Micro Motion Installation Manual: Model 3500 Transmitter 9-wire or Model 3300 Peripheral for Panel-Mount | Micro Motion Manuals & Guides

Quick Reference Guide
Model 3500 Transmitter (9-wire) or Model 3300 Peripheral
Installation Instructions for Panel-Mount
For online technical support, use the EXPERT2™ system at www.expert2.com. To speak to a customer service
representative, call the support center nearest you:
In the U.S.A., phone 1-800-522-MASS (1-800-522-6277)
In Canada and Latin America, phone (303) 530-8400
In Asia, phone (65) 6770-8155
In the U.K., phone 0800 - 966 180 (toll-free)
Outside the U.K., phone +31 (0) 318 495 67
Micro Motion
TM
BEFORE YOU BEGIN
This quick reference guide explains basic installation guidelines for
®
mounting the Micro Motion
Model 3300/3500 applications platform in a
panel cutout.
For information on I.S. applications, refer to Micro Motion ATEX, UL, or CSA installation instructions.
For complete instructions about configuration, maintenance, and service, refer to the instruction manual shipped with the transmitter.
WARNING
Improper installation in a hazardous area can cause an explosion.
For information about hazardous applications, refer to Micro Motion ATEX, UL, or CSA installation instructions, shipped with the transmitter or available from the Micro Motion web site.
WARNING
Hazardous voltage can cause severe injury or death.
Install transmitter and complete all wiring before supplying power.
CAUTION
Improper installation could cause measurement error or flowmeter failure.
Follow all instructions to ensure transmitter will operate correctly.
©2003, Micro Motion, Inc. All rights reserved. Micro Motion is a registered trademark of Micro Motion, Inc. The Micro Motion and Emerson logos are trademarks of Emerson Electric Co. All other trademarks are property of their respective owners.
1
European installations
This Micro Motion product complies with all applicable European directives when properly installed in accordance with the instructions in this quick reference guide. Refer to the EC declaration of conformity for directives that apply to this product.
The EC declaration of conformity, with all applicable European directives, and the complete ATEX Installation Drawings and Instructions are available on the internet at www.micromotion.com/atex or through your local Micro Motion support center.
Installation kit
The installation kit includes a bezel, frame, two mounting brackets with screws, a power supply wiring connector, and a retaining clip assembly for power supply wiring (see Figure 1).
The applications platform fits through a 5 7/16-inch (138 mm) square cutout in a panel that is 5/64 inch (2 mm) to 1/2 inch (13 mm) thick. The bezel provides a IP65 watertight seal between the panel cutout and the applications platform housing.
In addition, the installation kit includes:
A bracketed wiring connector for screw-type connectors (see Figure 5, page 5), or
I/O cables and connectors (see Figure 7, page 7)
Figure 1. Panel-mount installation kit
Frame
Power supply
wiring connector
Retaining-clip
assembly for
power supply wiring
2 x Mounting bracket
with screw
2
Panel thickness:
• 5/64 inch (2 mm) minimum
• 1/2 inch (13 mm) maximum
Bezel
STEP 1. Choosing a location
Choose a location for the transmitter based on the requirements described below.
Environmental requirements
Install the transmitter where ambient temperature is between
4 and
+140 °F (–20 and +60 °C).
Dimensions
If the Model 3300/3500 has screw-type wiring connectors, see Figure 2 for dimensions. If the Model 3300/3500 has I/O cables, see Figure 3, page 4, for dimensions. (See Figures 5 and 7, pages 5 and 7, for illustrations of screw-type connectors versus I/O cables.)
Figure 2. Panel-mount dimensions – screw-type connectors
inches
(mm)
Bezel
6 1/2 (165)
6
(152)
Panel
8 1/2 (216)
Fram e
7 7/8 (200)
4 1/2 (115)
6 11/16
(170)
6
(152)
Approvals
tag
1/2
(12)
Intrinsic safety shield
(Model 3500 only)
3
Figure 3. Panel-mount dimensions – I/O cables
inches
(mm)
6 1/2 (165)
Bezel
6
(152)
6
(152)
Panel
1/2
(12)
Fram e
8 3/4 (222)
Approvals
tag
5 5/16
(135)
6 11/16
(170)
Minimum 4 1/4"
(108 mm) bend radius
Flowmeter cable lengths
Maximum cable length from the sensor to the Model 3500 transmitter is 1000 feet (300 meters).
If you are installing the Model 3300 applications peripheral in combination with a transmitter, the maximum cable length from the transmitter’s frequency output to the Model 3300’s frequency input is 500 feet (150 meters).
STEP 2. Installing the Model 3300/3500 in the panel
Refer to Figure 4, page 5, and follow these steps:
1. Insert the Model 3300/3500 through the cutout.
2. Slide the frame over the housing.
3. Insert the posts on the brackets into the rails on the housing.
4. Tighten the screws evenly to 10 to 14 inch-pounds (1,13 to 1,38 Nm) to ensure a watertight seal between the gasket and the panel.