FEATURES
Operates from a single +5V supply
Differential PECL outputs
Function and pinout compatible with Fairchild F100K
Available in 24-pin CERPACK and 28-pin PLCC
packages
BLOCK DIAGRAM
E
Q
D
0
D
1
D
2
D
3
D
4
D
5
0
Q
0
Q
1
Q
1
Q
2
Q
2
Q
3
Q
3
Q
4
Q
4
Q
5
Q
5
SY100S391
DESCRIPTION
The SY100S391 is a hex TTL-to-PECL translator for converting TTL logic levels to 100K logic levels. The unique feature of this translator is the ability to do this translation using only one +5V supply. The differential outputs allow each circuit to be used as an inverting/non-inverting translator, or as a differential line driver. A common enable (E), when LOW, holds all inverting outputs HIGH and all non-inverting inputs LOW.
The SY100S391 is ideal for those mixed PECL/TTL applications which only have a +5V supply available. When used in the differential mode, the S391, due to its high common mode rejection, overcomes voltage gradients between the TTL and PECL ground systems.
PIN CONFIGURATIONS
D
GND TTL
GND PECL
GNDS
GND PECL
D
0
0
D1D
Q
GNDS
2
12 13 14
Top View
15 16
E
17
3
18
PLCC J28-1
1911201021922823724
5
5
4
D
D
Q
GNDS
1
0
Q
Q1Q
5
6
Q
2
Q
2
V
CCA
1
V
CC
V
CC
2 2
Q
3
2
3
Q
25
4
Q4Q5Q
3
D
E
GND PEC
2
GND TTL
D
GND PECL
D
PIN NAMES
Pin Function
D0 — D5 Data Inputs (TTL) Q0 — Q5 Data Outputs (PECL) Q0 — Q5 Inverting Data Outputs (PECL)
4
1
D
5
2
Q
5
3
Top View
Q
5
Q
4
Q
4
Flatpack
4
F24-1
5 6
7248239221021112012
3
3
Q
Q
CC
V
CCA
V
2
Q
D
18 17 16 15 14 13
2
Q
1
D
0
Q
0
Q
0
Q
1
Q
1
E Enable Input (TTL)
CCA VCCO for ECL Outputs
V
Rev.: G Amendment: /0
19
1
Issue Date: July, 1999
Micrel
SY100S391
TRUTH TABLE
Inputs Outputs
Dn EQn Qn
HHH L LHL H HLL H LLL H
NOTE:
1. H = High Voltage Level, L = Low Voltage Level
GUARANTEED OPERATING CONDITIONS
Symbol Rating Value Unit
T
A Operating Temperature ˚C
Commercial 0 to +85
CC Supply Voltage +4.5 to +5.5 V
V
NOTE:
1. Do not exceed.
LOGIC SYMBOL
D
0
E
Q0 Q0Q1 Q1Q2 Q2Q3 Q3Q4 Q4Q5 Q
ABSOLUTE MAXIMUM RATINGS
Symbol Rating Value Unit
(1)
TTL Input Voltage TTL Input Current PECL Output Current 50 V
V
Tstore Storage Temperature –65 to +150 ˚C T
J Max. Junction Temp. ˚C
NOTES:
1. Permanent device damage may occur if ABSOLUTE MAXIMUM RATINGS
are exceeded. This is a stress rating only and functional operation is not implied at conditions other than those detailed in the operational sections of this data sheet. Exposure to ABSOLUTE MAXIMUM RATlNG conditions for extended periods may affect device reliability.
2. Either voltage limit or current limit is siffucient to protect inputs.
D
1
D
2
D
3
(2)
(2)
D
(1)
0.5 to +7.0 V
30 to +5.0 V
(DC Output HIGH)
CC Pin Potential to –0.5 to +7.0 V
Ground Pin
Ceramic +175 Plastic +150
4
D
5
5
TTL-TO-PECL DC ELECTRICAL CHARACTERISTICS
(1)
VCC = +5.0V ± 10%; GND = 0V
Symbol Parameter Min. Typ. Max. Unit Condition
VOH Output HIGH Voltage VCC –1025 VCC –955 VCC –870 mV VIN = VIH (Max.) or VIL (Min.) VOL Output LOW Voltage VCC –1890 VCC –1705 VCC –1620 Loading with 50 to VCC –2V
VOHC Output HIGH Voltage VCC –1035 —— mV VIN = VIH (Min.) or VIL (Max.)
Corner Point High Loading with 50 to VCC –2V
VOLC Output LOW Voltage ——VCC –1610 mV
Corner Point Low VIH Input HIGH Voltage 2.0 5.0 V Over VTTL, VEE, TA Range VIL Input LOW Voltage 0 0.8 V Over VTTL, VEE, TA Range IIH Input HIGH Current ——10 µAVIN = +2.7V
Breakdown Current ——100 µAVIN = +5.5V, VCC = Max. IIL Input LOW Current Dn ——–0.8 mA VIN = +0.5V
E –4.2 VCD Input Clamp Diode Voltage ——–1.2 V IIN = –18mA ICC VCC Supply Current 25 69 mA Inputs Open
NOTE:
1. The specified limits represent the "worst case" value for the parameter. Since these values normally occur at the temperature extremes, additional noise immunity and guardbanding can be achieved by decreasing the allowable system operating ranges. Conditions for testing shown in the tables are chosen to guarantee operation under "worst case" conditions.