MICREL SY10E116, SY100E116 Datasheet

QUINT DIFFERENTIAL LINE RECEIVER
SY10E116
SY100E116
FEATURES
450ps max. Propagation Delay
Extended 100E V
EE range of –4.2V to –5.5V
VBB output for single-ended reception
Fully compatible with industry standard 10KH,
100K I/O levels
Internal 75K input pulldown resistors
Available in 28-pin PLCC package
BLOCK DIAGRAM
D0 D0 D1 D1 D2 D2
Q0 Q0 Q1 Q1 Q2 Q2
DESCRIPTION
The SY10/100E116 are quint differential line receivers designed for use in new, high-performance ECL systems. These devices have emitter-follower outputs and an internally generated reference supply (V ended reception.
Active current sources combined with Micrel-Synergy’s ASSET™ technology provide the receivers with excellent common mode noise rejection.
The receiver design features clamp circuitry to cause a defined output state if both the inverting and non-inverting inputs are left open; in this case the Q output goes LOW, while the Q output goes HIGH.
If both inverting and non-inverting inputs are at equal potential, the receiver does
not go
to a defined state, but rather shares current in normal differential amplifier fashion, producing output voltage levels midway between HIGH and LOW.
The VBB output is intended for use as a reference voltage for single-ended reception of ECL signals to that device only. When using VBB for this purpose, it is recommended that VBB is decoupled to VCC via a 0.01 µF capacitor.
For higher bandwidth, please refer to the SY10/100E416 device.
BB) for single-
D3 D3 D4 D4
VBB
Q3 Q3 Q4 Q4
PIN NAMES
Pin Function
D0, D0-D4, D4 Differential Input Pairs Q0, Q0-Q4, Q4 Differential Output Pairs VBB Reference Voltage Output
CCO VCC to Output
V
PIN CONFIGURATION
3
4
4
D
D
D
24 23 22 21 20 19
25
D
D
V V
26
3
27
D
2
28
2
EE
1
BB
2
D D
3
0 0
4
56789
1
D
PLCC
TOP VIEW
J28-1
1
D
CCO
V
CCO
V
0
Q
4
Q
0
Q
4
Q
10 11
CCO
V
CCO
V
1
Q
18
Q
3
17
Q
3
16
V
CC
15
Q
2
14
Q
2
13
V
CCO
12
Q
1
Rev.: E Amendment: /0
1
Issue Date: November, 1998
SY10E116
Micrel
SY100E116
LOGIC EQUATION
Qn = Dn
DC ELECTRICAL CHARACTERISTICS
VEE = VEE(Min.) to VEE(Max.); VCC = VCCO = GND
TA = –40°CTA = 0°CTA = +25°CTA = +85°C
Symbol Parameter Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit
BB Output Reference V
V
Voltage 10E –1.43 —–1.30 –1.38 —–1.27 –1.35 —–1.25 –1.31 —–1.19
100E –1.43 —–1.26 –1.38 —–1.26 –1.38 —–1.26 –1.38 —–1.26
IIH Input HIGH Current ——200 ——200 ——200 ——200 µA IEE Power Supply Current mA
10E 29 35 29 35 29 35 29 35
100E 29 35 29 35 29 35 33 40
VPP (DC) Input Sensitivity
CMR Common Mode Range
V
NOTES:
1. VPP is the minimum differential input voltage required to assure full ECL levels are present at the outputs.
2. VCMR is referenced to the most positive side of the differential input signal. Normal operation is obtained when the "HIGH" input is within the VCMR range and the input swing is greater than VPP (min.) and <1V.
(1)
150 ——150 ——150 ——150 ——mV
(2)
–2.0 —–0.6 –2.0 —–0.6 –2.0 —–0.6 –2.0 —–0.6 V
AC ELECTRICAL CHARACTERISTICS
VEE = VEE(Min.) to VEE(Max.); VCC = VCCO = GND
TA = –40°CTA = 0°CTA = +25°CTA = +85°C
Symbol Parameter Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit
PLH Propagation Delay to ps
t tPHL Output D 150 300 500 200 300 450 200 300 450 200 300 450
D (S.E.) 150 300 550 150 300 500 150 300 500 150 300 500
VPP (DC) Input Sensitivity
skew Within-Device Skew
t
Dn to Qn, Qn
tskew Duty Cycle Skew
tPLH – tPHL
tr Rise/Fall Time 250 375 625 275 375 575 275 375 575 275 375 575 ps tf 20% to 80%
NOTES:
1. Minimum input swing for which AC parameters are guaranteed.
2. Within-device skew is defined as identical transitions on similar paths through a device.
3. Duty cycle skew is defined only for differential operation when the delays are measured from the cross point of the inputs to the cross point of the outputs.
(1)
(3)
150 150 150 ——150 ——150 ——mV
(2)
50 ——50 ——50 ——50 ps
±10 ——±10 ——±10 ——±10 ps
PRODUCT ORDERING CODE
Ordering Package Operating
Code Type Range
SY10E116JC J28-1 Commercial SY10E116JCTR J28-1 Commercial SY100E116JC J28-1 Commercial SY100E116JCTR J28-1 Commercial
Ordering Package Operating
Code Type Range
SY10E116JI J28-1 Industrial SY10E116JITR J28-1 Industrial SY100E116JI J28-1 Industrial SY100E116JITR J28-1 Industrial