MICREL SY10E212, SY100E212 Datasheet

3-BIT SCANNABLE REGISTER
SY10E212
SY100E212
FEATURES
Scannable version E112 driver
Extended 100E VEE range of –4.2V to –5.5V
1025ps max. CLK to Output
Dual differential outputs
Master Reset
Internal 75K input pull-down resistors
100K ECL levels
Fully compatible with Motorola MC10E/100E212
Available in 28-pin PLCC package
BLOCK DIAGRAM
S-OUT Q
D
Q
D
2
D
Q
D
1
2b
Q
2a
Q
2a
Q
2b
Q
1b
Q
1a
Q
1a
Q
1b
DESCRIPTION
The SY10/100E212 are scannable registered ECL drivers typically used as fan-out memory address drivers for ECL cache driving. In a VLSI array-based CPU design, use of the E212 allows the user to conserve array output cell functionality and also output pins.
The input shift register is designed with control logic which greatly facilitates its use in boundary scan applications.
PIN CONFIGURATION
2b
CCO
Q2a
V
S-OUT
Q
18
Q2b
17
Q2a
16
VCC
15
Q1b
14
Q1a
13
Q1b
12
Q1a
LOAD
CLK
D
VEE
D1 D0
S-IN
NC
SHIFT
MR
25
24 23 22 21 20 19
26 27 28
2
1 2 3 4
TOP VIEW
PLCC
J28-1
567891011
D
S-IN
LOAD
SHIFT
CLK
MR
NC
CCO
Q0b
Q0a
Q0a
Q
D
Q
0
0b
Q
0a
Q
0a
Q
0b
V
Q0b
VCCO
PIN NAMES
Pin Function
D0 – D2 Data Inputs S-IN Scan Input LOAD LOAD/HOLD Control SHIFT Scan Control CLK Clock MR Master Reset S-OUT Scan Output Q[0:2]a, Q[0:2]b True Outputs Q[0:2]a, Q[0:2]b Inverting Outputs
CCO VCC to Output
V
Rev.: C Amendment: /1
1
Issue Date: February, 1998
SY10E212
Micrel
SY100E212
TRUTH TABLE
LOAD SHIFT MR Mode
L L L Load H L L Hold X H L Shift X X H Reset
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°CTA = +25°CTA = +85°C
Symbol Parameter Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit Condition
IIH Input HIGH Current 150 150 150 µA—
EE Power Supply Current mA
I
10E 80 96 80 96 80 96
100E 80 96 80 96 92 110
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°CTA = +25°CTA = +85°C
Symbol Parameter Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit Condition
PLH Propagation Delay to Output ps
t tPHL CLK 575 800 1025 575 800 1025 575 800 1025
MR 575 800 1025 575 800 1025 575 800 1025 CLK to S-OUT 575 800 1025 575 800 1025 575 800 1025
t
S Set-up Time ps
D 175 25 175 25 175 25 — SHIFT 150 –50 150 –50 150 –50 — LOAD 225 50 225 50 225 50 — S-IN 150 –50 150 –50 150 –50
H Hold Time ps
t
D 250 25 250 25 250 25 — SHIFT 300 100 300 100 300 100 — LOAD 225 0 225 0 225 0
S-IN 300 100 300 100 300 100 — tRR Reset Recovery 600 350 600 350 600 350 ps — tskew Within-Device Skew 100 100 100 ps 1 tskew Within-Gate Skew 50 50 50 ps 2
r Rise/Fall Times 275 425 650 275 425 650 275 425 650 ps
t tf 20% to 80%
NOTES:
1. Within-device skew is defined as identical transitions on similar paths through a device.
2. Within-gate skew is defined as the difference in delays between various outputs of a gate when driven from the same input.
PRODUCT ORDERING CODE
Ordering Package Operating
Code Type Range
SY10E212JC J28-1 Commercial SY10E212JCTR J28-1 Commercial SY100E212JC J28-1 Commercial SY100E212JCTR J28-1 Commercial