Microsens Media Converter User Manual

Overview
Media Converter/Signal Repeater module is a part of MICROSENS 10G Transport Platform, a high performance and flexible carrier-class transmission system. The 10G Transport Platform enables increasing transport capacitities in CWDM, DWDM and SDH networks. The use of wide range TDM modules permits to reduce the number of necessary wavelengths and to decrease the overall cost of the application. Ethernet over SDH modules enable using exisiting SONET/SDH infractructure for IP transmission.
19“ 2U Chassis with 5 module slots and management card
Max. 5x single size modules f.ex. 2x double size + 1x single size module
Hot swappable modules & power supplies
Redundant power supplies with -48 VDC input (opt. 230 VAC)
Exchangeable air- and filter module
Wide range of functional xWDM and TDM modules available
The functional modules of 10G Transport Platform include:
TDM 8x GBE or 8x GFC to 10G/OC-192/STM-64
TDM 5x GBE or 5x 2GFC to OC-192/STM-64
TDM 4x OC-48/STM-16 to 10G/OC-192/STM-64
TDM 2x GBE and 2x GFC to OC-48/STM-16
10G transponder with 3R, XFP and fixed Laser Versions
10G protocol converter 10G LAN to 10G WAN (OC-192/STM-64)
DWDM MUX/DeMUX, OADMs, EDFAs
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
MICROSENS
Media Converter/Signal Repeater
Module
Media Converter/Signal Repeater page 2/29
Introduction
Media Converter/Signal Repeater range is a MICROSENS 10G Transport Platform allowing Media conversation and Retiming, Reshaping and Retransmission of the signal from 155 Mb/s up to 2.5 Gb/s.
Features
Media Converter
Signal repeater with 3R functions:
Retiming
Reshaping
Retransmitting
Supports the following protocols:
OC-3/STM1
OC-12/STM4
OC-48/STM16
GbE
1GFC
2GFC
Fast Ethernet
OC-3/STM1-FEC
OC-12/STM4-FEC
OC-48/STM16-FEC
SFP for Line 1 and Line 2 physical interface
Digital Diagnostic Monitoring information from SFP
System description
The block diagram for the MS430580M is given in Figure 1. The MS430580M is a bi­directional device that offers twice the same media convertion/regeneration functionnality
From one interface input signal (Line 1 or Line 2) to one interface output signal
(Line 2 or Line 1).
The MS430580M includes also several sections composed of
Controller block, providing interfacing to the MS module series chassis controller
board hosting the SNMP Agent.
Power supplies: generates different internal power supplies from the -48V of the
MICROSENS chassis backplane
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater page 3/29
Front panel LEDs indicating the status of the interfaces and the MS430580M
common functions
Figure 1: MS430580M Block diagram.
Media converter / Regeneration description
The received signal is first converted from optical signal to electrical signal through the SFP interface. Then the electrical signal is converted to an optical signal through the second SFP interface. These two conversions (optical to electrical and then electrical to optical) perform a retiming, reshaping and retransmission of the optical signal from the Line 1 (or Line 2) input to the Line 2 (or Line 1) output. Upon the SFP type used on Line 1 and Line 2, it is possible to perform, together with the signal regeneration, a media convertion (850nm to 1310nm, CWDM to DWDM, etc).
The following alarms are provided to the controller block: Line 1 and Line 2 Loss of incoming Signal Line 1 and Line 2 Laser Shutdown The following measures are provided to the controller block:
SFP temperature in °C
SFP voltage in V
SFP receive power in dBm
SFP transmit power in dBm
SFP laser pump current (bias) in mA
Clock Generation Unit
The Clock Generation Unit provides the reference clock to the Line 1 and Line 2 optical interfaces according to the parameter given by the Controller Block. The reference clock is internal to the MS430580M and has a stability of +/- 50 ppm. The Clock
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater page 4/29
Generation Unit can provide a reference clock to supLine 1 bitrate from 125 Mb/s up to
2.67 Gb/s. Therefore the MS430580M can support the following protocols:
Protocol Bitrate
Fast Ethernet 125 Mb/s
OC-3/STM1 155.52 Mb/s
OC-3/STM1-FEC 166.62 Mb/s
OC-12/STM4 622.08 Mb/s
OC-12/STM4-FEC 666.51 Mb/s
1GFC 1.0625 Gb/s
GbE 1.25 Gb/s
2GFC 2.125 Gb/s
OC48/STM16 2.448 Gb/s
OC48/STM16-FEC 2.666 Mb/s
Controller Block
The controller block is composed of a microprocessor associated with Flash and RAM memories. The controller block collects information from different functional blocks and configures the HW according to a configuration file received. The raw information (alarms, monitoring, inventory) generated by the HW are processed by the microprocessor and delivered to the MICROSENS chassis Management Board as high level consolidated data.
Interface Specifications
Line 1 and Line 2 interfaces are provided by SFP transceivers. The optical characteristics are therefore given in the data sheet of the SFPs plugged into the MS430580M module.
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater page 5/29
SNMP User Manual
Access Configuration
Certain aspects of the Line 1 and Line 2 are user modifiable. In the following procedures the modifications are indicated at bit level. Take note of your SNMP manager’s requirements. For example setting the bits 6, 3, 2 and 0 to 1 will yield the following values:
Line 1 optical interface Configuration
One object is dedicated to the Line 1 optical interface configuration:
ms430580mCfgportaTrscvCtrl
This allows the configuring of the initialisation of the Line 1 SFP laser state. Location: \microsens\modulems430580m\ms430580mConfig\ms430580mCfgStartup\ ms430580mtableclientStartup\
The following table details the meaning of each bit as well as the default values:
ms430580mCfgportaTrscvCtrl
Bit Default value Bit Name Description
Bit 0 0 Line 1 SFP Laser Off
Line 1 SFP Laser state: 0: SFP Laser ON 1: SFP Laser OFF
Bit 7-1 0000000 Reserved Set to Default value
Bit 15-8 00000000 Reserved Set to Default value
Line 2 optical interface Configuration
One object is dedicated to the Line 2 optical interface configuration:
ms430580mCfgportbTrscvCtrl
This allows the configuring of the initialisation of the Line 2 SFP laser state. Location: \microsens\modulems430580m\ms430580mConfig\ms430580mCfgStartup\ ms430580mtablelineStartup\
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater page 6/29
The following table details the meaning of each bit as well as the default values:
ms430580mCfgportbTrscvCtrl
Bit Default value Bit Name Description
Bit 0 0 Line 2 SFP Laser Off
Line 2 SFP Laser state: 0: SFP Laser ON 1: SFP Laser OFF
Bit 7-1 0000000 Reserved Set to Default value
Bit 15-8 00000000 Reserved Set to Default value
Client/Line bitrate Configuration
One object is dedicated to the client/line bitrate configuration:
ms430580mCfgbitrateSelect
This allows the configuring of the bitrate for the Line 1 and Line 2. Location: \microsens\modulems430580m\ms430580mConfig\ms430580mCfgStartup\ ms430580mtablelineStartup\
The following table details the meaning of each bit as well as the default values:
ms430580mCfgprotocolSelect
Bit Default
value
Bit Name Description
Bit 3-0 0000 Line 1 and Line 2 bitrate
Bitrate selection 0: 2.488 Gb/s (OC-48/STM16) 1: 1.25 Gb/s (GbE) 2: 622.08 Mb/s (OC-12/STM4) 3: 155.52 Mb/s (OC-3/STM1) 4: 2.125 Gb/s (2GFC) 5: 1.0625 Gb/s (1GFC) 7: 125 Mb/s (Fast Ethernet) 8: 2,666 Mb/s (OC-48/STM16-FEC) 9: 666.51 Mb/s (OC-12/STM4-FEC) 10: 166.62 Mb/s (OC-3/STM1-FEC)
Bit 7-4 0000 Reserved Set to Default value
Bit 15-8 00000000 Reserved Set to Default value
How to modify the Configuration
The following procedure outlines how to modify any configuration. This can be performed at any time, keeping in mind that the cold reset will affect the traffic.
Note This is module type dependant. Consu lt the table in the Description section to determine if it is applicable or not. The following modifications may be achieved by using control objects in: ...\microsens\modulems430580m\ms430580mcontrolsWrite\ However modifications made in this way are lost following a reset.
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater page 7/29
The Line and Client configuration modification can be performed at the same time and applied at the same time with one reset. Traffic implications will depend on your choice of reset.
Procedure
Ensure that the correct module is selected for management. Consult the object:
mgnt2GigmSelectedBoard
Location:…\microsens\mgnt2\mgnt2SNMPAgentData\ mgnt2ModulesManagement\
Change if necessary.
Determine a value corresponding to the configuration profile you require.
Perform an SNMP SET to write the value corresponding to the required
configuration profile into the SNMP agent.
Perform a SET to “on” the object:
ms430580mCfgWriteConfiguration
Location: ...\microsens\modulems430580m\ms430580mConfig\ This will load the new configuration from the SNMP agent to the modules RAM.
Transfer the new configuration into the module using the object:
ms430580mCtrlConfFlash
Location: ...\microsens\modulems430580m\ms430580mcontrolsWrite\ms430580mCtrlOther\ ms430580mCtrlsynth0\
Restart the module using a cold reset or by powering down/up to apply the
configuration modification. Reset information can be found in the Software management section.
Note At that point, configuration 2 becomes the default configuration of the MS module.
End procedure
Management
Inventory
Accessing the inventory allows the user to obtain information on the modules current hardware and software status. The objects described below may be found in: …\microsens\modulems430580m\ms430580mri\
Note Before consulting the inventory ensure that the correct module is selected. Consult the object mgnt2GigmSelectedBoard
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater page 8/29
Location… \microsens\mgnt2\mgnt2SNMPAgentData\mgnt2ModulesManagement\ Change if necessary.
The following are inventory examples:
ms430580mRinvHwPlatform This object returns information relating to the hardware platform. MICROSENS PLATFORM Vendor: MICROSENS Mnemonic: MS430580M Part Number: 2MS00072AAAA01 Serial Number: 000010 Date Code (yymmddww): 06160104
ms430580mRinvReloadInventory Setting this object triggers an inventory read from the module to the agent, (refresh).
ms430580mRinvSwPlatform Module software package description. SW PACKAGE Mnemonic: MS430580M Part Number: 5MS07000AAAA01 Release date(yymmdd): 060509 SW Part Number: 3SW07001AAAA Version Number: 02 Release date(yymmdd): 060510
ms430580mRinvPortASFP This object returns information relating to the Line 1 SFP in the Module with the following headings:
Vendor: Part Number: Revision Level: Serial Number: Date Code (yymmdd):
ms430580mRinvPortBSFP This object returns information relating to the Line 2 SFP in the Module with the following headings:
Vendor: Part Number: Revision Level: Serial Number: Date Code (yymmdd):
Alarms
In order to retrieve Alarm status information a polling mechanism must be put in place. The appearance of a trap message signals the occurrence of an Alarm.
The following table lists the possible alarms and recommended actions:
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Media Converter/Signal Repeater page 9/29
NAME DESCRIPTION ACTION
ms430580mAlmModuleGlobFailure Module Failure: This OID is set on
detection of a failure originating from the MS module
Correlate all alarms. If Alarm persists change the module.
ms430580mAlmSynUnlock Synthesizer not locked: This OID
indicates that the frequency synthesizer is not locked.
No action information only.
ms430580mAlmDefFuseA Fuse A fail: This OID indicates
that the fuse of the power input A is in fail condition
Correlate all alarms. If Alarm persists change the module.
ms430580mAlmDefFuseB Fuse B Fail: This OID indicates
that the fuse of the power input B is in fail condition
Correlate all alarms. If Alarm persists change the module.
ms430580mAlmLine1TxPwLowWng TRSCV 1 Tx Power Low
warning: Warning indicating that the transceiver output power of Line 1 is lower than the threshold value written in the transceiver EEPROM
Correlate all warnings. Carry out necessary maintenance procedures.
ms430580mAlmLine1TxPwrHighWng TRSCV 1 Tx Power High
warning: Warning indicating that the transceiver output power of Line 1 is higher than the threshold value written in the transceiver EEPROM
Correlate all warnings. Carry out necessary maintenance procedures.
ms430580mAlmLine1TxBiasLowWng TRSCV 1 Bias Low warning:
Warning indicating that the transceiver laser bias current of Line 1 is lower than the threshold value written in the transceiver EEPROM
Correlate all warnings. Carry out necessary maintenance procedures.
ms430580mAlmLine1TxBiasHighWng TRSCV 1 Bias High warning:
Warning indicating that the transceiver laser bias current of Line 1 is higher than the threshold value written in the transceiver EEPROM
Correlate all warnings. Carry out necessary maintenance procedures.
ms430580mAlmLine1TempLowWng TRSCV 1 Temp Low warning:
Warning indicating that the transceiver temperature of Line 1 is lower than the threshold value written in the transceiver EEPROM
Correlate all warnings and Alarms. Carry out necessary maintenance procedures.
ms430580mAlmLine1TempHighWng TRSCV 1 Temp High warning:
Warning indicating that the transceiver temperature of Line 1 is higher than the threshold value written in the transceiver EEPROM
Correlate all warnings. Carry out necessary maintenance procedures.
ms430580mAlmLine1RxPwrLowWng TRSCV 1 Rx Power Low
warning: Warning indicating that the transceiver input power of Line 1 is lower than the threshold value written in the transceiver EEPROM
Correlate all warnings. Carry out necessary maintenance procedures.
MICROSENS GmbH & Co. KG - Küferstraße 16 - 59067 Hamm - Tel. +49 2381/9452 0 - Fax 9452 100 - www.microsens.com
Loading...