MFJ MFJ-1704 User Manual

MFJ-1704 4-Position Coaxial Switch
Thank you for purchasing the MFJ-1704 4-Position
Coaxial Switch.
The MFJ-1704 utilizes heavy cast metal
construction and ball bearing drive for smooth switching.
Plus the MFJ-1704 has a replacable lightning/surge
protection pellet and center ground position. When the 1704 is in the center position, all connectors are disconnected and grounded. If the switch is turned to an active
connector, the other connectors are automatically grounded.
replacable lightning/surge protector.
*CAUTION*DO NOT SWITCH CONNECTORS WHILE TRANSMITTING.
Should a lightning strike occur, the replacable lig­htning/surge protection pellet will short to ground pro­tecting your equipment.
Open the 1704 and check the pellet if it does not recover by itself. If the pellet is burned out, it will need to be replace. While waiting for the replacement pellet, your equipment could be operated without
lightning protection by removing the burned out pellet but it is NOT recommended for the safety of your equipment.
GROUNDING
Requirements:
A seperate, external ground wire must be used with the MFJ-
1704.
This wire should be connected to either of the thru-
removed from the base plate at the point of connection to provide a good.solder surface.