Microlife WatchBP Office BASIC+, BP3AJ1-7A Instruction Manual

Ofce blood pressure measurement device with Ab detection
Instruction Manual
EN
1
1
2
Product description
Name of parts ................................................................. 3
Display ............................................................................ 4
Components and accessories ......................................... 5
Before using WatchBP Ofce
Selecting and tting the correct cuff .............................. 6
Activating the Device ..................................................7–8
Connect the cuff to the device ........................................ 9
Fitting the cuff properly .............................................9–10
Three operation modes
«SINGLE» Mode ............................................................ 11
«CYCLING» Mode .......................................................... 12
«AUSCULTATION» Mode ................................................ 12
Viewing the stored values
Viewing the stored values ............................................ 13
Special Functions
Mean arterial pressure ................................................. 13
Atrial brillation detection ...................................... 14-16
Skipping the countdown time ...................................... 17
Taking fewer than three measurements ..................... 17
Appendix
Rechargeable battery and power adaptor ................... 18
Error messages ....................................................... 19–20
Safety, care, accuracy test and disposal ................. 21–22
Technical specications ................................................ 23
Guarantee card ............................................................. 24
Table of Contents
3
SYS
mmHg
DIA
mmHg
PUL /min
Auscult.
Single Cycling
MAP
Start/Stop
Time/Test
M
(3, Afib)
BASIC
+
SYS
mmHg
DIA
mmHg
PUL /min
Auscult.
Single Cycling
MAP
Start/Stop
Time/Test
M
(3, Afib)
BASIC
+
Display
Time/Test
Start/Stop
Auscultation button
MAP
M Button (Memory)
Mode switch Single/Cycling (3, Ab)
DC 7.5V 2.0A
USB Port
Main Adapter
Cuff Socket
Product description
Name of parts
4
Display
Single Mode
Cycling MOde
Auscultation Mode
Ination indicator
(for Auscult. Mode)
External Power
PC Link Indicator
Battery Symbol
Interval Time
Month/Date Time
Systolic Value
Diastolic Value
Memory Number of Stored Data Pulse Mean Arterial Pressure
Pulse Rate
5
Product and components
Blood Pressure Device X 1
AC Adaptor X 1
(Input100 - 240V~ 50/60Hz 0.48A; Output+7.5V 2A)
Cuff for upper arm
M size (22cm~32cm) X 1 L size (32cm~42cm) X 1
Instruction Manual X 1 Quick Start Guide X 1
SYS
mmHg
DIA
mmHg
PUL
/min
Auscult.
O/I Interval
Alarm/Limit
Time/Test
SYS
mmHg
DIA
mmHg
PUL
/min
Auscult.
Alarm/Limit
How to take blood pressure measurement in three different modes
Quick start guide
Flip over the quick start guide to see ‘Product description’.
Printed 2011 June
1
Plug cuff connector in the cuff socket
Switch the mode
«Single» Mode
«Cycling» Mode
«AUSCULTATION» Mode Press Auscult.
button to begin a measurement
Note blood pressure using auscultatory method
Place the stethoscope on the hollow of the elbow, over the brachial artery
Press Start/Stop button to start a measurement
Result will be displayed after the measurement
2
3
Press to start
Single
Cycling
2
SYS
mmHg
DIA
mmHg
PUL
/min
Auscult.
Single Cycling
O/I Interval
Alarm/Limit
Time/Test
M
SYS
mmHg
DIA
mmHg
PUL
/min
Auscult.
O/I Interval
Alarm/Limit
Time/Test
SYS
mmHg
DIA
mmHg
PUL
/min
Auscult.
Alarm/Limit
Auscult.
Press Start/Stop button to start cycling measurements
Ofce blood pressure measurement device with Ab detection
Instruction Manual
EN
1
USB Cable
SYS
mmHg
DIA
mmHg
PUL /min
Auscult.
Single Cycling
MAP
Start/Stop
Time/Test
M
(3, Afib)
BASIC
+
6
Before using the device
Selecting the correct cuff
Two different cuff sizes are provided with the device: Medium and Large. Use the cuff marker to select the cuff size that best matches the circumference of the patient’s upper arm.
M (Medium size)
22 - 32 cm (8.7 - 12.6 inches)
L (Large size)
32-42 cm (12.6 - 16.5 inches)
7
Activating the Device
Open the cover of the battery compartment then plug in
the rechargeable battery socket.
Use the device for the rst time
1) Set the year – When the power is on, the Year number ashes in the display. Press the M Button to select the Year. Press the Time/Test Button to conrm. The Month number ashes after.
ABRIR
SYS
mmHg
DIA
mmHg
PUL /min
Auscult.
Single Cycling
MAP
Start/Stop
Time/Test
M
(3, Afib)
BASIC
+
SYS
mmHg
DIA
mmHg
PUL /min
Auscult.
MAP
Start/Stop
Time/Test
M
BASIC
+
SYS
mmHg
DIA
mmHg
PUL /min
Auscult.
Start/Stop
Time/Test
BASIC
+
2) Set the month – Use the M Button to select the
Month. Press the Time/Test Button to conrm. The Day number ashes after.
3) Set the day – Press the M Button to select the Day.
Press the Time/Test Button to conrm. The Hour number ashes after.
SYS
mmHg
DIA
mmHg
PUL /min
Auscult.
MAP
Start/Stop
Time/Test
M
BASIC
+
SYS
mmHg
DIA
mmHg
PUL /min
Auscult.
Start/Stop
Time/Test
BASIC
+
SYS
mmHg
DIA
mmHg
PUL /min
Auscult.
MAP
Start/Stop
Time/Test
M
BASIC
+
SYS
mmHg
DIA
mmHg
PUL /min
Auscult.
Start/Stop
Time/Test
BASIC
+
Loading...