MICREL SY100S364 Datasheet

16-INPUT MULTIPLEXER
SY100S364
FEATURES
Max. propagation delay of 1300ps
IEE min. of –63mA
Industry standard 100K ECL levels
Extended supply voltage option:
VEE = –4.2V to –5.5V
noise immunity
Internal 75K input pull-down resistors
70% faster than Fairchild
40% lower power than Fairchild
Function and pinout compatible with Fairchild F100K
Available in 24-pin CERPACK and 28-pin PLCC
packages
BLOCK DIAGRAM
I
15
I
14
I
13
I
12
I
11
I
10
I
9
DESCRIPTION
The SY100S364 is a 16-input multiplexer designed for use in high-performance ECL systems. The four Data Select inputs (S0, S1, S2, S3) determine the bit from the 16 inputs (In) that will be passed on to the output as shown in the Truth Table. The output data polarity is the same as the input. The inputs on the device have 75K pull-down resistors.
PIN CONFIGURATIONS
I12
VEES
Top View
PLCC J28-1
I2
VEES
I11
I10
I9
5
6
I8
4 3
Z V
CCA
2 1
VCC VCC
28 27
I7
2618
6
I
25
1
EE
I5
I3
I4
S3S2S
15
S0I
V
19
1
I
0
I
1
2 3
I
2
I
3
I
4
I
5
Top View
Flatpack
4
F24-1
5 6
18 17 16 15 14 13
I
14
I
13
I
12
I
11
I
10
I
9
7248239221021112012
I15 S0
VEE
VEES
S1
I14
I13
12 13 14 15 16 17
S2 S3
1911201021922823724
I1
I0
7
I
8
S
3
I
7
I
6
S
2
I
5
I
4
S
1
I
3
I
2
S
0
I
1
I
0
Z
1
6
I
I
CC
V
Rev.: G Amendment: /0 Issue Date: July, 1999
CCA
V
8
Z
I
Micrel
SY100S364
PIN NAMES
Pin Function
I0 – I15 Data Inputs S0 – S3 Select Inputs Z Data Output VEES VEE Substrate
CCA VCCO for ECL Outputs
V
TRUTH TABLE
(1)
Select Inputs Output
S0 S1 S2 S3 Z
L LLL I
H LLL I1
LHLL I2
HHLL I3
LLHL I4
HLHL I5
LHHL I6
HHHL I7
LLLHI8
HLLH I9
LHLHI10
HHLHI11
LLHHI12
HLHHI13
L HHH I14
H HHH I15
NOTE:
1. H = HIGH Voltage Level
L = LOW Voltage Level
0
DC ELECTRICAL CHARACTERISTICS
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
Symbol Parameter Min. Typ. Max. Unit Condition
IH Input HIGH Current µAVIN = VIH (Max.)
I
In ——200 S0, S1 ——200 S2, S3 ——200
EE Power Supply Current –63 –45 –30 mA Inputs Open
I
AC ELECTRICAL CHARACTERISTICS
CERPACK
VEE = –4.2V to –5.5V unless otherwise specified; VCC = VCCA = GND
TA = 0°CTA = +25°CTA = +85°C
Symbol Parameter Min. Max. Min. Max. Min. Max. Unit Condition
PLH Propagation Delay 400 1400 400 1400 400 1400 ps
t tPHL I0 – I15 to Output
t
PLH Propagation Delay 400 1900 400 1900 400 1900 ps
tPHL S0, S1 to Output
PLH Propagation Delay 400 1700 400 1700 400 1700 ps
t tPHL S2, S3 to Output
TLH Transition Time 300 900 300 900 300 900 ps
t tTHL 20% to 80%, 80% to 20%
2
Loading...