Micro Motion Guide: PROLINK QUICK REFERENCE GUIDE | Micro Motion Manuals & Guides

Quick Reference Guide
P/N 20001908, Rev. GA August 2009
ProLink® II
Installation and Startup
For customer service, phone the support center nearest you:
In Canada and Latin America, phone +1 303-527-5200
•In Asia:
- In Japan, phone 3 5769-6803
- In other locations, phone +65 6777-8211 (Singapore)
•In Europe:
- In the U.K., phone 0870 240 1978 (toll-free)
- In other locations, phone +31 (0) 318 495 555
(The Netherlands)
Customers outside the U.S.A. can also send an email to Micro Motion customer service at:
Flow.Support@Emerson.com

BEFORE YOU BEGIN

WARNING

About these instructions

This quick reference guide explains basic installation guidelines for Micro Motion
®
ProLink®II software.
For complete instructions about installation and use, refer to the ProLink II manual.
An improper connection between ProLink II and the transmitter can cause an explosion.
To avoid causing an explosion, be sure to connect ProLink II to the transmitter using safe methods. To avoid causing an explosion:
• Do not open a non-intrinsically safe wiring compartment in a hazardous area.
• Do not use the computer running ProLink II in a hazardous area.
Note: If you have a Model 2700 transmitter with transmitter software earlier than v3.4, and you have the concentration measurement application installed, you cannot access the concentration measurement functions with ProLink II v2.1 or later. Contact Micro Motion for alternative solutions.
©2009, Micro Motion, Inc. All rights reserved. ELITE, ProLink, and the Micro Motion logo are registered trademarks of Micro Motion, Inc., Boulder, Colorado. MVD and MVD Direct Connect are trademarks of Micro Motion., Inc., Boulder, Colorado. Micro Motion is a registered trade name of Micro Motion, Inc., Boulder, Colorado. The Emerson logo is a trademark of Emerson Electric Co. All other trademarks are property of their respective owners.
1

PC requirements

To install and run ProLink II, your PC must meet or exceed the following requirements:
200 MHz Pentium processor
One of the following:
- Windows XP with Service Pack 1 and 128MB RAM
- Windows 2000 with Service Pack 3 and 128MB RAM
80MB of available hard disk space
Video with support for 256 or more colors
CD-ROM Drive
An available serial port or USB port

Installation kits

Micro Motion provides ProLink II installation kits for the following connection types:
RS-485 to serial port (RS-232)
RS-485 to USB port
Bell 202 to serial port (RS-232)
Bell 202 to USB port
The installation kits include signal converters and assorted adapters, cables, and testers. If you need a ProLink II installation kit, contact Micro Motion.
Note: If you do not use a signal converter supplied by Micro Motion, it is your responsibility to ensure that your equipment provides equivalent functionality. See the ReadMe.txt file in the ProLink II installation directory, or contact Micro Motion customer support for assistance or additional information.
Note: A Windows driver is required for correct operation of the Bell 202 USB signal converter. This driver is provided with the installation kit. Ensure that the driver is installed before attempting to connect through the USB port. If this driver is not installed, Windows will not recognize the USB converter when it is plugged into the USB port.
2
STEP 1. Install the ProLink II software
To install ProLink II software:
1. Insert the ProLink II CD-ROM into the PC’s CD-ROM drive.
2. If the setup program does not start automatically, locate and run the SETUP.EXE file. The file is located in the root directory on the CD-ROM (e.g., D:\setup.exe, where “D” is your CD-ROM drive letter).
Note: The user who installs the ProLink II software must have permission to write to the registry.
3. Follow the on-screen instructions to complete the installation. If you have a previous version of ProLink II installed on your PC, you may be prompted to remove it before installing the new version.
Warning: The ProLink II site key is associated with a specific disk drive and specific folder on your PC. If you decide to move ProLink II after installation, you will have to transfer the license and reinstall ProLink II. To avoid this step, be sure to install ProLink II into a location that you can use permanently.
4. Follow the on-screen instructions to generate the temporary license. This license will allow you to run ProLink II with full functionality for seven days, starting from the current date and time.
5. A site key is required for a permanent license. Follow the instructions in the ProLink II manual to obtain and configure a site key.
Warning: The temporary license will expire after seven days, and ProLink II will not connect to a transmitter. Be sure to configure the site key before the temporary license expires.
In typical installations, the manual is installed with the ProLink II program, and can be opened from the Micro Motion folder in the Windows Start menu. You can also find the ProLink II manual on the installation CD, in the root directory.
Note: Adobe Acrobat Reader is required to read the ProLink II manual. The self-extracting setup file for this program is provided in the root directory of the ProLink II installation CD, if Acrobat Reader is not already installed on your system. The ProLink II setup program does not install Acrobat Reader automatically.
3
STEP 2. Connect the PC to the transmitter
1. Connect the appropriate signal converter to your PC’s serial or USB port, using adapters as required.
For connections using the Bell 202 physical layer, use the
Bell 202–RS-232 signal converter.
For connections using the RS-485 physical layer, use the
RS-485–RS-232 signal converter.
2. Connect the two leads of the signal converter to the appropriate terminals on your transmitter. See Table 1.
Table 1. Transmitter terminals for ProLink II connections
Terminals for connection type
HART/
Bell 202
Transmitter
IFT9701/9703 4-20 + 4-20 –
RFT9712 17 16 21 22
RFT9739
• Rack-mount Z30 D30 Z22 D22 Z22 D22
• Field-mount 17 18 27 26 27 26
• Model 1700/2700 with analog outputs
• LFT field-mount with output option codes 1, 3
Model 1700/2700 with intrinsically safe
(1)
outputs
• Model 2700 with configurable input/ outputs
• LFT field-mount with output option code 4
• Model 2700 with F
OUNDATION
• LFT field-mount with output option code 6
Model 2700 with PROFIBUS-PA
Model 2200S HART clips
fieldbus
PV+ PV– A B A B A B
1 2 56 56 87
12 87
12 87
HART/
RS-485
Modbus/
RS-485
Service
port
87
87
4