MICREL SY10E451, SY100E451 Datasheet

6-BIT REGISTER DIFFERENTIAL DATA CLOCK
SY10E451
SY100E451
FEATURES
1100MHz min. toggle frequency
Extended 100E VEE range of –4.2V to –5.5V
Differential inputs: data and clock
VBB output for single-ended use
Asynchronous Master Reset
Fully compatible with industry standard 10KH,
100K ECL levels
Internal 75K input pulldown resistors
Fully compatible with Motorola MC10E/100E451
Available in 28-pin PLCC package
BLOCK DIAGRAM
D
0
D
0
D
R
D
1
D
1
D
R
D
2
D
2
D
R
D
3
D
3
D
R
D
4
D
4
D
R
0
Q
Q
1
Q
2
Q
3
Q
4
DESCRIPTION
The SY10/100E451 offer six D-type flip-flops with single­ended outputs and differential data and clock inputs, designed for use in new, high-performance ECL systems. The registers are triggered by the rising edge of the CLK input.
PIN CONFIGURATION
5
4
3
4
CLK
V
BB
CLK
V
EE
MR
NC
D
5
D
D
D
25
24 23 22 21 20 19 26 27 28
1 2 3
0
4
TOP VIEW
PLCC
J28-1
5 6 7 8 9 10 11
0
1
1
D
D
D
3
CCO
D
D
D
V
18
Q
5
17
Q
4
16
V
CC
15
Q
3
14
V
CCO
13
Q
2
12
Q
1
2
D
0
2
D
Q
CCO
V
D D
CLK CLK
MR
V
BB
5 5
D
Q
5
R
PIN NAMES
Pin Function
D0–D5 + Data Input D0–D5 – Data Input CLK + Clock Input CLK – Clock Input MR Master Reset Input VBB VBB Output Q0–Q5 Data Outputs
CCO VCC to Output
V
Rev.: C Amendment: /1
1
Issue Date: February, 1998
Micrel
SY100E451
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°CTA = 25°CTA = +85°C
Symbol Parameter Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit Condition
BB Output Reference Voltage V
V
10E –1.38 —–1.27 –1.35 —–1.25 –1.31 —–1.19
100E –1.38 —–1.26 –1.38 —–1.26 –1.38 —–1.26
IIH Input HIGH Current ——150 ——150 ——150 µA
EE Power Supply Current mA
I
10E 84 101 84 101 84 101
100E 84 101 84 101 97 116
CMR Common Mode Range –2.0 —–0.4 –2.0 —–0.4 –2.0 —–0.4 V 1
V
NOTE:
CMR is referenced to the most psitive side of the differential input signal. Normal operation is obtained when the "HIGH" input is within the VCMR
1. V range and the input swing is greater than VPP(min) and < 1V.
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
SY10E451
TA = 0°CTA = +25°CTA = +85°C
Symbol Parameter Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit Condition
fMAX Max. Toggle Frequency 1100 1400 1100 1400 1100 1400 MHz
PLH Propagation Delay to Output ps
t tPHL CLK (Diff) 475 650 800 475 650 800 475 650 800
CLK (SE) 425 650 850 425 650 850 425 650 850
MR 425 600 850 425 600 850 425 600 850 tS Set-up Time, D 150 –100 150 –100 150 –100 ps — tH Hold Time, D 250 100 250 100 250 100 ps — VPP (AC) Minimum Input Swing 150 ——150 ——150 ——mV 1 tRR Reset Recovery Time 750 600 750 600 750 600 ps
PW Minimum Pulse Width 400 ——400 ——400 ——ps
t
CLK, MR tskew Within-Device Skew 100 ——100 ——100 ps 2
r Rise/Fall Time 275 450 800 275 450 800 275 450 800 ps
t tf 20% to 80%
NOTES:
1. Minimum input voltage for which AC parameters are guaranteed.
2. Within-device skew is defined as identical transitions on similar paths through a device.
PRODUCT ORDERING CODE
Ordering Package Operating
Code Type Range
SY10E451JC J28-1 Commercial SY10E451JCTR J28-1 Commercial SY100E451JC J28-1 Commercial SY100E451JCTR J28-1 Commercial
2
Loading...
+ 2 hidden pages