This manual provides an introduction to the Micro Motion
also provides a short description of the Modbus protocol and how it has been implemented by Micro
Motion.
Note: This manual does not address Modbus programming requirements and techniques in detail. For
Modbus programming specifications, see http://www.modbus.org.
This manual assumes that the programmer is already familiar with the Micro Motion transmitter at a
functional level. If required, obtain the appropriate transmitter manual and refer to it for information
on transmitter features and functions.
1.2About the Modbus Interface Tool
The Modbus Interface Tool is designed to provide the Modbus information required to configure, use,
and troubleshoot a Micro Motion transmitter via Modbus protocol. For example, for each transmitter,
the Modbus Interface Tool provides a list of all Modbus coils and registers supported by that
transmitter, with:
•Address, data type, and length information
®
Modbus® Interface Tool. This manual
Using the Modbus Interface Tool Modbus ProtocolBefore You Begin
•Read/write vs. read-only information
•Quick definitions
•Transmitter version information
•Hyperlinks to supplementary notes or procedures
•Hyperlinks to integer codes, if required
•Keywords
Using this information, plus information provided in the appropriate transmitter manual, the
programmer can use the Modbus interface to:
•Read process data
•Reset totalizers and inventories
•Run batches or fills
•Read alarm status and acknowledge alarms
•Read and interpret diagnostic data
1.2.1Transmitters included in the Modbus Interface Tool
Although most Micro Motion transmitters support Modbus protocol via the service port, the Modbus
Interface Tool includes only transmitters with dedicated Modbus/RS-485 terminals, as listed in
Tabl e 1-1 .
Getting Started Manual1
Before You Begin
Table 1-1Transmitters included in the Modbus Interface Tool
TransmitterModel number
MVD™ Direct Connect™ with the standard core processorElectronics interface code W, D, Y, or E in sensor model
code
™
MVD
Direct Connect™ with the enhanced core processorElectronics interface code 6 or 8 in sensor model code
RFT9739RFT9739*******
9739 MVD9739MVD********
Model 15001500**********
Model 1500 with the Filling and Dosing Application1500*******B**
Model 1700 with analog outputs1700***A******
Model 25002500**********
Model 2700 with analog outputs2700***A******
Model 5700 with configurable outputs5700*********
Model 5700 with Ethernet transmitters5700*********
LF-Series 5 2 mA/1 FO configurable multivariable DIN rail
mount
Series 3000 MVD (4-wire)3**0****5*****
Series 3000 NOC (9-wire)3**0****3***N*
Series 3000 MVD NOC (4-wire)3**0****5***N*
Filling Mass Transmitter (FMT)FMT**********
LFT5*******
3**0****5*******
3**0****6*****
3**0****6*******
3**0****3*****N*
3**0****5*****N*
3**0****6***N*
3**0****6*****N*
Note: MVD Direct Connect installations do not include a transmitter. However, a Modbus/RS-485
connection can be made to the core processor component, and Modbus commands can be used to
communicate with the core processor. See the MVD Direct Connect flowmeter installation manual for
information on setting up this connection.
2Micro Motion® Modbus® Interface Tool
Chapter 2
Using the Modbus Interface Tool
2.1About this chapter
This chapter provides basic instructions for using the Modbus Interface Tool.
Note: Instructions assume that you are using Excel 2007. If you are using another version of Excel,
adapt the instructions as required.
2.2Installing and running the Modbus Interface Tool
The Modbus Interface Tool is provided on an installation CD or in a self-extracting file that can be
downloaded from the Micro Motion web site.
To install the Modbus Interface Tool:
1. Insert the installation CD into the CD drive on your PC, or download the self-extracting file to
a convenient location on your PC.
2. Run the Setup file.
3. Follow the onscreen instructions.
Using the Modbus Interface Tool Modbus ProtocolBefore You Begin
The installation program will create a desktop shortcut for the Modbus Interface Tool. To start the
program, click the icon or click
2.3Macros and macro substitutes
In the Modbus Interface Tool, macros are used for the following functions:
•Selecting the transmitter you want to work with
•Resizing the window for your monitor
If macros are not enabled in your Excel installation, you will see an error message when you use the
Select buttons on the Welcome panel. Micro Motion recommends enabling macros for this
spreadsheet if possible. Use standard Excel techniques.
If you cannot enable Excel macros for the Modbus Interface tool:
•To select the transmitter you want to work with, click
desired view from the list. See Section 2.5 for more information.
•To resize the window for your monitor, use standard Windows controls.
2.4Modbus Interface Tool structure
The Modbus Interface Tool is organized as a set of worksheets within an Excel spreadsheet. Standard
Excel features are used to order and present the information, as described in the following sections.
Start>Programs>MMI>Modbus Interface Tool.
View>Custom Views and select the
Getting Started Manual5
Using the Modbus Interface Tool
You can use any Excel feature available on your system to make the Modbus Interface Tool more
convenient or customized for you. For example, using standard Excel methods, you can:
•Set up site-specific reports and printing instructions
•Change the sort order
•Change the Freeze Panes setting
•Show or hide different columns
The Modbus Interface Tool is not write-protected. You can save your custom version over the
installed spreadsheet or to a new file. If you save to a new file, be sure to update the desktop shortcut
appropriately or create a shortcut for your custom version.
2.5Selecting the transmitter
The Modbus Interface Tool assumes that you want to see Modbus information for only one transmitter
at a time. The Welcome worksheet provides a list of transmitters. Click the Select button for the
transmitter you are working with, and a custom view for that transmitter will be displayed.
To view information for a different transmitter, return to the Welcome worksheet and click the Select
button for the new transmitter.
To view information for all transmitters at once, return to the Welcome worksheet and click the Select
button for the “All Products” option.
2.6Using filters and keywords
The Modbus Interface Tool is shipped with filters enabled. Filters are an Excel feature that allow you
to view only rows that contain predefined data. For example:
•You can define a filter on the Used column to see only rows that are active for your transmitter.
•You can define a filter on the Keywords column to see only rows associated with the selected
keyword.
Use standard Excel methods to define and use filters.
2.7Using hyperlinks
The Modbus Interface Tool uses Excel hyperlinks to display supplementary information for each coil
and register. You can view this information as desired.
2.7.1Viewing the information at the hyperlink destination
If you want to see the information at the hyperlink destination, click the hyperlink.
To return to your original location after viewing the information, click the Back button. In Excel 2007,
the Back arrow is not on the ribbon. To use it, you must add it to the Quick Access Toolbar.
6Micro Motion® Modbus® Interface Tool
Using the Modbus Interface Tool
2.7.2Hyperlink Base
If you receive the following message when you click a hyperlink:
Cannot open the specified file
check that the Hyperlink Base is set correctly.
In a typical installation, the Hyperlink Base is blank, so that it defaults to the installation directory.
However, if you have moved the Modbus Interface Tool or changed directory or file names, you may
need to verify that the Hyperlink Base is blank, or update it manually. To do this in Excel 2007:
1. Click the Microsoft Office button, then click
2. In the Document Information Panel, click
select the Summary panel.
3. In the Hyperlink Base field, delete the contents or enter the name and location of the Modbus
Interface Tool on your PC.
4. Click
OK.
Prepare>Properties.
Document Properties>Advanced Properties, and
Using the Modbus Interface Tool Modbus ProtocolBefore You Begin
Getting Started Manual7
8Micro Motion® Modbus® Interface Tool
Chapter 3
Modbus Protocol on Micro Motion Transmitters
3.1About this chapter
This chapter provides an introduction to using Modbus protocol with Micro Motion transmitters.
Note: This is not a complete definition of the Modbus interface. For more information on
programming to the Modbus interface, see www.modbus.org.
3.2Modbus address
A Micro Motion transmitter emulates a programmable logic controller (PLC) that communicates with
a Modbus-compatible host controller in a multidrop network. Each transmitter has a unique Modbus
address. The host uses a non-zero polling address to initiate communication with a single transmitter,
or a polling address of 0 to broadcast a message to all network devices.
Using the Modbus Interface ToolModbus ProtocolBefore You Begin
3.3Transmitter registers and data types
The transmitter can accept, store, and return boolean values, integers, floating-point values, and
ASCII characters, regardless of the data transmission mode (7-bit ASCII or 8-bit RTU) used by the
host controller. The different data types are stored in different register types in transmitter memory.
Each register type has different requirements for reading or writing.
3.3.1Register addresses
Each register is identified by its address (or starting address), which is a 4-digit number.
Depending on the PLC that will be used to communicate with the transmitter, you may need to
subtract 1 from the address or starting address of the register. Refer to your PLC documentation to
know if this applies to you.
Example
3.3.2Register types
The register types are listed and briefly described in Table 3-1. More detailed descriptions are
provided following the table.
The Modbus Interface Tool specifies 42 as the address of the register
that contains the unit for process variables that measure volume flow.
Use 41 in the data field of the Modbus frame.
Note: Micro Motion terminology is a simplified version of Modbus terminology. The term “coil” is
used for both Modbus coils (read-write) and Modbus discrete inputs (read-only), and the term
“register” is used for both Modbus holding registers (read-write) and Modbus input registers
(read-only).
Getting Started Manual9
Modbus Protocol on Micro Motion Transmitters
Table 3-1Modbus register types
Register typeSizeData typeDescription
Coil1 bitBinaryBoolean (0 or 1, ON or OFF)
Float16 bitFloating-pointUsed in pairs to store 32-bit floating-point values in single
Integer16 bitIntegerUnsigned 16-bit integers ranging from 0 to 65535
Long integer16 bitIntegerUsed in pairs to store unsigned 32-bit integers ranging from 0 to
ASCII16 bit8-bit ASCIIOne or more consecutive registers. Each register stores two
precision IEEE 754 format
4294967295 (0xFFFFFFFF).
8-bit ASCII characters (16 bits total).
Coils
There are three types of coil:
•Read-only. These coils can be read through Modbus functions 1 or 2. Function 7, used with
RFT9739 transmitters, MVD Direct Connect systems, or other systems with Modbus wiring
direct to the core processor, will return the values of coils 21–28.
•Read-write “sticky” coils, i.e., coils that retain the value written to them. For example, totalizer
start/stop coils are sticky. These coils can be read through Modbus functions 1 or 2, and
written using Modbus function 5 (see Section 3.4.2).
•Read-write “momentary” coils, i.e., coils that initiate an action when written as ON, and
switch back to OFF either immediately or when the process is complete. For example, the coils
used to initiate calibration are momentary. These coils can be read through Modbus functions
1 or 2, and written using Modbus function 5 (see Section 3.4.2).
Modbus function 1 or 2 is used to read either a single coil or a group of consecutive coils. Each bit
within the data bytes represents a single coil, with lower addresses represented by lower-order bits
within the byte. If more than 8 coils are read, the first 8 will be read from the first byte, the next 8
from the next byte, and so on. The last data byte read may contain fewer than 8 coils, with the
high-order bit(s) set to 0. In each of these cases, 1 represents ON and 0 represents OFF.
Modbus function 5 is used to write a single coil (read-write coils only). The data value 65,280
(FF00 hex) sets the coil ON, and 0 turns the coil OFF.
Modbus function 15 is used to write a group of consecutive coils. In this case, each bit within the data
bytes represents a single coil, with lower addresses represented by lower-order bits within the byte. If
more than 8 coils are written, the first 8 coils will be written in the first byte, the next 8 coils in the
next byte, and so on. The last data byte transmitted may contain fewer than 8 coils, with the high
order bit(s) as don't care. In each of these cases a 1 turns the coil ON and a 0 turns the coil OFF.
Integer registers
Modbus function 3 or 4 (see Section 3.4.2) is used to read a single integer register or a group of
consecutive integer registers. If the registers are non-consecutive, a separate command must be used
for each register.
Note: To read several non-consecutive registers with a single command, use slot addresses. See Micro
Motion Modbus Interface Tool Slots and Slot Address Sequences.
Modbus function 6 is used to write a single integer register (read-write registers only). Modbus
function 16 is used to write a group of consecutive integer registers (see Section 3.4.2).
10Micro Motion® Modbus® Interface Tool
Modbus Protocol on Micro Motion Transmitters
S1M 2
E127–
Integers are transmitted high-order byte first. If multiple registers are read or written in a single
command, data are transmitted from consecutive registers, beginning with the register that has the
lowest address.
Long integer registers
Some integer values used by the transmitter are larger than 65,535, which is the largest number that
can be stored in a single integer register. In these cases, the value is stored in two consecutive integer
registers. These “long integer” registers are read and written using the Modbus functions 3, 4, and 16
(see Section 3.4.2). The most significant word is stored in the lower register, and the least significant
word is stored in the higher register.
When reading and writing long integer values, partial numbers are not permitted by the transmitter.
Because of this, long integer values must be written using command 16 (see Section 3.4.2).
Float registers
Register pairs are used to store single-precision IEEE 754 floating-point values. A register pair
consists of two consecutive 16-bit registers.
When reading and writing floating-point data, partial numbers are not permitted by the transmitter.
Because of this, floating-point data must be written using command 16 (see Section 3.4.2). Byte order
is configurable (as discussed later in this section).
Float register pairs are read using a single command. Multiple values can be read with a single
command, if the register pairs are consecutive. If they are non-consecutive, a separate command must
be used for each register pair.
Using the Modbus Interface ToolModbus ProtocolBefore You Begin
Note: To read several non-consecutive register pairs with a single command, use slot addresses. See
Micro Motion Modbus Interface Tool Slots and Slot Address Sequences.
Data is written to the register pair using a single command. Multiple values can be written with a
single command, if the register pairs are consecutive. If they are non-consecutive, a separate
command must be used for each register pair.
Each floating-point value contains four bytes. Each byte always has the same contents, independent of
the byte order. Byte contents are shown below:
Byte #0Byte #1Byte #2Byte #3
S E E E E E E EE M M M M M M MM M M M M M M MM M M M M M M M
where:
•S = sign of the mantissa
-0 = positive
-1 = negative
•E = exponent, biased by 127 (e.g., a value of 200 indicates an exponent of 73)
•M = mantissa, 23 least significant bits, fractional portion
The value of the floating-point number is constructed as shown below. The 24-bit mantissa is
composed of an assumed most significant bit of 1, a decimal point following the 1, and the 23 bits of
the mantissa:
Getting Started Manual11
Modbus Protocol on Micro Motion Transmitters
Invalid data, such as bad process variable, are represented by the hexadecimal (not a number) value
for your transmitter:
•RFT9739 transmitters:
00 00 7F A0
•MVD transmitters: 7F A0 00 00
The RFT9739 transmitter must receive and send floating-point data in the following byte order:
2–3 0–1
MVD transmitters can receive and send floating-point data in the following byte orders:
0–1 2–3
2–3 0–1 (default)
1–0 3–2
3–2 1–0
ASCII registers
Modbus functions 3, 4, 6, and 16 are used to read and write ASCII registers (see Section 3.4.2). String
values are padded to 4, 8, 16, or 32 characters. The space character is used to pad data read from the
transmitter, and don’t care is used to pad data sent to the transmitter.
When reading or writing ASCII registers, the first register must always be read or written. You can
read or write the first register, the first two registers, the first three registers, and so on. The registers
must be read or written with one command. More than one character string can be read or written in a
single command, if the ASCII registers are consecutive.
Note: To read several non-consecutive ASCII register sets with a single command, use slot addresses.
See Micro Motion Modbus Interface Tool Slots and Slot Address Sequences.
3.4Message framing
Modbus messages are structured in frames. In general, each frame contains an address field, a
function field, a data function field, and an error check field. Frames are structured and transmitted
differently depending on the data transmission mode (see Section 3.5).
There are three frame types:
•Query frames are used to address a single network device. The network device responds with a
response frame. The combination of one query frame and one response frame is called a
query/response message.
•Broadcast frames are used to address all devices on the network. The devices do not respond.
Each broadcast frame constitutes one broadcast message. Any frame with a value of 0 in the
address field is a broadcast frame.
Only Modbus function codes 5, 6, 8, 15, and 16 are valid in a broadcast message. Every slave
device on a multidrop network will receive a broadcast message and perform the requested
action, and no slave will respond, which is why no read functions are supported in a broadcast
message.
Because of its use in broadcast messages, address 0 is not useful as a Modbus polling address.
12Micro Motion® Modbus® Interface Tool
Modbus Protocol on Micro Motion Transmitters
3.4.1Address field
In a query frame, the address field contains a transmitter's polling address.
In a response frame, the address field contains the polling address of the responding device.
In a broadcast frame, the address field contains a 0, which tells the network devices not to reply.
3.4.2Function field
The function field contains a Modbus function code. Micro Motion’s Modbus interface uses a subset
of function codes supported by all Modbus hosts. The function codes used by Micro Motion’s
Modbus interface are listed and defined in Table 3-2
In Table 3-2:
•Functions 01 and 02 as used by Micro Motion perform the same processing, and are
interchangeable.
•Functions 03 and 04 as used by Micro Motion perform the same processing, and are
interchangeable.
In a query frame or broadcast frame, the function code specifies a read command, write command, or
diagnostic command to be applied to the register specified in the data field.
In a response frame, the function code is used to verify the device's response to the command:
.
Using the Modbus Interface ToolModbus ProtocolBefore You Begin
•If no error occurred, the transmitter echoes the original function code. The data field contains
the start register and the value sent, or the start register and the function number. See
Section 3.4.3.
•If an error occurred, the most significant bit in the function field is set. The data field contains
an exception response explaining any errors encountered processing the command.
Table 3-2Function code definitions
Function
code
01
02
03
04
05WriteSet coil• Set coil to a specified ON or OFF state
06WriteLoad register• Write an integer value to an integer register
(1)
07
(1)
08
Command
typeDescriptionExplanation
ReadRead coil status• Read status of one coil or consecutive coils
ReadRead integer, float,
or ASCII registers
DiagnosticRead exception
status
DiagnosticLoopback diagnostic• Send test message to transmitter to evaluate communication
• Read integer values in one holding register or consecutive holding
registers
• Read floating-point values in one register pair or consecutive
register pairs
• Read character strings in consecutive ASCII registers
Read ON/OFF status of status bits that comprise the high-order byte
of register 0125. Micro Motion has programmed these bits to indicate
flowmeter status. They include:
• Bit #0(E)EPROM checksum failure
• Bit #1RAM diagnostic failure
• Bit #2Sensor failure
• Bit #3Temperature sensor failure
• Bit #4Input overrange
• Bit #5Frequency overrange
• Bit #6Transmitter not configured
• Bit #7Real-time interrupt failure
processing
Getting Started Manual13
Modbus Protocol on Micro Motion Transmitters
Table 3-2Function code definitions
Function
code
15WriteSet multiple coils• Set consecutive coils to an ON or OFF state
16WriteLoad multiple
(1)
17
(1) Supported only by RFT9739 transmitters, MVD Direct Connect systems, and other systems only if the Modbus wiring is direct to the
core processor.
Command
typeDescriptionExplanation
registers
ReadReport device I.D.• Report AA
• Write integer values to consecutive holding registers
• Write a single-write multiple-character string to one ASCII register
set (four to eight consecutive ASCII registers)
device type and ON operating status
hex
3.4.3Data field
A data field can contain values, addresses, limits, or exception responses:
•In a query or broadcast frame, the data field contains information that is needed by the
transmitter to perform the command issued in the function field. For example, the data field
might contain the starting address of the first register to read and the number of registers to
read.
•In a response frame, the data field contains either data collected by the transmitter or an
exception response.
The function code in the function field determines the structure of the data field. Many Modbus
functions require sending the data start address and/or the number of bits in the data field. Each value
is transmitted in two bytes, high-order byte first, so that if both the data start address and the number
of bits are transmitted, four bytes are required.
The following illustrations show the structure of the data field, in both query and response frames, for
each supported function code.
Function codes 01 and 02
Query
Response
(1) Byte count is the number of bytes in the coil status byte(s) field.
AddressFunctionStarting coil# of coilsError check
01 or 02
AddressFunctionByte count
01 or 02/..../
(1)
Coil status byte(s)Error check
14Micro Motion® Modbus® Interface Tool
Modbus Protocol on Micro Motion Transmitters
Function codes 03 and 04
Query
Response
AddressFunctionStarting register# of registersError check
03 or 04
AddressFunctionByte count
03 or 04/..../
(1)
Register data byte(s)Error check
(1) Byte count is the number of bytes in the register data byte(s) field.
Address FunctionStarting coil# of coilsError check
15
(1) Byte count is the number of bytes in the coil data byte(s) field.
Function code 16
Address FunctionStarting register# of registersByte count
Query
16/..../
Address FunctionStarting register# of registersError check
Response
16
(1) Byte count is the number of bytes in the register data byte(s) field.
Function code 17
Address Function Error check
Query
17
(1)
Register data byte(s)Error check
(1)
Response
Address Function Byte count
17
Slave IDRun indicator status Error check
(1) Byte count is the number of bytes in the slave ID and run indicator status fields. Each field contains
one byte, so byte count is always 2.
If a device detects errors while executing a command issued in a query, the most significant bit in the
response function field is set, and the data field contains an exception response that explains why the
device cannot execute the command.
Table 3-3 lists and describes all Modbus exception responses used by the Micro Motion Modbus
interface.
Table 3-3Exception response definitions
Exception
responseDescriptionExplanation
01Illegal functionThe received message function is not an allowable action for the transmitter
16Micro Motion® Modbus® Interface Tool
Modbus Protocol on Micro Motion Transmitters
Table 3-3Exception response definitions
Exception
responseDescriptionExplanation
02Illegal data addressThe address referenced in the data field is not an allowable address for the location
03Illegal data valueThe value referenced in the data field is not allowed in the addressed location
06Busy, rejected
message
This message displays if you read the middle of — or a single register of — a
floating point, long integer, or ASCII register that requires two or more registers to
read.
The device received the message without error, but is engaged in processing a
long-duration program command
3.4.4Error check field
The error check field allows the Modbus host and other network devices to check a message for data
transmission errors. Electrical noise or other interference can cause a message to change during
transmission from one unit to another unit in the network. Error checking ensures that the host or
other network device does not react to messages that have changed during data transmission. See
Section 3.6 for more information on error checking.
3.5Data transmission modes
Modbus protocol uses either ASCII (7-bit) or RTU (8-bit) data transmission modes. In RTU mode,
messages consist of 8-bit binary characters, while in ASCII mode a message consists of 7-bit ASCII
characters. To obtain the ASCII mode representation of a message, each 8-bit RTU character is
divided into two 4-bit parts: a high order part and a low order part. Each of these 4-bit parts is then
converted to its hexadecimal equivalent, and the 7-bit ASCII codes corresponding to the hexadecimal
numbers are transmitted. ASCII mode requires approximately twice as many characters as RTU mode
because a single 8-bit RTU character equals two 7-bit ASCII characters.
Modbus protocol also has several levels of error checking, including automatic redundancy checks.
The data transmission mode determines the form of the redundancy checks: ASCII mode relies on
Longitudinal Redundancy Checks (LRC); RTU mode relies on Cyclic Redundancy Checks (CRC).
Table 3-4 summarizes these differences.
Table 3-4Comparison of ASCII and RTU data transmission modes
Using the Modbus Interface ToolModbus ProtocolBefore You Begin
Characteristics of modeASCII (7-bit)RTU (8-bit)
Coding systemHexadecimal
Start bits
Data bits (least significant first)
Optional parity bits (in data field only)
Stop bits
Error checkingLRC (Longitudinal Redundancy
(ASCII printable characters 0-9, A-F)
1
7
1 for odd or even parity
1 or 2
Checks)
8-bit binary
1
8
1 for odd or even parity
1 or 2
CRC (Cyclic Redundancy Checks)
3.5.1Message framing in ASCII mode
In ASCII mode, each frame has a start delimiter, an address field, a function field, a data field, an
error check field, and an end delimiter.
Getting Started Manual17
Modbus Protocol on Micro Motion Transmitters
The colon character (:) is the start delimiter, and the carriage return–line feed (CRLF) characters are
the end delimiter. The line feed also serves as a synchronizing character, which indicates that the
transmitting station is ready to receive an immediate response.
ASCII mode allows breaks of up to one second in duration to occur between characters.
Address fields, function fields, and error check fields can contain two ASCII hexadecimal characters
or 16 bits. The data field contains a multiple of two ASCII characters or a multiple of 16 bits. An
ASCII character has 1 start bit, 7 data bits, and 1 or 2 stop bits. If parity is used, the data field has a
single parity bit. Table 3-5 illustrates an ASCII frame.
Table 3-5ASCII message frame format
Beginning
of frame
:2 characters2 charactersn x 4 characters2 charactersCarriage
:16 bits16 bitsn x 16 bits16 bitsCarriage
Address
field
Function
field
Data
field
2-character format
6-bit format
Error check
field
3.5.2Message framing in RTU mode
In RTU mode, each frame has an address field, a function field, a data field, and an error check field.
Messages are transmitted as a continuous stream of binary characters.
Messages are terminated when no characters are sent in the time required to transmit 3½ characters.
This 3½-character gap delimits each query or response message and synchronizes Modbus RTU
communications.
The receiving device monitors the elapsed time between receipt of characters. If the time gap between
characters in a frame exceeds the time required to receive 3½ characters, the receiving device flushes
the frame and assumes that the next byte received will be a polling address.
Address fields and function fields each contain one RTU character. Data fields can contain 0, 1, or
more RTU characters. Error check fields contain 2 RTU characters. An RTU character has 1 start bit,
8 binary data bits, and 1 or 2 stop bits. If parity is used, the data field has a single parity bit. Table 3-6
illustrates an RTU frame.
End of
frame
return
return
Ready-to-
receive response
Line feed
Line feed
Table 3-6RTU message frame format
Elapsed
time
Maximum time is
time needed to
send 3½ characters
Address
field
(8 bits)
1 character
Function
field
(8 bits)
1 character
Data
field
(8 bits + optional parity
bit) n x 1 character
Error check
field
(2 x 8 bits)
2 characters
Elapsed
time
Maximum time is
time needed to
send 3½ characters
3.6Error checking
Modbus communications automatically performs two levels of error checking:
•Parity checking
•Redundancy checking
18Micro Motion® Modbus® Interface Tool
Modbus Protocol on Micro Motion Transmitters
3.6.1Parity checking
Note: Parity checking is performed only if even or odd parity is configured. If no parity is configured,
an additional stop bit is transmitted to fill out the character frame.
If even or odd parity is configured, the Modbus sender includes a parity bit with each character sent.
The parity bit is determined as follows:
•The number of ones in the data field of the character is counted.
•The number of ones is determined to be even or odd.
If Modbus communications is configured for even parity, the sender sets the parity bit as required so
that the data field of the character contains an even number of ones. If Modbus communications is
configured for odd parity, the system sets the parity bit as required so that the data field of the
character contains an odd number of ones.
For example, using even parity:
•The value 0110 1000 requires a parity bit of 1.
•The value 0110 1010 requires a parity bit of 0.
The Modbus receiver performs the same calculation and verifies that the parity bit is correct. If the
parity bit is not correct, a transmission error is assumed.
However, if a message contains two errors, parity sometimes cannot detect the changes. For example,
if data transmission distorts 0010 0000 to 0010 0011, the value still will have an odd number of ones
and the parity bit will be correct. For this reason, Modbus communications performs redundancy
checks to detect multibit errors in which the data has not changed.
Using the Modbus Interface ToolModbus ProtocolBefore You Begin
•In ASCII mode, the system automatically performs Longitudinal Redundancy Checks (LRC).
•In RTU mode, the system automatically performs Cyclic Redundancy Checks (CRC-16).
In ASCII mode, the error check is an 8-bit binary number represented as two ASCII hexadecimal
characters. The sender divides the hexadecimal characters into 4-bit high-order and 4-bit low-order
binary parts, adds the binary characters without wraparound carry, derives a ones complement of the
sum, and then adds 1, thereby deriving a twos complement.
In calculating the LRC, the Modbus system ignores the colon (:) that begins the frame, the carriage
return and line feed that end the frame, and all non-ASCII hexadecimal characters.
Getting Started Manual19
Modbus Protocol on Micro Motion Transmitters
Example
LRC produced by a host that sends a query to transmitter 02, asking it
to read the first 8 logic coils:
Address
Function code
Start add high order part
Start add low order part
Quantity of parts
Read first 8 coils
2
0
1
0
0
0
0
0
0
0
8
0
00000010
00000001
00000000
00000000
00000000
00001000
—————
00001011
Ones complement
+1
11110100
00000001
—————
Two s c o m p l e m e nt
11110101
Error checkF5F 5
The transmitter adds all received data bytes, including the LRC:
Error checkF5F 5
Address
Function code
Start add high order part
Start add low order part
Quantity of parts
2
0
1
0
0
0
0
0
0
0
Read first 8 coils OK
Error check
00000010
00000001
00000000
00000000
00000000
00001000
11110101
—————
SUM
00000000
The 8-bit values should all equal zero. The sum can exceed 8 bits, but
only the low-order bits should be saved.
20Micro Motion® Modbus® Interface Tool
Modbus Protocol on Micro Motion Transmitters
3.6.3Cyclic redundancy check (RTU mode)
In RTU mode, the Modbus system follows these steps to implement the CRC-16 sequence:
1. The sender regards the message as one continuous binary number with its most significant bit (MSB) transmitted first. (The sender regards the message as data bits only, while disregarding
start/stop bits and optional parity bits.)
2. The sender pre-multiplies X16 by the continuous binary number (shifts it left 16 bits), then
divides the resulting product by the polynomial X16 + X15 + X2 + 1 expressed as the binary
number 1100 0000 0000 0101.
3. The sender ignores the integer quotient digits, then appends the 16-bit remainder to the
message (MSB first) as the 2 CRC check bytes. (The 16-bit remainder is first initialized to all
ones to prevent acceptance of all zeros as a message.)
4. If no errors have occurred, the received message (including the CRC) will leave a remainder of
0 when divided by the polynomial X16 + X15 + X2 + 1. (The receiver recalculates the CRC
and compares it to the transmitted CRC.)
All arithmetic is performed without carries. The device that serializes the data for transmission sends the conventional least significant bit (LSB) or farthest-right bit of each character first. In generating
the CRC, the first transmitted bit represents the MSB of the dividend. So, since the arithmetic is
performed without carries, assume the MSB is farthest right during computation of the CRC, and the
bit order of the generating polynomial is reversed. The MSB of the polynomial is dropped, because it
affects the quotient but not the remainder. This yields 1010 0000 0000 0001 (hex A001). Reversing
the bit order does not affect the interpretation of the bit order of characters external to the CRC
calculations.
Using the Modbus Interface ToolModbus ProtocolBefore You Begin
Given these assumptions, the following example illustrates a CRC-16 error check for a read exception
status query (function code 07) sent to transmitter 02, with the check bytes formed according to this
step-by-step procedure:
1. Load a 16-bit register with all ones.
2. XOR the first 8-byte with the low order byte of the 16-bit register.
3. Shift the 16-bit register 1 bit to the right.
4. If the flag (the bit shifted out to the right) is a 1, XOR the generating polynomial 1010 0000
0000 0001 with the 16-bit register.
5. If the flag is a 0, again shift the register one bit to the right.
6. Repeat Step 3 until 8 shifts have been performed.
7. XOR the next 8-byte with the low order byte of the 16-bit register.
8. Repeat Steps 3 through 6 until all message bytes have been exclusive OR'ed with the
generating polynomial and then shifted eight times.
9. The 16-bit register contains the 2-byte CRC error check. The error check is added to the
message, least significant bytes first.
Table 3-7 illustrates this step-by-step procedure.
Getting Started Manual21
Modbus Protocol on Micro Motion Transmitters
Table 3-7Example CRC (read exception status from slave 02)
Step16-bit registerFlag
Load 16-bit register with all ones1111111111111111
Message byte: Address 0200000010
Address 02 XOR high order byte of 16-bit register1111111111111101
Shift 101111111111111101
Generating polynomial1010000000000001
Generating polynomial XOR shift 11101111111111111
Shift 201101111111111111
Generating polynomial1010000000000001
Generating polynomial XOR shift 21100111111111110
Shift 301100111111111110
Shift 400110011111111111
Generating polynomial1010000000000001
Generating polynomial XOR shift 41001001111111110
Shift 501001001111111110
Shift 600100100111111111
Generating polynomial1010000000000001
Generating polynomial XOR shift 61000010011111110
Shift 701000010011111110
Shift 800100001001111111
Generating polynomial1010000000000001
Generating polynomial XOR shift 81000000100111110
Message byte: Function code 07 (read exception status)00000111
Function code 07 XOR high order byte of 16-bit register1000000100111001
Shift 101000000100111001
Generating polynomial1010000000000001
Generating polynomial XOR shift 11110000010011101
Shift 201110000010011101
Generating polynomial1010000000000001
Generating polynomial XOR shift 21101000001001111
Shift 301101000001001111
Generating polynomial1010000000000001
Generating polynomial XOR shift 31100100000100110
Shift 401100100000100110
Shift 500110010000010011
Generating polynomial1010000000000001
Generating polynomial XOR shift 51001001000001000
Shift 601001001000001000
Shift 700100100100000100
Shift 800010010010000010
Result1241
22Micro Motion® Modbus® Interface Tool
Modbus Protocol on Micro Motion Transmitters
Add the 16-bit register, with its most significant bits first, to the message. So the error check field now
contains the last 16-bit register as the two 8-bit characters 0001 0010 (hex 12) and 0100 0001
(hex 41). The transmitted message, including the CRC-16 and shifted to the right, looks like
Tabl e 3-8 .
Table 3-8Result of example CRC
Address fieldFunction fieldError check field
Hex 02Hex 07Hex 41Hex 12
0000 00100000 01110100 00010001 0010
Using the Modbus Interface ToolModbus ProtocolBefore You Begin
Getting Started Manual23
24Micro Motion® Modbus® Interface Tool
Micro Motion Inc. USA
Worldwide Headquarters
7070 Winchester Circle
Boulder, Colorado 80301
T +1 303-527-5200
T +1 800-522-6277
F +1 303-530-8459
www.micromotion.com
Micro Motion Europe
Emerson Automation Solutions
Neonstraat 1
6718 WX Ede
The Netherlands
T +31 (0) 704136666
F +31 (0) 318 495 556
www.micromotion.nl
*MMI-20011275*
MMI-20011275
Rev. AC
2016
Micro Motion Asia
Emerson Automation Solutions
1 Pandan Crescent
Singapore 128461
Republic of Singapore
T +65 6777-8211
F +65 6770-8003
Micro Motion United Kingdom
Emerson Automation Solutions
Emerson Process Management Limited
Horsfield Way
Bredbury Industrial Estate
Stockport SK6 2SU U.K.
T +44 0870 240 1978
F +44 0800 966 181
Micro Motion Japan
Emerson Automation Solutions
1-2-5, Higashi Shinagawa
Shinagawa-ku
Tokyo 140-0002 Japan
T +81 3 5769-6803
F +81 3 5769-6844
The Emerson logo is a trademark and service mark of Emerson
Electric Co. Micro Motion, ELITE, ProLink, MVD and MVD Direct
Connect marks are marks of one of the Emerson Automation
Solutions family of companies. All other marks are property of their
respective owners.