Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment.
The Pulsar range has been designed with the utmost care.
We recommend that you take the time to read this manual to take full advantage of the many features of your UPS
(Uninterruptible Power System).
Before installing Pulsar, please read the booklet on the required safety instructions. Then follow the indications in this
manual.
To discover the entire range of MGE UPS SYSTEMS products and the options available for the Pulsar range, we invite you
to visit our web site at www.mgeups.com or contact your MGE UPS SYSTEMS representative.
Environmental protection
MGE UPS SYSTEMS has implemented an environmental-protection policy.
Products are developed according to an eco-design approach.
Substances
This product does not contain CFCs, HCFCs or asbestos.
Packing
To improve waste treatment and facilitate recycling, separate the various packing components.
◗ The cardboard we use comprises over 50% of recycled cardboard.
◗ Sacks and bags are made of polyethylene.
◗ Packing materials are recyclable and bear the appropriate identification symbol .
Material Abbreviation Symbol
Introduction
number
Polyethylene terephthalate PET 01
High-density polyethylene HDPE 02
Polyvinyl chloride PVC 03
Low-density polyethylene LDPE 04
Polypropylene PP 05
Polystyrene PS 06
Follow all local regulations for the disposal of packing materials.
End of life
MGE UPS SYSTEMS will process products at the end of their service life in compliance with local regulations.
MGE UPS SYSTEMS works with companies in charge of collecting and eliminating our products at the end of their service life.
Product
The product is made up of recyclable materials.
Dismantling and destruction must take place in compliance with all local regulations concerning waste.
At the end of its service life, the product must be transported to a processing centre for electrical and electronic waste.
Battery
The product contains lead-acid batteries that must be processed according to applicable local regulations concerning
batteries.
The battery may be removed to comply with regulations and in view of correct disposal.
"Material Safety Data Sheets" (MSDS) for the batteries are available on our web site*.
The
(*) For more information or to contact the Product Environmental manager, use the
www.mgeups.com -> About us -> Environment.
"Environmental Form" on the site:
34008097EN/AB - Page 3

Introduction
Pictograms
Important instructions that must always be followed.
Information, advice, help.
Visual indication.
Action.
Audio signal.
In the illustrations on the following pages, the symbols below are used:
LED off
LED on
LED flashing
34008097EN/AB - Page 4

Contents
1. Presentation
1.1 Standard positions ...................................................................................................................... 6
Tower position................................................................................................................................ 6
Rack position ................................................................................................................................. 6
1.2 Rear panels................................................................................................................................... 7
Pulsar 700 / 1000 / 1500................................................................................................................ 7
Pulsar 1000 RT / 1500 RT ............................................................................................................. 7
Pulsar EXB (optional battery module)............................................................................................7
Pulsar EXB RT (optional battery module)...................................................................................... 8
1.3 Control panel................................................................................................................................8
2. Installation
2.1 Unpacking and contents check .................................................................................................. 9
2.2 Installation of the RT model in tower position........................................................................ 10
2.3 Installation of the RT model in a rack ...................................................................................... 10
2.4 Communication ports.................................................................................................................11
Connection of RS232 or USB communication port (optional).......................................................11
Installation of the communication cards (optional)....................................................................... 12
2.5 Connection with a FlexPDU (Power Distribution Unit) module ................................................ 12
2.6 Connection with a HotSwap MBP module............................................................................... 13
HotSwap MBP-module operation................................................................................................. 13
2.7 UPS connection without a FlexPDU or HotSwap MBP module ............................................. 14
3. Operation
3.1 Start-up and normal operation ................................................................................................. 15
3.2 Operation on battery power...................................................................................................... 15
3.3 Return of AC power ................................................................................................................... 16
3.4 UPS shutdown............................................................................................................................ 16
3.5 Using the UPS remote control functions................................................................................. 16
4. Access to measurements and personalisation data
4.1 Display menus arrangement..................................................................................................... 18
4.2 Access to measurements.......................................................................................................... 18
4.3 Personalisation using the control panel.................................................................................. 18
4.4 Personalisation using external software ................................................................................. 19
5. Maintenance
5.1 Troubleshooting......................................................................................................................... 20
Troubleshooting a UPS equipped with the HotSwap MBP module ............................................. 21
5.2 Battery-module replacement .................................................................................................... 21
Safety recommendations ............................................................................................................. 21
Battery-module removal............................................................................................................... 21
Mounting the new battery module................................................................................................ 23
5.3 Maintenance on a UPS equipped with the HotSwap MBP module........................................ 24
5.4 Training centre ........................................................................................................................... 25
6. Appendices
6.1 Technical specifications............................................................................................................ 26
6.2 Glossary ..................................................................................................................................... 27
6.3 Connection to the communication port by relays .................................................................. 27
34008097EN/AB - Page 5

1. Presentation
1.1 Standard positions
Tower position
Dimensions (H x W x D) in mm
Pulsar 700 242 x 158 x 400
Pulsar 1000 242 x 158 x 400
Pulsar 1000 RT 438 x 86,5 x 480
Pulsar 1500 242 x 158 x 450
Rack position
Pulsar 1500 RT
Pulsar EXB 242 x 158 x 400
Pulsar EXB RT 440 x 86,5 x 480
Weights in kg
Pulsar 700 12,5
Pulsar 1000 15
Pulsar 1000 RT 18
Pulsar 1500 18
Pulsar 1500 RT
Pulsar EXB 21
Pulsar EXB RT 24,5
438 x 86,5 x 480
20,5
34008097EN/AB - Page 6

1.2 Rear panels
Pulsar 700 / 1000 / 1500
4
8
5
3
7
1. Presentation
1
2
6
9
10
(1) USB communication port
(2) RS232 and dry contacts communication
port
(3) Connector for automatic recognition of a
battery EXB module (except on Pulsar 700)
(4) Slot for optional communication card
(5) Connector for remote ON/OFF and RPO
(Remote Power Off) control
(6) Connector for battery EXB module
(7) Group of 3 programmable outlets for
connection of equipment
(8) Group of 3 outlets for connection of
equipment
(9) Socket for connection to AC-power source
(10) LED (SWF) indicating distribution
system phase/neutral reversal
Pulsar 1000 RT / 1500 RT
5
2
1
3
10
Pulsar EXB (optional battery module)
6
4
(11) Connectors for battery modules (to the
11
12
13
11
8 9
7
UPS or to the other battery modules)
(12) Connectors for automatic recognition of
battery modules
(13) Protection circuit-breaker.
34008097EN/AB - Page 7

1. Presentation
Pulsar EXB RT (optional battery module)
11
1.3 Control panel
ESC
24 25 26
27
12
202122
23
13
(20) Load protected LED
(21) Downgraded operation LED
(22) Load not protected LED
(23) Alphanumeric display
(24) Escape (cancel) button
(25) Scroll button
(26) Enter (confirm) button
(27) ON/OFF button for UPS and outlets
34008097EN/AB - Page 8

2.1 Unpacking and contents check
2. Installation
30
37
32
31
38
33
35
36
34
39
40
42
41
Settings/Sensor
ETHERNET
100M 10M
On = Link
Blink = Act
UPS data RS232
66102
43
44
(30) Pulsar 700, 1000, 1500
(31) Pulsar 1000 RT, 1500 RT
(32) 2 connection cables for the protected equipment
(33) RS232 communication cable
(34) USB communication cable
(35) Securing system for equipment power cords
(36) Solution-Pac CD-ROM and documentation
Elements supplied depending on the version or optional
(37) Mounting kit for 19-inch bays
(38) 2 supports for the upright position (RT model only)
(39) FlexPDU module (optional)
(40) Connection cable between FlexPDU module and UPS
(41) NMC communication card (optional)
(42) HotSwap MBP module (optional)
(43) Connection cables between HotSwap MBP module and
AC-power source
(44) Connection cables between HotSwap MBP module and
UPS
Packing materials must be disposed of in compliance with all local regulations concerning waste.
Recycling symbols are printed on the packing materials to facilitate sorting.
34008097EN/AB - Page 9