Microsemi PowerDsine PD-9006G, PowerDsine PD-9012G, PowerDsine PD-9024G, PowerDsine PD-RPS-450, PowerDsine PD-RPS-1000 User Manual

PowerDsine PD90XXG
PD-9006G, PD-9012G & PD-9024G
PD-RPS-450 & PD-RPS-1000
User Guide
Copyright © July, 2011 Microsemi Page 2 Rev.A03 Analog Mixed Signal Group
2381 Morse Avenue, Irvine, CA 92614, USA; Phone (USA): (800) 713-4113, ROW: (949) 221-7100 Fax: (949) 756-0308
Note:
The information contained herein is believed to be accurate and reliable at the time of printing. However, due to ongoing product improvements and revisions, Microsemi cannot accept responsibility for inadvertent errors, inaccuracies, subsequent changes, or omissions of printed material.
Microsemi reserves the right to make changes to products and to their specifications as described in this document, at any time, without prior notice. Do not photocopy or reproduce this material without permission.
Disclaimer
Microsemi assumes no responsibility or liability arising from the use of Midspans, as described herein, nor does it convey any license under its patent rights or the rights of others. Applications that are described herein for any of these products are for illustrative purposes only. Microsemi makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification.
Note:
The information in this guide refers to PD-90XX series of Power over Ethernet Midspans, unless otherwise stated.
Note that Midspan is designed for indoor use only.
© 2010 Microsemi Corp.
All rights reserved.
This document is subject to change without notice.
Copyright © July, 2011 Microsemi Page 3 Rev.A03 Analog Mixed Signal Group
2381 Morse Avenue, Irvine, CA 92614, USA; Phone (USA): (800) 713-4113, ROW: (949) 221-7100 Fax: (949) 756-0308
Contents
1
FRONT MATERIAL ....................................................................................... 5
1.1 Model Numbers Definition: .............................................................................. 5
1.2 Electrical Compatibility Approvals ................................................................... 5
1.3 Safety Standard Approvals .............................................................................. 5
1.4 CE Marking ..................................................................................................... 5
2 SAFETY INFORMATION ................................................................................ 6
2.1 General Guidelines ......................................................................................... 6
2.2 Warnings ......................................................................................................... 6
2.3 Power Cord ..................................................................................................... 7
2.4 Power Cord Specifications by Country ............................................................ 8
3 ABOUT THE POWER OVER ETHERNET MIDSPAN ........................................... 9
3.1 10/100/1000BASE-TX Ports Definition .......................................................... 10
3.1.1 Data Input Ports .......................................................................... 10
3.1.2 Data and Power Output Ports ..................................................... 10
3.2 Indicators ....................................................................................................... 11
3.2.1 Power Indicator LED ................................................................... 11
3.2.2 Port Indications ........................................................................... 11
3.3 Connectors .................................................................................................... 13
4 POWER OVER ETHERNET MIDSPAN INSTALLATION ..................................... 14
4.1 Background Information ................................................................................ 14
4.2 Verifying Kit Contents .................................................................................... 14
4.3 Rack Mounting Brackets ............................................................................... 15
4.4 Installation Factors ........................................................................................ 15
Copyright © July, 2011 Microsemi Page 4 Rev.A03 Analog Mixed Signal Group
2381 Morse Avenue, Irvine, CA 92614, USA; Phone (USA): (800) 713-4113, ROW: (949) 221-7100 Fax: (949) 756-0308
4.5 Connecting Ethernet Cables ......................................................................... 16
4.6 Connecting Power Cables ............................................................................ 16
4.7 Powering Up the Unit .................................................................................... 17
5 TROUBLESHOOTING ................................................................................. 18
5.1 Preliminary Steps .......................................................................................... 18
5.2 Troubleshooting Steps .................................................................................. 19
6 SPECIFICATIONS ....................................................................................... 21
6.1 Physical Specifications ................................................................................. 21
6.2 Environmental Specifications ........................................................................ 21
6.3 Electrical Specifications ................................................................................ 22
7 POWERDSINES POWERVIEW PRO ............................................................ 24
8 POWER BACKUP AND POWER REDUNDANCY CONNECTION ........................ 26
8.1 Power Redundancy ....................................................................................... 26
8.2 Power Backup ............................................................................................... 27
8.3 Connectors.................................................................................................... 27
8.4 Connecting Backup and Redundancy Connectors ........................................ 28
8.5 Power Backup and Power Redundancy Indications ...................................... 30
Copyright © July, 2011 Microsemi Page 5 Rev.A03 Analog Mixed Signal Group
2381 Morse Avenue, Irvine, CA 92614, USA; Phone (USA): (800) 713-4113, ROW: (949) 221-7100 Fax: (949) 756-0308
1 Front Material
1.1 Model Numbers Definition:
PD-90xxG/ACDC/M/F: 2 Pairs AC and DC Input Family  PD-90xxG/DC/M: 2 Pairs DC Input Family
Where:
o xx: Represents number of ports (6, 12 or 24) o AC: Midspan has AC input o DC: Midspan has DC input, current sharing, and power backup
features between two Midspans
o M: Midspan includes PowerView Pro (refer to Section 7) o F: Midspan enabled full power on all ports
PD-RPS-AAAA: Redundant Power Supply
Where AAAA represents available power in watts.
1.2 Electrical Compatibility Approvals
PowerDsine 90XXG series complies with the following standards:
FCC Part 15; class B with FTP cabling, class A with UTP
cabling
EN 55022 (CISPR 22); class B with FTP cabling, class A
with UTP cabling
EN 55024 (CISPR 24)  Canadian ICES-003, class B
1.3 Safety Standard Approvals
PowerDsine meets the following safety standards:
UL/cUL per CSA/UL 60950-1  GS mark per IEC60950-1
1.4 CE Marking
CE marking on this product indicates this product complies with 89/336/EEC (EMC Directive) and 73/23/EEC (Low Voltage Directive).
Copyright © July, 2011 Microsemi Page 6 Rev.A03 Analog Mixed Signal Group
2381 Morse Avenue, Irvine, CA 92614, USA; Phone (USA): (800) 713-4113, ROW: (949) 221-7100 Fax: (949) 756-0308
2 Safety Information
Read the following safety information before using your Power over Ethernet Midspan unit.
2.1 General Guidelines
Read the following safety information before carrying out any installation, removal, or maintenance procedure on the Power over Ethernet Midspan. Warnings contain directions to be followed for the safety of personal and product. Follow all directions carefully.
2.2 Warnings
Read installation instructions in Section 4 before
connecting Power over Ethernet Midspan to its power source.
Read instructions in Section
4 before connecting
Midspan-to-Midspan power backup.
Midspan must use a grounded power cord, as defined in
Section
2.3.
This product relies on the building installation for short-
circuit (over-current) protection. Use only a fuse or circuit breaker not higher than 15A for 120VAC (U.S.), or 10A for 230VAC (international).
Do not work on the system, connect, or disconnect
cables during periods of lightning.
A voltage mismatch can cause equipment damage and
can pose a fire hazard. If voltage indicated on the label is different from power outlet voltage, do not connect Power over Ethernet Midspan to this outlet.
For shelf-mounted equipment, verify surface is stable and
strong enough to support equipment. Do not stack more than four Power over Ethernet Midspan units.
When disposing this product, follow all local laws and
regulations.
Copyright © July, 2011 Microsemi Page 7 Rev.A03 Analog Mixed Signal Group
2381 Morse Avenue, Irvine, CA 92614, USA; Phone (USA): (800) 713-4113, ROW: (949) 221-7100 Fax: (949) 756-0308
"DATA" and "DATA & POWER" ports of the Power over
Ethernet Midspan, are shielded RJ-45 data sockets. They cannot be used as Plain Old Telephone Service (POTS) sockets. Only connect RJ-45 data connectors to these sockets.
Associated Ethernet wiring shall be limited to the inside
of the building.
2.3 Power Cord
In case power cord is replaced, replacement must meet local requirements.
To ensure a reliable connection to an AC mains supply,
equipment provides an appliance IEC60320 inlet used for connecting a detachable power supply cord.
Power socket outlet must be located near Midspan and
easily accessible. The only way of removing power from unit is by disconnecting the power cord from the outlet
This unit operates under SELV (Safety Extra Low
Voltage) conditions, according to EN60950-1/IEC60950-
1. Conditions are maintained only if the equipment to which unit is connected also operates under SELV conditions.
Copyright © July, 2011 Microsemi Page 8 Rev.A03 Analog Mixed Signal Group
2381 Morse Avenue, Irvine, CA 92614, USA; Phone (USA): (800) 713-4113, ROW: (949) 221-7100 Fax: (949) 756-0308
2.4 Power Cord Specifications by Country
U.S.A. and Canada
Cord must be UL-approved or CSA certified.  Minimum specification for flexible cord is:
o No. 18 AWG o Type SV or SJ o Three-conductor
Cord set must have a rated current capacity
of at least 13A for, 9024G/ACDC/M/F, and PD-9024G/AC/F; and 10A for PD­9024G/ACDC/M, PD-9024G/AC, PD-9012G/ACDC/M,, PD-9012G/AC, PD-9006G/ACDC/M,, and PD-9006G/AC.
The attachment plug must be an earth-
grounding type with a NEMA 5-15P (15A, 125V) or NEMA 6-15P (15A, 250V) configuration.
Denmark Supply plug must comply with section 107-2-D1, standard
DK2-1a or DK2-5a.
Switzerland
Supply plug must comply with SEV/ASE 1011.
France and Peru
IT supplies cannot power this unit. If your supplies are an IT type, unit must be powered by 230V (2P+T) via an isolation transformer with a 1:1 ratio, and with secondary connection point labeled Neutral and connected directly to ground.
U.K Power over Ethernet Midspan is covered by General
Approval NS/G/12345/J/100003, for indirect connection to a public telecommunications system.
Copyright © July, 2011 Microsemi Page 9 Rev.A03 Analog Mixed Signal Group
2381 Morse Avenue, Irvine, CA 92614, USA; Phone (USA): (800) 713-4113, ROW: (949) 221-7100 Fax: (949) 756-0308
3 About the Power over Ethernet
Midspan
PowerDsine’s family of Power over Ethernet Midspans series 90XXG inject power over data-carrying Ethernet cabling. Employing these devices reduces the need for AC outlets, local UPS and AC/DC adapters near PDs
PD9006G/9012G/9024G Midspans support 6, 12, and 24 ports respectively, in a 10/100/1000BaseTx Ethernet network, over TIA/EIA­568 category 5/5e/6 cabling. 9000G family can provide up to 30W (or 36W in Extra Power mode) according to the new PoE standard; IEEE802.3at. DC power is fed over the spare pairs of wires within a cable (4/5 and 7/8) to terminal units.
RPS family can provide backup or additional power to PD-90xxG products.
Power over Ethernet Midspan normally powers devices that are Power over Ethernet enabled or are equipped to receive power over Ethernet. These devices are called Powered Devices (PDs).
Features of the Power over Ethernet Midspan include:
Safe and reliable power over an existing Ethernet
infrastructure
Remote management using Web control and/or SNMPv3  Highest level of network security  Safe solution that protects network infrastructure  Standards compliant: IEEE 802.3af and 802.3at  Provides safe Power + Data over a single RJ45 cable
Copyright © July, 2011 Microsemi Page 10 Rev.A03 Analog Mixed Signal Group
2381 Morse Avenue, Irvine, CA 92614, USA; Phone (USA): (800) 713-4113, ROW: (949) 221-7100 Fax: (949) 756-0308
3.1 10/100/1000BASE-TX Ports Definition
The following sections detail 9000G ports, and their functions.
3.1.1 Data Input Ports
Midspan has 6, 12 or 24 10/100/1000Base-T Data In ports, located on PoE front panel (Figure
3-1), configured in a non-crossover manner
(straight-wired).
These ports are designed to carry Ethernet data only (Tx/Rx) over:
Standard 4-wire pairs (pins 1/2, 3/6, 4/5 and 7/8)
(1000Base-T)
2-wire pairs (pins 1/2 and 3/6) (10/100Base-T)
3.1.2 Data and Power Output Ports
Midspan has 6, 12 or 24 10/100/1000Base-T Data & Power Out ports, located on the front panel (see Figure
3-1). These ports are configured in
a non-crossover manner (straight-wired) and carry Ethernet data over:
Standard 4-wire pairs (pins 1/2, 3/6, 4/5, and 7/8)
(1000Base-T)
2-wire pairs (pins 1/2 and 3/6) (10/100Base-T)  PD-90xxG series carry DC power over 2-wire pairs (pins
4/5 and 7/8)