Thank you for purchasing our products.
Carefully read this User's Guide(in particular, precautions for safety) before using a
product.
This product is subject to change without prior notice.
The company is not responsible for any safety accidents caused by abnormal operation
of the product.
Index
1、Warning and Ca ution
2、The fu nction and name of each part
3、Terminalwiringdiagram
4、Features and main function
5、Package contents
6、System layout
7、Wiring diagram
8、Installation method
9、Cable specification
10、Functions in common use
11、System main menu
12、Specification
1
3
4
4
5
5
6
7
8
9
13
14
Version: V1. 0
1、Warning and caution
Make sure to follow the instructions to prevent any danger or property losses.
It i ndicate s pr ohibiti on .
War ni ng
De ath or seri ou s
in jury is exp ec ted.
warni ng
Do not pu t the plu g in the
socke t simul taneo usl y.
It may ge nerat e abnor mal
heat or c ause a fi re.
Do not us e water, t hinne r or
a deter gent us ed to was h oil
produ cts whe n you was h the
exter ior.
Make su re to was h it by usi ng
a dry clo th to pre vent an y
break down or e lectr ic sh ock.
It i ndicate s di sassemb ly.
It i ndicate s pr ohibiti on o f contact .
It i ndicate s do s and don’t s.
It i ndicate s th at the plug s ho uld be pull ed o ut from the
so cket.
NO
Do not co nnect t o other
produ cts whi le in use .
It may ca use bre akdow n.
NO
Do not in stall t he prod uct i n a
humid p lace.
It may ca use an el ectri c
shock o r a fire.
NO
Do not fo rcibl y bend th e cor d
or put a he avy obj ect on th e
produ ct.
It may ca use a fir e.
NO
Do not fo rcibl y pull ou t the
cord fr om the so cket.
If the co rd is dam aged, i t
may cau se a fire o r an
elect ric sho ck.
NO
NO
Do not pu t the plu g in the
socke t with a we t hand.
It may ca use an el ectri c
shock .
NO
Do not di sasse mble, r epa ir
or modi fy the pr oduct .
It may ca use a fir e, an ele ctr ic
shock o r an inju ry due to
malfu nctio n of the pr odu ct.
Do not us e AC circu it brea ker.
It may ca use an el ectri c sho ck.
Page1
It i ndicate s pr ohibiti on .
Ca ution
A inj ury or prop er ty
lo sses are ex pe cted.
CAUTI ON
Th e so ck et h ol es
ar e la ge r th an
us ua l.
If the so cket ho les are l arg er
than no rmal, d o not put t he
plug.
It may ca use an el ectri c sho ck
or a fire .
Do not pu t a heavy o bject o n
the pro duct.
It may ca use a bre akdow n.
It i ndicate s di sassemb ly.
It i ndicate s pr ohibiti on o f contact .
It i ndicate s do s and don’t s.
It i ndicate s th at the plug s ho uld be pull ed o ut from the
so cket.
NO
Make su re that d ust or
forei gn subs tance s are n ot
gathe red on th e produ ct.
Do not di sasse mble or g ive a n
impac t to the pr oduct .
NO
Make su re to pre vent fo rei gn
subst ances f rom ent eri ng
the pro duct.
It may ca use a bre akdow n.
NO
Avo id d ire ct rays o f the sun
or heat ing dev ices at a t ime
of inst allat ion.
NO
Insta ll the pr oduct i n a fla t and
stabl e place .
Other wise, i t may not f unc tion
prope rly.
Page2
Pull th e plug if t he prod uct i s
not use d for a lon g time.
If the pr oduct g enera tes
stran ge soun d, make s ure t o
pull th e plug im media tel y
and con tact se rvice c ent er.
2、The function and name of each part
10
1). Return button: Return/hang up
2). Indicator light: Power indicator light
3). Menu button: Enter system menu/Confirm
4). Navigation button Up: Choose/Adjust
5). Unlock button: Unlock
6). Navigation button down: Choose/ Adjust
7). Monitor button: Monitor
8). Answer button: Answer/Call
9). Power on/off
10). LCD
1
2
3
4
5
6
7
8
9
Page 3
3、Terminal wiring diagram
Groun d
CC TV 2
Groun d
SLAVE MONITOR
Vi deo
Audio
Da ta
Groun d
PO RT 3
POR T 3
POR T 4
CCTV
CC TV 1
PO RT 4
ForEx ternal power supply
DOOR2
Audio 2
Groun d
PO RT 2
POR T 1
POR T 2
DOOR1
Audio 1
KE Y 1
Vi deo 1
Pow er 1
Groun d
KE Y 2
Vi deo 2
Pow er 2
PO RT 1
4、Features and main function
MODEL LIST
1).Features
7" color screen
Hands free design
Comfortable touch button
OSD me nu with various setting
12 chord call melodies
Easy to install and operate
Page 4
2).Main functio ns
Lock control
Brightness, contrast, talk volume, color and display mode adjustable.
Real-time monitoring of door station or CCTV camera
“Do not disturb” function
Broadcast and intercom call to other monitors
Monitor listening to other indoor monitors
Call transfer to other indoor monitors
5、Package contents
U
se
r m
a
unal
Monitor
2*M 5* 30
fixing scr ews
User manua l
2x5 pin conn ect or
(red/blu e/y ell ow/
white/br own )
Wal l bra cke t
4 pin connec tor
(red/blu e/y ell ow/
white)
2* Exp ans ion b olt
4 pin connec tor
(white/b lue /
white/bl ue)
Desiccan t
Adaptor
6、System layout
The po rt 2 connect to d oor station
The sy stem can support maximum1 master monitor, 3 sub monitors, 2 door
stations and 8 CCTV cameras.
Sub Mon ito r
CCTV1
Doo r 1
Doo r 2
Maste r mon ito r
CCTV1
Sub Mon ito r
CCTV1
Sub Mon ito r
CCTV1
CCTV2
CCTV2
CCTV2
CCTV2
Page 5
7、Wiring diagram
a
ele ctron ic lock 2
-NO
-CO M
CCVT 1
CCVT 2
Doo r 2
CCVT 1
CCVT 2
CCVT 1
CCVT 2
Solution1
P4
P2
A D
G N D
PWR
V D
P4
P2
P4
P2
J4
CCTV 1
G N D
CCTV 2
G N D
A D 2
G N D
PWR2
V D 2
KE Y2
J4
CCTV 1
G N D
CCTV 2
G N D
A D 2
G N D
PWR2
V D 2
KE Y2
J4
CCTV 1
G N D
CCTV 2
G N D
A D 2
G N D
PWR2
V D 2
KE Y2
P3
P1
P3
P1
P3
P1
AD -1
G N D
DATA
VD -1
A D 1
G N D
PWR1
V D 1
KE Y1
AD -1
G N D
DATA
VD -1
A D 1
G N D
PWR1
V D 1
KE Y1
AD -1
G N D
DATA
VD -1
A D 1
G N D
PWR1
V D 1
KE Y1
ROOM1
A D
G N D
PWR
V D
Door S tatio n 1
ROOM2
ROOM3
NO
C
NC
ele ctron ic rela y 1
b
J4
P4
P3
AD -1
CCTV 1
CCVT 1
CCVT 2
P2
G N D
CCTV 2
G N D
A D 2
G N D
PWR2
V D 2
KE Y2
P1
VD -1
A D 1
G N D
KE Y1
G N D
DATA
PWR1
V D 1
ROOM4
Note : (a)Door station unlock wiring: electronic lock 2+external power supply.
(b)I ndoor monit or unlock wir ing: electronic relay 1 to KEY1 and GND.
(c)J 4 port is for ext ernal power.
Page 6
8、Installation method
SINGLE MONITOR INSTALLATION
1. Refer to relevant wiring diagram for the system you have chosen and ensure you
have the correct cable.
2. Determine the monitor installation position:
-sug gest to insta ll at 1.5~1.6 Meters;
3. Ensure no power supply connection before installation finished
4. Ins tall the bracket on the wall
5. Connect cables as per the wiring diagram indicated.
6. Fix t he monitor onto the bracket.
7. Connect power when doorbell is installed.
150cm
Page 7
Ca ble S pec ifi cat ion
9、Cable specification
Our sy stem has 2 solutions to unlock the door: Unlock signal from door station or
unlock signal from monitor.(The cable shield wire needs to be grounded)
Cable specification is:
Dist ance between monitor and door station is less than 30 meters, shielded
4 x 0.5m m² cable is OK;
AD1
GND
indoor monitor
PWR 1
KEY 1
VD1
Red
Blue
Yellow
white
2
3
4
Red
1
2
Blue
Yellow
3
4
AD
GND
PWR
White
VD
door station
COM
NO
Green
Brown
-
+
12V
+
-
electronic lock
2
1
Dist ance exceed 30 meters, please choose coaxial cable for video with another
shie lded 2*0.5mm² cable or composite coaxial cable.
1
AD1
GND
indoor monitor
PWR 1
KEY 1
VD1
Red
Blue
Yellow
White
2
3
1
2
3
Red
Blue
Yellow
White
door station
AD
GND
PWR
VD
COM
NO
-
Green
+
12V
Brown
electronic lock
+
-
When u sing KEY wire from monitor to unlock please use electron ic relay as sho wn
on Pag e 6.
Page 8
10、Functions in common use
1). How to answer the call and transfer the call to other indoor monitors
When call from door station or other indoor monitor, the indoor monito r(s) will
chime, short press to answer the call. If no one answers, the monitor(s)
shall be back to standby status after chime time end.
When the monitor is chiming, or when talk with visitor, short press can
unlock the door.
When talking with one door station, if some one calls at the other door station,
the sc reen will show relevant indication, short press can switch to talk
with the other visitor.
When at talking status, short press can transfer the call to other indoor
monitors.
When at talking status, short press will swit ch the screen t o other
video channel and keep monitoring status; while back to the previous video
channel, the device will be back to talk status.
When at talking status, long press , the microp hone will be disabled,
long press again ca n enable the microphone, screen will show
relevant indication when doing the above operations. The a bove operat ion is
only valid in the present calling, the microphone shall be enabled automatical ly
afte r the call ends.
2). How to use monitoring function
At sta ndby status, short press to monitor Doo r 1, short pres s again can
switch to another video channel. When mon itoring doo r station cha nnel, short press
can ta lk to door stat ion.
When talk with door station, short press can un lock the door. If enable
MONI TOR UNLOCK function in advanced setting , user can shor t press to
unlock the door when monitoring door station.
If at CC TV status, th e longest monitoring time is 4 hours.
Page 9
3). How to make internal call
At sta ndby status, user can short press to entr e intercom ca ll interface, then short
press to choose cal l target, pre ss to confirm c alling.
For in door monitors installed in multi- apartment system, user can input target room
no. th en start calling. "0"i s the address n o. for manage ment center.
4). How to make broadcast(handset model does not have this function)
At sta ndby status, user can long press to enter b roadcast st atus direct ly. It
shall broadcast to all indoor monitors in the system and could not choose broadcast
targ et.
5). How to use the monitor listening function
At sta ndby status, long press to e nter the moni tor listeni ng interface, then press
to cho ose the monitor listening target, press to confirm m onitor listening.
The maximum monitor listening time is 8 hours.
Atte ntion:
a. At monitor listening status, you can hear the voice from the opposite side, but they
can’t hear your voice.
b. At bro adcasting status, your voice can be heard by the opposite side, but you can’t
hear the voice from them
c. There must be at least 2 monitors in the system for functions 3), 4) and 5)..
6). How to adjust the Volume, Brightness, Chrominance, contrast ratio and
display scale.
At vid eo display or audio play interface, user can short press or to adjust
the vo lume or brightness.
At vid eo display status, when adjust volume/brightness interface, short press
can switch to adjust other parameters interface: Volume, Brightness, Chrominance,
contrast ratio & display scale.
Page 10
7). How to set the address of indoor monitor.
The default address is Room1. Optional Room1~Room4. The mast er monitor wh ich
connects to door station directly,
should be set as Room1. If the system has 2 or more than 2 indoor monitors, can’t set a
same address in 2 monitors, or the system can’t work normally & that option will caution
in red color.
8). How to enter system setting?
At sta ndby status, users can long press to ente r system sett ings menu.
9).“Don’t disturb” function
You can use SYSTE M SETTINGS me nu to turn “DO NO T DISTURB” function on or off.
When t urn on this function, the indoor monitor shall not chime when someone calls to it.
10). How to enter advanced settings?
In the m odels that are not installed in a multi-apartment system, users can enter
advanced setting by restarting the monitor, and long press at welcome screen.
In the m odels that are connected in a multi-apartment system, there isn’t a welcome
screen after restarting monitor. The indicat or shall flic ker a few times a fter restar ting
the mo nitor, long press , then the mo nitor shall enter advanced settings menu.
NOV 12 2014 10: 10:22
VCOMDC
UNLOCK TI ME
MONITOR U NLOCK
ADVANCED SETTING
140
01S
ENABLE
Page 11
(A). VCOMDC: It's fo r adjusting the sharpness of the LCD. The factory has set
a most suitable value before the products leaving the factory. Please do not
change it casually, or the screen may not display normally.
(B). UNLOCK TIME: I t can be set from 1 S to 10S. Note: m ost electri c locks only need
1 second unlocking time, please do not change it if there’s no suc h needs for you r lock,
because too long time unlock power might cause damage to your lock.
(C). MONITOR UNLOCK: If turn this function on, the door will be open by pressin g
unlock button at monitoring state or intercom/ talking state. If turn it off, the door can
only be open at intercom/ talking state by pressing unlock button.
Note: As some of the advanced setting may bring security risk, please do not change it
randomly.
Page 12
11、System setting
No. Setting items Options Notes
1 LANGUAGE Default English(Russian optional)
2 CHIME TIME Default 30seconds。(10~60 seconds adjustable)
3 CHIME VOLUME Default 07, 01~10 adjustable.
4 RING TYPE
Door1 ring type 01 by default, 00-11 optionals
Door2 ring type 02 by default , 00-11 optionals
Intercom ring type 03 by default , 00-11 optionals
5 DO NOT DISTURB
Off by default, at the ringing, intercom between
monitors, broadcast status, the LED indicator will
flicker when turn on “DO NOT DISTURB” function.
6
CAN BE
Off by default, it can be monitored by other indoor
intercoms in the system when turn on this function.
7 RINGTONE REPEAT If disabled, the monitor shall chime only once.
8 DEVICE ADDRESS
Room1/2/3/
4
Master monitor must be set as ROOM
1, and the option will be yellow if two
monitors set the same address.
9 PORT4 STATE None / CCTV1 / CCTV1&2
10 MONITOR UNLOCK Press button to unlock
11 RESTORE DEFAULT Restore the system to default settings.
In sta ndby status ,press butto n to enter system setting menu.
MONITORED
Page 13
12、Specification
NO.
1
2
3
4
5
6
7
ltems
Power supply
Power consumption
Operation
temperature
Operation humidity
LCD size
Intercom mode
Connection
Content
AC100-240V 50/60Hz
DC 15V 1A(External)
7W(Max).
0.7W(Standby)
0℃ to +40℃
095% -%
7 inch
Hands- free
4 wires
8
Dimension
9
Weight
The parameters of product are subject to changes withou t pr io r no ti ce .
Page 14
210*116*25mm
430g
Loading...