Micron MTFDDAK120MAV, MTFDDAK240MAV, MTFDDAK480MAV, MTFDDAK960MAV User Manual

M500 2.5-Inch NAND Flash SSD

M500 2.5-Inch SATA NAND Flash SSD

MTFDDAK120MAV, MTFDDAK240MAV, MTFDDAK480MAV, MTFDDAK960MAV

Features

Features
• Micron® 20nm MLC NAND Flash
• RoHS-compliant package
• TCG/Opal 2.0-compliant self-encrypting drive (SED)
• Hardware-based AES-256 encryption engine
• ATA modes supported – PIO mode 3, 4 – Multiword DMA mode 0, 1, 2 – Ultra DMA mode 0, 1, 2, 3, 4, 5
• Industry-standard, 512-byte sector size support
• Hot-plug/hot-remove capable
• Power loss protection for data-at-rest
• Device Sleep (DEVSLP), extreme low-power mode
• Native command queuing support with 32-com­mand slot support
• ATA-8 ACS2 command set compliant
• ATA security feature command set and password login support
• Secure erase (data page) command set: fast and se­cure erase
• Sanitize device feature set support
• Self-monitoring, analysis, and reporting technology (SMART) command set
• Windows 8 drive telemetry
• Adaptive thermal monitoring
• Power loss protection for data-at-rest
• Performance – PCMark® Vantage (HDD test suite score): Up to
80,000 – Sequential 128KB READ: Up to 500 MB/s – Sequential 128KB WRITE: Up to 400 MB/s – Random 4KB READ: Up to 80,000 IOPS – Random 4KB WRITE: Up to 80,000 IOPS – READ/WRITE latency: 5ms/25ms (MAX)
1, 2
• Reliability – MTTF: 1.2 million device hours
3
– Static and dynamic wear leveling – Uncorrectable bit error rate (UBER): <1 sector
per 1015 bits read
• Low power consumption – 150mW TYP
4
• Endurance: Total bytes written (TBW) – Up to
5
500TB
• Capacity6 (unformatted): 120GB, 240GB, 480GB, 960GB
• Mechanical – SATA connector: 5V ±10% – 2.5-inch drive: 100.45mm x 69.85mm x 7.0mm – Weight: 70g (MAX)
• Secure firmware update with digitally signed firm­ware image
• Operating temperature – Commercial (0°C to +70°C)
Notes:
1. Typical I/O performance numbers as meas­ured fresh-out-of-the-box (FOB) using Iome­ter with a queue depth of 32 and write cache enabled.
2. 4KB transfers used for READ/WRITE latency values.
3. The product achieves a mean time to failure (MTTF) based on population statistics not relevant to individual units.
4. Active average power measured during exe­cution of MobileMark® with DIPM (device­initiated power management) enabled.
5. Endurance may depend highly on the na­ture of the data stream from the host com­puter. See Endurance section for more de­tails.
6. 1GB = 1 billion bytes; formatted capacity is less.
7. Drive onboard temperature sensor.
7
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
Products and specifications discussed herein are subject to change by Micron without notice.
Warranty: Contact your Micron sales representative for further information regarding the product, including product warranties.
1
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
MT FD D AV 120 M AZ - 1 AE 1 ES
Micron Technology
Product Family
FD = Flash drive
Drive Interface
D = SATA 6.0 Gb/s
Drive Form Factor
AK = 2.5-inch (7mm) AT = mSATA AV = M.2 (80mm x 22mm 3.5mm)
Drive Density
064 = 64GB 120 = 120GB 128 = 128GB 240 = 240GB 256 = 256GB 480 = 480GB 512 = 512GB 960 = 960GB 1T0 = 1024GB
NAND Flash Type
M = MLC
Product Family
AV = M500 AY = M550 AZ = M510
Production Status
Blank = Production ES = Engineering sample MS = Mechanical sample
Customer Designator
YY = Standard HA = HP (Client)
Feature Set
AA = Contact factory AB = Standard AC = Contact factory ZZ = Blank Z = Blank
Extended Feature Set
1 = Contact factory 2 = SED (self-encrypting drive)
Sector Size
1 = 512 byte
NAND Flash Component
AE = 128Gb, MLC, x8, 3.3V (20nm) AH = 64Gb, MLC, x8, 3.3V (20nm)
BOM Revision
For example: 1 = 1st generation 2 = 2nd generation
2 AB HA
M500 2.5-Inch NAND Flash SSD
Features

Part Numbering Information

Micron’s M500 SSD is available in different configurations and densities. The chart below is a comprehensive list of options for the M500 series devices; not all options listed can be combined to define an offered product. Visit
www.micron.com for a list of valid part numbers.
Figure 1: Part Number Chart
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
2
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.

General Description

Micron’s solid state drive (SSD) uses a single-chip controller with a SATA interface on the system side and 8-channels of Micron NAND Flash internally. Packaged in an HDD replacement enclosure, the SSD integrates easily in existing storage infrastructures.
The SSD is designed to use the SATA interface efficiently during both READs and WRITEs while delivering bandwidth-focused performance. SSD technology enables en­hanced boot times, faster application load times, reduced power consumption, and ex­tended reliability.
The self-encypting drive (SED) features a FIPS-compliant, AES-256 encryption engine, providing hardware-based, secure data encryption, with no loss of SSD performance. This SED follows the TCG/Opal specification for trusted peripherals.
When TCG/Opal features are not enabled, the device can perform alternate data en­cryption by invoking the ATA security command-set encryption features, to provide full­disk encryption (FDE) managed in the host system BIOS. TCG/Opal and FDE feature sets cannot be enabled simultaneously.
The data encryption is always running; however, encryption keys are not managed and the data is not secure until either TCG/Opal or FDE feature sets are enabled.
M500 2.5-Inch NAND Flash SSD
General Description
Figure 2: Functional Block Diagram
SATA
SSD
controller
DRAM buffer
NAND
NAND
NAND
NAND
NAND
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
3
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD

Logical Block Address Configuration

Logical Block Address Configuration
The drive is set to report the number of logical block addresses (LBA) that will ensure sufficient storage space for the specified capacity. Standard LBA settings, based on the IDEMA standard (LBA1-02), are shown below.
Table 1: Standard LBA Settings
User Available
Total LBA Max LBA
Capacity
120GB 234,441,648 DF94BB0 234,441,647 DF94BAF 120,034,123,776
240GB 468,862,128 1BF244B0 468,862,127 1BF244AF 240,057,409,536
480GB 937,703,088 37E436B0 937,703,087 37E436AF 480,103,981,056
960GB 1,875,385,008 6FC81AB0 1,875,385,007 6FC81AAF 960,197,124,096
Decimal Hexadecimal Decimal Hexadecimal (Unformatted)
Bytes

Physical Configuration

Table 2: 2.5-Inch Dimensions and Weight
Value
Specification
Height 7.00 mm
Width 69.85 mm
Length 100.45 mm
Unit weight 70 g
Insertion rating (cabled) 50 insert/remove cycles
Insertion rating (backplane) 500 insert/remove cycles
UnitNom Max
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
4
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.

Interface Connectors

Power
segment
Signal segment
P1
S1
The SATA signal segment interface cable has four conductors and three ground connec­tions. As shown in Package Dimensions, the cable includes a 7-pin signal segment and a 15-pin power segment arranged in a single row with a 1.27mm (0.050in) pitch.
Figure 3: SSD Interface Connections
Table 3: SATA Signal Segment Pin Assignments
Signal Name Type Description
S1 GND Ground
S2 A
S3 A#
S4 GND Ground
S5 B#
S6 B
S7 GND Ground
M500 2.5-Inch NAND Flash SSD
Interface Connectors
Differential signal pair A and A#
Differential signal pair B and B#
Table 4: 2.5-Inch SATA Power Segment Pin Assignments
Pin# Signal Name Description
P1 RETIRED No connect
P2 RETIRED No connect
P3 DEVSLP Device sleep
P4 GND Ground
P5 GND Ground
P6 GND Ground
P7 V5 5V power, precharge
P8 V5 5V power
P9 V5 5V power
P10 GND Ground
P11 DAS Device activity signal
P12 GND Ground
P13 V12 No connect
P14 V12 No connect
P15 V12 No connect
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
5
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD

Performance

Performance
Measured performance can vary for a number of reasons. The major factors affecting drive performance are the capacity of the drive and the interface of the host. Addition­ally, overall system performance can affect the measured drive performance. When comparing drives, it is recommended that all system variables are the same, and only the drive being tested varies.
Performance numbers will vary depending on the host system configuration.
For SSDs designed for the client computing market, Micron specifies performance in FOB ("fresh-out-of-box") state. Data throughput measured in "steady state" may be lower than FOB state, depending on the nature of the data workload.
For a description of these performance states and of Micron's best practices for per­formance measurement, refer to micron.com/ssd.
Table 5: Drive Performance
Capacity 120GB 240GB 480GB 960GB
UnitInterface Speed 6 Gb/s 6 Gb/s 6 Gb/s 6 Gb/s
PCMark Vantage 70,000 80,000 80,000 80,000 HDD score
Sequential read (128KB transfer) 500 500 500 500 MB/s
Sequential write (128KB transfer) 130 250 400 400 MB/s
Random read (4KB transfer) 62,000 72,000 80,000 80,000 IOPS
Random write (4KB transfer) 35,000 60,000 80,000 80,000 IOPS
READ latency (MAX) 5 5 5 5 ms
WRITE latency (MAX) 25 25 25 25 ms
READ latency (TYP) 160 160 160 160 µs
WRITE latency (TYP) 40 40 40 40 µs
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
Notes:
1. Performance numbers are maximum values, except as noted.
2. Typical I/O performance numbers as measured using Iometer with a queue depth of 32 and write cache enabled. Fresh-out-of-box (FOB) state is assumed. For performance measurement purposes, the SSD may be restored to FOB state using the secure erase command.
3. Iometer measurements are performed on an 20GB span of logical block addresses (LBAs).
4. 4KB transfers are used to measure READ/WRITE latency values with write cache enabled.
5. System variations will affect measured results. For comparison, PCMark scores are meas­ured with the SSD as a secondary drive in a two-drive system. When measured as an OS drive, system overhead can cause lower scores.
For a description of these performance states and of Micron's best practices for per­formance measurement, refer to Micron's technical marketing brief "Best Practices for SSD Performance Measurement"
6
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.

Reliability

Micron’s SSDs incorporate advanced technology for defect and error management. They use various combinations of hardware-based error correction algorithms and firmware-based static and dynamic wear-leveling algorithms.
Over the life of the SSD, uncorrectable errors may occur. An uncorrectable error is de­fined as data that is reported as successfully programmed to the SSD but when it is read out of the SSD, the data differs from what was programmed.
Table 6: Uncorrectable Bit Error Rate
Uncorrectable Bit Error Rate Operation
<1 sector per 1015 bits read READ

Mean Time To Failure

Mean time to failure (MTTF) for the SSD can be predicted based on the component reli­ability data using the methods referenced in the Telcordia SR-332 reliability prediction procedures for electronic equipment.
Table 7: MTTF
M500 2.5-Inch NAND Flash SSD
Reliability
Capacity MTTF (Operating Hours)
120GB 1.2 million
240GB 1.2 million
480GB 1.2 million
960GB 1.2 million
Note:
1. The product achieves a mean time to failure (MTTF) of 1.2 million hours, based on popu­lation statistics not relevant to individual units.
1
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
7
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.

Endurance

M500 2.5-Inch NAND Flash SSD
Reliability
Endurance for the SSD can be predicted based on the usage conditions applied to the device, the internal NAND component cycles, the write amplification factor, and the wear-leveling efficiency of the drive. The tables below show the drive lifetime for each SSD capacity by client computing and sequential input and based on predefined usage conditions.
Table 8: Drive Lifetime – Client Computing
Capacity Drive Lifetime (Total Bytes Written)
120GB 72TB
240GB 72TB
480GB 72TB
960GB 72TB
Notes:
1. Total bytes written calculated with the drive 90% full.
2. SSD volatile write cache is enabled.
3. Access patterns used during reliability testing are 25% sequential and 75% random and consist of the following: 50% are 4KiB; 40% are 64KiB; and 10% are 128KiB.
4. Host workload parameters, including write cache settings, IO alignment, transfer sizes, randomness, and percent full, that are substantially different than the described notes, may result in varied endurance results.
5. GB/day can be calculated by dividing the total bytes written value by (365 × number of years). For example: 72TB/5 years/365 days = 40 GB/day for 5 years.
Table 9: Drive Lifetime – Sequential Input
Capacity Drive Lifetime (Total Bytes Written)
120GB 125TB
240GB 250TB
480GB 500TB
960GB 500TB
Notes:
1. Endurance of Client SSDs in some data center applications can be maximized by imple­menting workloads which are sequential when writing, with read-intensive access. Mi­cron recommends no higher than 20% of input/output operations be writes.
2. SSD volatile write cache is enabled.
3. Micron recommends sequential writes in transfer sizes of 128KiB or integer multiples of 128KiB which are 4KiB-aligned. Contact Micron for details.
4. Host workload parameters, including write cache settings, IO alignment, transfer sizes, randomness, and percent full, that are substantially different than the described notes, may result in varied endurance results.
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
8
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.

Electrical Characteristics

Environmental conditions beyond those listed may cause permanent damage to the de­vice. This is a stress rating only, and functional operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability.
Table 10: SATA Power Consumption
M500 2.5-Inch NAND Flash SSD
Electrical Characteristics
Device Sleep
Capacity
120GB <5 80 150 2100 mW
240GB <5 95 150 3200 mW
480GB <10 100 150 3600 mW
960GB <20 100 150 3800 mW
Average Idle Average Active Average
Notes:
1. Data taken at 25°C using a 6 Gb/s SATA interface.
2. Active average power measured while running MobileMark Productivity Suite.
3. DIPM (device-initiated power management) enabled. DIPM Slumber supported.
4. Active maximum power is measured using Iometer with 128KB sequential write trans­fers.
Active Maximum
(128KB transfer) Unit
Table 11: Maximum Ratings
Parameter/Condition Symbol Min Max Unit
Voltage input V5 4.5 5.5 V
Operating temperature T
Non-operating temperature –40 85 °C
Rate of temperature change 20 °C/hour
Relative humidity (non-condensing) 5 95 %
Notes:
1. Temperature is best measured by reading the SSD's on-board temperature sensor, which is recorded in SMART attribute 194 (or 0xC2).
2. Power-off sequence: When the SSD is shut down, the ATA STANDBY IMMEDIATE (STBI) command should be the last command sent by the host and acknowledged by the SSD. Failure to follow this process might result in a longer than normal time-to-ready (TTR) during the subsequent power-on sequence. TTR is the time from power-on to drive ready to accept SATA commands.
S
0 70 °C
Table 12: Shock and Vibration
Parameter/Condition Specification
Non-operating shock 1500G/0.5ms
Non-operating vibration 5–800Hz @ 3.13G
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
9
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.

Adaptive Thermal Monitoring

The device features adaptive thermal monitoring. While most host computers exhibit operating environments that keep an SSD running in the range of 40°C to 45°C, adap­tive thermal monitoring enables the SSD device to operate in a wide variety of environ­ments by helping to prevent the host computer from running at excessive temperatures.
Adaptive thermal monitoring reduces NAND operations by approximately 40% when the SSD's internal measured temperature reaches 75°C. The SSD remains in this low­ered performance state until the temperature returns to 65°C; the SSD then returns to normal operating mode. These transition points might occur at points somewhat differ­ent from case or ambient temperature because of thermal effects that cause a difference between temperature sensed at the PCB level and temperature at the specified operat­ing environment.
Adaptive thermal monitoring does not change the current negotiated speed of the SATA bus, nor require or cause any new commands to be issued on the SATA bus. Rated­throughput performance is not guaranteed at any point above the maximum specified operating temperature.
The thermal monitoring feature can be disabled using ATA SET FEATURE commands as described below. The default setting is ENABLED.
Note: The SSD will return to the default setting after each power cycle or COMRESET command. Arrangements should be made to re-issue the DISABLE command after each power cycle or COMRESET.
M500 2.5-Inch NAND Flash SSD
Adaptive Thermal Monitoring

DISABLE THERMAL MONITORING Command

• Command set feature
• Sub-command enable SATA feature
• Specific feature hardware feature control
• LBA FFFFh
• IDFY word 78, bit 5 will be set to indicate SATA hardware feature control is active
Table 13: Disable Thermal Monitoring Command Set Register
Register
Feature Set
Feature 10h
Sector count 08h
Sector number FFh
Cylinder low FFh
Cylinder high xx
Drive head xx
Command EFh
7 6 5 4 3 2 1 0

ENABLE THERMAL MONITORING Command

• Command set feature
• Sub-command disable SATA feature
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
10
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
• Specific feature hardware feature Control
• LBA FFFFh
• IDFY word 78, bit 5 will be set to indicate SATA hardware feature control is inactive
Table 14: Enable Thermal Monitoring Command Set Register
Register
Feature Set
Feature 0x90h
Sector count 0x8h
Sector number 0xFFh
Cylinder low 0xFFh
Cylinder high xx
Drive head xx
Command 0xEFh
7 6 5 4 3 2 1 0
M500 2.5-Inch NAND Flash SSD
Adaptive Thermal Monitoring
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
11
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD

TCG/Opal Support

TCG/Opal Support
Table 15: TCG/Opal Support Parameters
Property Supported? Comments
TCG Storage Specifications
OPAL: TCG Storage Security SubSystem Class
TCG Core Specification Specification 2.00 Revision 2.00, Nov 4, 2011
TCG Storage Interface Interactions Specifi­cation
OPAL SSC 1.00 (backward compatibility) Not supported
OPAL SSC Additional Feature Set Specification
Additional DataStore Table Supported Specification 1.00 Revision 1.00, Feb 24, 2012
Single User Mode Supported Specification 1.00 Revision 1.00, Feb 24, 2012
TCG Storage Protection Mechanisms for Secrets
PSID – Physical Presence SID Supported Specification Version 1.00 Committee Draft Revi-
GUDID (Globally Unique Serial Number) Supported Mandatory GUDID Proposal 11/03/2011 (Microsoft)
SID Authority Disable Supported SID Authority Disable Proposal 9/26/2011 (Micro-
Modifiable CommonName Columns Supported Modifiable CommonName Columns Proposal
OPAL SSC Feature Set – Specific List
ALL OPAL Mandatory Features Supported
Close Session (optional) Supported Allows Tper to notify the host it has aborted a ses-
Restricted Command & Table (optional) Not Supported The interface control template enables TPer control
Type Table (not required) Not Supported
Activate Method Supported
Revert Method Supported
Revert SP Method Supported
Activate Method Within Transactions Not Supported As per OPAL, this behavior is out of the scope
Revert Method within Transactions Not Supported As per OPAL, this behavior is out of the scope
Revert SP Method within Transactions Not Supported As per OPAL, this behavior is out of the scope
Creation/Deletion of Tables/Rows after Manufacturing
Tper Feature
COM ID Management Support Not Supported Dynamic COM ID allocation & management not
Buffer Management Support Not Supported Flow control
Specification 2.00 Revision 1.00, Feb 24, 2012
TCG Reference
Specification
Specification Version 1.02 Revision 1.00 30 Decem­ber, 2011
Supported Specification Version 1.00 Revision 1.07 17 August,
2011
sion 1.05 February 9, 2011
soft)
7/22/2010 (Microsoft)
sion
over selected interface commands; the benefit is the reduction of undesired side effects
Not Supported As per OPAL, this behavior is out of the scope
supported
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
12
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD
TCG/Opal Support
Table 15: TCG/Opal Support Parameters (Continued)
Property Supported? Comments
ACK/NACK Support Not Supported Session reliability
Async Support Not Supported Asynchronous protocol support with multiple com-
mands per session
Geometry Reporting Feature
ALIGN Supported OPAL 2.0 (only)
Logical Block Size 512 bytes Logical block size = 512 Bytes
Alignment Granularity 4096 Bytes Page or Descriptor size <<Minimum AES LU size>>
Lowest Aligned LBA 0
OPAL SSC V2.00 Feature Descriptor
Base COM ID 0x1000 0x1000-0xFFFF defined for COM ID management
Number of COM IDs 1
Range Crossing Behavior 0 If drive receives a READ or WRITE command that
spans multiple LBA ranges and the LBA ranges are not locked, then:
1. Process the data transfer, if Range Crossing = 0
2. Terminate the command with “Other Invalid Command Parameter” if Range Crossing = 1
Number of Locking SP Admin Authorities Supported
Number of Locking SP User Authorities Supported
Initial C_PIN_SID PIN Indicator 0x00 0x00 = The initial C_PIN_SID PIN value is equal to
Behavior of C_PIN_SID PIN upon Ter Revert 0x00 0x00 = The C_PIN_SID PIN value becomes the value
DataStore Table Feature
Maximum number of DataStore Tables 9 The maximum number of the DataStore tables that
Maximum total size of DataStore Tables 90MB Specifies the maximum total size in bytes of all of
DataStore Table Size Alignment 10MB
4 As per OPAL 2.0, drive should support at least 4 ad-
min
9 As per OPAL 2.0, drive should support at least 8
users
the C_PIN_MSID PIN value 0xFF = The initial C_PIN_SID PIN value is VU, and MAY not be equal to the C_PIN_MSID PIN value OPAL 2.0 (only) Customer-specific SID – Configurable
of the C_PIN_MSID PIN column after successful in­vocation of revert on the admin SP’s object in the SP table 0xFF = The C_PIN_SID PIN value changes to a VU value after successful invocation of revert on the admin SP’s object in the SP table and MAY not be equal to the C_PIN_MSID PIN value OPAL 2.0 (only)
the TPer supports, including the DataStore table defined in OPAL SSC 2.0
the DataStore tables that TPer supports, including the DataStore table defined in OPAL SSC 2.0
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
13
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD
TCG/Opal Support
Table 15: TCG/Opal Support Parameters (Continued)
Property Supported? Comments
MBR Table 128MB
Byte Table Access Granularity
Mandatory Write Granularity 1 TPer enforces when the host invokes the set meth-
od on byte tables; it should be less than or equal to 8192; it should be less than or equal to Recommen­ded Access Granularity, OPAL 2.0 (only)
Recommended Access Granularity 8192 Tper recommends when the host invokes the set or
get method on byte tables; it should be less than or equal to 8192
Cryptographic Features
AES Key Size 256 Bits AES key is generated by using CTR DRBG algorithm
(FIPS Compliant)
AES Mode CBC IV swapped
Number of Ranges/Band Supported 9
(8 user definable,
1 global range)
Re-Encryption Not Supported
Key Management Authentication data required. Conforms to TCG
Crypto Erase Completion Time <1s Yes
Cryptographic Algorithms are Certified by
Pending
FIPS-197
AES 256-Bit CBC/ECB Mode Supported ECB mode used only for generating the random
CTR DRBG Supported
SHA 256 Supported
RSA 2048 Signature Verification Supported
TPer Communication Properties
Max ComPacket Size 131072 256 sectors (128K)
Max Response ComPacket Size 131072 256 sectors (128K)
Max Packet Size 128512
Max Individual Token Size 123904
Max Packets 1
Max SubPackets 1
Max Sessions 1 Each session requires a set of buffers and variables
Max Transaction Limit 1 Transaction are inside sessions
Max Methods 1 Methods are contained in a transaction
Max Authentications 2
Now supporting 8 LBA ranges; range cross read and write allowed if LBA ranges are unlocked
Storage Protection Mechanisms for Secrets; Specifi­cation version 1.00, Revision 1.00, 05 March 2012
key by CTR DRBG
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
14
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD
TCG/Opal Support
Table 15: TCG/Opal Support Parameters (Continued)
Property Supported? Comments
Def Session Timeout Yes The session timeout length (in milliseconds) used
by the TPer by default
IEEE1667
Probe Silo Supported
TCG Storage Silo Supported
Other than Probe and TCG Storage Silo Not Supported
IEEE1667 Major Version TBD As per current draft specification, major and minor
versions are not yet decided
IEEE1667 Minor Version TBD
Maximum P_OUT Transfer Size 131072 256 sectors (128K)
Others
FDE (ATA Security with Key Management) Yes
Secure Firmware Download Supported Firmware image is validated by using SHA256 and
RSA2048 algorithm (FIPS-compliant; certification pending)
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
15
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD

Device ID

Table 16: Identify Device
See Note 1 for setting definitions
Word Bit(s) Setting Default Value Description
0 General configuration bit-significant information
15 F 0b 0 = ATA device
14–8 X 0000100b Retired
7 F 0b 1 = Removable media device
6 F 1b 1 = Fixed disk HDD
5–3 X 000b Retired
2 V 0b Response incomplete
1 X 0b Retired
0 F 0b Reserved
1 3FFFh Obsolete
2 F C837h Specific configuration
3 F 0010h Obsolete
4 F 0000h 0000h Retired
6 F 003Fh Obsolete
7 (O)V 0000h 0000h
9 ( )X 0000h Retired
10 (M)F varies Serial number (20 ASCII characters)
20 ( )X 0000h 0000h
0000h
23 (M)F varies Firmware revision (8 ASCII characters)
27 (M)F varies Model number (40 ASCII characters)
47 15–8 F 80h 80h
7–0 F 10h 00h = Reserved
48 Trusted Computing feature set options
15 F 0b Shall be cleared to zero
14 F 1b Shall be set to one
13–1 F 0000000000000b Reserved for the Trusted Computing Group
0 F 1b 1=Trusted Computing feature set is support
Reserved for assignment by the CompactFlash Association
Retired/Obsolete
01h-FFh = Maximum number of logical sectors that shall be transferred per DRQ data block on READ/WRITE MULTIPLE commands
Device ID
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
16
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD
Table 16: Identify Device (Continued)
See Note 1 for setting definitions
Word Bit(s) Setting Default Value Description
49 Capabilities
15–14 F 00b Reserved for the IDENTIFY PACKET DEVICE command.
13 F 1b 1 = Standby timer values as specified in this standard are
supported
0 = Standby timer values shall be managed by the device
12 F 0b Reserved for the IDENTIFY PACKET DEVICE command.
11 F 1b 1= IORDY supported
0 = IORDY may be supported
10 F 1b 1 = IORDY may be disabled
9 1b 1 = LBA supported
8 F 1b 1 = DMA supported.
7–0 F 00000000b Retired
50 Capabilities
15 F 0b Shall be cleared to zero
14 F 1b Shall be set to one
13–2 F 000000000000b Reserved
1 X 0b Obsolete
0 F 1b Shall be set to one to indicate a vendor specific standby tim-
er value minimum.
51 ( )X 0000h 0000h Obsolete
53 15–3 F 0000000000000b Reserved
2 F 1b 1 = The fields reported in word 88 are valid
0 = the fields reported in word 88 are not valid
1 F 1b 1 = The fields reported in words (70:64) are valid
0 = the fields reported in words (70:64) are not valid
0 X 1b Obsolete
54 ()X 3FFFh 0010h
003Fh FC10h
00FBh
59 15 F 1b 1 = The BLOCK ERASE EXT command is supported
14 F 1b 1 = The OVERWRITE EXT command is supported
13 F 0b 1 = The CRYPTO SCRAMBLE EXT command is supported
12 F 1b 1 = The Sanitize feature set is supported
11–9 F 000b Reserved
8 V 1b 1 = Multiple sector setting is valid
7–0 V 00010000b xxh = Current setting for number of logical sectors that shall
60–61 M(F) Varies by capacity Total number of user addressable logical sectors
Obsolete
be transferred per DRQ data block on READ/WRITE MULTI­PLE commands
Device ID
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
17
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD
Device ID
Table 16: Identify Device (Continued)
See Note 1 for setting definitions
Word Bit(s) Setting Default Value Description
62 ()X 0000h Obsolete
63 15–11 F 00000b Reserved
10 V 0b 1 = Multiword DMA mode 2 is selected
0 = Multiword DMA mode 2 is not selected
9 V 0b 1 = Multiword DMA mode 1 is selected
0 = Multiword DMA mode 1 is not selected
8 V 0b 1 = Multiword DMA mode 0 is selected
0 = Multiword DMA mode 0 is not selected
7–3 F 0000b Reserved
2 F 1b 1 = Multiword DMA mode 2 and below are supported
1 F 1b 1 = Multiword DMA mode 1 and below are supported
0 F 1b 1 = Multiword DMA mode 0 is supported
64 15–8 F 0 Reserved
7–0 F 00000011b PIO modes supported
65 F 0078h Minimum Multiword DMA transfer cycle time per word
Cycle time in nanoseconds
66 F 0078h Manufacturer's recommended Multiword DMA transfer cy-
cle time Cycle time in nanoseconds
67 F 0078h Minimum PIO transfer cycle time without flow control
Cycle time in nanoseconds
68 F 0078h Minimum PIO transfer cycle time with IORDY flow control
Cycle time in nanoseconds
69 F Additional Supported
15 F 0b 1 = CFast Specification Support
14 F 1b 1 = Deterministic read after Trim is supported
13 F 0b 1 = Long Physical Sector Alignment Error Reporting Control
is supported
12 F 0b 1 = DEVICE CONFIGURATION IDENTIFY DMA and DEVICE
CONFIGURATION SET DMA are supported
11 F 0b 1 = READ BUFFER DMA is supported
10 F 0b 1 = WRITE BUFFER DMA is supported
9 F 0b 1 = SET MAX PASSWORD DMA and SET MAX UNLOCK DMA
are supported
8 F 0b 1 = DOWNLOAD MICROCODE DMA is supported
7 F 1b Reserved for IEEE-1667
6 F 0b 1 = Optional ATA device 28-bit commands supported
5 F 1b 1 = Read zero after Trim is supported
4 F 1b 1 = Device encrypts all user data
3–0 F 0000b Reserved
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
18
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD
Table 16: Identify Device (Continued)
See Note 1 for setting definitions
Word Bit(s) Setting Default Value Description
70 F 0000h Reserved
71 F 0000h 0000h
0000h 0000h
75 Queue depth
15–5 F 00000000000b Reserved
4–0 F 11111b Maximum queue depth - 1
76 Serial ATA capabilities
15 F 0b 1 = Supports READ LOG DMA EXT as equivalent to READ
14 F 1b 1 = Supports device automatic partial to slumber transitions
13 F 1b 1 = Supports host automatic partial to slumber transitions
12 F 1b Supports Native Command Queuing priority information
11 F 0b Supports Unload while NCQ commands outstanding
10 F 1b Supports Phy event counters
9 F 1b Supports receipt of host initiated interface power manage-
8 F 1b Supports native Command Queueing
7–4 F 0000b Reserved for future Serial ATA signaling speed grades
3 F 1b 1 = Supports Serial ATA Gen-3 speed (6.0 Gb/s)
2 F 1b 1 = Supports Serial ATA Gen-2 speed (3.0 Gb/s)
1 F 1b 1 = Supports Serial ATA Gen-1 speed (1.5 Gb/s)
0 F 0b Reserved (set to 0)
77 Serial ATA additional capabilities
15–8 F 00000000b Reserved for future Serial ATA definition
7 F 1b 1 = Supports DEVSLP_to_ReducedPwrState
6 F 0b Reserved
5 F 0b Supports NCQ Queue Management Command
4 F 0b Supports NCQ Streaming
3–1 V 010b Coded value indicating current negotiated Serial ATA signal
0 F 0b Shall be cleared to zero
Reserved for the IDENTIFY PACKET DEVICE command
LOG EXT
ment requests
speed
Device ID
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
19
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD
Table 16: Identify Device (Continued)
See Note 1 for setting definitions
Word Bit(s) Setting Default Value Description
78 Serial ATA features supported
15–8 F 000000000b Reserved
7 F 1b 1 = Supports NCQ Autosense
6 F 1b 1 = Supports software settings preservation
5 F 0b Reserved
4 F 0b 1 = Supports in-order data delivery
3 F 1b 1 = Supports dev initiate interface power management
2 F 1b 1 = Supports DMA Setup Auto-Activate optimization
1 F 0b 1 = Supports non-zero buffer offsets in DMA Setup FIS
0 F 0b Reserved (set to 0)
79 Serial ATA features enabled
15–7 V 000000000b Reserved
6 V 1b 1 = Software settings preservation enabled
5 V 0b 1 = Asynchronous notification enabled
4 V 0b 1 = In-order data delivery enabled
3 V 0b 1 = Device initiating interface power management enabled
2 V 0b 1 = DMA Setup Auto-Activate optimization enabled
1 V 0b 1 = Non-zero buffer offsets in DMA Setup FIS enabled
0 V 0b Reserved (set to 0)
80 Major revision number
15–10 F 000000b Reserved
9 F 1b 1 = Supports ATA8-ACS2
8 F 1b 1 = Supports ATA8-ACS
7 F 1b 1 = Supports ATA/ATAPI-7
6 F 1b 1 = Supports ATA/ATAPI-6
5 F 1b 1 = Supports ATA/ATAPI-5
4 F 1b 1 = Supports ATA/ATAPI-4
3 F 1b Obsolete
2 S 0b Obsolete
1 S 0b Obsolete
0 F 0b Reserved
81 F 0028h Minor revision number
0028h = ATA8-ACS version 6
Device ID
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
20
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
Table 16: Identify Device (Continued)
See Note 1 for setting definitions
Word Bit(s) Setting Default Value Description
82 Command set supported
15 X 0b Obsolete
14 F 1b 1 = NOP command supported
13 F 1b 1 = READ BUFFER command supported
12 F 1b 1 = WRITE BUFFER command supported
11 X 0b Obsolete
10 F 1b 1 = Host Protected Area feature set supported
9 F 0b 1 = DEVICE RESET command supported
8 F 0b 1 = SERVICE interrupt supported
7 F 0b 1 = Release interrupt supported
6 F 1b 1 = Read look-ahead supported
5 F 1b 1 = Write cache supported
4 F 0b Shall be cleared to zero to indicate that the PACKET feature
set is not supported.
3 F 1b 1 = Mandatory Power Management feature set supported
2 F 0b Obsolete
1 F 1b 1 = Security feature set supported
0 F 1b 1 = SMART feature set supported
83 Command set supported
15 F 0b Shall be cleared to zero
14 F 1b Shall be set to one
13 F 1b 1 = FLUSH CACHE EXT command supported
12 F 1b 1 = Mandatory FLUSH CACHE command supported
11 F 1b 1 = Device Configuration Overlay feature set supported
10 F 1b 1 = 48-bit address feature set supported
9 F 0b 1 = Automatic Acoustic Management feature set supported
8 F 1b 1 = SET MAX security extension supported
7 F 0b See Address Offset Reserved Area Boot INCITS TR27:2001
6 F 0b 1 = SET FEATURES subcommand required to spin-up after
power-up
5 F 0b 1 = Power-Up In Standby feature set supported
4 F 0b Obsolete
3 F 1b 1 = Advanced Power Management feature set supported
2 F 0b 1 = CFA feature set supported
1 F 0b 1 = READ/WRITE DMA QUEUED supported
0 F 1b 1 = DOWNLOAD MICROCODE command supported
M500 2.5-Inch NAND Flash SSD
Device ID
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
21
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD
Table 16: Identify Device (Continued)
See Note 1 for setting definitions
Word Bit(s) Setting Default Value Description
84 Command set/feature supported extension
15 F 0b Shall be cleared to zero
14 F 1b Shall be set to one
13 F 1b 1 = IDLE IMMEDIATE with UNLOAD FEATURE supported
12 F 0b Reserved for technical report INCITS TR-37-2004 (TLC)
11 F 0b Reserved for technical report INCITS TR-37-2004 (TLC)
10–9 F 00b Obsolete
8 F 1b 1 = 64-bit word wide name supported
7 F 0b 1 = WRITE DMA QUEUED FUA EXT command supported
6 F 1b 1 = WRITE DMA FUA EXT and WRITE MULTIPLE FUA EXT
commands supported
5 F 1b 1 = General Purpose Logging feature set supported
4 F 0b 1 = Streaming feature set supported
3 F 0b 1 = Media Card Pass Through Command feature set suppor-
ted
2 F 0b 1 = Media serial number supported
1 F 1b 1 = SMART self-test supported
0 F 1b 1 = SMART error logging supported
85 Command set/feature enabled.
15 X 0b Obsolete
14 F 1b 1 = NOP command supported
13 F 1b 1 = READ BUFFER command supported
12 F 1b 1 = WRITE BUFFER command supported
11 X 0b Obsolete
10 V 1b 1 = Host Protected Area feature set enabled
9 F 0b 1 = DEVICE RESET command supported
8 V 0b 1 = SERVICE interrupt enabled
7 V 0b 1 = Release interrupt enabled
6 V 1b 1 = Look-ahead enabled
5 V 1b 1 = Write cache enabled
4 F 0b Shall be cleared to zero to indicate that the PACKET feature
set is not supported.
3 F 1b Power Management feature set is enabled
2 F 0b Obsolete
1 V 0b 1 = Security Mode feature set enabled
0 V 1b 1 = SMART feature set enabled
Device ID
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
22
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD
Table 16: Identify Device (Continued)
See Note 1 for setting definitions
Word Bit(s) Setting Default Value Description
86 Command set/feature enabled.
15 1b 1 = Words 120-119 are valid
14 F 0b 1 = Reserved
13 F 1b 1 = FLUSH CACHE EXT command supported
12 F 1b 1 = FLUSH CACHE command supported
11 F 1b 1 = Device Configuration Overlay supported
10 F 1b 1 = 48-bit Address features set supported
9 V 0b 1 = Automatic Acoustic Management feature set enabled
8 F 0b 1 = SET MAX security enabled by SET MAX SET PASSWORD
7 F 0b Reserved for address Offset Reserved Area Boot, INCITS
TR27:2001
6 F 0b 1 = SET FEATURES subcommand required to spin-up after
power-up
5 V 0b 1 = Power-Up In Standby feature set enabled
4 V 0b Obsolete
3 V 1b 1 = Advanced Power Management feature set enabled
2 F 0b 1 = CFA feature set supported
1 F 0b 1 = READ/WRITE DMA QUEUED command supported
0 F 1b 1 = DOWNLOAD MICROCODE command supported
87 Command set/feature enabled/supported
15 F 0b Shall be cleared to zero
14 F 1b Shall be set to one
13 F 1b 1 = IDLE IMMEDIATE with UNLOAD FEATURE supported
12 V 0b Reserved for technical report- INCITS tr-37-2004 (TLC)
11 V 0b Reserved for technical report- INCITS TR-37-2004 (TLC)
10–9 F 00b Obsolete
8 F 1b 1 = 64-bit word wide name supported
7 F 0b 1 = WRITE DMA QUEUED FUA EXT command supported
6 F 1b 1 = WRITE DMA FUA EXT and WRITE MULTIPLE FUA EXT
commands supported
5 F 1b 1 = General Purpose Logging feature set supported
4 V 0b Obsolete
3 V 0b 1 = Media Card Pass Through Command feature set suppor-
ted
2 V 0b 1 = Media serial number is valid
1 F 1b 1 = SMART self-test supported
0 F 1b 1 = SMART error logging supported
Device ID
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
23
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD
Table 16: Identify Device (Continued)
See Note 1 for setting definitions
Word Bit(s) Setting Default Value Description
88 0b Ultra DMA modes
15 0b Reserved
14 0b 1 = Ultra DMA mode 6 is selected
0 = Ultra DMA mode 6 is not selected
13 0b 1 = Ultra DMA mode 5 is selected
0 = Ultra DMA mode 5 is not selected
12 0b 1 = Ultra DMA mode 4 is selected
0 = Ultra DMA mode 4 is not selected
11 0b 1 = Ultra DMA mode 3 is selected
0 = Ultra DMA mode 3 is not selected
10 0b 1 = Ultra DMA mode 2 is selected
0 = Ultra DMA mode 2 is not selected
9 0b 1 = Ultra DMA mode 1 is selected
0 = Ultra DMA mode 1 is not selected
8 0b 1 = Ultra DMA mode 0 is selected
0 = Ultra DMA mode 0 is not selected
7 0b Reserved
6 1b 1 = Ultra DMA mode 6 and below are supported
5 1b 1 = Ultra DMA mode 5 and below are supported
4 1b 1 = Ultra DMA mode 4 and below are supported
3 1b 1 = Ultra DMA mode 3 and below are supported
2 1b 1 = Ultra DMA mode 2 and below are supported
1 1b 1 = Ultra DMA mode 1 and below are supported
0 1b 1 = Ultra DMA mode 0 IS supported
89 (O)F 0001h Time required for security erase unit completion
90 (O)F 0001h Time required for enhanced security erase completion
91 (O)V 00FEh Current advanced power management value
92 (O)V FFFEh Master Password Revision Code
Device ID
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
24
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD
Table 16: Identify Device (Continued)
See Note 1 for setting definitions
Word Bit(s) Setting Default Value Description
93 Shall be 0000h for SATA devices
15 0b Shall be cleared to zero
14 0b Shall be set to one
13 0b 1 = Device detected CBLID-above V
0 = device detected CBLID-below V
Device 1 hardware reset result
Device 0 shall clear these bits to zero Device 1 shall set these bits as follows:
12 0b Reserved
11 0b 0 = Device 1 did not assert PDIAG-
1 = Device 1 asserted PDIAG-
10–9 These bits indicate how Device 1 determined the device
number: 00 = Reserved 01 = a jumper was used 10 = the CSEL signal was used 11 = some other method was used or the method is un­known
8 0b Shall be set to one
Device 0 hardware reset result. Device 1 shall clear these
bits to zero. Device 0 shall set these bits as follows:
7 0b Reserved
6 0b 0 = Device 0 does not respond when Device 1 is selected.
1 = Device 0 responds when Device 1 is selected.
5 0b 0 = Device 0 did not detect the assertion of DASP-
1 = Device 0 detected the assertion of DASP-
4 0b 0 = Device 0 did not detect the assertion of PDIAG-
1 = Device 0 detected the assertion of PDIAG-
3 0b 0 = Device 0 failed diagnostics.
1 = Device 0 passed diagnostics.
2–1 00b These bits indicate how Device 0 determined the device
number: 00 = Reserved 01 = a jumper was used 10 = the CSEL signal was used 11 = some other method was used or the method is un­known
0 0b Shall be set to one
94 15–8 F 00h Vendor's recommended acoustic management value
7–0 V 00h Current automatic acoustic management value
95 (O)V 0000h Stream Minimum Request Size
IH
IL
Device ID
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
25
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD
Device ID
Table 16: Identify Device (Continued)
See Note 1 for setting definitions
Word Bit(s) Setting Default Value Description
96 (O)V 0000h Streaming Transfer Time – DMA
97 (O)V 0000h Streaming Access Latency – DMA and PIO
98 (O)F 0000h 0000h Streaming Performance Granularity (98-99)
100 V Varies by capacity Maximum user LBA for 48-bit Address feature set
104 (O)V 0000h Streaming Transfer Time – PIO
105 ( )F 0008h Maximum number of 512-byte blocks of LBA Range Entries
per DATA SET MANAGEMENT command
106 Physical sector size/logical sector size
15 F 0b Shall be cleared to zero
14 F 1b Shall be set to one
13 F 1b 1 = Device has multiple logical sectors per physical sector
12 F 0b 1 = Device logical sector longer than 256 words
11–4 F 00000000b Reserved
3–0 F 0011b 2^x logical sectors per physical sector
107 (O)F 0000h Inter-seek delay for ISO-7779 acoustic testing in microsec-
onds
108 15–12 F 0101b NAA (3-0)
11–0 000000001010b IEEE OUI (23-12)
109 15–4 F 000001110101b IEEE OUI (11-0)
3–0 Varies Unique ID (35-32)
110 (M)F Varies 5-0 Unique ID (31-16)
111 (M)F Varies Unique ID (15-0)
112 (O)F 0000h 0000h
0000h 0000h
116 (O)V 0000h Reserved for INCITS TR-37-2004
117 (O)F 0000h 0000h Words per Logical Sector
Reserved for 12- bit word-wide name extension to 128 bits
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
26
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD
Device ID
Table 16: Identify Device (Continued)
See Note 1 for setting definitions
Word Bit(s) Setting Default Value Description
119 Commands and feature sets supported (continued from
words 84–82)
15 F 0b Shall be cleared to zero
14 F 1b Shall be set to one
13–8 F 00000001b Reserved
7 F 0b 1 = Extended Power Conditions feature set is supported
6 F 0b 1 = Extended Status Reporting feature set is supported
5 F 0b 1 = Free-fall control feature set is supported
4 F 1b 1 = The DOWNLOAD MICROCODE command with mode 3 is
supported
3 F 1b 1 = READ LOG DMA EXT and WRITE LOG DMA EXT com-
mands are supported
2 F 1b 1 = The Write-Read-Verify feature set is supported
1 F 1b 1 = Disable Data Transfer After Error Detection feature set is
supported
0 F 0b Reserved for DDT
120 Commands and feature sets supported or enabled (contin-
ued from words 87–85)
15 0b Shall be cleared to zero
14 1b Shall be set to one
13–6 00000000b Reserved
5 0b 1 = Free-fall control feature set is enabled
4 1b 1 = The DOWNLOAD MICROCODE command with mode 3 is
supported
3 1b 1 = The READ LOG DMA EXT and WRITE LOG DMA EXT
commands are supported
2 1b 1 = The WRITE UNCORRECTABLE EXT command is supported
1 0b 1 = The Write-Read-Verify feature set is enabled
0 0b 1= Feature set "Disable Data Transfer After Error Detection"
is enabled 0 = Feature set "Disable Data Transfer After Error Detec­tion" is disabled
121 F 0000h 0000h
0000h 0000h 0000h 0000h
127 (O) 0000h Obsolete
Reserved for expanded supported and enabled settings
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
27
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD
Table 16: Identify Device (Continued)
See Note 1 for setting definitions
Word Bit(s) Setting Default Value Description
128 Security status
15–9 F 0000000b Reserved
8 V 0b Security level 0 = High, 1 = Maximum
7–6 F 00b Reserved
5 F 1b 1 = Enhanced security erase supported
4 V 0b 1 = Security count expired
3 V 0b 1 = Security frozen
2 V 0b 1 = Security locked
1 V 0b 1 = Security enabled
0 F 1b 1 = Security supported
129–159 ( )X Vendor specific
data
160 CFA power mode 1
15 F 0b Word 160 supported
14 F 0b Reserved
13 F 0b CFA power mode 1 is required for one or more commands
12 V 0b CFA power mode 1 disabled
11–0 F 000000000000b Maximum current in ma
161 X 0000h 0000h
0000h 0000h 0000h 0000h
0000h
168 15–4 F 000h Reserved
3-0 F 5h Device Nominal Form Factor
169 DATA SET MANAGEMENT command support
15–1 F 000000000000000bReserved
Vendor specific
implemented by the device
Reserved for assignment by the CompactFlash Association
Device ID
0 F 1b 1 = The Trim bit in the DATA SET MANAGEMENT command
is supported
170 F 0000h 0000h
Additional product identifier
0000h 0000h
174 F 0000h 0000h Reserved
176 (O)V Varies Current media serial number (60 ASCII characters)
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
28
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD
Device ID
Table 16: Identify Device (Continued)
See Note 1 for setting definitions
Word Bit(s) Setting Default Value Description
206 SCT Command Transport
15–12 X 0000b Vendor-specific
11–6 F 000000b Reserved
5 F 1b SCT Command Transport Data Tables supported
4 F 1b CT Command Transport Features Control supported
3 F 0b SCT Command Transport Error Recovery Control supported
2 F 1b SCT Command Transport Write Same supported
1 F 0b SCT Command Transport Long Sector Access supported
0 F 1b SCT Command Transport supported
207 ( )F 0000h 0000h Reserved for CE-ATA
209 (O) Alignment of logical blocks within a larger physical block
15 F 0b Shall be cleared to zero
14 F 1b Shall be set to one
13–0 F 00000000000000b Logical sector offset within the first physical sector where
the first logical sector is placed
210 (O)V 0000h 0000h Write-Read-Verify Sector Count Mode 3 Only
212 (O)F 0000h 0001h Verify Sector Count Mode 2 Only
214 (O) NV Cache Capabilities
15–12 F 0000b NV Cache feature set version
11–8 F 0000b NV Cache Power Mode feature set version
7–5 F 000b Reserved
4 V 0b 1 = NV Cache feature set enabled
3–2 F 00b Reserved
1 V 0b 1 = NV Cache Power Mode feature set enabled
0 F 0b 1 = NV Cache Power Mode feature set supported
215 (O)V 0000h NV Cache Size in Logical Blocks (LSW)
216 (O)V 0000h NV Cache Size in Logical Blocks (MSW)
217 (M)F 0001h Nominal media rotation rate (ATA8-ACS 1699-D Revision 6)
218 (O)V 0000h Reserved
219 NV Cache Options
15–8 F 00h Reserved
7–0 F 00h Device Estimated Time to Spin Up in Seconds
220 15–8 F 00h Reserved
7–0 V 00h Write-Read-Verify feature set current mode
221 0000h Reserved
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
29
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD
Device ID
Table 16: Identify Device (Continued)
See Note 1 for setting definitions
Word Bit(s) Setting Default Value Description
222 Transport Major revision number. 0000h or FFFFh = device
does not report version
15–12 0001b Transport Type - 0 = Parallel, 1 = Serial, 2-15 = Reserved
Parallel (Type = 0) Serial (Type = 1)
11–7 000000b Reserved Reserved
6 1b Supports SATA Rev 3.1
5 1b Supports SATA Rev 3.0
4 1b Supports SATA Rev 2.6
3 1b Supports SATA Rev 2.5
2 1b Supports SATA II: Extensions
1 1b Supports SATA 1.0a
0 1b Supports ATA8-APT ATA8-AST
223 (M)F 0000h Transport Minor revision number
224 ( )F 0000h 0000h
0000h 0000h 0000h 0000h 0000h 0000h 0000h 0000h
234 (O)F 0001h Minimum number of 512 byte units per DOWNLOAD MI-
235 00FFh Maximum number of 512 byte units per DOWNLOAD MI-
236 0000h 0000h
0000h 0000h 0000h 0000h
0000h
243 4000h Bit 14 = 1; Supports FDE security features
244 0000h 0000h
0000h 0000h 0000h 0000h 0000h 0000h 0000h 0000h
0000h
255 (M)F Integrity word
15–8 varies Checksum
7–0 A5h Signature
Reserved for CE-ATA
CROCODE command for mode 3
CROCODE command for mode 3
Reserved
Reserved
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
Note:
1. F = The content of the word is fixed and does not change. V = The content of the word is variable and may change depending on the state of the device or the commands executed by the device. X = The content of the word may be fixed or variable. R = The content of the word is reserved and will be zero.
30
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD

Commands

Table 17: Supported ATA Command Set
See ATA-8 standard for command details
Command Name Command Code (hex)
CHECK POWER MODE 98h or E5h
DEVICE CONFIGURATION RESTORE B1h/C1h
DEVICE CONFIGURATION FREEZE LOCK B1h/C3h
DEVICE CONFIGURATION IDENTIFY B1h/C1h
DEVICE CONFIGURATION SET B1h/C3h
DOWNLOAD MICROCODE 92h
EXECUTE DEVICE DIAGNOSTIC 90h
FLUSH CACHE E7h
FLUSH CACHE EXT EAh
IDENTIFY DEVICE ECh
IDLE E3h or 97h
IDLE IMMEDIATE E1h or 95h
INITIALIZE DEVICE PARAMETERS 91h
NOP 00h
READ BUFFER E4h
READ DMA (with retry) C8h
READ DMA (without retry) C9h
READ DMA EXT 25h
READ FPDMA QUEUED 60h
READ LOG EXT 2Fh
READ MULTIPLE C4h
READ MULTIPLE EXT 29h
READ NATIVE MAX ADDRESS F8h
READ NATIVE MAX ADDRESS EXT 27h
READ SECTOR(S) EXT 24h
READ SECTOR(S) (with retry) 20h
READ SECTOR(S) (without retry) 21h
READ VERIFY SECTOR EXT 42h
READ VERIFY SECTOR(S) (with retry) 40h
RECEIVE FPDMA QUEUED 65h
SANITIZE DEVICE B4h
SCT WRITE SAME 02h/0001h
02h/0002h 02h/0101h 02h/0102h
SCT RETURN ERROR RECOVERY CONTROL 030h/01h
SCT SET ERROR RECOVERY CONTROL 03h/01h
Commands
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
31
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD
Table 17: Supported ATA Command Set (Continued)
See ATA-8 standard for command details
Command Name Command Code (hex)
SCT SET FEATURE CONTROL 04h/01h
SCT RETURN FEATURE CONTROL 04h/02h
SCT RETURN FEATURE OPTION FLAG 04h/03h
SCT RETURN SCT DATA TABLE 05h/01h
SECURITY DISABLE PASSWORD F6h
SECURITY ERASE PREPARE F3h
SECURITY ERASE UNIT F4h
SECURITY FREEZE LOCK F5h
SECURITY SET PASSWORD F1h
SECURITY UNLOCK F2h
SEEK 7xh
SEND FPDMA QUEUED 64h
SET FEATURES EFh
SET MAX ADDRESS F9h
SET MAX – FREEZE LOCK F9h/04h
SET MAX – LOCK F9h/02h
SET MAX ADDRESS EXT 37h
SET MULTIPLE MODE C6h
SET MAX – SET PASSWORD F9h/01h
SET MAX – UNLOCK F9h/03h
SLEEP E6h or 99h
SMART DISABLE OPERATIONS B0h/D9h
SMART ENABLE OPERATIONS B0h/D8h
SMART ENABLE/DISABLE AUTOSAVE B0h/D2h
SMART EXECUTE OFF-LINE IMMEDIATE B0h/D4h
SMART READ DATA B0h/D0h
SMART READ LOG SECTOR B0h/D5h
SMART RETURN STATUS B0h/DAh
SMART WRITE LOG B0h/D6h
STANDBY E2h or 96h
STANDBY IMMEDIATE E0h or 94h
TRUSTED NON-DATA 5Bh
TRUSTED RECEIVE 5Ch
TRUSTED RECEIVE DMA 5Dh
TRUSTED SEND 5Eh
TRUSTED SEND DMA 5Fh
WRITE BUFFER E8h
Commands
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
32
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.
M500 2.5-Inch NAND Flash SSD
Table 17: Supported ATA Command Set (Continued)
See ATA-8 standard for command details
Command Name Command Code (hex)
WRITE DMA (with retry) CAh
WRITE DMA (without retry) CBh
WRITE DMA EXT 35h
WRITE DMA FUA EXT 3Dh
WRITE FPDMA QUEUED 61h
WRITE LOG EXT 3Fh
WRITE MULTIPLE C5h
WRITE MULTIPLE EXT 39h
WRITE MULTIPLE FUA EXT CEh
WRITE SECTOR(S) (with retry) 30h
WRITE SECTOR(S) EXT 34h
WRITE UNCORRECTABLE EXT 45h
Commands
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
33
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.

Compliance

M500 2.5-Inch NAND Flash SSD
Compliance
Micron SSDs comply with the following:
• RoHS “green”
• CE (Europe): EN55022, 2006 Class B and EN55024, 1998 + A1: 2001 + A2:2003
• FCC: CFR Title 47, Part 15, ICES-003, all Class B
• UL (US): approval to UL-60950-1, 2nd Edition, 2007-03-27, IEC 60950-1:2005, 2nd Ed­ition
• BSMI (Taiwan): approval to CNS 13438
• C-TICK (Australia, New Zealand): approval to AS/NZS CISPR22
• KCC RRL (Korea): approval to KCC MU2-C30025, KCC MU2-C30018 Class B
• W.E.E.E.: Compliance with EU WEEE directive 2002/96/EC. Additional obligations may apply to customers who place these products in the markets where WEEE is en­forced.
• TUV (Germany): approval to IEC60950/EN60950
• V
CCI
• IC (Canada):
- This Class B digital apparatus complies with Canadian ICES-003.
- Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

FCC Rules

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide rea­sonable protection against harmful interference in a residential installation. This equip­ment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio com­munications. However, there is no guarantee that interference will not occur in a partic­ular installation. If this equipment does cause harmful interference to radio or televi­sion reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following meas­ures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the re­ceiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
34
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.

Package Dimensions

D&T M3X0.5
(4 PLCS)
D&T M3X0.5 (2 PLCS) (both sides)
%CL drive
%CL connector
100.50mm/3.957in for reference only
0.30mm/0.012in for reference only
14.00mm
0.551in
90.60mm
3.567in
4.07mm
0.160in
61.72mm
2.430in
2.6mm RAD
0.10in (4 PLCS)
69.85mm ±0.25
2.750in ±0.010
14.00mm
0.551in (both sides)
90.60mm
3.567in (both sides)
3.00mm
0.118in (2 PLCS) (both sides)
3.50mm ±0.38
0.138in ±0.015
13.43mm/0.529in
for reference only
6.90mm
+0.10
–0.40
0.272in
+0.004
–0.016
9.40mm
0.370in
100.20mm ±0.25
3.945in ±0.010
4.80mm ±0.38
0.189in ±0.015
Figure 4: 2.5-Inch Package – 7mm
M500 2.5-Inch NAND Flash SSD
Package Dimensions
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
35
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.

References

M500 2.5-Inch NAND Flash SSD
References
• Serial ATA: High-speed serialized AT attachment, Serial ATA working group, available at www.sata-io.org
• SATA 3.1 GOLD, and the following:
– DEVSLP, SATA31_TPR_C108 rev. 1.0a 10/24/2011 – SATA TP #37, Standard SATA Connector 3.3V Power Pin Assignments, Rev. 1.1
10/12/2011
– SATA TP #39, DEVSLP Assignment on Standard SATA Connector, Rev. 01 01/02/12
• ATA-8 ACS2 (T13/2015-D, Revision 4), and the following:
– Device Internal Logs (supports SSD Telemetry) – IDFY Device Data Logs (supports DEVSLP)
• TCG Storage Security Subsystem Class Opal; Specification 2.00 Revision 1.00, Feb 24, 2012
• TCG Core Specification; Specification 2.00 Revision 2.00, Nov 4, 2011
• TCG Storage Interface Interactions: Specification Version 1.02 Revision 1.00 30 De­cember, 2011
• IEEE-1667: "Standard Protocol for Authentication in Host Attachments of Transient Storage Devices"
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN
36
Micron Technology, Inc. reserves the right to change products or specifications without notice.
© 2013 Micron Technology, Inc. All rights reserved.

Revision History

Rev. G– 8/14

Rev. F– 6/14

Rev. E– 9/13

Rev. D– 7/13

Rev. C– 5/13

M500 2.5-Inch NAND Flash SSD
Revision History
• Added note 2 and note 4 to Table 8: Drive Lifetime – Client Computing
• Added note 2 and note 4 to Table 9: Drive Lifetime – Sequential Input
• Removed the AW = 2.5-inch (5mm) drive form factor from the Part Number Chart
• Added a power cycle note to thermal monitoring
• Revised thermal monitoring.
• Changed endurance data and added an endurance footnote on cover page.
• Revised part number chart.
• Revised and divided the drive lifetime table into two tables, a client computing table and a sequential input table, with new data for these table categories.

Rev. B– 2/13

• Status changed from Preliminary to Production.
• Updated Physical Configuration section.
• Updated Electrical Characteristics section.

Rev. A – 1/13

• Initial release.
8000 S. Federal Way, P.O. Box 6, Boise, ID 83707-0006, Tel: 208-368-4000
www.micron.com/products/support Sales inquiries: 800-932-4992
Micron and the Micron logo are trademarks of Micron Technology, Inc.
All other trademarks are the property of their respective owners.
This data sheet contains minimum and maximum limits specified over the power supply and temperature range set forth herein.
Although considered final, these specifications are subject to change, as further product development and data characterization some-
times occur.
PDF: 09005aef84fed121 m500_2_5_ssd.pdf - Rev. G 8/14 EN