Microh LED NOVA 4 User Manual

LED NOVA 4
USER MANUAL
Package Included: * LED NOVA 4 * User Manual * Power Input Cord * 5mm Allen Key
Safety Instructions
•Do not open this device, there is no user-serviceable parts inside.
• DO not look at the light source when the device is on.
• CAUTION: This unit's housing may be hot when lights are operating.
• Install this device in a location with adequate ventilation, at least 20 inch (50 cm) from adjacent surfaces.
• Do not leave any flammable material within 50 cm of this unit while operating or connected to power.
• Use a safety rope when mounting this device overhead.
• Do not hang units using only the coffin locks.
• Do not operate this device outdoors or in any location where dust, excessive heat, water, or humidity may affect it.
• Do not operate this device if the housing, lenses, or cables appear damaged.
• Do not connect this device to a dimmer or rheostat.
• ONLY connect this device to a grounded and protected circuit.
• ONLY use the hanging bracket to carry this device.
• In case of a serious operating problem, stop using immediately.
• The maximum ambient temperature is 104° F (40° C). Do not operate this device at higher temperatures.
Power Input & Power Linking
This device has an auto-switching power supply work with input voltage range of 100~240 VAC, 50/60 Hz. Link up to the maximum 4 devices at 120 VAC or 8 at 230 VAC. DO NOT exceed this number.
DMX Linking & Connection
This device can work with a DMX controller using a regular DMX serial connection. This device uses a regular DMX protocol for its DMX modes: 3, 5, 9, 48 and 53 channels.
Art-Net™ Connection
Art-Net™ is an Ethernet protocol that uses TCP/IP to transfer large amounts of DMX512 data over a large network Art-Net™ uses the EtherCon® RJ 45 connection. Art-Net™ is Designed by and Copyright Artistic Licence Holdings Ltd.
1) Disconnect the DMX controller from this device
2) Use RJ45 cables connect this device to your computer
3) You can link the other these devices with RJ45 cables or regular DMX cables.
4) You can use the Art-Net software to control and programming these devices. (Your computer needs the relevant software of Art-Net protocol.)
Cooling Fans:
This device has cooling fans controled by temperature sensor. When the device temperature inside reach about 60 C, the fans start working from a slow speed to fast as the temperature increasing.
Mounting
This device can be mounted in many orientation provided each individual device is secured through the mounting bracket. The coffin locks are for device alignment only and are not weight bearing. DO NOT hang device using only the coffin locks. Use a safety rope when mounting this device overhead.
CONTROL BOARD OPERATION
Press the Menu until one of the following displayed:
Display Function
1.DMX Address To set DMX address
2.DMX Channel To set DMX channel modes: CH 03, CH 05, CH 09, CH12, CH17
3.Dimmer Curve To set dimmer speeds: 01, 02, 03, 04
4.Sound Mode To set sound active mode and the sensitivity (Speed 000 ~ Speed 100)
5.Static Color To set static colors: Static Color R, G, B, GB, RG, RB, RGB
6.Manual Color To set user mode intensity of R, G, B separately for color mixing and strobe rate
7.Auto Program To set built-in automatic programs: Pr 01 ~ Pr 10 and speeds 000 ~100
8.Master/Slave To set Master/Slave modes
Use Up and Down button to select your desired operation, then press Enter to confirm.
DMX Addressing:
After select the "DMX Address" and press Enter, then use Up and Down to set the desired DMX address (001~512), press "Enter" again to confirm.
DMX Modes
After select the "DMX Channel" and press Enter, then use Up and Down to set the desired DMX mode (CH 03, CH 05, CH 09, CH12, CH17), press "Enter" again to confirm.
Dimmer Speed Setting:
After select the "Dimmer Curve" and press Enter, then use Up and Down to set the desired dimmer speed (01, 02, 03, 04), press "Enter" again to confirm.
Sound Mode
Entered "Sound mode", use <UP> and <DOWN> to set the sensitivity Sen 000 ~ Sen 100, press Enter to confirm.
Setting Static Color s
Entered "Static Color", you can select the desired solid color via the UP or DOW N buttons and confirm by Enter (see following graphic).
Mode:
Value: Function:
Static Color
Static color <R> Red Static color <G> Green Static color <B> Blue Static color <RG> Red + Green Static color <BG> Green + Blue Static color <RB> Red + Blue Static color <RGB> Red + Green + Blue
User Mode
This mode allows the user set intensity of R, G, B separately to get endless color mixing from the control board without DMX controller to set the device to run strobe desired. Entered user mode "Manual color", use <UP> and <DOWN> to select the " R / G / B" for Colors intensity or "S" for strobe. Use <UP> and <DOWN> to set the colors intensity values " 0 ~ 255" or Strobe speed values "000 ~ 100" (Freeze, Slow ~ Fast), then press "Enter" to confirm.
Automatic Mode
This fixture has a built-in automatic program. Entered "Auto Program" mode, use <UP> and <DOW N> to select the built-in programs "Pr01 ~ Pr -12" then press the "Enter" to confirm. Use <UP> and <DOWN> to select the operating speed of the program(Value:Speed 000 ~ Speed100, Freeze,Slow ~ Fast), press "Enter" to confirm.
Mode:
Value: Function:
Auto Program
Auto program Pr 01 R G B colors switching Auto program Pr 02 7 colors switching Auto program Pr 03 R G B colors fading Auto program Pr 04 7 colors Fading Auto program Pr 05 Color Macros Fading Auto program Pr 06 Chase 1 Auto program Pr 07 Chase 2 Auto program Pr 08 Chase 3 Auto program Pr 09 Chase 4 Auto program Pr 10 Loop above pr 01~pr 09
Master/Slave Operation
This mode allows for multiple units slave fixtures to follow a single master fixture.
1) Set the master fixture to one of the standalone operating modes: automat ic, sou nd, use r mode or static col or mode s
2) For slave units, entered the Master/Slave mode, select "Slave", press Enter.
DMX VALUES
3 Channels Mode:
CHANNEL VALUE FUNCTION
1 000-255 Red: 0% ~ 100% 2 000-255 Green: 0% ~ 100% 3 000-255 Blue: 0% ~ 100%
5 Channels Mode:
CHANNEL VALUE FUNCTION
1 000-255 Red: 0% ~ 100% 2 000-255 Green: 0% ~ 100% 3 000-255 Blue: 0% ~ 100% 4 000-255 Master Dimmer 0% ~ 100%
5
000-009 No function 010-255 Strobe : Slow ~ Fast(1~30Hz)
9 Channels Mode:
CHANNEL VALUE FUNCTION
1 000-255
Red 0% ~ 100%
Warm white 0% ~ 100%
When values 169-208 in CH. 9 are activated
2 000-255
Green 0% ~ 100%
Cool white 0% ~ 100%
When values 169-208 in
CH. 9 are activated 3 000-255 Blue 0% ~ 100% 4 000-255 Master Dimmer 0% ~ 100%
5
000-009 No function 010-255 Strobe : Slow ~ Fast(1~30Hz)
6
000-019 No Function 020-039 RED 100% / GREEN 0% ~ 100% / BLUE 0% 040-059 RED 100% ~ 0% / GREEN 100% / BLUE 0% 060-079 RED 0% / GREEN 100% / BLUE 0% ~ 100% 080-099 RED 0% / GREEN 100% ~ 0% / BLUE 100% 100-119 RED 0% ~ 100% / GREEN 0% / BLUE 100% 120-139 RED 100% / GREEN 0% / BLUE 100% ~ 0% 140-159 RED 100% / GREEN 0% ~100% / BLUE 0%~100% 160-179 RED 100%~ 0% / GREEN 100% ~ 0% / BLUE 100% 180-199 RED 100% / GREEN 100% / BLUE 100% 200-204 White Color Temprature 1 WARM 205-209 White Color Temprature 2
210-214 White Color Temprature 3 215-219 White Color Temprature 4 220-224 White Color Temprature 5 225-229 White Color Temprature 6 230-234 White Color Temprature 7 235-239 White Color Temprature 8 240-244 White Color Temprature 9 245-249 White Color Temprature 10 250-255 White Color Temprature 11
COOL
7
000-009 No function 010-032 Auto Program PR 01 R G B colors switching 033-056 Auto Program PR 02 7 colors switching 057-080 Auto Program PR 03 R G B colors fading 081-104 Auto Program PR 04 7 colors Fading 105-128 Auto Program PR 05 Color Macros Fading 129-152 Auto Program PR 06 Chase 1 153-176 Auto Program PR 07 Chase 2 177-200 Auto Program PR 08 Chase 3 201-224 Auto Program PR 09 Chase 4 225-248 Auto Program PR 10 Loop above pr 01~pr 09 249-255 Sound active
8 000-255 Speed of Auto Programs (Slow ~ Fast)
9
000-009 Default dimmer speed 010-048 Linear dimmer 049-088 Non-linear dimmer 1 089-128 Non-linear dimmer 2 129-168 Non-linear dimmer 3 169-208 WW/CW Mode ON 209-255 WW/CW Mode OFF
12 Channels Mode:
CHANNEL VALUE FUNCTION
1 000-255 Red 0% ~ 100%
LED 1
2 000-255 Green 0% ~ 100% 3 000-255 Blue 0% ~ 100% 4 000-255 Red 0% ~ 100%
LED 2 5 000-255 Green 0% ~ 100% 6 000-255 Blue 0% ~ 100% 7 000-255 Red 0% ~ 100%
LED 3
8 000-255 Green 0% ~ 100% 9 000-255 Blue 0% ~ 100%
10 000-255 Red 0% ~ 100%
LED 4 11 000-255 Green 0% ~ 100%
12 000-255 Blue 0% ~ 100%
17 Channels Mode:
CHANNEL VALUE FUNCTION
1 000-255 Red 0% ~ 100%
LED 1
2 000-255 Green 0% ~ 100% 3 000-255 Blue 0% ~ 100% 4 000-255 Red 0% ~ 100%
LED 2
5 000-255 Green 0% ~ 100% 6 000-255 Blue 0% ~ 100% 7 000-255 Red 0% ~ 100%
LED 3
8 000-255 Green 0% ~ 100% 9 000-255 Blue 0% ~ 100%
10 000-255 Red 0% ~ 100%
LED 4
11 000-255 Green 0% ~ 100% 12 000-255 Blue 0% ~ 100% 13 000-255 Master Dimmer 0% ~ 100%
14
000-009 No function 010-255 Strobe : Slow ~ Fast(1~30Hz)
15
000-009 No function 010-032 Auto Program PR 01 R G B colors switching 033-056 Auto Program PR 02 7 colors switching 057-080 Auto Program PR 03 R G B colors fading 081-104 Auto Program PR 04 7 colors Fading 105-128 Auto Program PR 05 Color Macros Fading 129-152 Auto Program PR 06 Chase 1 153-176 Auto Program PR 07 Chase 2 177-200 Auto Program PR 08 Chase 3 201-224 Auto Program PR 09 Chase 4 225-248 Auto Program PR 10 Loop above pr 01~pr 09 249-255 Sound active
16 0000-255 Speed of Auto Programs (Slow ~ Fast)
17
000-009 Default dimmer speed 010-048 Linear dimmer 049-088 Non-linear dimmer 1 089-128 Non-linear dimmer 2 129-168 Non-linear dimmer 3
169-208 WW/CW Mode ON 209-255 WW/CW Mode OFF
When CH 17 @ 169-208, WW/CW ON, CH 1 ~ CH 8 function as following:
1 000-255 Warm white 0% ~ 100%
LED 1 2 000-255 Cool white 0% ~ 100%
3 000-255 Warm white 0% ~ 100%
LED 2 4 000-255 Cool white 0% ~ 100%
5 000-255 Warm white 0% ~ 100%
LED 3 6 000-255 Cool white 0% ~ 100%
7 000-255 Warm white 0% ~ 100% LED 4
8 000-255 Cool white 0% ~ 100%
LED AR RAY :
CLEANING AND MAINTENANCE Caution: DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
The operator has to make sur e that safet y -relating and machine-technical installations are inspected by an expert after every four years in the course of an acceptance test. The operator has to make sure that safety-relating and machine-technical installations are inspected by a skilled person once a year. The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device must be tightly connected.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension, trussing).
3) The electric power cables must not show any damages, material fatigue (e.g. porous cables) or sediments. Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed.
Replacing the fuse
If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating. Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Unscrew the fuseholder on the rearpanel with a fitting screwdriver from the housing (anticlockwise). Step 2: Remove the old fuse from the fuseholder. Step 3: Install the new fuse in the fuseholder. Step 4: Replace the fuseholder in the housing and fix it.
TECHNICAL SPECIFICATIONS:
Power supply: 100~240 V AC, 50/60 Hz ~ Power consumption: 120 W DMX control channels: 3,5,9, 12 or 17 chs DMX512 connection: 3-pin XLR Sound-control: via built-in microphone LED type: 30 W COB Tri-color RGB Number of LEDs: 4 Beam angle: 30° Dimensions (LxWxH): 425 x 187 x 163 mm Weight: 4 kg Maximum ambient temperature Ta: 40° Maximum housing temperature TC (steady state): 80° C Min. distance from flammable surfaces: 0.5 m Min. distance to lighted object: 0.1 m Fuse: T 2 A, 250 V
1 2 3 4
Loading...