MHM QC 4669 MW, QC 4646 MW, QC 4170 MW, QC 70100 MW, QC 8044 MW Operating Instruction

...
Operating Instruction MHM Flash Cures
Operating instructions MHM Flash Cures.docx Page 1 of 17
OPERATING INSTRUCTIONS
(Original instructions)
MHM Flash Cures type: QC 4646 MW, QC 4355 MW, QC 4661 MW, QC 4669 MW, QC 4170 MW, QC 5069 MW,
QC 70100 MW, QC 8044 MW, QC 6080 MW,
QC 4170 HTL, QC 70100 HTL
©2018 Machines Highest Mechatronic GmbH, Erl, Austria
Operating Instruction MHM Flash Cures
Operating instructions MHM Flash Cures.docx Page 2 of 17
Preface
Dear Customer,
congratulations and thank you for choosing the MHM Flash Cure. The Flash Cure is designed to provide the highest standards of performance and reliability during its guaranteed long operating life. Highly innovative and precise MHM technology provides a combination of the finest built quality along with optimal safety. We trust that these Operating Instructions will assist you in becoming familiar with the safe and efficient operation of the Flash Cure.
Important Note:
Due to our policy of continuous improvement, we reserve the right to change specifications without prior notice. Therefore, certain individual fittings and components may differ slightly from the model detailed in this document. For any further questions regarding your MHM Flash Cure, please contact the MHM service team.
Wishing you every success with your future production.
Machines Highest Mechatronic GmbH
Important Advice Regarding These Operating Instructions
These Operating Instructions form an integral part of the MHM Flash Cure and must be made available to all authorized personnel at all times. No particular sections or pages must be removed from these Operating Instructions, and any missing sections or pages should be replaced immediately, in particular with regard to section “Safety Instructions”.
These Operating Instructions are subject to international copyright and may not be reproduced and/or revised without our prior written approval.
©2018 Machines Highest Mechatronic GmbH, Erl, Austria. (All rights reserved).
Published by: Machines Highest Mechatronic GmbH
Muehlgraben 43a A-6343 Erl / AUSTRIA
Contact details: Telephone:+43 (0) 5373 – 76080-18
Mobile: +43 (0) 664 – 8151380 E-mail: service@mhm.at
Erl, December 2018
Operating Instruction MHM Flash Cures
Operating instructions MHM Flash Cures.docx Page 3 of 17
Content:
Preface .................................................................................................................................................. 2
Important Advice Regarding These Operating Instructions ................................................................ 2
1. Introduction .................................................................................................................................. 4
2. Safety Instructions........................................................................................................................ 4
2.1. Description of Key Words and Symbols in the Operating Instructions ................................ 4
2.2. Qualification of Operating and Service Staff ........................................................................ 4
2.3. Safety Instructions for the Operating Staff............................................................................ 5
2.4. Additional Risks .................................................................................................................... 5
2.5. Other Valid Rules and Regulations ....................................................................................... 5
3. Intended usage of the machine ..................................................................................................... 5
4. Data .............................................................................................................................................. 6
4.1. Serial Number and Year of Manufacture .............................................................................. 6
4.2. MHM part numbers ............................................................................................................... 6
4.3. Dimensions ............................................................................................................................ 7
4.4. Specifications ........................................................................................................................ 7
5. Installation .................................................................................................................................... 8
5.1. Ambient Conditions .............................................................................................................. 8
5.2. Electrical requirements .......................................................................................................... 9
5.3. Start signal ............................................................................................................................. 9
5.4. Height adjustment.................................................................................................................. 9
6. Design ........................................................................................................................................ 10
6.1. Component description........................................................................................................ 10
6.2. Control panel ....................................................................................................................... 11
7. Operating the unit....................................................................................................................... 12
7.1. Normal operation ................................................................................................................. 12
7.2. Overheat protection ............................................................................................................. 13
7.3. Programming the Flash Cure ............................................................................................... 13
7.4. Changing lamps ................................................................................................................... 15
8. Maintenance of the Flash Cure .................................................................................................. 16
9. Accessories................................................................................................................................. 16
9.1. Temperature sensor ............................................................................................................. 16
9.2. Photocell .............................................................................................................................. 16
9.3. Footswitch ........................................................................................................................... 16
10. Terms of the Guarantee ........................................................................................................... 17
11. Support, Customer Service and Hotline .................................................................................. 17
Operating Instruction MHM Flash Cures
Operating instructions MHM Flash Cures.docx Page 4 of 17
1. Introduction
The MHM Flash Cure is a microprocessor controlled unit, which uses carbon infrared emitters to rapidly cure plastisol or water based inks. The height of the unit above the pallet is adjustable and the heat output and drying time can be precisely controlled. In order to ensure a long emitter life the lamps in the zone or zones being used are operated from a pre-determined stand-by level and are switched from that level to the output level by the controller.
2. Safety Instructions
2.1. Description of Key Words and Symbols in the Operating Instructions
In these operating instructions classified key words and symbols are used to identify dangers and items that require special attention.
Symbol
Key word
Meaning
DANGER
This symbol indicates possible risk for life.
CAUTION
This symbol indicates danger of damage to property and/or environment.
NOTE
This symbol indicates useful additional information and operating suggestions.
2.2. Qualification of Operating and Service Staff
The MHM Flash Cure is built in accordance to all appropriate safety regulations. Nevertheless, the Flash Cure must only be operated and maintained by suitably skilled staff. ‘Qualified personnel’ refers to people who are able to carry out the required procedures and be able to recognize as well as prevent potential risks, as a result of their training and experience. If casual workers are employed for assistance work they must be particularly informed regarding existing and potential dangers and instructed accordingly.
Operating Instruction MHM Flash Cures
Operating instructions MHM Flash Cures.docx Page 5 of 17
2.3. Safety Instructions for the Operating Staff
All cabinets and covers of the Flash Cure must always be kept closed. Open cabinets and covers are extremely dangerous as live electrical components are accessible.
Mechanical or electrical failures must only be repaired by an MHM authorized / approved technician.
Any modifications or changes to the dryer settings should only be carried out by an MHM authorized / approved technician.
2.4. Additional Risks
Even though the MHM Flash Cure has been designed and built according to the most stringent safety criteria, as with all machinery we have to anticipate certain additional risks, which are detailed below:
Danger
Description
Behavior/Action
Electrical threats:
Indirect contact
(in case of defect)
Danger of life-threatening electrical shock by indirect contact with defective parts carrying voltage (in particular in case of defective insulation).
Switch off the machine with the main switch. Isolate the mains supply.
Hot surface
Warning: Surfaces can get hot. Danger of burning.
Do not touch the lamps or reflector while the unit is in use or before it has cooled down after switching off.
2.5. Other Valid Rules and Regulations
The customer must comply with all regulations applicable in the country where the machine is located.
3. Intended usage of the machine
The dryer is designed for use in screen printing machines to cure ink with heat.
Any other use of the dryer than described above may result in danger to persons or material damage and is therefore forbidden.
Operating Instruction MHM Flash Cures
Operating instructions MHM Flash Cures.docx Page 6 of 17
4. Data
This section details the Flash Cure technical specifications.
4.1. Serial Number and Year of Manufacture
Serial number and year of manufacture are indicated on the unit’s type plate.
4.2. MHM part numbers
Name
MHM part number
3x 400V
MHM part number
3x 210V
QC 4646 MW
ZUB000030
ZUB000030-2
QC 4355 MW
ZUB000013
ZUB000013-2
QC 4661 MW
ZUB000015
ZUB000015-2
QC 4669 MW
ZUB000021
ZUB000021-2
QC 4170 MW
ZUB000017
ZUB000017-2
QC 5069 MW
ZUB000019
ZUB000019-2
QC 70100 MW
ZUB000023
ZUB000023-2
QC 8044 MW
ZUB000029
ZUB000029-2
QC 6080 MW
ZUB000028
ZUB000028-2
QC 4646 HTL
ZUB000025
ZUB000025-2
QC 4355 HTL
ZUB000012
ZUB000012-2
QC 4661 HTL
ZUB000014
ZUB000014-2
QC 4170 HTL
ZUB000016
ZUB000016-2
QC 70100 HTL
ZUB000022
ZUB000022-2
NB: As our policy is one of continuous improvement, we reserve the right to change specifications without prior notice.
Operating Instruction MHM Flash Cures
Operating instructions MHM Flash Cures.docx Page 7 of 17
4.3. Dimensions
Name
Length
Width
Height
QC 4646 MW
850 mm
564 mm
315 mm
QC 4355 MW
685 mm
455 mm
278 mm
QC 4661 MW
755 mm
500 mm
277 mm
QC 4669 MW
855 mm
500 mm
278 mm
QC 4170 MW
740 mm
560 mm
250 mm
QC 5069 MW
852 mm
560 mm
250 mm
QC 70100 MW
1170 mm
730 mm
270 mm
QC 8044 MW
957 mm
463 mm
240 mm
QC 6080 MW
971 mm
633 mm
270 mm
QC 4646 HTL
850mm
564mm
315mm
QC 4355 HTL
685mm
455mm
278mm
QC 4661 HTL
755mm
500mm
277mm
QC 4170 HTL
740mm
560mm
250mm
QC 70100 HTL
1170mm
730mm
270mm
4.4. Specifications
Name
Drying surface
Fans
Lamps
Power at
3x 400V
Power at
3x 210V
Current
at 3x
400V
Current
at 3x
210V
QC 4646 MW
450*460 mm
1
6x MW3001
11,3 kW
9,4 kW
25,3 A
39,7 A
QC 4355 MW
426*540 mm
2
6x MW5001
12,7 kW
10,6 kW
19,2 A
30,1 A
QC 4661 MW
465*610 mm
2
6x MW7001
14,3 kW
11,9 kW
21,5 A
33,7 A
QC 4669 MW
465*690 mm
3
6x MW4001
14,3 kW
11,9 kW
21,7 A
33,9 A
QC 4170 MW
410*699 mm
2
9x MW3001
17,0 kW
14,2 kW
25,4 A
39,9 A
QC 5069 MW
499*690 mm
3
6x MW4001
14,3 kW
11,9 kW
21,7 A
33,9 A
QC 70100 MW
709*1000 mm
6
9x MW9001
38,1 kW
31,8 kW
56,7 A
89,2 A
QC 8044 MW
800*434 mm
2
6x MW6001
13,7 kW
11,4 kW
20,7 A
32,4 A
QC 6080 MW
605*800 mm
3
9x MW6003
13,9 kW
-
21,1 A
-
QC 4646 HTL
450*460 mm
1
6x HTL1701
9,9 kW
8,3 kW
14,7 A
23,2 A
QC 4355 HTL
426*540 mm
2
9x HTL1503
13,5 kW
11,3 kW
20,1 A
31,7 A
QC 4661 HTL
465*610 mm
2
9x HTL1500
13,5 kW
11,3 kW
20,1 A
31,7 A
QC 4170 HTL
410*699 mm
2
9x HTL1701
14,9 kW
12,4 kW
22,1 A
34,7 A
QC 70100 HTL
650*1121 mm
6
18x
HTL2001
36,0 kW
30,0 kW
53,5 A
84,2 A
Operating Instruction MHM Flash Cures
Operating instructions MHM Flash Cures.docx Page 8 of 17
5. Installation
The Flash Cure may be installed into either an empty station or a print station. The Flash Cure must be powered by a separate supply, which must correspond to the technical data of the unit. To control the unit the dryer must be connected with the dryer connector of the printing machine.
5.1. Ambient Conditions
For the electrical equipment on the MHM Flash Cure, ambient conditions according to standard IEC 60204 “Electrical Equipment of Industrial Machines” should be observed.
The following points should be observed in order to achieve efficient running and an optimum level of production with the MHM Flash Cure:
1. The premises, where the unit is to be operated, must be kept clean, dry and well-aired.
2. The ambient temperature must not fall below +5° C or exceed +45° C.
3. Relative air humidity must not exceed 80 %.
4. The mains supply must not exceed or fall below a tolerance of +/- 5 % of the required
voltage for the MHM Flash Cure. If this voltage stability cannot be guaranteed, the customer must install a constant-voltage regulator to protect the unit against such fluctuations.
5. Electricity supply should be sufficient with adequate fuse protection.
6. Maximum installation altitude is 2000m above sea level.
Upon delivery of the MHM Flash Cure the consignment must be examined for external damage immediately. In the case of any damages, they must be documented and reported to Machines Highest Mechatronic GmbH within 24 hours.
Fragile spotlights! Handle the unit carefully. Breakage due to improper handling is not covered by warranty.
Risk of electric shock! Avoid any contact with live components. Please observe the general safety regulations for electrical connections when connecting the mains supply to the MHM Flash Cure. It is important that a qualified electrician should make all connections.
Operating Instruction MHM Flash Cures
Operating instructions MHM Flash Cures.docx Page 9 of 17
5.2. Electrical requirements
The MHM Flash Cure must be connected to a suitable power supply. The permissible voltage can be read on the type plate. An incorrect voltage will damage the device and result in loss of warranty.
The voltage will be either:
3x 400 V => 3 Phase + N + PE or 3x 210 V => 3 Phase + PE
The frequency must be 50 Hz or 60 Hz. The values for voltage and frequency must be within ±5 %.
5.3. Start signal
The MHM flash cure may be connected to the screen printing machine with the cable supplied or to a footswitch, micro-switch, photocell or proximity switches, if so specified, via the connection socket on the rear of the machine.
5.4. Height adjustment
Using the screws in the brackets on the side of the Flash Cure the height can be adjusted. As an initial setting a distance of 35-40 mm (1½ - 2ins) between the pallet and the lamps is recommended.
When connecting to 3x 400 V the NEUTRAL MUST be connected. When connecting to 3x 210 V the NEUTRAL is NOT connected.
Operating Instruction MHM Flash Cures
Operating instructions MHM Flash Cures.docx Page 10 of 17
6. Design
6.1. Component description
1. Control panel
2. Top cover
3. Screws for fan cover grill
4. Cover grill
5. Fan
6. Main switch
7. Height adjustable brackets
8. Main body
9. Top cover fixing screws
10. Identification and CE plate
11. Power supply
12. Connection socket for control cable from printing machine or switching device
Instead of the Cover grill a filter frame with easily removable filters can be mounted.
Alternative filter frame:
Operating Instruction MHM Flash Cures
Operating instructions MHM Flash Cures.docx Page 11 of 17
6.2. Control panel
A. Control panel fixing screws B. Membrane Switch ‘POWER/TEMP 1 +’: increases heat output C. Membrane Switch ‘POWER/TEMP 1 -’: reduces heat output D. LED Display Selected heat level E. Membrane Switch ‘DISPLAY’: switches display between power and drying time or Temp 1 and Temp 2 F. LED ‘AUT’: automatic mode selected G. Membrane Switch ‘FUNCTION’: selects manual or automatic mode H. LED ‘MAN’: manual mode selected I. Membrane Switch ‘TIME/TEMP 2 +’: increases drying time J. Membrane Switch ‘TIME/TEMP 2 -’: reduces drying time K. LED Display Selected drying time L. Membrane Switch ‘TEST’: manual start switch M. LED ‘INPUT’ start signal active N. LED ‘OUTPUT’ ready signal active O. Membrane Switch Lamp zone selection switches P. LED's Zone selected indicators
Operating Instruction MHM Flash Cures
Operating instructions MHM Flash Cures.docx Page 12 of 17
7. Operating the unit
7.1. Normal operation
1. Turn on mains switch 6. The fans will start and the control panel display will light up showing
either the manufacturer’s settings or the setting last used.
2. Select the appropriate heating zones by pressing one or more of the lamp zone selection
switches. The LED's indicate when a zone has been selected.
3. The level at which the unit operates can be set between 1 and 10 by using the ‘+’ or ‘-
‘POWER/TEMP1’ switches. Between the flash operations the unit returns to the normal standby level awaiting the next input signal. The unit also has another unique feature in that after a predetermined number of minutes during which time no input signal is received the unit will switch to a low standby level to avoid overheating the pallets and this time can also be set by the user. For information regarding the setting of these levels please refer to the programming instructions on Page 9.
4. Dependent upon the last used mode either lamp ‘AUT’ (automatic) or lamp ‘MAN’ (manual)
will light. To change the mode press the ‘FUNCTION’ switch.
5. The ‘TIME/TEMP2’ display shows the time in tenths of a second from 0.0 to 9.9 and in seconds
from 10 to 99. To change the indicated time press either ‘+’ or ‘-’. Keeping either switch pressed results in an increasingly rapid change of the display.
6. The power level and the drying time can also be adjusted while the flash cure is in operation. To
alter the settings simply press the ‘+’ or ‘-’ membrane switches which are located below each display. The power and time displays will start to pulse and pressing the ‘+’ or ‘-’ switch will
change the appropriate display. The new setting will take effect from the start of the next cycle.
7. When the automatic mode lamp is burning, the unit is controlled by input signals through the
connection socket on the rear of the machine.
8. When the start signal is given by either the printing machine or external switch e.g. footswitch
or photocell the unit will switch on and the Input lamp will light. When the ‘TIME’ display has
counted down to zero the ‘OUTPUT ‘lamp will light and the dryer will give a ready signal to
the carousel and the time display will change to the pre-set time.
9. Using the function switch to select the ‘MAN’ mode the unit can then be operated by using the
‘TEST’ switch on the control panel.
Pressing the ‘TEST’ switch at any time while the unit is operating in either the ‘AUT’ or ‘MAN’ mode will stop the countdown and return the unit to the
normal standby state.
Operating Instruction MHM Flash Cures
Operating instructions MHM Flash Cures.docx Page 13 of 17
7.2. Overheat protection
When the temperature inside the unit rises above 70 °Celsius, the unit switches off automatically to protect the electronics. In this case, the temperature inside the controller will be shown in the ‘POWER/TEMP1’ display. While the unit cools down, make sure that the fans are working and the cover grill is not obstructed. Should the unit require cleaning, switch off and unplug the power cord.
When the unit has cooled down it may be restarted using the ‘TEST’ switch, which will return the
unit to the standby position.
7.3. Programming the Flash Cure
The unit as delivered has the normal standby and maximum heat output levels as well as a low standby level and the time before this low level is activated pre-set.
The user may change any or all of these settings as follows:
Press and hold ‘FUNCTION’ button until display changes - approximately 5 seconds.
This set up program may be interrupted and the unit returned to normal operating mode at any time
by pressing the ‘TEST’ button.
The manufacturer’s settings are:
[S-d] [000] [P-H] [099] [P-L] [020] [P-d] [003] [d-d] [002]
As soon as an input signal is received the unit will operate normally irrespective of whether it is in the normal or low level standby position. While the unit is in the low level standby position the displays will display [PPP] and [ddd].
Do not cover or obstruct the fans. This may result in loss of efficiency or reduction of lifetime.
Do not touch the lamps or reflector while the unit is in use or before it has cooled down after switching off.
To switch off the low level standby setting the [d-d] time should be set to [000].
Operating Instruction MHM Flash Cures
Operating instructions MHM Flash Cures.docx Page 14 of 17
Explanation of the controller settings.
Start Delay (0 to 9,99 seconds)
When the Carousel sends the activation signal, the start delay will delay turning on the machine in order to prevent peak currents.
High Power Level (0 to 99%)
Output power level in high power mode.
Normal Standby Level (0 to 50%)
Output power level in low power mode.
Low Standby Level (0 to 50%)
If the machine does not receive an input signal for a prolonged period of time, the machine will switch to the low standby level in order to conserve energy.
Delay Activation Low Standby Level (0 to 99 minutes)
Amount of time without a received input signal before the machine switches to the low standby level.
SETTING
ACTION
POWER / TEMP 1 DISPLAY
TIME / TEMP 2 DISPLAY
Start delay setting
TO CHANGE THIS LEVEL PRESS
TIME/TEMP 2 ‘+’ OR ‘-’ SWITCH PRESS ‘FUNCTION’ SWITCH
HIGH POWER LEVEL
TO CHANGE THIS LEVEL PRESS
TIME/TEMP 2 ‘+’ OR ‘-’ SWITCH
PRESS ‘FUNCTION’ SWITCH
NORMAL STANDBY LEVEL
TO CHANGE THIS LEVEL PRESS
TIME/TEMP 2 ‘+’ OR ‘-’ SWITCH PRESS ‘FUNCTION’ SWITCH
LOW STANDBY LEVEL
TO CHANGE THIS LEVEL PRESS
TIME/TEMP 2 ‘+’ OR ‘-’ SWITCH PRESS ‘FUNCTION’ SWITCH
DELAY IN MINUTES BEFORE LOW STANDBY LEVEL IS ACTIVATED
TO CHANGE DELAY TIME PRESS
TIME/TEMP 2 ‘+’ OR ‘-’ SWITCH
PRESS ‘TEST’ SWITCH TO RETURN TO
NORMAL OPERATING MODE
Operating Instruction MHM Flash Cures
Operating instructions MHM Flash Cures.docx Page 15 of 17
7.4. Changing lamps
How to replace a lamp:
1. Open the flash cure by removing the two black caps and unscrewing the M4 bolts and cap
retainers on each side of the lid.
2. Lift the lid and locate in the hole in the lid. Support the lid with the rod that can be found in
the front of the dryer. Note which cables are attached to the lamp to be changed, loosen the bolts that secure the wires into the ceramics on either end of the lamp. pull the bolts out of the ceramic and leave the cables loose.
3. Remove the lamp from underneath the unit by loosening the wing nuts at either end of the
lamp. Hold it by the ceramics and ease it out of the lamp holders, now remove it from the dryer.
4. The lamps are installed in the dryer with tension springs at either end. Make sure that the
replacement lamps are installed in the right orientation.
5. To install the replacement lamp, gently ease it into the holders. Guide the cables from either
end of the lamp through the reflector. Tighten the wing nuts until the lamp is secure but take care not to over tighten them.
6. Place each cable end in the lamp ceramics. Secure them by tightening the screw holding
them into each ceramic.
7. After any accidental skin contact with the glas or quartz lamp surface the lamp has to be
degreased. To do this, gently clean the lamp with the provided cleaning cloth or other soft cloth moistened with Denatured Alcohol or Methylated Spirits.
8. Make sure that the ceramic ends of the lamp do not touch the housing and that the carbon
element is horizontal.
9. Close the lid by the support rod and carefully lowering the lid. Secure the lid by re-inserting
the cap retainers, M4 bolts and black caps.
10. Reattach the power cable and turn the unit on.
Safety precautions:
Unplug all mains power to the flash cure dryer. If the flash cure was recently in operation ensure the unit has cooled down
before attempting to change the lamps.
The lamps are made of quartz glass and are therefore fragile –handle with
care and avoid contact with the glass.
Tools required: Slot screwdriver & crosshead screwdriver
If the lamp is thought to have failed under guarantee conditions, it should be returned in appropriate packaging to MHM or other appointed dealer for assessment.
Operating Instruction MHM Flash Cures
Operating instructions MHM Flash Cures.docx Page 16 of 17
8. Maintenance of the Flash Cure
Task
Frequency
Comment/Action
Grills and fans cleaning
Daily
Clean the grills and fans.
Weekly cleaning.
Weekly
Open the unit and remove all lint and dust from inside the unit and ensure that all the holes in the reflector are clean and unobstructed.
Lamp cleaning.
Monthly
Clean the lamps when they are cold with a cloth moistened with methylated spirits or denatured alcohol.
9. Accessories
9.1. Temperature sensor
The temperature sensor is used to measure the temperature of the ink and to optimize the drying time.
9.2. Photocell
The photocell is used to start the Flash Cure after a print cycle when the printing machine does not deliver an appropriate start signal.
9.3. Footswitch
With the footswitch, a manual start signal can be generated.
Safety precautions:
Unplug all mains power to the flash cure dryer. If the flash cure was recently in operation ensure the unit has cooled down
before attempting to change the lamps.
The lamps are made of quartz glass and are therefore fragile –handle with
care and avoid contact with the glass.
It is important when either cleaning or changing a lamp that the quartz is not touched by hands or fingers. If the lamps are touched then they must be cleaned before switching on.
Operating Instruction MHM Flash Cures
Operating instructions MHM Flash Cures.docx Page 17 of 17
10. Terms of the Guarantee
The terms of the guarantee are detailed in the General Terms and Conditions of Machines Highest Mechatronic GmbH.
11. Support, Customer Service and Hotline
In case of any problems or additional questions please turn to your appropriate service partner.