Micro Motion Installation Instructions: 3500 MVD Rackmount Installation Instruction | Micro Motion Manuals & Guides

Installation Manual
20000993, Rev BA
February 2015
Micro Motion® Model 3500 Transmitter (MVD) or Model 3300 Peripheral
Installation manual for rack mount
This Micro Motion product complies with all applicable European directives when properly installed in accordance with the instructions in this manual. Refer to the EC declaration of conformity for directives that apply to this product. The EC declaration of conformity, with all applicable European directives, and the complete ATEX Installation Drawings and Instructions are available on the internet at www.micromotion.com or through your local Micro Motion support center.
Information affixed to equipment that complies with the Pressure Equipment Directive can be found on the internet at
www.micromotion.com/documentation.
For hazardous installations in Europe, refer to standard EN 60079-14 if national standards do not apply.
Other information
Full product specifications can be found in the product data sheet. Troubleshooting information can be found in the transmitter configuration manual. Product data sheets and manuals are available from the Micro Motion web site at www.micromotion.com/
documentation.
Return policy
Micro Motion procedures must be followed when returning equipment. These procedures ensure legal compliance with government transportation agencies and help provide a safe working environment for Micro Motion employees. Failure to follow Micro Motion procedures will result in your equipment being refused delivery.
Information on return procedures and forms is available on our web support system at www.micromotion.com, or by phoning the Micro Motion Customer Service department.
Micro Motion customer service
Email:
Worldwide: flow.support@emerson.com
Asia-Pacific: APflow.support@emerson.com
Telephone:
North and South America Europe and Middle East Asia Pacific
United States 800-522-6277 U.K. 0870 240 1978 Australia 800 158 727
Canada +1 303-527-5200 The Netherlands +31 (0) 704 136 666 New Zealand 099 128 804
Mexico +41 (0) 41 7686 111 France 0800917901 India 800 440 1468
Argentina +54 11 4837 7000 Germany 0800 182 5347 Pakistan 888 550 2682
Brazil +55 15 3413 8000 Italy 8008 77334 China +86 21 2892 9000
Venezuela +58 26 1731 3446 Central & Eastern +41 (0) 41 7686 111 Japan +81 3 5769 6803
Russia/CIS +7 495 981 9811 South Korea +82 2 3438 4600
Egypt 0800 000 0015 Singapore +65 6 777 8211
Oman 800 70101 Thailand 001 800 441 6426
Qatar 431 0044 Malaysia 800 814 008
Kuwait 663 299 01
South Africa 800 991 390
Saudia Arabia 800 844 9564
UAE 800 0444 0684
Contents
Contents
Chapter 1 Planning....................................................................................................................... 5
1.1 Installation kit ........................................................................................................................ 5
1.2 Choose a location................................................................................................................... 6
1.3 Cable lengths ......................................................................................................................... 7
1.4 Install guide rails and wiring connectors................................................................................. 9
1.5 Install the Model 3500 or Model 3300 in the rack ................................................................... 10
Chapter 2 Mounting..................................................................................................................... 11
2.1 Mount the core processor ...................................................................................................... 11
Chapter 3 Wiring ......................................................................................................................... 13
3.1 Connect input and output wiring ........................................................................................... 13
3.2 Connect the Model 3500 to the sensor .................................................................................. 13
3.3 Wire the sensor to the remote core processor........................................................................ 19
3.4 Connect the power supply wiring........................................................................................... 21
Installation Manual 3

1 Planning

Planning
This installation manual explains basic installation guidelines for mounting the Micro Motion rack.
For information on I.S. applications, refer to Micro Motion approval documentation. For complete instructions about configuration, maintenance, and service, refer to the
instruction manual shipped with the transmitter.
Improper installation in a hazardous area can cause an explosion.
For information about hazardous applications, refer to the appropriate Micro Motion approval documentation, shipped with the meter or available from the Micro Motion web site.
Hazardous voltage can cause severe injury or death.
Install transmitter and complete all wiring before supplying power.
Improper installation can cause measurement error or meter failure.
Follow all instructions.
®
Model 3300 or Model 3500 MVD applications platform in a 19-inch (486,2 mm)
WARNING!
WARNING!
CAUTION!

1.1 Installation kit

For mounting in a rack, the Model 3300 or Model 3500 installation kit includes the following parts:
One DIN 41612/IEC 60603-2, Type D connector for input/output wiring, with solder
tails (Model 3300 only) or screw terminals
(Model 3500 only) One DIN 41612/IEC 60603-2, keyed Type D connector for sensor
wiring with screw terminals
One plug-in connector for power supply wiring
Four Model 3300 or six Model 3500 slotted cheese-head machine screws, size M2.5x8,
for securing wiring connectors to the rack
Installation Manual 5
Planning
1 U = 1 HE = 1.750 inches (44,5 mm)
3 U (3 HE)
3 U (3 HE)
3 U (3 HE)
1 U (1 HE)
1 U (1 HE)

1.2 Choose a location

Choose a location for the transmitter based on the requirements described below.
1.2.1 Environmental requirements
Install the transmitter where ambient temperature is between –4 and +140 °F (–20 and +60 °C).
If multiple applications platforms are installed, provide at least 1 U (1 HE) of vertical space between racks to ensure proper ventilation. See Figure 1-1.
Figure 1-1: Space requirements for proper ventilation
1.2.2 Dimensions
6 Model 3500 Transmitters or Model 3300 Peripherals - Rack Mount
The Model 3300 or Model 3500 has the following dimensions. See Figure 1-2:
Height: 128 mm (3 U or 3 HE)
Width: 142 mm (28 HP or 28 TE)
Depth: 160 mm
The Model 3300 or Model 3500 conforms to DIN standard EN 60297-3-101 (IEC 60297-3-101) for 19-inch (486,2 mm) racks. Up to three enclosures fit into one rack. See
Figure 1-1.
Figure 1-2: Dimensions for mounting in rack
25 HP
(25 TE)
3 U
(3 HE)
4 13/16 (122,5)
5 1/16
(128,5)
4 x M2.5x11
1 U = 1 HE = 1.750 inches (44,5 mm) 1 HP = 1 TE = 0.200 inch (5,1 mm)
5 9/16
(142,2)
28 HP (28 TE)
Optional screw terminal
7 11/32 (186,7)
8 33/64 (216,2)
Approvals tag
Intrinsic safety shield (Model 3500 only)
6 11/16 (169,9)
7 29/32 (200,6)
1
(25,4)
inches
(mm)
inches
(mm)
Rear rail for mounting connectors
19-inch (486,2 mm) rack
Planning

1.3 Cable lengths

Maximum cable length from the sensor to the Model 3500 transmitter depends on the installation type and cable type.
Installation type Maximum cable length
4-wire remote transmitter Figure 1-3, and Table 1-1 for maximum length of the 4-wire
Remote core processor with remote transmitter
cable
Figure 1-4, and Table 1-1 for maximum length of the 4-wire
cable and the 9-wire cable
Installation Manual 7
Loading...