MFJ 209 Instruction Manual

Page 1
MFJ-209 SWR Analyzer Instruction Manual
MFJ-209 HF/VHF SWR Analyzer
TABLE OF CONTENTS
Table of Contents......................................................................................................1
Introduction..............................................................................................................2
Powering The MFJ-209 ............................................................................................3
Battery Installation....................................................................................................3
Operation Of The MFJ-209 .......................................................................................4
SWR and the MFJ-209..................................................................................4
Measuring SWR............................................................................................5
Adjusting Simple Antennas .......................................................................................6
Dipoles..........................................................................................................6
Verticals........................................................................................................6
Tuning an Antenna........................................................................................6
Measuring the Feedpoint Resistance of Antennas ...........................................7
Testing and Tuning Stubs and Transmission Lines.....................................................7
Velocity Factor of Transmission Lines...........................................................8
Impedance of Transmission Lines..................................................................9
Estimating transmission line loss....................................................................9
Adjusting Tuners.......................................................................................................10
Adjusting Amplifier Matching Networks...................................................................10
Testing RF Transformers ..........................................................................................11
Testing Baluns...............................................................................................11
Measuring Inductance and Capacitance.....................................................................12
Measure capacitance......................................................................................12
Measure inductance.......................................................................................12
Resonant Frequency of tuned circuits........................................................................13
Testing RF Chokes........................................................................................14
"Zero Beating" the MFJ-209.....................................................................................14
Using the MFJ-209 as a Signal Source......................................................................15
Technical Assistance.................................................................................................15
MFJ-209 Parts List ...................................................................................................15
1
Page 2
MFJ-209 SWR Analyzer Instruction Manual
The MFJ-209 SWR Analyzer is an easy to operate, versatile test instrument for analyzing nearly any 50 ohm RF system on frequencies between 1.8 and 170 MHz. In addition the MFJ­209 can be used as signal source.
The MFJ-209 combines three basic circuits; a wide range oscillator, a 50 ohm RF bridge, and a calibrated bridge unbalance indicator. This combination of circuits allows measurement of the SWR (referenced to 50 ohms) of any load connected to the ANTENNA connector.
The MFJ-209 covers all ham bands from 2 meters to 160 meters. The dial calibration is approximate and for reference only. The actual frequency may vary from what is marked on the front panel. The MFJ-209 FREQUENCY switch selects the following frequency ranges:
1.8 - 4 MHz 4 - 10 MHz 10 - 26.2 MHz
26.2 - 62.5 MHz
62.5 - 113 MHz 113 - 170 MHz
A frequency counter, such as the MFJ-346, can be connected to the "FREQ. OUT" jack (RCA phono) to get a more accurate reading of the frequency. As an alternative to a frequency counter, you can zero beat the output with an HF receiver. See the section on zero beating the MFJ-209 with a receiver.
The MFJ-209 can be used to adjust or measure the following:
Antennas: SWR, resonant frequency, bandwidth, efficiency Antenna tuners: SWR, frequency Amplifiers: Input and output networks Coaxial transmission lines: SWR, velocity factor, losses, resonance Balanced transmission lines: Impedance, velocity factor, resonance Matching or tuning stubs: SWR, resonant frequency, bandwidth Traps: Resonant frequency Tuned Circuits: Resonant frequency Small capacitors: Value RF chokes and inductors: Self resonance, series resonance, value Transmitters and oscillators: Frequency
Warning: Please read this manual thoroughly before using this instrument. Failure to follow
the operating instructions may cause false readings or even damage this unit.
2
Page 3
MFJ-209 SWR Analyzer Instruction Manual
POWERING THE MFJ-209
The MFJ-209 requires between 8 and 18 volts for proper operation. Any power supply used with the MFJ-209 must be capable of supplying 200mA of current. An optional power supply, the MFJ-1312B, is available from MFJ for $12.95.
The MFJ-209 has a standard 2.1 mm female receptacle on the top right edge of the case. This jack is labeled "12VDC" and has the word "POWER" near it. A pictorial polarity marking appears on the case near the power jack. The outside conductor of the plug must connect to the negative supply voltage and the center conductor of the plug must connect to the positive voltage. The internal battery pack is automatically disconnected when an external power plug is inserted in this jack.
SWR measurement will be inaccurate when the supply voltage falls below 7 volts. To avoid false readings maintain fresh batteries and always use the correct power supply.
Warning: Never apply AC, unfiltered or incorrectly polarized DC to this jack. Peak voltage
must never exceed 18 volts.
BATTERY INSTALLATION
If batteries are used, they must be installed by removing the 8 phillips head screws on each side of the case. The eight batteries fit in two separate battery holders with the positive terminal of the batteries positioned toward the round fixed connection, and the negative terminals toward the springs of the battery holder.
The battery case has two external terminals that connect to a "pigtail" that has two terminals on it. This connector looks like the type used for 9 volt transistor radio batteries and connects in the same way. Do not attempt to use 9 volt batteries with this unit. After the batteries are installed in the plastic holders and the connections are made to the battery packs, the battery holders can be slid directly into the chrome retaining clips on the cover.
MFJ recommends the use of ALKALINE AA (or rechargeable nicad) cells to reduce the risk of equipment damage from battery leakage. Avoid leaving any batteries in this unit during periods of extended storage. Remove weak batteries immediately!
Carefully check the following: * The battery packs are positioned so that they do not interfere with any internal parts of the
MFJ-209.
* The leads are positioned to reach with the cover in the original position. * The wires are not pinched between the cover and the chassis.
3
Page 4
MFJ-209 SWR Analyzer Instruction Manual
OPERATION OF THE MFJ-209
After the MFJ-209 is connected to a proper power source the red on-off button can be depressed to apply power. When pressed, the red button should lock into position.
The "ANTENNA" connector (SO-239 type) on the top of the MFJ-209 provides the SWR bridge output connection. To measure SWR, this connector must be connected to the load or device under test.
Warning: Never apply power to the "ANTENNA" connector.
SWR and the MFJ-209
Some understanding of transmission line and antenna behavior is necessary to use the MFJ-209 properly. For a thorough explanation the ARRL Handbooks or other detailed textbooks can be used for reference.
SWR is the ratio of a load impedance to source impedance. Since nearly all feedlines and radio equipment used in amateur service are 50 ohms, this instrument is designed to measure the system SWR normalized to 50 ohms. For example a 150 ohm load placed across the "ANTENNA" connector will give an SWR reading of 3:1 .
4
Page 5
MFJ-209 SWR Analyzer Instruction Manual
The MFJ-209 measures actual SWR. The load must be 50 ohms of pure resistance for a meter reading of 1:1 . The common misconception that 25 ohms of reactance and 25 ohms of resistance in a load will give a 1:1 SWR is absolutely untrue. The actual SWR in this condition will be measured as 2.6:1 . The MFJ-209 is not "fooled" by mixtures of reactive and resistive loads.
Another common misconception is that changing a feedlines length will change SWR. If the impedance of a feedline is 50 ohms and the load impedance is 25 ohms the SWR will remain 2:1 as the feedline length changes. If line loss is low it is perfectly acceptable to make SWR measurements at the transmitter end of the feedline. The feedline does not have to be any particular length. However, as line loss increases, and as SWR increases, more error is introduced into the SWR reading. The error causes the measured SWR reading to appear better than the actual SWR at the antenna. Refer to the section on estimating the line loss on page 10.
If changing feedline length changes the SWR reading, one or more of the following must be true:
the feedline is not 50 ohms,
the bridge is not set to measure 50 ohms,
the line losses are significant,
the feedline is acting like part of the antenna system and radiating RF.
Feedlines with very low losses, such as air insulated transmission lines, will not have much loss even when operating at extremely high SWRs. High loss cables, such as small polyethylene dielectric cables like RG-58, will rapidly lose efficiency as the SWR is increased. With high loss or long feedlines it is very important to maintain a low SWR over the entire length of the feedline.
Any SWR adjustments have to be made at the antenna, since any adjustments at the transmitter end of the feedline can not affect the losses, nor the efficiency of the antenna system.
Measuring SWR
The MFJ-209 will measure the impedance ratio (SWR) of any load referenced to 50 ohms. The SWR can be measured on any frequency from 1.8 to 170 MHz. No other devices are required.
To measure the SWR on a predetermined frequency adjust the "TUNE" and "FREQUENCY" knobs to the desired frequency. To accurately measure the MFJ-209's frequency connect a counter to the "FREQ. OUT" jack or zero beat the MFJ-209 with a receiver. Read the SWR from the "SWR" meter.
To find the lowest SWR adjust the frequency until the SWR meter reaches the lowest reading. Read the approximate frequency of the lowest SWR from the "TUNE" scale or measure the exact frequency with a counter.
5
Page 6
MFJ-209 SWR Analyzer Instruction Manual
ADJUSTING SIMPLE ANTENNAS
Most antennas are adjusted by varying the length of the elements. Most home made antennas are simple verticals or dipoles that are easily adjusted.
Dipoles
Since a dipole is a balanced antenna, it is a good idea to put a balun at the feedpoint. The balun can be as simple as several turns of coax several inches in diameter, or a complicated affair with many windings on a ferromagnetic core.
The height of the dipole, as well as it's surroundings, influences the feedpoint impedance and the line SWR. Typically, dipoles have a SWRs below 1.5:1 .
Generally the only adjustment on a dipole is the length of the antenna. If the antenna is too long it will resonate too low in frequency, and if it is too short it will resonate too high.
Verticals
Verticals are usually unbalanced antennas. Most antenna manufacturers downplay the importance of good radial systems with grounded verticals. If you have a good ground system the SWR of a quarter wave vertical can be nearly 2 to one. The SWR generally gets BETTER as the ground system, and performance, get worse.
Verticals are tuned like dipoles, lengthening the element moves the frequency lower, and shortening the element moves the frequency higher.
Tuning an Antenna
Tuning basic antennas fed with 50 ohm coaxial cable can be accomplished with the following steps:
1 Connect the feedline to the MFJ-209. 2 Adjust the MFJ-209 until the SWR reaches the lowest reading. 3 Read or measure (with a counter) the MFJ-209's frequency. 4 Divide the measured frequency by the desired frequency. 5 Multiply the present antenna length by the result of step 4. This is the new length needed.
Note: This method will not work on loaded or electrically shortened antennas. They must be
tuned by adjusting and re-testing until the proper frequency is obtained.
6
Page 7
MFJ-209 SWR Analyzer Instruction Manual
50R
P
Measuring the Feedpoint Resistance of Antennas
The feedpoint resistance of a low impedance (10-100 ohm) resonant HF antenna or load can be measured with the MFJ-209. A low value non-inductive potentiometer (250 ohms) and a conventional ohm meter can be used to make these measurements.
1 Connect the MFJ-209 directly across the terminals of the unknown impedance. If the load
is unbalanced be sure that the ground is connected to the SO-239 "ANTENNA" connector's ground.
2 Adjust the MFJ-209 until the SWR reads the lowest value. 3 If the SWR is not unity (1:1), place the potentiometer in parallel with the load. Adjust the
potentiometer until the SWR is as good as possible.
4 If the SWR only becomes worse go to step 7. 5 If the SWR reached unity, remove the potentiometer and measure its resistance. 6 The resistance of the load is found by using the formula below.
R =
A
R = Antenna resistance
A
P
R - 50
P
R = Potentiometer resistance
7 If the earlier steps did not work put the potentiometer in series with the center pin
(ungrounded terminal) of the SO-239 "ANTENNA" connector.
8 Adjust the value of the potentiometer until the SWR is unity (1:1). 9 Remove the potentiometer and measure the resistance of the setting used in step 8.
Subtract this value from 50 to determine the load resistance.
TESTING AND TUNING STUBS AND TRANSMISSION LINES
The proper length of quarter and half wave stubs or transmission lines can be found with this unit and a 50 carbon resistor. Accurate measurements can be made with any type of coaxial or two wire line. The line does not have to be 50 ohms.
The stub to be tested should be attached with a 50 noninductive resistor in series to the center conductor of the "ANTENNA" connector with a coaxial line. The shield should be grounded to the connector shell. For two wire lines the 50 resistor connects in series between the ground shell of the PL-259 and one conductor. The other conductor of the balanced line connects directly to the center pin of the connector.
Coaxial lines can lie in a pile or coil on the floor, two wire lines must be suspended in a straight line a few feet away from metallic objects or ground. The lines must be open circuited at the far end for odd multiples of 1/4 wave stubs (i.e., 1/4, 3/4, 1-1/4, etc.) and short circuited for half wave stub multiples ( like 1, 1-1/2, etc.)
7
Page 8
MFJ-209 SWR Analyzer Instruction Manual
246
Connect the PL-259 to the "ANTENNA" connector of the MFJ-209 and adjust the line or stub by the following method. For critical stubs you may want to gradually trim the stub to frequency.
1 Determine the desired frequency and theoretical length of the line or stub. 2 Cut the stub slightly longer than necessary. 3 Measure the frequency of the lowest SWR. It should be just below the desired frequency. 4 Divide the measured frequency by the desired frequency. 5 Multiply the result by the length of the stub. This is the necessary stub length. 6 Cut the stub to the calculated length and confirm that it has the lowest SWR near the
desired frequency.
Velocity Factor of Transmission Lines
The MFJ-209 can accurately determine the velocity factor of any impedance transmission line. Measure the velocity factor with the following procedure:
1. Disconnect both ends of the transmission line and measure the physical length of the line in
feet.
2. Set up the line to measure 1/4 stubs as in the section on Testing and Tuning Stubs, page 7.
3. Find the lowest frequency across all the bands at which the lowest SWR occurs. The dip
should occur slightly below the 1/4 wavelength frequency.
4. Measure the frequency from the MFJ-209. This is the 1/4 resonant wavelength frequency
of your transmission line. Note that you will get low SWR reading at all odd multiples of 1/4 wavelength.
Example: On a 27 foot line the measured frequency was 7.3MHz.
5. Divide 246 by the measured frequency. This gives you the free space 1/4 wavelength in
feet. Example: 246 divided by a dip frequency of 7.3 MHz is 33.7 feet, the free space 1/4
wavelength
6. Divide the physical measured length of the feedline in feet by the free space 1/4 wavelength
calculated in number 5. Example: 27 feet (physical length) divided by 33.7 feet (calculated length) equals .80 .
The velocity factor is .80 or 80%.
Free space 1/ 4 wavelength =
Velocity Factor =
Free space 1/ 4 wavelength
Actual feedline length
Low SWR frequency
8
Page 9
MFJ-209 SWR Analyzer Instruction Manual
Impedance of Transmission Lines
The impedance of transmission lines between 15 and 150 ohms can be measured with the MFJ­209, a 250 ohm potentiometer, and an ohm meter. Lines of higher impedance can be measured with a higher resistance potentiometer if a broad band transformer is used (see the section on testing transformers) to transform the line impedance to approximately 50 ohms.
1 Measure the 1/4 wavelength frequency of the transmission line to be tested as in Testing
and Tuning Stubs on page 7.
2 Terminate the far end of the transmission line with a non-inductive 250 ohm potentiometer. 3 Connect the transmission line to the MFJ-209 "ANTENNA" connector and set the analyzer
to the 1/4 wave frequency.
4 Observe the SWR as you vary the "TUNE" from end to end of the "FREQUENCY" range
selected.
5 Adjust the potentiometer until the SWR reading varies as little as possible, over the
"TUNE" range. Note that the value of the SWR is not important. Only the change in SWR as the frequency is varied is important.
6 The value of the potentiometer will correspond closely to the line impedance.
Estimating transmission line loss
The loss of 50 ohm feedlines (between 3 and 10 dB) can be measured with the MFJ-209. It is a simple matter to find the loss at a known frequency and then estimate the loss at a lower frequency.
To measure feedline loss:
1. Connect the feedline to the MFJ-209 "ANTENNA" connector.
2. The far end of the feedline is either left unconnected or terminated with a direct short.
3. Adjust the MFJ-209 frequency to the frequency desired and observe the "SWR" meter.
4. If the SWR is in the red area of the scale the loss is less than 3 dB. Increase the frequency
until the "SWR" meter reads 3:1. This is the 3dB loss frequency.
5. If the SWR on the operating frequency is in the black area of the "SWR" meter, pick the
closest SWR point and estimate the loss from the chart below.
SWR LOSS
3.0 : 1 3.0 dB
2.5 : 1 3.6 dB
2.0 : 1 4.7 dB
1.7 : 1 5.8 dB
1.5 : 1 6.9 dB
1.2 : 1 10.3 dB
You can estimate the approximate loss at the operating frequency by remembering that the feedline loss in dB is reduced by 70 % at half the frequency, and increased by 140 % at twice the frequency you measured. This method is reasonably accurate if the loss is distributed along the feedline and not confined to one bad area.
9
Page 10
MFJ-209 SWR Analyzer Instruction Manual
For example, assume an operating frequency of 28 MHz. You want to know what the feedline loss is at 28 MHz. At that frequency the "SWR" meters needle is in the red uncalibrated portion of the meter. Increase the measured frequency until the needle falls on a calibration mark. At 60MHZ the meter reads 3:1 SWR. Using the chart you know that the loss is 3 dB. Since 28MHz is about half of 60MHz, you can multiply 3dB by .7 giving a loss of about 2dB at 28MHz.
ADJUSTING TUNERS
The MFJ-209 can be used to adjust tuners. Connect the MFJ-209 "ANTENNA" connector to the tuner's 50 ohm input and the desired antenna to the normal tuner output. This connection can be made with a manual RF switch to facilitate rapid changeover.
Warning: Always connect the common (rotary contact) of the switch to the tuner. The
switch must connect either the MFJ-209 or the station equipment to the tuner.
The Station Equipment Must Never Be Connected To The MFJ-209.
1 Connect the MFJ-209 to the tuner input. 2 Turn on the MFJ-209 and adjust it to the desired frequency. 3 Adjust the tuner until the SWR becomes unity (1:1). 4 Turn off the MFJ-209 and re-connect the transmitter.
ADJUSTING AMPLIFIER MATCHING NETWORKS
The MFJ-209 can be used to test and adjust RF amplifiers or other matching networks without applying operating voltages.
The tubes and other components should be left in position and connected so that stray capacitance is unchanged. A non-inductive resistor that equals the approximate driving impedance of the tube is installed between the cathode of the tube and the chassis, or a resistor should be connected between the anode and the chassis that equals the calculated plate impedance of the tube. The appropriate network can now be adjusted.
The antenna relay (if internal) can be engaged with a small power supply so that the coax input and output connectors are tied to the networks.
Caution: The driving impedance of most amplifiers changes as the drive level is varied. Do
not attempt to adjust the input network with the tube in an operating condition with the low level of RF from the MFJ-209.
10
Page 11
MFJ-209 SWR Analyzer Instruction Manual
TESTING RF TRANSFORMERS
RF transformers that are designed with a 50 ohm winding can be easily and accurately tested with the MFJ-209.
The 50 ohm winding is connected through a short 50 ohm cable to the "ANTENNA" connector on the MFJ-209. The other winding(s) of the transformer is then terminated with a low inductance resistor that is equal to the winding's impedance. The MFJ-209 can then be swept through the desired transformer frequency range. The SWR and bandwidth of the RF transformer can be measured.
Testing Baluns
Baluns can be tested by connecting the 50 ohm unbalanced side to the MFJ-209 "ANTENNA" connector. The balun must be terminated with two equal value load resistors in series. The resistor combination must have resistance total that is equal to the balun impedance. A pair of 100 ohm carbon resistors must be used to test the 200 ohm secondary of a 4:1 balun (50 ohm input).
The SWR is measured by moving a jumper wire from point "A" through point "C".
To the MFJ-249's
"ANTENNA"
connector
Clip Lead
BALUN
A
B
C
A properly designed current balun, the type that is the most effective and usually handles the most power, should show a low SWR over the entire operating range of the balun with the clip lead in any of the three positions.
A well-designed voltage balun should show a low SWR over the entire operating range when the clip lead is in position "B". It will show a poor SWR when the clip lead is in position "A" and "C".
A voltage balun should also be tested by disconnecting the outer connections of the two resistors and connecting each resistor in parallel. If the balun is operating properly the SWR will be very low with the resistors connected from either output terminal to ground.
To the MFJ-249's
"ANTENNA"
connector
BALUN
11
Page 12
MFJ-209 SWR Analyzer Instruction Manual
1
1
MEASURING INDUCTANCE AND CAPACITANCE
To measure capacitance or inductance you will need some standard value capacitors and inductors. These should be collected and tested for accuracy. MFJ suggests the following sets of values: Inductors: 330µH, 56 µH, 5.6 µH, 0.47 µH Capacitors: 10 pF, 150 pF, 1000 pF, 3300 pF Readings will be the most accurate if the standard test values used are between 0.5 µH to 500 µH to measure capacitance or 10 pF and 5000 pF to measure inductance.
Take a component of unknown value and connect it in series with a standard component to make a series LC circuit. Attach the series LC circuit to the "ANTENNA" connector in series with a 50 resistor.
Measure capacitance.
1. Connect an unknown capacitor in parallel with the highest value standard inductor.
2. Connect the LC circuit to ANTENNA connector with a 50 resistor in series.
3. Adjust the tune knob through the bands until you get the lowest SWR. If you do not get a
deep meter deflection change to the next inductor with a lower value and try again. Continue the process until you obtain low SWR. Read the resonant frequency off the MFJ­209 scale or measure it with a counter.
4. Solve this equation using F as the resonant frequency as L as the inductance of the standard
inductor,
C(pF) =
00003948F L
.
F = MHz L = H
µ
2
Measure inductance.
1. Connect an unknown inductor with the highest value standard capacitor in parallel.
2. Connect the LC circuit to "ANTENNA" connector with a 50 resistor in series.
3. Adjust the tune knob through the bands until you get the lowest SWR. If you do not get a
deep meter deflection change to the next smaller value standard capacitor and try again. Repeat the process until you get low SWR.
4. Solve this equation using F as the resonant frequency and C as the capacitance of the
standard capacitor.
L( H) =
µ
00003948F C
.
2
F = MHz C = pF
RESONANT FREQUENCY OF TUNED CIRCUITS
12
Page 13
MFJ-209 SWR Analyzer Instruction Manual
50 ohm
The MFJ-209 can be used to measure the resonant frequency of tuned circuits by two methods. The first method involves placing a 50 ohm resistor in series with the MFJ-209 "ANTENNA" connector. The MFJ-209 connects through the resistor to the parallel tuned circuit. This circuit is for high capacitance values.
Tune the MFJ-209's frequency until the "SWR" meter reaches the highest SWR. This is the resonant frequency of the load.
To the MFJ-249's
"ANTENNA"
connector
All leads should be short
50 ohms
Hi - "C"
For high inductance values a series LC circuit should be used to measure resonant frequency. The inductor and capacitor should be connected in series through a 50 low inductance carbon resistor across the "ANTENNA" connector on the MFJ-209.
To the MFJ-249's
"ANTENNA"
connector
50 ohms
All leads should be short
Hi - "L"
Tune the MFJ-209's frequency until the "SWR" meter reaches the lowest SWR. This is the resonant frequency of the load.
An external diode detector and volt meter can also be used to measure the resonant frequency of circuits. The maximum meter reading occurs at the resonant frequency.
To the MFJ-249's
"ANTENNA"
connector
All leads should be short
1N34
.01 10K
Measure the voltage between these points
with a Hi-Z meter
A second method of determining the resonant frequency is by using a small three or four link coil to magnetically couple to a tuned circuit for testing. The coil should be wound around the inductor in the tuned circuit. This magnetically couples the MFJ-209 to the resonant circuit.
The frequency of the MFJ-209 is adjusted for a dip on the "SWR" meter. The dip occurs at the approximate resonant frequency of the tuned circuit.
Testing RF Chokes
13
Page 14
MFJ-209 SWR Analyzer Instruction Manual
choke
Large RF chokes usually have frequencies where the distributed capacitance and inductance form a low impedance series resonance. The troublesome series resonance can be detected by slowly sweeping the frequency of the MFJ-209 over the operating range of the choke. Peaks in the voltage measured by the RF voltmeter will identify the low impedance series-resonant frequencies.
To the MFJ-249's
"ANTENNA"
connector
All leads should be short
10K
1N34
.01
Measure the voltage
between these points
with a Hi-Z meter
Refer to the section on measuring the inductance of RF chokes on page 12.
"ZERO BEATING" THE MFJ-209
The FREQ. OUT jack of the MFJ-209 supplies enough signal to drive a frequency counter or a receiver. The signal from this jack is strong enough to drive all but the poorest receivers without direct coupling.
To measure the frequency with a receiver you should first connect a short wire to the input of the receiver or to the center conductor of coax feeding the receiver. This wire can normally just be placed near the MFJ-209 to provide ample signal strength for the receiver. In rare cases a second wire can be inserted into the FREQ OUT jack and placed near the receiver lead.
To determine the operating frequency of the MFJ-209 the receiver should be set to the widest bandwidth SSB position and tuned to the frequency setting of the MFJ-209 dial. The receiver dial can then be tuned up and down until a signal is heard swooping past.
Zero in on the signal until the pitch becomes very low. The receiver will be approximately on the same frequency as the receiver.
If you use the MFJ-209 primarily on one frequency range you can calibrate the knob. Find a frequency and loosen the set screw on the knob. Carefully pull the knob off and reinsert it at the correct setting. Be sure that the receiver and the MFJ-209 are on the same frequency throughout the procedure.
A second method would be to set the frequency of interest on the dial with a grease pen or other temporary marking device.
14
Page 15
MFJ-209 SWR Analyzer Instruction Manual
USING THE MFJ-209 AS A SIGNAL SOURCE
The MFJ-209 can provide a moderately stable signal source for testing and alignment. Signal is produced by the internal oscillator and can be taken from both the "FREQ.OUT" or the "ANTENNA" jacks. Signal should be taken from the "ANTENNA" jack allowing a frequency counter, such as the MFJ-346, to be attatched to the "FREQ. OUT" jack to measure the frequency of the output signal.
An attenuator pad or variable resistor can be used to reduce the output level of the MFJ-203.
TECHNICAL ASSISTANCE
If you have any problem with this unit first check the appropriate section of this manual. If the manual does not reference your problem or your problem is not solved by following the manual you may call MFJ toll-free at 1-800-647-TECH (8324) or FAX to 601-323-6551, or TELEX 53 4590 MFJ STKV. Outside of the continental U.S.A. 601-323-5869. You will be best served if you have your unit, manual and all information on your station handy so you can answer any questions the technicians may ask.
You can also send questions to MFJ Enterprises, INC., P.O. Box 494, Mississippi State, MS
39762. Send a complete description of your problem, an explanation of exactly how you are using your unit and a complete description of your station.
MFJ-209 PARTS LIST
Part Designator Description MFJ Part Number
R1 Resistor, 1/4 Watt, 5%, Film, 18 Ohm 100-1180 R2,R21,R22 Resistor, 1/4 Watt, 5%, Film, 1m Ohm 100-6100 R3,R8 Resistor, 1/4 Watt, 5%, Film, 100 Ohm 100-2100 R4,R7 Resistor, 1/4 Watt, 5%, Film, 10 Ohm 100-1100 R5,R6,R11 Resistor, 1/4 Watt, 5%, Film, 1.0k Ohm 100-3100 R15,R24,R29,R30 Resistor, 1/4 Watt, 5%, Film, 10.0k Ohm 100-4100 R17 Resistor, Trimpot, Sub. Horz., 10 K 133-4100 R18 Resistor, Trimpot, Sub. Horz., 100 K 133-5100 R26,R27,R28 Resistor, 1/8 Watt, 1%,49.9 Ohm 102-1499 R33 Resistor, 1/4 Watt, 5%, Film, 620 Ohm 100-2620
SW1 Switch, Rotary, Pcb, Horiz. Mt., 2p6p (prgm) 500-1563 FOR SW1 Knob, 1/4" Shaft, .75 X .75, Pka 50b Knob 760-0033 SW2 Switch, Push-Button, PC, .5 A, 125 Vac, 2p2p 504-0022 FOR SW2 Knob, Plastic, Push-Button, .350" Dia, Red 760-2140
15
Page 16
MFJ-209 SWR Analyzer Instruction Manual
Part Designator Description MFJ Part Number
C1 Capacitor, Disc Ceramic, 50v, 20%, 22 pF 200-0018 C2,C3,C4,C6,C7,C8 Capacitor, Disc Ceramic, 25/50v, 20%, .01 uF 200-0004 C10,C33,C36 Capacitor, Disc Ceramic, 25/50v, 20%, .01 uF 200-0004 C11,C13,C14,C16,C19 Capacitor, Disc Ceramic, 25/50v, 20%, .01 uF 200-0004 C17,C18,C24 Capacitor, Disc Ceramic, 50/100v, 20%, .1 uF 200-0005 C20,C21,C25,C26,C27 Capacitor, Disc Ceramic, 25/50v, 20%, .01 uF 200-0004 C22,C23,C32,C39 Capacitor, Disc Ceramic, 25/50v, 20%, .01 uF 200-0004 C28 Capacitor, Electrolytic, Radial, 25v, 100 uF 203-0015 C29 Capacitor, Disc Ceramic, 500v, 20%, 75 pF 200-1011 C30 Capacitor, Disc Ceramic, 1 Kv, 20%, 470 pF 200-2023 C31 Capacitor, Disc Ceramic, 1 Kv, 20%, 33 pF 200-2016 C32 Capacitor, Electrolytic, Radial, 50v, 1 uF 203-0006 C38 Capacitor, Electrolytic, Radial, 35v, 220 uF 203-0019 VC1 Cap, Air Var, 6-200 pF 204-5160
D2,D3 Diode, Germanium, 1N34A 300-8001 D6 Opto, Led, 5 Mm Round, Red, MV5753 320-0001
IC1 IC, Op-amp, Quad Op-amp, 14 Pin, LM324N 311-0040 IC2 Voltage Regulator, 1 Amp, +5 Volts, 7805t 307-1011 FOR IC1 Socket, IC, Low Profile, 14 Pin 625-0031
J1 Jack, 2.1 Mm, Pcb, Dc Coaxial Jack 601-6021 J2 Connector, Header, Straight, .1, .375", 3 Pos 612-0103
JMP1-4 Wire, Jumper, 1/4"-2" 870-5000 L2 Inductor, 10mm, orange,10-403/9447, 2.64uH 402-3403
L3 Inductor, 10mm, Red, 10-402/9449, 1.8 uH 402-3402 L4 Inductor, Var, Pcm, Mc120 llow, .154 uH 402-2727 L7 Toroid, Ferrite, .5", Pre-wound, C/11, Amp 403-0020
M1 Meter, 1.5", 100 uA, SWR Meter 400-0035 Q1,Q2,Q4 Transistor, Fet, To-92, Siliconix, J310 305-6310
Q3 Transistor, Fet, Switching, VN10KM 305-6005 Q5 Transistor, HF Wide Band, NPN, 2N5109 305-0017
B1 Battery, Holder, 8-AA,Snap Connector 730-2362 FOR B1 Battery, Snap, 9v, 8" 730-3005
16
Page 17
MFJ-209 SWR Analyzer Instruction Manual
FULL 12 MONTH WARRANTY
MFJ Enterprises, Inc. warrants to the original owner of this product, if manufactured by MFJ Enterprises, Inc. and purchased from an authorized dealer or directly from MFJ Enterprises, Inc. to be free from defects in material and workmanship for a period of 12 months from date of purchase provided the following terms of this warranty are satisfied.
1. The purchaser must retain the dated proof-of-purchase (bill of sale, canceled check, credit card or money
order receipt, etc.) describing the product to establish the validity of the warranty claim and submit the original of machine reproduction or such proof of purchase to MFJ Enterprises, Inc. at the time of warranty service. MFJ Enterprises, Inc. shall have the discretion to deny warranty without dated proof-of-purchase. Any evidence of alteration, erasure, of forgery shall be cause to void any and all warranty terms immediately.
2. MFJ Enterprises, Inc. agrees to repair or replace at MFJ's option without charge to the original owner any
defective product provided the product is returned postage prepaid to MFJ Enterprises, Inc. with a personal check, cashiers check, or money order for $7.00 covering postage and handling.
3. MFJ Enterprises, Inc. will supply replacement parts free of charge for any MFJ product under warranty
upon request. A dated proof of purchase and a $5.00 personal check, cashiers check, or money order must be provided to cover postage and handling.
4. This warranty is NOT void for owners who attempt to repair defective units. Technical consultation is
available by calling (601) 323-5869.
5. This warranty does not apply to kits sold by or manufactured by MFJ Enterprises, Inc.
6. Wired and tested PC board products are covered by this warranty provided only the wired and tested PC
board product is returned. Wired and tested PC boards installed in the owner's cabinet or connected to
switches, jacks, or cables, etc. sent to MFJ Enterprises, Inc. will be returned at the owner's expense unrepaired.
7. Under no circumstances is MFJ Enterprises, Inc. liable for consequential damages to person or property by
the use of any MFJ products.
8. Out-of-Warranty Service: MFJ Enterprises, Inc. will repair any out-of-warranty product provided the unit
is shipped prepaid. All repaired units will be shipped COD to the owner. Repair charges will be added to the COD fee unless other arrangements are made.
9. This warranty is given in lieu of any other warranty expressed or implied.
10. MFJ Enterprises, Inc. reserves the right to make changes or improvements in design or manufacture
without incurring any obligation to install such changes upon any of the products previously manufactured.
11. All MFJ products to be serviced in-warranty or out-of-warranty should be addressed to MFJ Enterprises,
Inc., 921A Louisville Road, Starkville, Mississippi 39759, USA and must be accompanied by a letter
describing the problem in detail along with a copy of your dated proof-of-purchase.
12. This warranty gives you specific rights, and you may also have other rights which vary from state to state.
17
Loading...