Micro Motion Manual: Power Supply Wiring for the D600 Sensor | Micro Motion Manuals & Guides

Power-Supply Wiring for the D600 Sensor
Install drip leg in cable or conduit
Power-supply voltage must match voltage indicated on label
• Terminal 1 is line
• Terminal 2 is neu tral
• Terminal 3 is ground
Earth ground
115 V L N 5 A fuse 230 V L1 L2 3 A fuse
• A switch may be instal led in the power-supply line. For
CAUTION
Improper installation of wiring could cause measurement error or sensor failure.
• Shut off power before installing power-supply wiring.
• For person al and syst em saf ety, fo llow all i nstructions t o ensure sensor will operate correctly.
• Match power-supply voltage with voltage indicated on the label inside the amplifier housing.
compliance with low-voltage directive 73/23/EEC, a switch is required.
• Do not install power-supply wiring in the same cable tray or conduit as flowmeter cable.
• If conduit is used, connect a ½-inch NPT male conduit connector to the conduit opening in the seal for power­supply wiring. See
Figure 1
.
• If conduit is not used, connect a ½-inch NPT male cable gland to the conduit opening in the seal for power-supply wiring. See
To install flowmeter cable
Figure 1
.
, see the cable p reparation
instructions that are shipped with the cable preparation kit.
CAUTION
Failure to seal amplifie r housing cou ld cause a short circuit, which would result in measurement error or flowmeter failure.
To avoid risk of condensation or excessive moisture entering the amplifier housing:
• Seal all conduit openin gs.
• Install drip legs in cable or conduit.
• Fully tighten amplifier housing cover.
• Micro Motion D600 sensors comply with EMC directive 89/336/EEC and low-voltage directive 73/23/EEC, when properly installed in accordance with these instructions.
• Terminal 1 is line, terminal 2 is neutral, and terminal 3 is ground. See
Figure 1
• Ground the sensor with a maximum impedance of 1 ohm. Connect and bond a user-s up pli ed g round wire to the earth ground connection on the amplifier housing. See
.
Figure 1
Figure 1. D600 power-supply terminals
.
Visit us on the Internet at www.micromotion.com
Micro Motion Inc. USA
7070 Winchester Circle Boulder, Colorado 80301 Tel (303) 530-8400