Mic 98610, 98620, 98621 Operation Manual

Page 1
OPERATIONMANUAL
Thermo-Hygro Anemometer
98610/98620/98621
FEATURES
Contacted temperature measurement. Relative humidity/Web Bub/Dew Point (98620/98621) Heat Index/WBGT(98621 only) Data hold/Maximum/Average functions. Auto power off function(15 minutes). Quick response and high accuracy Low battery indication
MATERIAL SUPPLIED
Meter Battery(CR2032 battery included) Operation manual Box
Page 2
LCD DISPLAY
MAX
MIN
AVG
MOIST
TEMP AIR T
R H I
DPWB WNCL
REL
REC
BFT FPM/H KMH m/s KNT
HOLD
BAT
%
KEY FUNCTION
POWER: Max/Min/Average(5s’10s’13s’) HOLD: Data hold mode/wind speed unit/Temp. unit MODE: WNCL/Temp.(98610)/RH/DP/WB(98620/98621) HI/WBGT(98621 only)
OPERATION
(1)Power On/Off With meter off, short press POWER to turn on the meter. To turn the meter off, long press POWER to turn off. The meter will also turn off automatically after 15 minutes if no action is taken.
(2)Maximum and Minimum mode With meter on, press POWER button “MAX” icon will appear on the display with temp. reading. Press POWER again LCD appear “AVG” icon and each press goes from 5sec,10sec to13sec average. The meter will circularly appear MAX ,5sec AVG, 10sec AVG,13sec AVG reading on the display. Note:5sec,10sec,13sec icon only appear for a sec then start measure.
MAX
m/s
↑
AVG
m/s
←
→
m/s
AVG
m/s
↓
AVG
←
m/s
Page 3
(3)Data Hold Press HOLD button to freeze the displayed reading. The ‘HOLD’ icon and the held reading will appear on the display. Press the HOLD button again, the meter will return to the normal measurement.
HOLD
m/s
(4)Auto Power OFF The meter will shut off automatically after approximately 15 minutes, if no action is taken. To disable auto power off, when meter off press HOLD+POWER button, “n” icon will appear on the LCD. The meter will return to normal measurement
(5)Change wind speed unit When meter is under air flow measurement, long press HOLD button to change unit from m/s→KMH→M/H→FPM→ BFT→KNT and back to m/s.
(6)Select Temp. mode Short press MODE button to circularly appear m/s→WNCL→ Temp.→Humidity→Heat Index→Dew Point→Wet Bulb→WBGT and back to m/s.
(7)Change Temp. unit Under WNCL,Temp.,HI,DP,WB and WBGT mode, short press HOLD button to change Temp. unit from °C/°F.
TROUBLE SHOOTING
Er1:Disconnection of sensor/Low battery to connect sensor. Er2:Out of range
Page 4
SPECIFICATION
Spec./Model no.
98610
98620
98621
Temp. range
-15.0~50.0°C(5~122°F)
Resolution
0.1°C
Accuracy
±1ºC
Air Velocity range
0.4~25m/s,80~4920ftm
Accuracy
±3%of FS
Wind Unit
m/s,ftm,kmh,mph,knot,BFT
RH% range
N/A
5.0~95.0%
Resolution
N/A
0.1%
Accuracy
N/A
±3%RH(at25ºC
10~90%),others 5%
Dew point/Web bulb/ Windchill
N/A
YES
Heat index/WBGT
N/A
YES
HOLD
YES
MAX/MIN/AVG
YES
Recall/Reset
YES
Power
CR2032 x1 pc
LCD display
28 x 14mm
Operating Temp.&RH
0~50°C(32~122°F),<80%RH
Meter size
152 x 40 x 18mm
BATTERY REPLACEMENT
Use a coin to remove the battery compartment cover on the rear of the meter. Replace the CR-2032 lithium battery; install the new battery face up (+) in the battery compartment.