Micro Matic AX50 User Manual

Ax50
Carbon Dioxide detector with optional oxygen sensor
Analyser specifications:
Analyser type:
Fixed
Power:
230V AC, 110V AC, 9 to 24V DC (24hour battery backup option available)
Display:
Optional 4 digit Liquid Crystal Display
Operating temp:
-5 to +40oC
Power consumption:
<5 VA
Output options:
Sensor specifications:
Carbon dioxide (optional oxygen sensor may be fitted)
Measurement technique:
Infra-red (oxygen - electrochemical)
Range:
0.1 to 5% (oxygen - 0.1 to 25%)
Resolution:
0.01% (oxygen - 0.1%)
Alarm set points:
0.5 and 1.5% (optional alarm set points available) (oxygen - 18 and 19.5%)
Response time:
45 seconds to T90 (oxygen - 15 seconds to T90)
Warm up time:
40 seconds (oxygen - 10 seconds)
CO2 Expected life:
> 15 years warranty: 15 years
O2 Expected life:
2 years warranty: 1 year
4 to 20mA, 2 x relays, 0 to 1V
Dimensions:
175 x 110 x 75mm (analyser) 72 x 170 x 45mm (repeater)
IP Rating:
IP65 (apart from quick connect repeater which is IP43)
Sounder:
Minimum 75dbA
Internal Strobe:
Intensity >100cd
Warranty:
2 years electrical
Analyser approvals:
CE, EN50270:1999, EN61000-6-3:2001+A11:2004, BS EN 61010-1:2001, IEC 61010-1(2ed), DIN 6653-2:2004 (TRSK313) and AS61010.1-2003 (Australia & New Zealand), CSA, Master Contract 239512, Certificate
1909026.
Analox has a policy of continuous improvement and we reserve the right to upgrade or change specifications without prior notice. Full technical specifications are available upon request.
datasheet
5981 Engineer Drive, Huntington Beach,
CA 92649
T: 1 (714)891-4478 F: 1 (714)891-4479 W: analox.net