Micro Dynamics Mega 30V Maintain Manual

Thermal Compensator
Maintain Manual
NOTICE
This manual shall be carefully reviewed by relative operators of this machine before operation.
In the case of any trouble or accidents caused as a result of disregarding this manual, InnoServ as the manufacturer will not be held responsible.
If you find any questions about this manual please do not hesitate to contact us.
The contents of this manual are explanations of operation only and are not meant as an explanation of warranty.
The warranty mentioned herein states that the manufacturer will supply replacement parts at no charge during the warranty period should any defects be found. The warranty will not cover any economic losses or damage by the purchaser.
Date: February 25, 2019 (Original Instructions) Revision: 001
Thermal Compensator Maintain 2019-02-25 Ben.Lu
2 / 8
Index
1 Thermal Compensator Error Message ...................................... 3
2 Temperature Sensor Position ..................................................... 6
2-1 Temperature Module Position .............................................. 6
2-2 Temperature Sensor Position ................................................ 7
Thermal Compensator Maintain 2019-02-25 Ben.Lu
3 / 8
1 Thermal Compensator Error Message
Error message 1
Question
1. Unable to read temperature: The connection between the NC and the PLC controller is
abnormal.
Solution
1. Restart machine.
2. Check if the network cable between the NC and PLC controller is normal.
Thermal Compensator Maintain 2019-02-25 Ben.Lu
4 / 8
Error message 2
Question
1. Temperature out of range: Operating range of temperature over -50~200.
2. The numbers 1~8 are 1~8 sensor.
Solution
1. Check if the temperature of the measurement position exceeds the operating
temperature range. If it is. The thermal compensator stops working.
2. If the temperature is within the normal operating temperature range then replace the
temperature sensor.
Thermal Compensator Maintain 2019-02-25 Ben.Lu
5 / 8
Error message 3
Question
1. Temperature value interference: The temperature sensor has noise.
2. The numbers 1~8 are 1~8 sensor.
Solution
1. Check the machine for ground.
2. Replace the temperature sensor.
Thermal Compensator Maintain 2019-02-25 Ben.Lu
6 / 8
2 Temperature Sensor Position
2-1 Temperature Module Position
Pneumatic plate
Headstock side frame
Thermal Compensator Maintain 2019-02-25 Ben.Lu
7 / 8
2-2 Temperature Sensor Position
Base
T1 = 4718-07-010100, PT100 Sensor Cable 3m
Column Top
T2 = 4718-07-010000, PT100 Sensor Cable 2m
Thermal Compensator Maintain 2019-02-25 Ben.Lu
8 / 8
Column Right Low
T3 = 4718-07-010100, PT100 Sensor Cable 3m
Note: This temperature sensor is not installed on MEGA30V machine.
Spindle Head
T4 = 4718-07-010100, PT100 Sensor Cable 3m
T5 = 4718-07-009900, PT100 Sensor Cable 0.5m
T6 = 4718-07-003900, PT100 Sensor Cable 0.7m
T7 = 4718-07-003800, PT100 Sensor Cable 1m
T8 = 4718-07-003800, PT100 Sensor Cable 1m