www.mgeups.com
Pulsar M
2200 RT 2U
2200 RT 3U
3000 RT 2U
3000 RT 3U
3000 RT 3U XL
EXB RT 3U
Installation and user
manual
R
E
D
I
V
O
R
P
R
E
W
O
P
E
L
B
I
T
P
U
R
R
E
T
N
I
N
U
E
H
T
34003641FR/AA - Page 1

Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment.
The Pulsar M range has been designed with the utmost care.
We recommend that you take the time to read this manual to take full advantage of the many features of your UPS
(Uninterruptible Power System).
Before installing Pulsar M, please read the booklet on the required safety instructions. Then follow the indications in this
manual.
To discover the entire range of MGE UPS SYSTEMS products and the options available for the Pulsar M range, we invite
you to visit our web site at www.mgeups.com or contact your MGE UPS SYSTEMS representative.
Environmental protection
MGE UPS SYSTEMS has implemented an environmental-protection policy.
Products are developed according to an eco-design approach.
Substances
This product does not contain CFCs, HCFCs or asbestos.
Packing
To improve waste treatment and facilitate recycling, separate the various packing components.
◗ The cardboard we use comprises over 50% of recycled cardboard.
◗ Sacks and bags are made of polyethylene.
◗ Packing materials are recyclable and bear the appropriate identification symbol .
Material Abbreviation Symbol
Introduction
number
Polyethylene terephthalate PET 01
High-density polyethylene HDPE 02
Polyvinyl chloride PVC 03
Low-density polyethylene LDPE 04
Polypropylene PP 05
Polystyrene PS 06
Follow all local regulations for the disposal of packing materials.
End of life
MGE UPS SYSTEMS will process products at the end of their service life in compliance with local regulations.
MGE UPS SYSTEMS works with companies in charge of collecting and eliminating our products at the end of their service life.
Product
The product is made up of recyclable materials.
Dismantling and destruction must take place in compliance with all local regulations concerning waste.
At the end of its service life, the product must be transported to a processing centre for electrical and electronic waste.
Battery
The product contains lead-acid batteries that must be processed according to applicable local regulations concerning
batteries.
The battery may be removed to comply with regulations and in view of correct disposal.
"Material Safety Data Sheets" (MSDS) for the batteries are available on our web site*.
The
(*) For more information or to contact the Product Environmental manager, use the
www.mgeups.com -> About us -> Environment.
"Environmental Form" on the site:
34007776EN/AB - Page 3

Introduction
Pictograms
Important instructions that must always be followed.
Information, advice, help.
Visual indication.
Action.
Audio signal.
In the illustrations on the following pages, the symbols below are used:
LED off
LED on
LED flashing
34007776EN/AB - Page 4

Contents
1. Presentation
1.1 Standard positions ...................................................................................................................... 6
Tower position................................................................................................................................ 6
Rack position ................................................................................................................................. 6
1.2 Rear panels................................................................................................................................... 7
Pulsar M 2200 / 3000..................................................................................................................... 7
Pulsar M EXB (optional battery module)........................................................................................ 7
1.3 Control panel................................................................................................................................7
2. Installation
2.1 Unpacking and contents check .................................................................................................. 8
2.2 Installation in tower position ...................................................................................................... 9
2.3 Installation in rack position ........................................................................................................ 9
2.4 Communication ports................................................................................................................ 10
Connection of RS232 or USB communication port (optional)...................................................... 10
Installation of the communication cards (optional)....................................................................... 10
2.5 Connection with a FlexPDU (Power Distribution Unit) module .................................................11
2.6 Connection with a HotSwap MBP module................................................................................11
HotSwap MBP-module operation................................................................................................. 12
2.7 UPS connection without a FlexPDU or HotSwap MBP module ............................................. 12
3. Operation
3.1 Start-up and normal operation ................................................................................................. 13
3.2 Operation on battery power...................................................................................................... 13
3.3 Return of AC power ................................................................................................................... 14
3.4 UPS shutdown............................................................................................................................ 14
3.5 Using the UPS remote control functions................................................................................. 14
4. Access to measurements and personalisation data
4.1 Display menus arrangement..................................................................................................... 16
4.2 Access to measurements.......................................................................................................... 16
4.3 Personalisation using the control panel.................................................................................. 16
4.4 Personalisation using external software ................................................................................. 17
5. Maintenance
5.1 Troubleshooting......................................................................................................................... 18
Troubleshooting a UPS equipped with the HotSwap MBP module ............................................. 19
5.2 Battery-module replacement .................................................................................................... 19
Safety recommendations ............................................................................................................. 19
Battery-module removal............................................................................................................... 19
Mounting the new battery module................................................................................................ 20
5.3 Maintenance on a UPS equipped with the HotSwap MBP module........................................ 20
5.4 Training centre ........................................................................................................................... 21
6. Appendices
6.1 Technical specifications............................................................................................................ 22
6.2 Glossary ..................................................................................................................................... 23
34007776EN/AB - Page 5

1. Presentation
1.1 Standard positions
Tower position
Dimensions (H x W x D) in mm
Pulsar M 2200 RT 2U 440 x 86 x 640
Pulsar M 2200 RT 3U 440 x 131 x 490
Pulsar M 3000 RT 2U 440 x 86 x 640
Pulsar M 3000 RT 3U 440 x 131 x 490
Rack position
Pulsar M 3000 RT 3U XL
Pulsar M EXB RT 3U 440 x 131 x 490
Weights in kg
Pulsar M 2200 RT 2U 31
Pulsar M 2200 RT 3U 30
Pulsar M 3000 RT 2U 31
Pulsar M 3000 RT 3U 30
Pulsar M 3000 RT 3U XL
Pulsar M EXB RT 3U 42
440 x 131 x 490
17
34007776EN/AB - Page 6

1.2 Rear panels
Pulsar M 2200 / 3000
21
3 7
1. Presentation
8
5611
9 104
(1) USB communication port
(2) RS232 communication port
(3) Connector for automatic recognition of an
additional battery module
(4) Slot for optional communication card
(5) Connector for remote ON/OFF and RPO
(Remote Power Off) control
(6) Connector for additional battery module
(7) 16 A outlet for connection of equipment
(8) Two groups of 2 programmable outlets for
connection of equipment
(9) Groups of 4 outlets for connection of
equipment
(10) Socket for connection to AC-power
source
(11) LED (SWF) indicating distribution
system phase/neutral reversal
Pulsar M EXB (optional battery module)
1.3 Control panel
202122
23
ESC
(12) Connectors for battery modules (to the
UPS or to the other battery modules)
(13) Connectors for automatic recognition of
battery modules
1312 12
(20) Load protected LED
(21) Downgraded operation LED
(22) Load not protected LED
(23) Alphanumeric display
(24) Escape (cancel) button
(25) Scroll button
(26) Enter (confirm) button
(27) ON/OFF button for UPS and outlets
24 25 26
27
34007776EN/AB - Page 7

2. Installation
2.1 Unpacking and contents check
32
31
30
35
38
42
ETHERNET
100M 10M
On = Link
Blink = Act
36
Settings/Sensor
UPS data RS232
33
34
37
39
41
40
43
44
66102
34007776EN/AB - Page 8
(30) Pulsar M 2200 or 3000 UPS
(31) connection cable to AC-power source
(32) 2 connection cables for the protected equipment
(33) RS232 communications cable
(34) USB communications cable
(35) 2 systems to secure power plugs
(36) Solution-Pac CD-ROM
(37) Documentation
Elements supplied depending on the version or optional
(38) Mounting kit for 19-inch bays
(39) 2 supports for the upright position (2U version only)
(40) FlexPDU module (optional)
(41) connection cable between FlexPDU module and UPS
(42) NMC communication card (optional)
(43) HotSwap MBP module (optional)
(44) connection cables between HotSwap MBP module and
UPS
Packing materials must be disposed of in compliance with all local regulations concerning waste.
Recycling symbols are printed on the packing materials to facilitate sorting.