Microlife AG
Espenstrasse 139
9443 Widnau / Switzerland
www.microlife.com
а, Ермолаевский пер., д.22-26, стр.1 Телефоны
Место производства:
ONBO Electonic (Shenzhen) Co., Ltd., Китай
Адрес: No. 497, Ta Laneg Nan Road, Ta Laneg Street,
Baoan District, Shenzhen, China
Сделано в Китае
IB BP W100 EN-RU 3919
Прибор для измерения артериального
давления и частоты пульса
BP W100
EN 1
RU 12
Microlife BP W100
MicrolifeBPW100
I
ALAM
II
BP W100Guarantee Card
3
65
2
1
4
AT
7
AN
AK
AO
8
9
Name of Purchaser /
Ф.И.О. покупателя
Serial Number /
Серийный номер
Date of Purchase /
Дата покупки
Specialist Dealer /
Специализированный дилер
Microlife BP W100
1
ON/OFF button
2
Display
3
Battery Compartment
4
Cuff
5
M-button (memory)
6
Time Button
Display
7
Systolic Value
8
Diastolic Value
9
Pulse Rate
AT
Date/Time
AK
Alarm Time
AL
Stored Value
AM
Heart Arrhythmia Indicator
AN
Pulse
AO
Battery Display
EN
Intended use:
This oscillometric blood pressure monitor is intended for measuring
non-invasive blood pressure in people aged 12 years or older.
Dear Customer,
Your new Microlife blood pressure monitor is a reliable medical device
for taking measurements on the wrist. It is simple to use, accurate and
comes highly recommended for blood pressure monitoring in your
home. This device was developed in collaboration with physicians and
clinical tests prove its measurement accuracy to be very high.*
If you have any questions, problems or want to order spare parts
please contact your local Microlife-Customer Service. Your dealer or
pharmacy will be able to give you the address of the Microlife dealer
in your country. Alternatively, visit the internet at www.microlife.com
where you will find a wealth of invaluable information on our products.
Stay healthy – Microlife AG!
* This device is clinically tested according to the British and Irish
Hypertension Society (BIHS) protocol. Highest possible grading for
Systolic (A) and Diastolic (A) measurement accuracy.
EN
1BP W100
Table of Contents
1. Explanation of symbols
2. Important Facts about Blood Pressure and Self-Measurement
• How do I evaluate my blood pressure?
3. Using the Device for the First Time
• Activating the fitted batteries
• Setting the date and time
4. Taking a Blood Pressure Measurement
5. Appearance of the Heart Arrhythmia Indicator for early
Detection
6. Data Memory
• Viewing the stored values
• Memory full
• Clearing all values
• How not to store a reading
7. Setting the Alarm Function
8. Battery Indicator and Battery change
• Low battery
• Flat battery – replacement
• Using rechargeable batteries
2
9. Error Messages
10. Safety, Care, Accuracy Test and Disposal
• Safety and protection
•Device care
• Cleaning the cuff
• Accuracy test
•Disposal
11. Guarantee
12. Technical Specifications
1. Explanation of Symbols
Batteries and electronic devices must be disposed of in
accordance with the locally applicable regulations, not with
domestic waste.
Read the instructions carefully before using this device.
Type BF applied part
Keep dry
Conformity mark
2. Important Facts about Blood Pressure and Self-
N
Type approval of measuring device
S
N
Serial number
Catalogue number
Manufacturer
Class II equipment
Operating temperature restriction
Operating
10 - 40 °C
Storage temperature restriction
-20 - +55 °C
Storage
CE Marking of Conformity
Measurement
Blood pressure
generated by the pumping of the heart. Two values, the
(upper) value and the
The device indicates the pulse rate (the number of times the heart
beats in a minute).
Permanently high blood pressure values can damage your
health and must be treated by your doctor!
Always discuss your values with your doctor and tell him/her if you
have noticed anything unusual or feel unsure. Never rely on
single blood pressure readings.
A number of factors can affect the accuracy of measurements
taken on the wrist.
measurement taken on the upper arm. We therefore advise you to
compare these values with those produced by the upper arm
measurement and discuss them with your doctor.
Enter your readings in the enclosed blood pressure diary. This
will give your doctor a quick overview.
There are many causes of excessively
values
ment where appropriate. Besides medication, relaxation techniques,
weight loss and exercise can also lower your blood pressure.
is the pressure of the blood flowing in the arteries
systolic
diastolic
(lower) value, are always measured.
In some cases, the result may differ from the
high blood pressure
. Your doctor will explain them in more detail and offer treat-
EN
3BP W100
Under no circumstances should you alter the dosages of
drugs or initiate a treatment without consulting your doctor.
Depending on physical exertion and condition, blood pressure is
subject to wide fluctuations as the day progresses.
You should
therefore take your measurements in the same quiet conditions
and when you feel relaxed!
Take at least two measurements per
day, one in the morning and one in the evening.
It is quite normal for two measurements taken in quick succession
to produce significantly different results.
Deviations between measurements taken by your doctor or in the
pharmacy and those taken at home are quite normal, as these
situations are completely different.
Several measurements provide a much clearer picture than just
one single measurement.
Leave a small break of at least 15 seconds between two
measurements.
If you are pregnant, you should monitor your blood pressure
regularly as it can change drastically during this time.
If you suffer from an irregular heartbeat (arrhythmia, see
«Section 5.»), measurements taken with this device should only
be evaluated after consultation with your doctor.
The pulse display is not suitable for checking the frequency
of heart pacemakers!
4
How do I evaluate my blood pressure?
Table for classifying blood pressure values in adults in accordance
with the World Health Organisation (WHO) in 2003. Data in mmHg.
RangeSystolicDiastolic
1. blood pressure
normal
2. blood pressure
normal
3. blood pressure
slightly high
4. blood pressure too
high
5. blood pressure far
too high
6. blood pressure
dangerously high
< 120 < 80Self-check
120 - 12980 - 84Self-check
130 - 13985 - 89Consult your
140 - 15990 - 99Seek medical
160 - 179100 - 109 Seek medical
≥180≥110Urgently seek
Recommendation
doctor
advice
advice
medical advice!
The higher value is the one that determines the evaluation. Example:
a readout value between 150/85 or 120/98 mmHg indicates «blood
pressure too high».
3. Using the Device for the First Time
Activating the fitted batteries
Pull out the protective strip from the battery compartment 3.
Setting the date and time
1. After the new batteries are fitted, the year number flashes in the
display. You can set the year by pressing the M-button 5. To
confirm and then set the month, press the time button 6.
2. Press the M-button to set the month. Press the time button to
confirm and then set the day.
3. Follow the instructions above to set the day, hour and minutes.
4. Once you have set the minutes and pressed the time button, the
date and time are set and the time is displayed.
5. If you want to change the date and time, press and hold the time
button down for approx. 3 seconds until the year number starts to
flash. Now you can enter the new values as described above.
4. Taking a Blood Pressure Measurement
Checklist for taking a reliable measurement
1. Avoid activity, eating or smoking immediately before the measurement.
2. Sit down on a back-supported chair and relax for 5 minutes. Keep
the feet flat on the floor and do not cross your legs.
3. Always measure in a sitting position and on the same wrist. Use
the wrist which usually shows higher blood pressure values.
4. Remove any items of clothing and your watch, for example, so
that your wrist is free.
5. Always ensure that the cuff is positioned correctly, as shown in the
pictures illustrated on the short instruction card.
6. Fit the cuff comfortably but not too tight. The cuff will cover a wrist
circumference of 13.5 to 21.5 cm (5.25 - 8.5 inches).
7. Support your arm in a relaxed position and ensure that the device
is at the same height as your heart.
8. Press the ON/OFF button 1 to start the measurement.
9. The cuff will now pump up automatically. Relax, do not move and
do not tense your arm muscles until the measurement result is
displayed. Breathe normally and do not talk.
10.When the correct pressure is reached, the pumping stops and the
pressure falls gradually. If the required pressure was not reached,
the device will automatically pump some more air into the cuff.
11.During the measurement, the heart symbol AN flashes in the
display and a beep sounds every time a heartbeat is detected.
12.The result, comprising the systolic 7 and the diastolic 8 blood
pressure and the pulse rate
Note also the explanations on further display symbols in this booklet.
13.Remove and switch off the monitor and enter the result in the
enclosed blood pressure pass. (The monitor does switch off automatically after approx. 1 min.).
9
is displayed and a long beep is heard.
EN
5BP W100
You can stop the measurement at any time by pressing the
ON/OFF button (e.g. if you feel uneasy or an unpleasant pressure sensation).
5. Appearance of the Heart Arrhythmia Indicator for
early Detection
This symbol AM indicates that certain pulse irregularities were detected
during the measurement. In this case, the result may deviate from your
normal blood pressure – repeat the measurement. In most cases, this is
no cause for concern. However, if the symbol appears on a regular basis
(e.g. several times a week with measurements taken daily) we advise you
to tell your doctor. Please show your doctor the following explanation:
Information for the doctor on frequent appearance of the
Arrhythmia indicator
This device is an oscillometric blood pressure monitor that also
analyses pulse frequency during measurement. The device is clinically tested.
The arrhythmia symbol is displayed after the measurement, if pulse
irregularities occur during measurement. If the symbol appears
more frequently (e.g. several times per week on measurements
performed daily) we recommend the patient to seek medical
advice.
This device does not replace a cardiac examination, but serves to
detect pulse irregularities at an early stage.
6
6. Data Memory
At the end of each measurement, this device automatically stores the
result, including date and time.
Viewing the stored values
Press the M-button 5 briefly, when the device is switched off. The
display first shows «
that there are 17 values in the memory. The device then switches to the
last stored result.
Pressing the M-button again displays the previous value. Pressing the
M-button repeatedly enables you to move from one stored value to
another.
Memory full
When the memory has stored 200 results, the memory is full.
From this point onwards, a new measured value is stored by
overwriting the oldest value.
Clearing all values
If you are sure that you want to permanently remove all stored
values, hold down the M-button (the device must have been switched
off beforehand) until «CL» appears and then release the button. To
permanently clear the memory, press the M-button while «CL» is
flashing. Individual values cannot be cleared.
M» AL
and then a value, e.g. «
M 17
». This means
How not to store a reading
As soon as the reading is displayed press and hold the ON/OFF
button 1 until «M» AL is flashing. Confirm to delete the reading by
pressing the M-button 5.
7. Setting the Alarm Function
This device allows you to set 2 alarm times at which an alarm signal
will then be triggered. This can be a useful aid, for instance as a
reminder to take medication.
1. To set an alarm time, press the time button 6 (the device must
have been switched off beforehand) and immediately afterwards
the M-button 5 and hold both down until the bell symbol AK
appears in the bottom left of the display. Then release both
buttons. The flashing «1» in the display indicates that the first
alarm time can now be set.
2. Press the time button to set the hours – the hour display flashes
and pressing the M-button allows you to set the alarm hour. To
confirm, press the time button.
3. The minute display will now flash. The minutes can be set using
the M-button. To confirm, press the time button again.
4. The bell symbol will now flash. Use the M-button to select whether
the alarm time is to be active (bell) or inactive (crossed-out bell).
To confirm, press the time button.
To set a second alarm time, proceed as above but if the «1» flashes,
press the M-button to select «
An active alarm time is indicated by the bell symbol in the display.
The alarm will sound at the set time every day.
To switch-off the alarm when it is sounding, press the ON/OFF
2
» and confirm with the time button.
button 1.
To permanently switch off the alarm, proceed as above and select the
crossed-out bell symbol. This will then disappear from the display.
The alarm times must be re-entered each time the batteries are
replaced.
8. Battery Indicator and Battery change
Low battery
When the batteries are approximately ¾ empty the battery symbol AO
will flash as soon as the device is switched on (partly filled battery
displayed). Although the device will continue to measure reliably, you
should obtain replacement batteries.
Flat battery – replacement
When the batteries are flat, the battery symbol AO will flash as soon
as the device is switched on (flat battery displayed). You cannot take
any further measurements and must replace the batteries.
1. Open the battery compartment 3 by pulling off the cap.
EN
7BP W100
Loading...
+ 18 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.