MGE UPS Systems TM 30, TM EX30, TM EXB20, TM EX20 User Manual

Pulsar
TM
EX20 / EX30 EXB20/30
Manuel d'utilisation User Manual Manual de instrucciones
+
… …
%
+
… …
%
Pulsar EX20
Thank you for purchasing the EX Uninterruptible Power Supply. The EX has been designed to provide many years of trouble-free operation. Please review the manual which has been prepared to provide you with all the necessary information concerning the installation and use of your EX.
For service call 1-800-523-0142. Sincerely,
MGE UPS SYSTEMS
Federal Communications Commission (FCC) Statement
Note: this equipment has been tested and
found to comply with Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when equipment is operated in a residential environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits.
Nous vous remercions pour l’achat de l'Alimentation sans interruption EX. Nous vous invitons à lire ce manuel en souhaitant qu’il apporte tous les éléments nécessaires à l’installation et à l’utilisation de votre onduleur EX.
Appelez le numéro de téléphone 714­513-7349.
Nous vous prions d’agréer, Madame, Monsieur, nos sentiments les meilleurs.
MGE UPS SYSTEMS
Le agradecemos la compra del SAI EX. Lo invitamos a leer este manual esperando que éste le brindará todos los elementos necesarios para la instalación y la utilización de su SAI
EX.
Contáctenos al siguiente número de teléfono 714-513-7349.
Le saludamos a Ud. muy cordialmente.
MGE UPS SYSTEMS
0
Pulsar EX : 51032278XT/AB
MGE UPS SYSTEMS
note
c this equipment has been tested and found to comply with Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
service and factory repair - call 1 - 800 - 523 - 0142
c direct questions about the operation, repair, or servicing of this equipment to MGE UPS SYSTEMS, Inc. Customer Support Services. Include the part number, assembly number, and serial number of the unit in any correspondence. Should you require factory service for your equipment, contact MGE UPS SYSTEMS, Inc. Customer Support Services and obtain a Return Materials Authorization (RMA) prior to shipping your unit. Never ship equipment to MGE UPS SYSTEMS, Inc. without first obtaining an RMA.
proprietary rights statement
c the information in this manual is the property of MGE UPS SYSTEMS, Inc., and represents a proprietary article in which MGE UPS SYSTEMS, Inc., retains any and all patent rights, including exclusive rights of use and/or manufacture and/or sale. Possession of this information does not convey any permission to reproduce, print, or manufacture the article or articles shown herein. Such permission may be granted only by specific written authorization, signed by an officer of MGE UPS SYSTEMS, Inc.; c IBM, PC-AT, ES/9000, and AS/400 are trademarks of International Business Machines Corporation. Other trademarks that may be used herein are owned by their respective companies and are referred to in an editorial fashion only.
two years warranty policy
c MGE UPS SYSTEMS, Inc. (herein after referred to as MGE) warrants Topaz and Pulsar equipment manufactured by MGE to be free from defects in materials and workmanship for a period of two years from date of purchase. If within such period purchaser discovers defective item and promptly notifies MGE in writing, MGE shall repair or replace the item at the Company's option. This warranty shall not apply:
v to equipment not manufactured by MGE, v to equipment repaired or altered by others than MGE, v to equipment subjected to negligence, accident, or damage by circumstances beyond MGE's control, or to improper operations, maintenance,
or storage, or to other than normal use or service. With respect to equipment not manufactured by MGE, the Warranty obligations of MGE shall in all respects conform and Warranties do not cover reimbursement for labor, transportation, removal, installation, or other expenses which may be incurred in connection with repairs or replacement. Except as may be expressly provided in an authorized writing by MGE, MGE shall not be subject to any other obligations or liabilities whatsoever with respect to equipment manufactured by MGE or service rendered by MGE. After Sales Service Support Line: 1-800-523-0142.
MGE UPS SYSTEMS
Pulsar EX : 51032278XT/AB
MGE UPS SYSTEMS, Inc.
51032278XT/AB
Postal address:
1660 Scenic Avenue Costa Mesa, CA 92626 714-557-1636
ENGLISH IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
This manual contains important instructions for Models EX20 / EX30 / EXB20/30 that should be followed during installation and maintenance of the UPS batteries.
c This equipment can be operated by any individual, with no previous training; c CAUTION: Risk of electric shock, even with unit disconnected from AC power source. Hazardous voltage still may be present through operation from battery. The battery supply should be disconnected at the plus and minus terminals using the quick disconnect connectors of the battery when maintenance or service work inside the UPS is necessary.
c The UPS contains voltages which are potentially hazardous. All repairs should be performed by qualified service personnel only; c do not attempt to power the UPS from any receptacle other than a 2-pole 3-wire grounded receptacle;
c do not place Pulsar near water or in environment of excessive humidity; c do not allow liquids or any foreign objects to get inside Pulsar; c do not block air vents in the back of Pulsar; c do not plug household appliances such as hair dryers to Pulsar receptacles; c do not place Pulsar in direct sunlight or close to heat-emitting source;
MGE UPS SYSTEMS
c the AC power receptacle should be near the equipment and easily accessible. To isolate Pulsar from AC input, remove the input power cord from the AC power receptacle; c if Pulsar is to be stored for a long time, it is recommended to recharge the batteries (by connecting AC power source to Pulsar, switch "ON" or "OFF"), once a month for 24 hours to avoid a full batteries discharge; c Pulsar contains batteries that should be disposed of or recycled in accordance with local applicable laws; c prior to installation, store Pulsar in a dry location; c storage temperatures must be between –4°F (-20°C) and +113°F (+45°C); c servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries; c when replacing the batteries, use the same number and the following type of batteries:
v Pulsar EX20: 8 x 12V - 6.5Ah, v Pulsar EX30 : 8 x 12V - 7.2Ah;
c ~ : alternating current supply symbol;
Pulsar EX : 51032278XT/AB
c CAUTION: do not dispose of battery or batteries in a fire. The battery may explode; c CAUTION: do not open or mutilate the battery or batteries, released electrolyte is harmful to the skin and eyes. It may be toxic; c CAUTION: a battery can present a risk of electric shock and high short circuit current. The following precautions should be observed when working with batteries: v remove watches, rings or other metal objects,
v use tools with insulated handles, v wear rubber gloves, boots and safety
glasses; c please dispose of the packaging in accordance with the applicable legislation.
i
ENGLISH introduction
In critical situations, count on MGE UPS SYSTEMS Pulsar EX20 and EX30 uninterruptible power supplies (UPS). Their protection keeps your data intact and accessible. Pulsar EX20 and EX30 UPSs ensure top quality power around the clock, and continue operations during power failures. An intelligent microprocessor detects any operating anomalies of the UPS and triggers an alarm if corrective action is necessary. In addition to the high-technology aspect of these UPSs, you can count on backup from our staff, a team of specialists, around the corner from you, throughout the world. It’s no accident that MGE UPS SYSTEMS is the world leader in UPS protection. The UPS shall provide power factor correction to prevent harmonic distorsions and current created by non-linear critical loads from polluting the incoming AC line.
UPS includes:
c batteries, c power factor correction / battery charger, c DC to DC converter, c DC to AC Converter, c bypass switch, c input/output filters.
The MGE Pulsar UPS is capable of providing the following modes of operation: c ON LINE MODE which is the primary mode of operation in which the critical load is continuously supplied by the inverter and protected from all forms of power line disturbances:
AC
IN
EMI filter
power
factor
corrector
rectifier
charger
DC / DC
micro
control and
DC to AC
inverter
monitored
batteries
critical
system
c BYPASS MODE which is a default mode in the event of an inverter failure or overload in which the critical load is supplied AC through EMI/RFI filter:
AC
IN
EMI filter
power
factor
corrector
rectifier
charger
DC / DC
micro
control and
DC to AC
inverter
monitored
batteries
critical
system
application of Pulsar EX20 and EX30:
Network servers and interconnection devices are very sensitive to electrical disturbances of all types, including outages, voltage sags, brownouts, spikes, etc. The origins of the disturbances also vary,
ranging from atmospheric phenomena, to nearby devices generating interference such as elevators, photocopy machines and machine tools, not to mention human errors, like the accidental pulling out of power cords or tripping of circuit breakers. The consequences of these disturbances on computer systems range from data losses to hardware damage (power supplies, hard disks). Pulsar EX20 and EX30 are specially designed to protect network servers and all other interconnection devices that are sensitive to electrical disturbances. Pulsar EX20 and EX30 add fault-tolerance to the utility supplying your sensitive equipment. Pulsar EX20 and EX30 are designed as compact units and feature very quiet operation. They can be installed under a desk, and can also be installed in a rack (see "options"). Pulsar EX20 and EX30 provide a stable supply of clean power, long back-up time during a utility outage (see table) and vast information and control possibilities according to the configuration selected. Pulsar EX20 and EX30 On-Line technology provides maximum protection and availability of your workstations, server, and network communication devices. Pulsar EX20 and EX30 offer many functions and characteristics designed to simplify power management: c automatic battery test carried out periodically. In the event of a fault, a LED provides advance warning for battery replacement;
iv
Pulsar EX : 51032278XT/AB MGE UPS SYSTEMS
Loading...