BEFORE YOU BEGIN
This quick reference guide explains basic installation guidelines for
®
mounting the Micro Motion
Model 3300/3500 applications platform in a
panel cutout.
For information on I.S. applications, refer to Micro Motion ATEX, UL, or CSA installation instructions.
For complete instructions about configuration, maintenance, and service, refer to the instruction manual shipped with the transmitter.
WARNING
Improper installation in a hazardous area can cause an explosion.
For information about hazardous applications, refer to Micro Motion ATEX, UL, or CSA installation instructions, shipped with the transmitter or available from the Micro Motion web site.
WARNING
Hazardous voltage can cause severe injury or death.
Install transmitter and complete all wiring before supplying power.
CAUTION
Improper installation could cause measurement error or flowmeter failure.
Follow all instructions to ensure transmitter will operate correctly.
©2003, Micro Motion, Inc. All rights reserved. Micro Motion is a registered trademark of Micro Motion, Inc. The Micro Motion and Emerson logos are trademarks of Emerson Electric Co. All other trademarks are property of their respective owners.
1
European installations
This Micro Motion product complies with all applicable European directives when properly installed in accordance with the instructions in this quick reference guide. Refer to the EC declaration of conformity for directives that apply to this product.
The EC declaration of conformity, with all applicable European directives, and the complete ATEX Installation Drawings and Instructions are available on the internet at www.micromotion.com/atex or through your local Micro Motion support center.
Installation kit
The installation kit includes a bezel, frame, two mounting brackets with screws, a power supply wiring connector, and a retaining clip assembly for power supply wiring (see Figure 1).
The applications platform fits through a 5 7/16-inch (138 mm) square cutout in a panel that is 5/64 inch (2 mm) to 1/2 inch (13 mm) thick. The bezel provides a IP65 watertight seal between the panel cutout and the applications platform housing.
In addition, the installation kit includes:
A bracketed wiring connector for screw-type connectors (see Figure 5, page 5), or
I/O cables and connectors (see Figure 7, page 7)
Figure 1. Panel-mount installation kit
Frame
Power supply
wiring connector
Retaining-clip
assembly for
power supply wiring
2 x Mounting bracket
with screw
2
Panel thickness:
• 5/64 inch (2 mm) minimum
• 1/2 inch (13 mm) maximum
Bezel
STEP 1. Choosing a location
Choose a location for the transmitter based on the requirements described below.
Environmental requirements
Install the transmitter where ambient temperature is between
4 and
+140 °F (–20 and +60 °C).
Dimensions
If the Model 3300/3500 has screw-type wiring connectors, see Figure 2 for dimensions. If the Model 3300/3500 has I/O cables, see Figure 3, page 4, for dimensions. (See Figures 5 and 7, pages 5 and 7, for illustrations of screw-type connectors versus I/O cables.)
Figure 2. Panel-mount dimensions – screw-type connectors
inches
(mm)
Bezel
6 1/2 (165)
6
(152)
Panel
8 1/2 (216)
Fram e
7 7/8 (200)
4 1/2 (115)
6 11/16
(170)
6
(152)
Approvals
tag
1/2
(12)
Intrinsic safety shield
(Model 3500 only)
3
Figure 3. Panel-mount dimensions – I/O cables
inches
(mm)
6 1/2 (165)
Bezel
6
(152)
6
(152)
Panel
1/2
(12)
Fram e
8 3/4 (222)
Approvals
tag
5 5/16
(135)
6 11/16
(170)
Minimum 4 1/4"
(108 mm) bend radius
Flowmeter cable lengths
Maximum cable length from the sensor to the Model 3500 transmitter is 1000 feet (300 meters).
If you are installing the Model 3300 applications peripheral in combination with a transmitter, the maximum cable length from the transmitter’s frequency output to the Model 3300’s frequency input is 500 feet (150 meters).
STEP 2. Installing the Model 3300/3500 in the panel
Refer to Figure 4, page 5, and follow these steps:
1. Insert the Model 3300/3500 through the cutout.
2. Slide the frame over the housing.
3. Insert the posts on the brackets into the rails on the housing.
4. Tighten the screws evenly to 10 to 14 inch-pounds (1,13 to 1,38 Nm) to ensure a watertight seal between the gasket and the panel.
4
Figure 4. Steps for installation in panel
Step 2.2
Step 2.1
Step 2.3
Step 2.4
STEP 3. Connecting input and output wiring
If the Model 3300/3500 has screw-type connectors:
1. Plug the bracketed wiring connectors onto the terminal strips on the back panel of the Model 3300/3500 (see Figure 5). Tighten the captive screws to secure the bracket to the back panel.
Figure 5. Wiring connectors and terminals – screw-type connectors
Intrinsically safe sensor wiring terminal strip (Model 3500 only)
Non-intrinsically safe input/output wiring terminal strip
Bracketed wiring connector
Intrinsic safety shield (Model 3500 only)
5
2. Connect input and output wiring to the appropriate terminals in the input/output wiring connector. Refer to the card that is inserted into the sleeve on the top panel (shown in Figure 6), and Table 1.
2
Use 24 to 16 AWG (0,25 to 1,5 mm
) twisted-pair shielded wire.
Ground the shields at a single point only.
Figure 6. Input/output wiring terminal card – screw-type connectors
Table 1. Input/output wiring terminals – screw-type connectors
Terminal number Designation
c 2+ a 2 – Primary 4–20 mA output
c 4 + a 4 – Secondary 4–20 mA output
c 6 + a 6 – Frequency input
c 8 + a 8 – Discrete input 1
c 10 + a 10 – Discrete input 2
c 12 + a 12 – Frequency output
c 14 + a 14 – Discrete output 1
c 16 + a 16 – Discrete output 2
c 18 + a 18 – Discrete output 3
c 32 (B line) a 32 (A line) RS-485 output
If the Model 3300/3500 has I/O cables:
1. Plug the bracketed wiring connector onto the terminal strips on the back panel of the Model 3300/3500 (see Figure 7, page 7). Tighten the captive screws to secure the bracket to the back panel.
6
Figure 7. Wiring connectors and terminals – I/O cables
Intrinsically safe
sensor wiring
terminal strip
Connector for sensor wiring
(Model 3500 only)
Cable for sensor wiring
(Model 3500 only)
Non-intrinsically safe input/output wiring terminal strip
Bracketed wiring connector
Connector for input/output wiring
Cable for input/output wiring
2. Attach the supplied I/O terminal block to a DIN rail. The terminal block fits various rail types. See Figure 8, page 8.
3. Plug the connector for input/output wiring onto the I/O terminal block. Tighten the captive screws to secure the connector to the I/O terminal block.
4. Connect input and output wiring to the appropriate terminals on the I/O terminal block. Refer to the label attached to the terminal block (shown in Figure 9, page 8), and Table 2, page 8.
2
Use 24 to 16 AWG (0,25 to 1,5 mm
) twisted-pair shielded wire.
Ground the shields at a single point only.
The I/O terminal block ground is available for continuation of user cable shielding to I/O cable shielding. The cable connector does not connect the I/O cable shielding to the chassis ground.
7
Figure 8. Installing terminal block for I/O wiring on DIN rail
inches
(mm)
2 31/64
(63)
2 37/64
(66)
DIN rail type TS 35 x 7,5
2 1/4
(57)
2 19/64
(59)
DIN rail type TS 15 DIN rail type TS 32
3 3/64
(77)
Label is
mounted
here
DIN rail type TS 35 x 15
Cable for
input/output wiring
Connector
I/O terminal
block
9
(229)
2 15/64
(57)
Table 2. Input/output wiring terminals – I/O cables
Terminal number Designation
1 + 2 – Secondary 4–20 mA output 14 + 15 – Primary 4–20 mA output 3 + 4 – Frequency input 5 + 6 – Discrete input 1 7 + 8 – Discrete input 2 16 + 17 – Frequency output 18 + 19 – Discrete output 1 20 + 21 – Discrete output 2 22 + 23 – Discrete output 3 24 (B line) 25 (A line) RS-485 output
3 17/32
(90)
Figure 9. Input/output wiring terminal card – I/O cables
8
STEP 4. Connecting the Model 3500 to the sensor
To connect the Model 3500 transmitter to a Micro Motion sensor, follow the steps below. If you are installing the Model 3300 applications peripheral, this step is not required.
Sensor wiring depends on the connectors supplied with the Model 3500:
Screw-type connectors
•I/O cables
Follow the steps below to connect the Model 3500 to the sensor.
1. Identify the components:
See Figure 10 for transmitters with screw-type connectors.
See Figure 11, page 10, for transmitters with I/O cables.
Figure 10. Sensor cable to Model 3500 – screw-type connectors
9-wire cable from sensor
black (drain wires from all wire sets)
brown red
green white
blue gray
orange yellow violet
Model 3500
Sensor wiring terminals
(see Figure 5, page 5
c
2
a
c
4
yellow
violet
green
blue
brown
a
6
8
10
12
14
16
18
20
22
24
26
28
30
32
black (drains)
a
orange
a
white
a
gray
a
red
a
a
a
a
a
a
a
a
a
a
c
c
c
c
c
c
c
c
c
c
c
c
c
c
)
9
Figure 11. Sensor cable to Model 3500 – I/O cables
9-wire cable from sensor
black (drain wires from all wire sets)
brown red
green white
blue gray
orange yellow violet
Connect outer braid of
shielded or armored
Model 3500 sensor wiring terminals
Terminal block for sensor wiring
installed on DIN rail
(see Figure 12, page 11)
white
black (drains)
cable here
brown red orange yellow green blue violet gray
2. Prepare the cable according to the instructions in Micro Motion’s 9-Wire Flowmeter Cable Preparation and Installation Guide.
3. Ensure that the cable has 360° shielding, continuous from the transmitter to the sensor’s junction box. Two methods can be used:
Metallic conduit
Shielded or armored cable
Refer to Micro Motion’s 9-Wire Flowmeter Cable Preparation and Installation Guide for specific instructions.
4. At the sensor:
a. Clip the cable drain wires.
b. Connect wiring inside the junction box housing and tighten the
screws to hold the wires in place.
For information on your sensor’s junction box terminals, see the sensor installation manual or Micro Motion’s 9-Wire Flowmeter Cable Preparation and Installation Guide.
10
5. At the transmitter:
For transmitters with screw-type connectors:
a. Connect the color-coded wires to the appropriate terminals.
To identify the terminals, refer to Figure 10, page 9. No bare wires should remain exposed.
b. If using shielded or armored cable, connect the cable braid to
the rear stud, as described in Micro Motion’s 9-Wire Flowmeter Cable Preparation and Installation Guide.
For transmitters with I/O cables:
a. Attach the supplied terminal block for sensor wiring to a DIN
rail. The terminal block fits various rail types (see Figure 12).
b. Plug the connector for sensor wiring onto the terminal block.
Tighten the captive screws to secure the connector to the terminal block.
c. Connect the color-coded wires to the appropriate terminals on
the terminal block. To identify the terminals, refer to Figure 11, page 10. No bare wires should remain exposed.
d. If using shielded or armored cable, connect the cable braid to
the terminal as shown in Figure 11, page 10.
Figure 12. Installing terminal block for sensor wiring on DIN rail
inches
(mm)
2 11/16
(68)
Cable for sensor wiring (attached
to Model 3500)
Connector
Te rm i na l bl oc k fo r
sensor wiring
2 1/2
(63)
2 9/16
(66)
2 5/16
(58)
2 1/4
(57)
TS 35 x 7,5 TS 35 x 15
11
3 1/16
(77)
TS 15 TS 32
9
(229)
STEP 5. Connecting power supply wiring
CAUTION
Improper wiring installation can cause device failure or measurement error.
• To avoid device failure or measurement error, do not install power supply wiring in the same cable tray or conduit as input/output wiring.
• Shut off power supply before installing the applications platform.
• Make sure power supply voltage matches voltage that is indicated on power supply wiring terminals. See Figure 13, page 13.
Connect the Model 3300/3500 to a power supply as follows:
1. Plug in the power supply wiring connector. See Figure 13, page 13.
2. Connect 18 to 14 AWG (0,75 to 2,5 mm
2
) wiring to the power supply
wiring connector.
3. Ground the power supply wiring:
Connect the ground wire to the ground lug for the power supply.
Connect the power supply ground directly to earth ground.
Keep all ground leads as short as possible.
Ensure that all ground wiring has less than 1 ohm impedance.
4. Connect wires to the power supply wiring terminals as shown in Figure 13, page 13.
5. Slide the retaining clip over the wiring, then tighten the screw to hold the clip in place. See Figure 1, page 2.
A user-supplied switch may be installed in the power supply line. For compliance with low-voltage directive 73/23/EEC (European installations), a switch in close proximity to the Model 3300/3500 is required.
12
Figure 13. Power supply wiring terminals
Ground lug for
power supply
Power supply
wiring terminals
DC power supply terminal designations
AC power supply terminal designations
13
©2003, Micro Motion, Inc. All rights reserved. P/N 3300994, Rev. C
*3300994*
Visit us on the Internet at www.micromotion.com
Micro Motion Inc. USA
Worldwide Headquarters
7070 Winchester Circle Boulder, Colorado 80301 T (303) 530-8400
(800) 522-6277
F (303) 530-8459
Micro Motion Europe
Emerson Process Management Wiltonstraat 30 3905 KW Veenendaal The Netherlands T +31 (0) 318 495 670 F +31 (0) 318 495 689
Micro Motion United Kingdom
Emerson Process Management Limited Horsfield Way Bredbury Industrial Estate Stockport SK6 2SU U.K. T 0800 966 180 F 0800 966 181
Micro Motion
TM
Micro Motion Asia
Emerson Process Management 1 Pandan Crescent Singapore 128461 Republic of Singapore T (65) 6777-8211 F (65) 6770-8003
Micro Motion Japan
Emerson Process Management Shinagawa NF Bldg. 5F 1-2-5, Higashi Shinagawa Shinagawa-ku Tokyo 140-0002 Japan T (81) 3 5769-6803 F (81) 3 5769-6843
Loading...