6 Internet servers/1U rack (1500 VA)Pulsar EXtreme 1500C 6 minutes
High performance LAN Switch (1500 VA)Pulsar EXtreme 1500C + 3 Pulsar EXB 1500C 80 minutes
Pulsar EXtreme C UPSs have been
designed to meet the needs of modern
equipment, including network, intranet
and internet servers, internetworking
devices, computer and telecom (PBX)
centres, medical equipment and sensitive
industrial processes.
Pulsar EXtreme C is available in both
tower and rack versions with power
ratings from 700 to 1500 VA.
Pulsar EXtreme C provides power protection and extends battery life to increase
system reliability.
◗ On-line double conversion
technology
Pulsar EXtreme C UPSs use double
conversion (on-line) technology, the only
way to overcome all power problems.
The battery is used only as a backup source.
Automatic bypass
Bypass mode
On-line mode
FilterFilter
Battery
Whatever the disturbances on the distribution system, the
waveform is regenerated via the AC to DC then DC to AC
conversion process.
◗ Wide input-voltage range
Pulsar EXtreme C UPSs have a very wide
input-voltage range from 120 to 276 V,
optimized to improve compatibility with
engine generator sets and reduce the
number of transfers to battery power.
The batteries are used only for the most
serious incidents, maximizing available
backup time and extending battery life.
◗ High-performance battery
charger
The Pulsar EXtreme battery charger:
• reduces battery recharge time (80%
backup time recovered in two hours);
• increases the service life of the battery
by taking into account manufacturer
parameters and battery aging;
• protects the battery against damage
caused by deep discharge;
• avoids disturbances on the distribution
system by correcting the power factor;
• avoids propagating faults on the
distribution system (backfeed
protection).
◗ Certified compliance with
CE and UL standards
High availability
Pulsar EXtreme C UPSs guarantee a high level of
availability, equal to 99.999% or higher.
◗ Cold start on battery power
This function ensures trouble-free start-up
of your applications even during a utility
power outage.
◗ Automatic bypass
In the event of an overload or UPS fault,
Pulsar EXtreme C automatically transfers
the load to utility AC power.
◗ High-availability pack
A Pulsar STS source transfer switch
combined with two Pulsar EXtreme C UPSs
provides effective power redundancy.
Pulsar EXtreme Rack
"preferred" source
Pulsar EXtreme Rack
"alternate" source
Advanced communications
Ease of use
Pulsar EXtreme C UPSs offer communications solutions and accessories for remote UPS control
and monitoring.
◗ 2 communications ports
◗ Communications slot
Lets you add an SNMP, dry contact, etc.
communication card.
The cards make UPS
communication
RS232
communications port
An RS232 and a USB port are available
for easy connection of the UPS to the
server. It may be used for:
• personalization of Pulsar EXtreme C
USB
communications port
totally independent.
For example, they
keep you informed
of UPS status when
the server is shut
down.
by modifying the factory-set parameters
(output voltage, intervals between battery
tests, operation on bypass, etc.) via
UPS-Driver software.
• local or remote administration
(SNMP/WEB) of the UPS and the protected
servers, using Solution-Pac software.
◗ Solution-Pac software
Solution-Pac may be used to:
• alert users;
• automatically shut down different
◗ UPScontrol remote display
Using UPScontrol, the
various UPS
parameters are remotely
displayed.
◗ MultiSlot expansion module
This module provides three additional
communications slots and concentrates
the data from an installation comprising
redundant UPSs
servers in a heterogeneous environment;
• remotely supervise and control UPSs.
Pulsar EXtreme C is only two units high (2U)
and fits perfectly in your network or telecom
bays.
◗ Easy installation and integration
• Tower or 19”-rack models
• Complete installation kit
Pulsar EXtreme C is supplied with telescopic
rails and all the necessary hardware
Flexibility and scalability
Pulsar EXtreme C can adapt easily to all your needs, today and tomorrow.
◗ Backup times from 6 minutes to
several hours
Pulsar EXtreme offers a standard backup
time of 6 minutes.
To ensure greater continuity of service,
it is possible to:
• connect up to three Pulsar EXB battery
extension modules to the UPS, without
interrupting the supply of power to the
protected applications;
Pulsar EXtreme 1500 C + 3 Pulsar EXB
modules for 80 minutes of backup time
at full rated load .
• use the CLA module (long backup-time
charger) for very long backup times of up
to eight hours at full rated load.
Feel free to contact us for details.
◗ Hot-swappable batteries
Users can replace the batteries themselves
without having to shut down the protected
equipment.
◗ Individual management of
outlets with Powershare
The programmable outlets
make it possible to save
battery power for the most
critical applications. They
may also be used to
remotely restart or reset a
faulty device without
interrupting the other
protected devices.
• Quick start-up guide
• Easy connection to AC power.
◗ Comprehensive display
and controls
UPS overload
electronics fault
battery fault
status of
programmable
outlet no.1
status of
programmable
outlet no.2
ON/OFF
TM
% battery backup time
press and hold to display
percent load
lamp test or buzzer off
forced transfer to and from
bypass
operation on bypass
operation in ON-LINE mode
operation on battery
◗ Warranty and services
Pulsar EXtreme C is covered
by a two-year full
warranty.
The optional MGE
Warranty+ extension
ensures user peace
of mind for three
years on site.
Characteristics
Pulsar EXtreme700 C1000 C1500 C
General
Power (Pn)700 VA / 490 W1000 VA / 700 W1500 VA / 1050 W
Input-voltage range120/140/160 to 276 volts without using battery power (1)
Frequency range50/60 Hz (auto-selection)
Power factor (THDI)>0.95 (< 5%)
Sinusoïdal output voltage200/208/220/230/240 Volts
Harmonic distortion<4% on linear load, <6% on non-linear load
Efficiency 85%87%88%
Crest factor3:13:13:1
Short circuit current (A)252929
Overload capacity (Online mode)110% permanent, 130% 12s, >130% 1.5s
Standard7147 17 619
Pulsar EXtreme C + 1 Pulsar EXB 244727592479
Pulsar EXtreme C + 2 Pulsar EXB 4182479343119
Pulsar EXtreme C + 3 Pulsar EXB 531246413662168
Automatic battery testYes, at regular intervals without risk of interrupting protected applications
Communicatio
USB port yesyesyes
RS232 port yesyesyes
Optional cards SNMP card
Environment
Acoustic noise
Operating temperature0 to 40°C
Standards and certifications
PerformanceEN 50091-3/IEC 62040-3
SafetyEN 50091-1, EN 60950 (RD/), IEC 60950
EMC EN 50091-2/IEC 62040-2, EN 55022/B, FCC 47 part 15 - Subpart B - Class A,
Marking and certificationsCE,TÜV/GS, UL, cUL, C-Tick
Design and manufactureISO 9001
automatic recognition of
battery extension modules
2 programmable outlets
connectors for Pulsar EXB battery
extension modules
Warranty + for UPS668136681366818668186681866818
Warranty + for Pulsar EXB668136681366813668136681366813
Warranty + for Pulsar CLA6681866818
alarm and battery level indicators
press and hold to display percent load
lamp test or buzzer off
forced transfer to and from bypass
status of programmable outlets 1 and 2
operation on bypass, in ON-LINE mode
or on battery
ON/OFF
AC input connector
As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication.
All the trademarks quoted belong to their respective owners. Publication: MGE UPS SYSTEMS, 11 2000 - Production: B SYLVAIN - Illustrations: Lucy in the Sky, ADN Communications.
MGE UPS SYSTEMS
140, avenue Jean Kuntzmann
ZIRST - Montbonnot Saint Martin
38334 St Ismier Cedex - France
Tel : (33) (0)4 76 18 30 00
MGE0384UKO
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.