Pull out the protective strip from the battery
compartment.
2) Set the month – Use M Button to set the Month.
Press the ON/OFF Button to confirm.
1) Set the year – Upon removing the protective
strip or installing new batteries, the Year number
flashes in the display. Use the M Button to select
the Year. Press the ON/OFF Button to confirm your
selection.
M Button equals select
ON/OFF Button equals confirm
3) Set the day – Press M Button to set the Day. Press
the ON/OFF Button to confirm.
8
4) Set the time – Once the Hour and Minutes have
been set and the ON/OFF Button pressed, the
date and time are set, and the current time is
displayed.
5) To change the date and time, briefly take out
and put back one battery from the battery
compartment. The Year number will flash.
Complete the process as described above.
Confirm cuff size
A variety of different cuff sizes are available for use
with the WatchBP O3 device.
please use only Microlife cuffs!
*
M (Medium size)
22 - 32 cm (8.7 - 12.6 inches)
M is the correct size for most people.
L (Large size)
32-42 cm (12.6-16.5 inches)
9
EN
AMBULATORYHOMECASUAL
AMBULATORYHOMECASUAL
AMBULATORYHOMECASUAL
Selecting the operation mode
AMBULATORY HOME CASUAL
AMBULATORYHOMECASUAL
AMBULATORY HOME CASUAL
Prior to each measurement, use the Mode Switch
on the side of the device to select the proper
measurement mode. The WatchBP O3 offers three
measurement modes: «AMBULATORY», «HOME» or
«CASUAL» mode.
The device automatically takes measurements
at fixed intervals of 15, 20, 30, or 60 minutes, as
programmed by the physician.
Set awake and asleep hours
To better suit each patient’s lifestyle, awake and
asleep hours can be programmed using the provided
WatchBP O3 software. Intervals for the awake and
asleep hours can also be programmed independently.
15
30
minutes
20
The default measurement interval is 30 minutes for the
*
awake hours and 60 minutes for the asleep hours.
60
Setting Ambulatory Measurement Schedule
Awake fromwithminutes interval06 AM10 PM30~
Asleep fromwithminutes interval10 PM06 AM60~
11
EN
AMBULATORYHOMECASUAL
AMBULATORYHOMECASUAL
Selecting the operation mode (cont.)
Two measurement periods
The awake measurement period can be programmed
to start at anytime between 4AM to 10AM, and the
asleep measurement period can be set to anytime
between 9PM to 2AM. Measurement intervals can be
set to 15, 20, 30, or 60 minutes for both awake and
asleep time periods.
12
«HOME» Mode
Select «HOME» mode for patient home blood
pressure measurement in accordance with the
guidelines of the European Society of Hypertension
(ESH) and American Heart Association (AHA).
No measurements on non-work days
The patient should carry out readings on 7
consecutive working days (or normal week days),
No readings should be taken on «non-working»
days (or particularly relaxing days) in this mode!
Two sets of measurements per day
ESH guidelines recommend one double measurement
be taken in the morning between 06:00 - 09:00
and one double measurement taken in the evening
between 18:00 - 21:00.
JAN
30
7
working
days
X1
06:00 – 09:00
X1
18:00 – 21:00
13
EN
Selecting the operation mode (cont.)
Extended measurement period
The WatchBP O3 device offers an extended
measurement period and allows morning
measurements between 04:00 - 12:00 and evening
measurements between 18:00 - 24:00.
Outside these times,
measurements
cannot be taken
and the symbol
on the left will be
displayed on the
screen.
14
Evaluation
After measurements have been carried out for a
total of 7 working days, patients return to the office
with the WatchBP O3 device for an evaluation of
their home blood pressure measurement data.
When
measurements
have been carried
out for the full 7
days, the doctor
symbol will flash on
the screen.
AMBULATORYHOMECASUAL
«CASUAL» Mode
In «CASUAL» mode, the device functions like
a regular blood pressure monitor – single
measurements are automatically stored and can be
reviewed by the physician at a later date.
Anytime
250 measurements safely stored
The WatchBP O3 device can store up to 250 single
measurements in «CASUAL» mode.
When memory is full, each new measurement will
*
automatically overwrite the earliest measurement.
250
Measurements
15
EN
SYS
mmHg
DIA
mmHg
PUL
/min
Recording the taking of medication
Medication record
The patient can record the time medication is taken
2) Release the Medication Button and the Pill icon
will flash in alternation with the recorded time.
by pressing the Medication Button.
Press and hold
1) Press and hold the Medication Button for 2 seconds
and the Pill icon will appear.
Press and hold
for 2 Seconds...
A Medication record can be recorded in any of the three modes.* The beeper can be disabled via software setting.
*
16
3) Medication record is saved after the beep sound.
Saved
50 records safely stored
The WatchBP O3 device can store up to 50
medication records.
* When the memory is full, the device will display Full.
Delete stored medication records
To clear the memory of all medication records, press
and hold the Medication Button for 7 seconds. The
“CL” symbol will flash. Press M to delete the memory
or ON/OFF to cancel the deletion .
Press and hold
for 7 seconds...
Pressing the M Button to delete data will erase all medication
System Requirements: 550MHz CPU. 256MB Memory, 1024x768
pixel resolution, 256 color, CD-ROM drive, 1 free USB port, 40MB
free hard disk space, Microsoft Windows 2000 / XP / Vista.
Install CD
WatchBP Analyzer O3
Version 1.0.2.7
AMBULATORY HOME CASUAL
AMBULATORY HOME CASUAL
Installing the software program
1) Put the CD in the CD-ROM drive of your computer.
Alternatively click on «setup.exe» in the CD’s
directory.
2) Simply follow the instructions provide in the
installation window on the computer screen.
3) When installation is finished, be sure to restart the
computer before working with the program for the
first time.
Restart
your
computer
18
Installation
Connecting the device to a computer
1) Connect the device to computer. A successful
connection is displayed by «PC» on the device.
2) Start the software program.
3) Enter name, identity number, and date of birth to
create a new record (if required).
Programming the interval schedule
1) Using the drop-down menu on the lower-left of
the screen, choose from 4AM to 10AM as the start
of the awake hours.
3) Assign the measurement intervals for the awake
and asleep hours by using the drop-down menu
to choose from 15, 20, 30, and 60 minutes as the
measurement interval.
Awake from 06 AM10 PM~
2) Using the drop-down menu on the lower-left of
the screen, choose from 9 PM to 2 AM as the start
of the asleep hours.
Asleep from 10 PM06 AM~
152030
minutes
60
4) Once you have completed the settings, press
“Program to BP device” to program the schedule
into the device.
Program to BP device
minutes interval15
20
30
60
19
EN
Taking blood pressure measurements
AMBULATORY HOME CASUAL
In «AMBULATORY» mode
Be sure the device is set to «AMBULATORY» Mode.
1) Preparing measurement arm – Remove
all clothing covering or constricting the
measurement arm.
Avoid rolling up long
*
sleeves, as this may
lead to constriction
of blood flow to the
measurement arm.
20
2) Positioning the cuff and device – Fit the cuff
closely, but not too tight. Make sure that the cuff
is 2~3 cm (1 inch) above the elbow with the tube
on the inside of the arm. The measurement tube
should point upward and be mounted over the
patient’s shoulder.
2–3cm
Adjust the tube holder on the belt of the
*
pouch so it is properly positioned on the
shoulder. Attach the tube to the holder
so the tube goes up over the shoulder to
the other side of the body. An alternative
method is to use a waist belt.
3) Proper Positioning the cuff using Anchor Strap
Option 1: Use the Shoulder Sling a and Anchor
Strap b to position the cuff as demonstrated in the
diagram below.
Instructions: Place the Shoulder Sling over the left
shoulder. Insert the device into the holster. Position
the device at front. Apply the Cuff to the arm. Buckle
up Anchor Strap with Shoulder Sling. Snap the
connector of Anchor Strap into D-ring of cuff. Adjust
length for fi t and comfort.
Option 2: Use the Shoulder Strap c and Anchor
Strap b to position the cuff as demonstrated.
Instructions: Place the Shoulder Strap over both
shoulders as demonstrated in the diagram. Connect
the device to a belt. Position the device at front.
Apply the Cuff to the arm. Buckle up Anchor Strap
with Shoulder Strap. Snap the connector of Anchor
Strap into D-ring of cuff. Adjust length for fi t and
comfort.
21
EN
4) Next measurement indicator – The device will
display the next measurement time, indicated by
a countdown in minutes on the display.
The screen will display X countdown minutes to indicate
*
the time to the next automatic measurement.
22
5) Measurement reminder – One minute before
the next scheduled measurement, the device will
partially inflate and immediately deflate the cuff
to remind the patient of the next measurement.
1 min
Reminder
Measurement reminders
*
will be disabled for the
asleep hours.
Taking blood pressure measurements (cont.)
6) Measurement reminder – Five seconds before
the next measurement, the device will emit a
short series of beeps to notify the patient of the
coming measurement.
5 sec
Reminder
The beeper of Ambulatory Mode can be disabled via software
*
setting.
The device will not beep prior
*
to asleep measurement in
«AMBULATORY » mode.
7) During measurements – the patient should be
reminded to remain still, refrain from talking,
and to breath normally during the measurement.
If driving or operating equipment when a
measurement begins, the patient should, when
safe, relax the measurement arm.
The patient can stop any single measurement at anytime by
*
pressing the ON/OFF Button.
23
EN
8) Repeat measurements in the case of an
144
Measurements
error – The device will automatically repeat the
measurement after a two minute countdown
should an error occur during measurement.
A repeat
measurement
is performed
automatically if
an error occurs.
If the repeat measurement encounters an error, the device will
*
stop taking measurements. The patient should return the device
to the physician to determine the cause of error.
24
9) Storing measurement data – The WatchBP O3
automatically stores each measurement result,
along with the measurement date and time.
A total of 144 measurements can be stored in
«AMBULATORY» mode.
The display of BP reading and memory of Ambulatory Mode
*
can be disabled via software setting.
Taking blood pressure measurements (cont.)
AMBULATORY HOME CASUAL
AMBULATORY HOME CASUAL
In «HOME» mode
Be sure the device is set to «HOME» Mode.
1) Before the measurement – Patients should be
informed to avoid physical activity, eating or
smoking before each measurement. The patient
should sit down for at least 5 minutes before the
measurement and relax.
2) Applying the cuff – Patients should be trained
on how to properly fit the cuff to their own arm.
The cuff should fit closely around the arm, but not
too tight, and be placed 2~3cm above the elbow
with the tube on the inside of the arm. The patient
should support the arm at the same height as the
heart during measurement.
Additional instructions on taking proper blood pressure
*
measurement can be found on the www.watchbp.com website.
25
EN
3) Start the measurement – Press the ON/OFF
SYS
mmHg
DIA
mmHg
PUL
/min
Button to start measurement.
4) During the measurement –The cuff will inflate
automatically. One measurement cycle includes
two measurements. Once the first measurement
is complete, the second measurement will begin
after 60-seconds.
12
60 sec.
26
5) Finishing the measurement – Once the two
measurements are complete, measurement
data is automatically stored for later reference
by the physician. If an error displays after the
measurements, the process should be repeated
once again.
Taking a blood pressure measurements (cont.)
AMBULATORY HOME CASUAL
AMBULATORY HOME CASUAL
AMBULATORY HOME CASUAL
In «CASUAL» mode
Be sure the device is set to «CASUAL» Mode.
1) Before each measurement – Patients should
be informed to avoid physical activity, eating or
smoking before each measurement. The patient
should sit down for at least 5 minutes before the
measurement and relax.
2) Applying the cuff – Patients should be trained
on how to properly fit the cuff to their own arm.
The cuff should fit closely around the arm, but not
too tight, and be placed 2~3cm above the elbow
with the tube on the inside of the arm. The patient
should support the arm at the same height as the
heart during measurement.
Additional instructions on taking proper blood pressure
*
measurement can be found on the www.watchbp.com website.
27
EN
3) Start the measurement – Press the ON/OFF
SYS
mmHg
DIA
mmHg
PUL
/min
Button to start measurement.
4) During the measurement –The cuff will inflate
automatically. A single measurement will be
completed for each push of the ON/OFF Button.
28
5) Finishing the measurement – Once the
measurement is complete, measurement
data is automatically stored for later reference
by the physician. If an error displays after the
measurements, the process should be repeated
once again.
6) Storing measurement data – The WatchBP O3
automatically stores each measurement result,
along with the measurement date and time.
A total of 250 measurements can be stored in
«CASUAL» mode.
250
Measurements
AMBULATORY HOME CASUAL
Viewing, deleting and transferring measurements
Viewing measurements
1) Use the Mode switch to first select the type of
measurements wished to be viewed.
2) Then press the M Button.
In «AMBULATORY» mode
1) When the M Button is pressed, it briefly displays
the total number of measurements stored, e.g.
N=20.
«A» is displayed when
*
the number shown is the
average of all data.
«- -» will display when the
*
number of measurements is
less than 12.
29
EN
2) Pressing the M Button again displays the average
of all awake hours.
3) Pressing M Button once again shows the average
of all night hours.
In «Home» mode
1) When the M Button is pressed, it briefly displays
the total number of measurements stored, e.g.
N=20.
All individual readings can be viewed by repeatedly pressing
*
the M Button.
The display of BP reading and memory of Ambulatory Mode
*
can be disabled via software setting.
30
«A» is displayed when
*
the number shown is
the average of all data.
«- -» will display when the
*
number of measurements
is less than 12.
Loading...
+ 126 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.