Thank you for choosing to purchase this micron security alarm controller. Micron product is manufactured to exacting quality standards. We understand the importance of designing products that are reliable and easy to use. You can rest secure knowing we have thought of everything to ensure your complete peace of mind.
The ‘Status’ Lamp.........................................................................................................................................................3
The ‘Mains’ Lamp.........................................................................................................................................................3
The ‘Armed’ Lamp........................................................................................................................................................3
Two Key Panic..............................................................................................................................................................4
Medical Alert.................................................................................................................................................................4
Fire Alert.......................................................................................................................................................................4
Adding, Changing or Deleting a User Code..................................................................................................................5
Arming the System........................................................................................................................................................5
To Arm the System and Exclude a Zone(s)..................................................................................................................6
Arming ..........................................................................................................................................................................8
Answer Phone Defeat....................................................................................................................................................9
Setting the Real Time Clock Time..............................................................................................................................10
Setting the Auto Arming Time....................................................................................................................................11
Follow Me Mode.........................................................................................................................................................11
Using the Scorpion Z4120C, Z6020C and Z8020C alarm controllers
2
The Keypad
The Scorpion Z4120C, Z6020C and Z8020C communicate system status through the keypad beeper. During an arming cycle the beeper will sound for the entire exit time. This is a ‘leave now’ warning. Scorpion will arm at the expiry of this period. On entry, the beeper sounds for the programmed entry period. If a valid user code is entered to disarm the system, the beeper emits two short tones. An incorrect entry is signalled by one long tone.
The ‘Status’ Lamp
The yellow status lamp is used to indicate several conditions.
Yellow lamp on: the system is armed or arming Yellow lamp off: the system is disarmed Yellow lamp flashing: an alarm has occurred, a system fault exists or
the panic function has been activated
The ‘Mains’ Lamp
The ‘Mains’ lamp is on when mains power is applied. In the event of a mains failure the ‘Mains’ light flashes until mains power is restored, and an arm/disarm cycle is completed. The ‘Mains’ lamp also flashes to indicate a low battery condition. When the battery is restored to full charge and an arm/disarm cycle is completed, the ‘Mains’ lamp stops flashing.
The ‘Armed’ Lamp
The ‘Armed’ lamp illuminates when the system is armed. The ‘Armed’ lamp also flashes to indicate when an alarm condition has occurred.
3
#
+
13+
Two Key Panic
If this function has been programmed in Scorpion by your installer it may be activated by pressing the keypad * and # keys simultaneously. All internal and external alarms will activate. A panic activation may be cancelled by entering any valid user code then #.
In panic situations press
Medical Alert
If this function has been programmed in Scorpion by your installer it may be activated by pressing keys 4 and 6 simultaneously on the keypad. A medical activation may be cancelled by entering any valid user code then #.
For medical alert press
Fire Alert
If this function has been programmed in Scorpion by your installer it may be activated by pressing keys 1 and 3 simultaneously on the keypad. A fire activation may be cancelled by entering any valid user code then #.
For fire alert press
User Codes
Scorpion controllers are capable of storing up to twenty-four user codes. Each user code may be two to four digits in length. User code 1 is factory set as a master user code 1234 and should be changed to your own selection. This user code can also be used to program the remaining user codes. Your installer will need to assign the functions of each additional user code when your system is installed. For example you may require user code 18 to be used by a domestic helper to arm but not disarm the system. This restriction on code 18 will need to be pre-set by
4
6
4
+
1 #
1
1
2 3
4
then 13+
then
1
9
1
2
then
#
the installer. The code may be entered at a later time using the master code. Use the user code attributes table in the rear of this user manual to record the functions for each code.
User code 15 is reserved as a ‘disarm all areas’ code for a partitioned Z8020C system and as a night-lock code for a Z4120C and Z6020C system. If the Z4120C and Z6020C are armed with user code 15, only this user code can disarm the system.
Adding, Changing or Deleting a User Code
Enter a valid master user code, press keys 1+3 together then enter a new user code then enter # then the user identifier (1 to 15). Repeat the procedure for adding other new user codes. To delete user codes, follow the same procedure, but omit the ‘new user code’ step. Finish by entering a #.
Example. To change the master user code from 1234 to 1912 press the following sequence:
Arming the System
Using Quickarm
If your installer has programmed the quickarm option you can arm the system by entering 1 then #. For partitioned systems (Z8020C only) entering 1 # will arm Area A and entering 2 # will arm Area B.
Quick arming Scorpion
Using a User Code
Enter a valid two, three or four digit user code then #.
5
2 3
4
1 #
then
2 3
4
1 #
then
2 3
4
1
then then
4
5
then
#
If all zones are clear, the keypad sounds a repeating sequence of three short beeps for the duration of the exit delay and the yellow status lamp turns on. The zone lamps for all zones that are arming are also turned on. At the end of the exit delay the zone lamps extinguish and the system is now armed.
If a zone fault or potential alarm condition exists and the user attempts to arm the system, the lamp(s) for those zone(s) flash and are accompanied by a repeating sequence of two long beeps. This indicates that one or more of the zones are faulty or not secured. The panel should be disarmed, the problem located (possible open door or window) and the system re-armed.
To Arm the System and Exclude a Zone(s)
Enter a valid user code then * (all zone led’s light) followed by the zone number(s) to be excluded (those zone led’s turn off), then press #.
Example: to arm the system with zones 4 and 5 excluded press:
Disarming
the System
Follow the same sequence as for arming, enter a valid two, three or four digit user code then #. To send a duress signal to a monitoring station while disarming, hold the # key down until a second beep is heard.
The keypad will beep twice and the yellow status light will turn off. A flashing yellow status lamp indicates that one or more zones have been alarmed. The zone lamps