Read the instructions carefully before using this device.
Type BF applied part
1
EN
Dear Customer,
Your new Microlife blood pressure monitor is a reliable medical
device for taking measurements on the upper arm. It is simple to use,
accurate and comes highly recommended for blood pressure monitoring in your home. This device was developed in collaboration with
physicians and clinical tests carried out prove its measurement accuracy to be of a very high standard.*
Please read through these instructions carefully so that you understand all functions and safety information. We want you to be happy
with your Microlife product. If you have any questions, problems or
want to order spare parts please contact Microlife-Customer Service.
Your dealer or pharmacy will be able to give you the address of the
Microlife dealer in your country. Alternatively, visit the internet at
www.microlife.com where you will find a wealth of invaluable information on our products.
Stay healthy – Microlife AG!
* This device uses the same measuring technology as the award
winning «BP 3BTO-A» model tested according to the British Hypertension Society (BHS) protocol.
Table of Contents
1. Important Facts about Blood Pressure and Self-Measurement
• How do I evaluate my blood pressure?
2. Using the Device for the First Time
• Inserting the batteries
• Selecting the correct cuff
3. Taking a Blood Pressure Measurement using this Device
4. Data Memory
5. Battery Indicator and Battery change
• Low battery
• Flat battery – replacement
• Which batteries and which procedure?
• Using rechargeable batteries
6. Error Messages
7. Safety, Care, Accuracy Test and Disposal
• Safety and protection
• Device care
• Accuracy test
•Disposal
8. Guarantee
9. Technical Specifications
Guarantee card (see Back Cover)
1. Important Facts about Blood Pressure and SelfMeasurement
Blood pressure
generated by the pumping of the heart. Two values, the
(upper) value and the
The device indicates the pulse rate (the number of times the heart
beats in a minute).
Permanently high blood pressure values can damage your
health and must be treated by your doctor!
Always discuss your values with your doctor and tell him/her if you
have noticed anything unusual or feel unsure. Never rely on
single blood pressure readings.
Enter your readings in the enclosed blood pressure diary. This
will give your doctor a quick overview.
There are many causes of excessively
values
ment where appropriate. Besides medication, relaxation techniques,
weight loss and exercise can also lower your blood pressure.
Under no circumstances should you alter the dosages of any
drugs prescribed by your doctor!
Depending on physical exertion and condition, blood pressure is
subject to wide fluctuations as the day progresses. You should
therefore take your measurements in the same quiet condi-
is the pressure of the blood flowing in the arteries
diastolic
(lower) value, are always measured.
. Your doctor will explain them in more detail and offer treat-
high blood pressure
systolic
2BP A90
EN
tions and when you feel relaxed! Take at least two measure-
ments per day, one in the morning and one in the evening.
It is quite normal for two measurements taken in quick succession
to produce significantly different results.
Deviations between measurements taken by your doctor or in the
pharmacy and those taken at home are quite normal, as these
situations are completely different.
Several measurements provide a much clearer picture than just
one single measurement.
Leave a small break of at least 15 seconds between two
measurements.
If you are pregnant, you should monitor your blood pressure very
closely as it can change drastically during this time!
If you suffer from an irregular heartbeat, measurements taken
with this device should only be evaluated after consultation with
your doctor.
The pulse display is not suitable for checking the frequency
of heart pacemakers!
3
How do I evaluate my blood pressure?
Table for classifying blood pressure values in adults in accordance
with the World Health Organisation (WHO) in 2003. Data in mmHg.
RangeSystolicDiastolic Recommendation
blood pressure too
low
1. blood pressure
optimum
2. blood pressure
normal
3. blood pressure
slightly high
4. blood pressure too
high
5. blood pressure far
too high
6. blood pressure
dangerously high
The higher value is the one that determines the evaluation. Example:
a readout value between 150/85 or 120/98 mmHg indicates «blood
pressure too high».
100
100 - 120 60 - 80
120 - 130 80 - 85
130 - 140 85 - 90
140 - 160 90 - 100
160 - 180 100 - 110
180
60
110
Consult your doctor
Self-check
Self-check
Consult your doctor
Seek medical advice
Seek medical advice
Urgently seek
medical advice!
2. Using the Device for the First Time
Inserting the batteries
After you have unpacked your device, first insert the batteries. The
battery compartment
(4 x 1.5 V, size AA), thereby observing the indicated polarity.
Selecting the correct cuff
Microlife offers 3 different cuff sizes: S, M and L. Select the cuff size to
match the circumference of your upper arms (measured by close fitting
in the centre of the upper arm). M is the correct size for most people.
Cuff sizefor circumference of upper arm
S17 - 22 cm (6.75 - 8.75 inches)
M22 - 32 cm (8.75 - 12.5 inches)
L32 - 42 cm (12.5 - 16.5 inches)
Only use Microlife cuffs.
Contact Microlife Service if the enclosed cuff 5 does not fit.
Connect the cuff to the device by inserting the cuff connector 6
into the cuff socket 3 as far as it will go.
4
is at the back of the device. Insert the batteries
3. Taking a Blood Pressure Measurement using this Device
Checklist for taking a reliable measurement
1. Avoid activity, eating or smoking immediately before the measurement.
2. Sit down for at least 5 minutes before the measurement and relax.
3. Always measure on the same arm (normally left).
4. Remove close-fitting garments from the upper arm. To avoid
constriction, shirt sleeves should not be rolled up - they do not
interfere with the cuff if they are laid flat.
5. Always ensure that the correct cuff size is used (marking on the cuff).
Fit the cuff closely, but not too tight.
Make sure that the cuff is positioned 2 cm above the elbow.
The artery mark located on the cuff (ca. 3 cm long bar) must
lie over the artery which runs down the inner side of the arm.
Support your arm so it is relaxed.
Ensure that the cuff is at the same height as your heart.
6. Press the ON/OFF button 1 to start the measurement.
7. The cuff will now pump up automatically. Relax, do not move and
do not tense your arm muscles until the measurement result is
displayed. Breathe normally and do not talk.
8. When the correct pressure is reached, the pumping stops and the
pressure falls gradually. If the required pressure was not reached,
the device will automatically pump some more air into the cuff.
9. During the measurement, the heart symbol AT flashes in the
display and a beep sounds every time a heartbeat is detected.
10.The result, comprising the systolic 7 and the diastolic 8 blood
pressure and the pulse 9 is displayed and longer beep is heard.
Note also the explanations on further displays in this booklet.
11.When the device has finished measuring, remove the cuff.
EN
4BP A90
12.Switch off the device. (The monitor does switch off automatically
after approx. 1 min.).
You can stop the measurement at any time by pressing the
ON/OFF button (e.g. if you feel uneasy or an unpleasant pressure sensation).
4. Data Memory
This device always stores the last result at the end of the measurement.
To recall the reading, press and hold the ON/OFF button
device is switched off. All display elements are shown now. Release the
button when the stored result with the letter «
5. Battery Indicator and Battery change
Low battery
When the batteries are approximately ¾ empty the battery symbol AK
will flash as soon as the device is switched on (partly filled battery
displayed). Although the device will continue to measure reliably, you
should obtain replacement batteries.
Flat battery – replacement
When the batteries are flat, the battery symbol AK will flash as soon
as the device is switched on (flat battery displayed). You cannot take
any further measurements and must replace the batteries.
1. Open the battery compartment 4 at the back of the device.
5
M» AL
1
while the
is displayed.
2. Replace the batteries – ensure correct polarity as shown by the
symbols in the compartment.
Which batteries and which procedure?
Use 4 new, long-life 1.5 V, size AA batteries.
Do not use batteries beyond their date of expiry.
Remove batteries if the device is not going to be used for a
prolonged period.
Using rechargeable batteries
You can also operate this device using rechargeable batteries.
Only use «NiMH» type reusable batteries.
Batteries must be removed and recharged when the flat
battery symbol appears. They should not remain inside the
device as they may become damaged (total discharge as a
result of low use of the device, even when switched off).
Always remove the rechargeable batteries if you do not intend
to use the device for a week or more.
Batteries cannot be charged in the blood pressure monitor.
Recharge batteries in an external charger and observe the
information regarding charging, care and durability.
6. Error Messages
If an error occurs during the measurement, the measurement is interrupted and an error message, e.g. «ERR 3», is displayed.
ErrorDescription Potential cause and remedy
«
ERR 1
» Signal too
weak
ERR 2
» Error signal During the measurement, error signals were
«
ERR 3
» No pressure
«
«
«
in the cuff
ERR 5
» Abnormal
result
HI
»Pulse or cuff
pressure too
high
The pulse signals on the cuff are too weak.
Re-position the cuff and repeat the
measurement.*
detected by the cuff, caused for instance by
movement or muscle tension. Repeat the
measurement, keeping your arm still.
An adequate pressure cannot be generated
in the cuff. A leak may have occurred. Check
that the cuff is correctly connected and is not
too loose. Replace the batteries if necessary.
Repeat the measurement.
The measuring signals are inaccurate and
no result can therefore be displayed. Read
through the checklist for performing reliable
measurements and then repeat the
measurement.*
The pressure in the cuff is too high (over
300 mmHg) OR the pulse is too high (over
200 beats per minute). Relax for 5 minutes
and repeat the measurement.*
ErrorDescription Potential cause and remedy
«LO»Pulse too
* Please consult your doctor, if this or any other problem occurs
repeatedly.
low
If you think the results are unusual, please read through the
information in «Section 1.» carefully.
The pulse is too low (less than 40 beats per
minute). Repeat the measurement.*
7. Safety, Care, Accuracy Test and Disposal
Safety and protection
This device may only be used for the purposes described in these
instructions. The manufacturer cannot be held liable for damage
caused by incorrect application.
This device comprises sensitive components and must be treated
with caution. Observe the storage and operating conditions
described in the «Technical Specifications» section.
Protect it from:
- water and moisture
- extreme temperatures
- impact and dropping
- contamination and dust
- direct sunlight
- heat and cold
EN
6BP A90
The cuffs are sensitive and must be handled with care.
Only pump up the cuff once fitted.
Do not use this device close to strong electromagnetic fields such
as mobile telephones or radio installations.
Do not use this device if you think it is damaged or notice anything
unusual.
Never open this device.
If the device is not going to be used for a prolonged period the
batteries should be removed.
Read the additional safety information in the individual sections of
this instructions.
Ensure that children do not use this device unsupervised;
some parts are small enough to be swallowed.
Device care
Clean the device only with a soft, dry cloth.
Accuracy test
We recommend this device is tested for accuracy every 2 years or after
mechanical impact (e.g. being dropped). Please contact MicrolifeService to arrange the test (see foreword).
Disposal
Batteries and electronic devices must be disposed of in accordance with the locally applicable regulations, not with
domestic waste.
7
8. Guarantee
This device is covered by a
purchase. The guarantee is valid only on presentation of the guarantee
card completed by the dealer (see back) confirming date of purchase
or the receipt.
Batteries, cuff and wearing parts are not included.
Opening or altering the device invalidates the guarantee.
The guarantee does not cover damage caused by improper
handling, discharged batteries, accidents or non-compliance with
the operating instructions.
Please contact Microlife-Service (see foreword).
3 year guarantee
from the date of
9. Technical Specifications
Operating temperature:
Storage temperature: -20 - +55 °C / -4 - +131 °F
Weight:718 g (including batteries)
Dimensions:146 x 47 x 64 mm
Measuring procedure:
10 - 40 °C / 50 - 104 °F
15 - 95 % relative maximum humidity
15 - 95 % relative maximum humidity
oscillometric, corresponding to Korotkoff
method: Phase I systolic, Phase V diastolic
Measurement range: 20 - 280 mmHg – blood pressure
Cuff pressure display
range:0 - 299 mmHg
Resolution:1 mmHg
Static accuracy:pressure within ± 3 mmHg
Pulse accuracy:± 5 % of the readout value
Voltage source:
Reference to
standards:
This device complies with the requirements of the Medical Device
Directive 93/42/EEC.
Technical alterations reserved.
40 - 200 beats per minute – pulse
4 x 1.5 V Batteries; size AA
EN 1060-1 /-3 /-4; IEC 60601-1;
IEC 60601-1-2 (EMC)
EN
8BP A90
Microlife BP A90
1
Bouton ON/OFF (marche/arrêt)
2
Ecran
3
Prise pour brassard
4
Logement des piles
5
Brassard
6
Connecteur brassard
Ecran
7
Tension systolique
8
Tension diastolique
9
Pouls
AT
Fréquence des battements de coeur
AK
Indicateur d'état de charge des piles
AL
Valeur enregistrée
Veuillez lire attentivement les instructions avant d'utiliser ce
produit.
Partie appliquée du type BF
9
FR
Cher client,
Votre nouveau tensiomètre Microlife est un appareil médical fiable
conçu pour prendre la tension sur le haut du bras. Il est facile d'emploi,
précis et vivement recommandé pour surveiller la tension chez soi. Cet
appareil a été développé en collaboration avec des médecins. Les tests
cliniques dont il a fait l'objet ont montré que les résultats affichés sont
caractérisés par une très grande précision.*
Veuillez lire ces instructions attentivement pour comprendre toutes les
fonctions et informations sur la sécurité. Nous souhaitons que cet
appareil Microlife vous apporte la plus grande satisfaction possible. Si
vous avez des questions, des problèmes ou désirez commander des
pièces détachées, veuillez contacter le Service Clients Microlife. Le
revendeur ou la pharmarcie chez qui vous avez acheté cet appareil
sont en mesure de vous fournir l'adresse du représentant Microlife
dans votre pays. Vous pouvez aussi visiter notre site Internet à
l'adresse www.microlife.fr, où vous trouverez de nombreuses et
précieuses informations sur nos produits.
Restez en bonne santé avec Microlife AG!
* Cet appareil applique la même technologie de mesure que le
modèle primé «BP 3BTO-A» testé conformément aux standards de
la Société Britannique de l'Hypertension (BHS).