MICREL SY10E142, SY100E142 Datasheet

9-BIT SHIFT REGISTER
SY10E142
SY100E142
FEATURES
700MHz min. shift frequency
Extended 100E V
EE range of –4.2V to –5.5V
9 bits wide for byte-parity applications
Asynchronous Master Reset
Dual clocks
Fully compatible with industry standard 10KH,
100K ECL levels
Fully compatible with Motorola MC10E/100E142
Available in 28-pin PLCC package
BLOCK DIAGRAM
S-IN
D
D
0
1
1 DQ 0
1 0
DQ
Q0
Q1
DESCRIPTION
The SY10/100E142 are high-speed 9-bit shift registers designed for use in new, high-performance ECL systems. The E142 can accept serial or parallel data to be shifted out in one direction as both serial and parallel outputs. The nine inputs, D
0-D8, accept parallel input data, while S-IN
accepts serial input data.
The SEL (Select) control pin serves to determine the mode of operation, either SHIFT or LOAD. The shift direction is from bit 0 to bit 8. The input data has to meet the set-up time before being clocked into the nine input registers on the rising edge of CLK1 or CLK2. Shifting is also performed on the rising edge of either CLK1 or CLK2. The MR (Master Reset) control signal asynchronously resets all nine registers to a logic LOW when a logic HIGH is applied to MR.
The E142 is designed for applications such as diagnostic scan registers, parallel-to-serial conversions and is also suitable for byte-wide parity.
PIN CONFIGURATION
D2
D3
D4
D5
D6
D7
D8
SEL
CLK1 CLK2
MR
SEL
1 0
1 0
1 0
1 0
1 0
1 0
1 0
DQ
DQ
DQ
DQ
DQ
DQ
DQ
Q2
Q3
Q4
Q5
Q6
Q7
Q8
MR CLK CLK
V
S-IN
EE
D D
26
1
27
2
28
1
2
0
3
1
4
PIN NAMES
Pin Function
D0-D8 Parallel Data Inputs S-IN Serial Data Input SEL Mode Select Input
D
25 24 23 22 21 20 19
PLCC
TOP VIEW
J28-1
567891011
3
4
2
D
D
D
D
CCO
V
V
D
Q
18
Q
7
17
Q
6
16
V
CC
Q V Q Q
5
CCO
4 3
15 14 13 12
1
0
2
Q
Q
Q
8
5
CCO
6D7
8
CLK1, CLK2 Clock Inputs MR Master Reset Q0-Q8 Data Outputs
CCO VCC to Output
V
Rev.: C Amendment: /1
1
Issue Date: February, 1998
SY10E142
Micrel
SY100E142
TRUTH TABLE
SEL MODE
L LOAD H SHIFT
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°CTA = +25°CTA = +85°C
Symbol Parameter Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit Condition
IIH Input HIGH Current 150 150 150 µA— I
EE Power Supply Current mA
10E 120 145 120 145 120 145
100E 120 145 120 145 138 165
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°CTA = +25°CTA = +85°C
Symbol Parameter Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit Condition
fSHIFT Max. Shift Frequency 700 900 700 900 700 900 MHz — tPLH Propagation Delay to Output ps
tPHL CLK 600 800 1000 600 800 1000 600 800 1000
MR 600 800 1000 600 800 1000 600 800 1000
S Set-up Time ps
t
D 50 –100 50 –100 50 –100 — SEL 300 150 300 150 300 150
H Hold Time ps
t
D 300 100 300 100 300 100 — SEL 75 –150 75 –150 75 –150
tRR Reset Recovery Time 900 700 900 700 900 700 ps
PW Minimum Pulse Width 400 400 400 ps
t
CLK, MR tskew Within-Device Skew 75 75 75 ps 1 t
r Rise/Fall Time 300 525 800 300 525 800 300 525 800 ps
tf 20% to 80%
NOTE:
1. Within-device skew is defined as identical transitions on similar paths through a device.
PRODUCT ORDERING CODE
Ordering Package Operating
Code Type Range
SY10E142JC J28-1 Commercial SY10E142JCTR J28-1 Commercial SY100E142JC J28-1 Commercial SY100E142JCTR J28-1 Commercial
2