Microsens MS400220 User Manual

10/100/1000Base-T to 1000Base-FX
Switch Converter
User Guide
Rev.1.02
i
Content
Introduction ................................................................................................................... 1
FEATURES ...................................................................................................................... 2
PACKAGE CONTENTS ...................................................................................................... 4
Hardware Description ................................................................................................... 5
FRONT PANEL ................................................................................................................. 5
REAR PANEL ................................................................................................................... 6
PORTS ........................................................................................................................... 7
LED INDICATORS ............................................................................................................ 7
DIP-SWITCH ................................................................................................................... 8
Converter module Installation ..................................................................................... 10
CABLING ....................................................................................................................... 11
Troubleshooting .......................................................................................................... 12
1

Introduction

The Giga Fiber Converter has two types of module package; one is stand alone
converter module. And another one is mounted in converter chassis converter module.
The Giga Fiber Converter is a cost- effective solution for the converting
10/100/1000Base-TX (Auto MDI/MDIX) and pure 1000 Base-T to 1000Base-FX cabling. It can be slotted in Multi-Converter Chassis on up to 10 optional mo dular converter units, which allows your network connectivity to be more flexible. It als o can use stand-alone without slot in Multi-Converter Chassis.
The Giga Fiber Converter will allow you to extend the cabling distance of your
10/100/1000BaseTX (Auto MDI/MDIX) or pure 1000 Base-T network up to 550m for multi-mode fiber or 10 kilometers for single-mode fiber. The Giga Fiber Converter gives you the option to choose from the most popular fiber cabling connectors: SC multi- mode fiber connect or and SC single-mode fiber connector. The Modular Giga Fiber Converters provides you with one Fiber connector for your fiber optic cable and one Ethernet RJ-45 port (Auto MDI/MDIX) for your 10/100/1000BaseTX copper cable or pure 1000 Base-T copper cable connection. There are DIP- switches to set the operation mode for UTP, Fiber ports and link lost forwarding function.
2
IEEE 802.3 10BASE-T
Power (Green)
Fiber
Fiber Core: Multi-Mode (62.5/125um, 50/125um)
Link Lose
CopperFiber: If copper port link down, then media

Features

IEEE 802.3u 100BASE-TX
Standard
LED Indicators
Connector
IEEE 802.3ab 1000BaseT, IEEE 802.3z 1000BaseSX/LX standards IEEE 802.3x Flow Control and Back pressure
UTP SPD: 1000Mbps /100Mbps Lnk/Act: UTP /FIBER FDX: UTP: Full-Duplex mode / Half-Duplex or Link down
FIBER: Full-Duplex mode / Link down
Fiber: Duplex SC/MINI GBIC 3.3V/ WDM RJ-45 Socket: CAT-5e (10/100/1000Mbps) Twisted Pair
cable Auto MDI/MDI-X and Auto-Negotiation Function Support
parameters
Single-Mode (9/125um) Wavelength: 850nm(Multi-mode), 1310nm(Single-mode)/1310nm(WDM, TX), 1550nm(WDM, RX) Fiber Distance: 550M (Multi-Mode Fiber) 10 KM (Single-Mode Fiber) WDM (Single-mode) 10KM, 20KM
Forward
converter will force fiber to link down. FiberCopper: If Fiber port link down, the media converter will force copper port to link down.
3
16Kbyte(Pure converter mode)/
Power
Stand-alone (external adapter):DC 12V / 1A
Operating
Storage
Storage Dimensions
120mm x 85mm x 26mm
Switch architecture
Jumbo Frame
Power Consumption
Store and Forward
2Kbyte(Switch converter mode)
2.7 Watts(max)
Operating Temperature
Humidity
environment
Humidity
O to 45 (32 to 113)
10% to 90%
-40~70
10% to 90%
EMI
CE
4

Package Contents

Beware of which type of converter module that you have purchased. And, please refer to the package content list below to verify them against the checklist.
Stand-alone converter module package contains following items.
The Giga Fiber Converter  AC-DC Power Adapter  User Guide  Rack mount ear (only for converter chassis)
Compare the contents of your Converter with the standard checklist above. If any item is damaged or missing, please contact your local dealer for service.
5

Hardware Description

The Giga Fiber Converter dimension (L x W x H): 120mm x 85mm x 26mm

Front Panel

10/100/1000Base-T to 1000Base-FX converter module The Front Panel of the 10/100/1000Base-T to 1000Base-FX converter module
consists of one Giga Fiber port, one copper Port (Auto MDI/MDIX), and 6 LED Indicators (SPD, LK/ACT, FDX, Fiber LK/ACT, FDX/COL, and PWR).
6
DC IN
(1) RJ-45 Port (3) DIP-Switch (2) LED (4) Fiber Connector

Rear Panel

The rear panel contains a power socket. This power socket accepts DC12V voltage and minimum 1A supplied current.
7
PWR
Green
Power on
Green
1000Mbps UTP Speed
Amber
100Mbps UTP Speed
OFF
10Mbps UTP Speed
Off
Link down

Ports

Copper Port (Auto MDI/MDIX) of 10/100/1000Base-T to 1000Base-FX converter
module: The Ethernet ports will auto-sense for 10Base-T, 100Base-TX, or
1000Base-T connections. Auto MDI/MDIX means that you can connect to another Switch or workstation without changing non-crossover or crossover cabling.
Fiber Port: This port is for 1000Base-FX connections. We provide different styles of
fiber connectors (SC/SC single-mode) to meet your needs.

LED Indicators

There are 6 diagnostic LEDs located on the Front panel of converter module. They provide real-time information of system and optional status. The following table provides description of the LED status and their meanings for Modular Giga Fiber Converter.
10/100/1000Base-T to 1000Base-FX converter module
LED Status Meaning
SPD
LNK/ACT (UTP)
Green Link up
Blinks Transmitting
8
S/W No
Status
Description
ON
LLF Enable
OFF
LLF Disable
ON
Pure converter mode
OFF
Switch converter mode
ON
Reserved
OFF
Reserved
Amber Full-duplex mode
FDX (UTP)
Off Half-duplex mode or link down
Green Link up
LNK/ACT (Fiber)
FDX/COL (Fiber)
Blinks Transmitting
Off Link down
Amber Full-duplex mode
Off Link down

DIP-switch

The DIP-switch is used to configure operation mode for LLF (Link Lost Forwarding) and operation mode for Copper/Fiber port. The default value of Dipswitch is OFF.
10/100/1000Base-T to 1000Base-FX converter module
1
2
3
Link Lost Forwarding: When LLF is enabled, it will allow copper port link failure to be reported to the Fiber side and als o allow Fiber link failure to be reported to the copper side. Therefore, a link loss forward feature is provided in both copper and Fiber side.
Pure Converter mode: When pure converter mode is enabling (on), it operates with the minimum latency. The transmission flow does not wait until entire frame is ready,
9
but instead it forwards the received data immediately after the data being received. And TP port should be forced at 1000M in this application. When DIP-Switch is in Switch Converter mode (off), the converter function is same as Switch Hub.
[Note] a) Please don’t change the DIP-switch setting when copper or fiber port is transmitting or receiving data. It may cause some data error. b) Please power off then power on when you change the DIP-switch setting.
10

Converter module Installation

This installation is only for mounted in converter chassis conver ter module. You can follow the steps below to install modular converters. A. Remove the blank bracket by rotating thumbscrew counterclockwise. Put the blank
bracket aside, but don’t discard blanket bracket.
B. Open the rack mount ear kit. The kit contains two-rack mount ear (with thumbscrew)
and four screws.
C. Attach rack mount ear on both sides of the modular converter by using a
screwdriver to secure the rack mount ears.
D. Install the modular converter by inserting it into the guides and sliding it in until it
stops. Press it firmly until the power plug in the chassis plugs into the modular converter receptacle. Slide the modular converter in smoothly.
E. Gently push the thumbscrews in and turn clockwise to tighten. Do not over tighten
the thumbscrews.
11

Cabling

Using four twisted-pair, Category 5e cabling for copper port connection. The cable
between the converter and the link partner (switch, hub, workstation, etc.) must be less than 100 meters (328 ft.) long.
Fiber segment using single-mode connector type must use 9/125 μm
single-mode fiber cable. You can connect two devices in the distance of 10 Kilometers in full duplex operation. For half-duplex oper ation, the recommended maximum distance is 412 meters (1,352 ft.)
Fiber segment using multi-mode connector type must use 50 or 62.5/125 um
multi-mode fiber cable. You can connect two devices up to 550m distances.
12

Troubleshooting

Check the configuration DIP-switch. It must be setting in the same operation
mode with the link partner.
Select the proper Copper/Fiber cable to construct your network. The single-mode
converter must use single-mode fiber cable. Please check that you are using t he right cable.
Don’t mix multi-mode and single mode.