base-T to 1000Base-X, SFP Slot
Gigabit Ethernet
Bridging Converter
User Manual
(Do not use this device until you read
this manual carefully!)
MICROSENS GmbH & Co. KG – Kueferstr. 16 - 59067 Hamm / Germany
Tel. +49 23 81/94 52-0 - FAX -100 - www.microsens.com
Loading...