Meyer Sound CONSTEL-4060, d:screet Users Manual

www.dpamicrophones.com
Learn more at www.dpamicrophones.com
Fig. 8. 4080 mounted right
Fig. 6. Placement 20-25 cm (8 10 in) from mouth
Fig. 5. Loop between holder and clip
Fig. 9. Tightening the MicroDot connector
clean the microphone as it will be damaged. Avoid all kinds of spray or fluids containing chemical components to remove static electricity on or close to the microphone as this could cause permanent damage to the electret layer. The pop filter is optimized to perform under difficult conditions, but should it need cleaning, distilled water will wash away any dirt. Use organic oil (e.g. olive oil) or lukewarm, distilled water to remove residue from tape, glue, or make-up from the cable after use. Use organic oil after cleaning to protect the cable sleeve and prolonging its life. Ensure that superfluous cable is wound up in soft loops (preferably 6 -8 cm (2.5 3 in) in diameter) which also helps to reduce handling noise. Do not bend the cable or rub it harshly, it may stress the inner cores of the cable and cause them to break over time.
Correct use of adapters and MicroDot connectors
To provide users with safe and compact mounting of connectors, all Miniature Microphones from DPA are fitted with the MicroDot connector. A broad range of connec- tion adapters is offered as optional accessories for most VHF and UHF systems for professional use. A connector tightening tool is supplied with each adapter and is the only recommendable way to tighten the MicroDot (fig.
9).
3 pin XLR/phantom power use
If running directly into a recording system using 3 pin XLR and phantom power, we recommend the DAD6024
Placement of 4080
To ensure the optimal sound of the 4080, the best posi- tion on the performer’s body is 20-25 cm (8 10 in) from the speaker’s mouth (fig. 6). With its innovative mounting solution it can easily be turned in all directions, upwards and sidewards, to get the best sound. Furthermore, it en- sures that the 4080 fits both left and right buttoned shirts (fig. 7 & 8).
Cleaning guide
Miniature Microphones from DPA are designed to be very resistant to external stress. Highly resistant materials are used in construction of the microphones. Do not try to
XLR adapter, designed for applications when microphone placement is on the human body. When placing a micro- phone on a performer’s chest, an acoustic lower midrange boost will occur resulting in a muddy and indistinct sound, compared to a free frontal placement. The adapter pro- vides a 3 dB attenuation at 800 Hz for added clarity when using the 4080 lavalier.
When using lavalier microphones it is always advisable to insert a high-pass filter at e.g. 80 or 100 Hz in order to avoid rumble from the speaker. You can find these settings on most wireless transmitter equipment as well as on port- able recorder units and mixing consoles.
www.dpamicrophones.com
Accessories DAD6001-BC Adapter
MicroDot to 3-pin. XLR (P48) w. Belt Clip
DAD6024 Adapter
MicroDot to 3-pin. XLR (P48) w. Mid Range Attenuation
DMM0015
4080 Double Clip
Preliminary literature
Introduction
The DPA d:screet™ Miniature Microphones are designed for use with wired or wireless systems in theater, film, television, conferences and instrument close-miking applications.
To ensure optimal performance of your d:screet™ Miniature Microphone, please follow the simple care and maintenance instructions below. Our d:screet Miniature Microphones are designed to be resistant to humidity and moisture. Highly resist­ant materials like gold plated stainless steel, and features like the double-vent protection system, ensures that you avoid damage
by fluids. Keep your d:screet Miniature Mics away from water and cleaning fluids, and keep the microphone element dry at all times.
Cleaning guide
The cable and protection grid are the only parts that may be cleaned. Do not use any kind of cleaning fluid other than demin­eralized water. Avoid all kinds of spray or fluids containing chemi­cal components to remove static electricity on or close to the microphone as this could cause damage to the electret layer.
When mounting a d:screet Miniature Microphone directly on or close to the skin of a performer, care should be taken to avoid sweat from running into the microphone. If the microphone has been exposed to sweat, it must be rinsed out in demineralized water and left to dry out to recover its original specifications. Drying out the microphone between exposures to humidity will also help to extend its lifetime. If the microphone gets filled up with water it will not be damaged, but possibly turn deaf while the water is captured inside the microphone, behind the pro­tection grid. Remove the water by shaking the microphone or drying it with a piece of lint free cloth.
Cleaning the microphone grid
During use in environments where the microphone is exposed to makeup or dusty materials, the grid may get clogged up. Remove the microphone grid from the microphone element (not applicable to SC4071, SCO71-H and 4080) and clean the grid using a soft cloth and demineralized water only. Make sure the grid is dry before re-mounting it on the microphone housing. For SC4071, SCO71-H and 4080 (which do not feature removable grids) cleaning the grid is done using a soft cloth and demineralized water.
Cleaning the microphone cable
Residue from tape, glue, or makeup on the cable must be re­moved after use. Leaving these substances on the cable over longer periods of time may etch into the cable jacket and will make the cable more susceptible to breaks. The cable can easily be cleaned using organic oil (e.g. olive oil) or lukewarm, dem­ineralized water. Do not bend the cable or rub it harshly since this may stress the inner cores of the cable and cause them to break over time.
Microphone grids
The d:screet Miniature Microphones (SC4060/61/62/63 and SCO60/61-H) are supplied with two dierent grids for acoustic equalization, depending on the placement on the performer; a soft boost grid (pre-fitted) giving a 3 dB soft boost at 8-20 kHz. Alternatively, the high boost grid for chest mounting gives ap­proximately 10 dB boost at 12 kHz. Without any grid mounted, the microphone is linear, but unprotected against dirt.
The d:screet Miniature Microphones with presence boost (SC4071 and SCO71-H) and the 4080 have a fixed presence boost grid. These types are pre-equalized to provide optimal speech intelligibility when using chest placement.
Mounting
Several mounting accessories are specially designed to mount, place or conceal the d:screet Miniature Microphones. Refer to www.dpamicrophones.com/dscreet for an up-to-date selection and overview.
d:screetTM 4080
Special for the 4080 is that it is delivered with a pre-mounted pop­filter in a holder with an integrated shock mount, fixed on the DPA clip (fig. 1). The 4080 is designed to be always used in this setup. When mounting the holder on to the clip, a small loop of
1.5 cm (0.6 in) (fig. 2) should be left between the microphone and the holder. Press the cable gently into the cable trail and secure the cable with the cable clamp (fig. 3). To ensure the optimal sound of the 4080, the best position on the performer’s body is 20 - 25 cm
(8 – 10 in) from the speaker’s mouth (fig. 4). With its innovative mounting solution it can easily be turned in all directions, upwards and sidewards, to get the best sound. Furthermore, it ensures that the 4080 fits both left and right buttoned shirts.
Microphone element
The diaphragm in the microphone element is the most sensi­tive part of the unit, and must be left untouched to preserve its original characteristics. Do not spray any substances such as hair spray directly into the microphone and avoid getting makeup or paint on the microphone element and housing.
Correct treatment of the microphone cable
The cable is usually longer than required for its actual purpose. Make sure that superfluous cable is wound up in soft loops (pref­erably 6 – 8 cm (2.4 – 3 in) in diameter). Avoid kinks in the cable. Handling noise from the cable can be reduced significantly by making a loose cable loop, as close to the microphone element as possible.
Correct use of adapters and MicroDot connectors
To provide users with safe and compact mounting of connec­tors, all our d:screet Miniature Microphones are fitted with the
MicroDot connector. A broad range of adapters is oered as optional accessories for most wireless systems for professional use. Never attempt to loosen or tighten the connector by the cable or its strain relief. Some wireless systems require the use of electronic components inside the adapter to optimize the signal level, the DC-oset filtering, and powering of the built-in microphone preamplifier.
Always use the adapters from DPA Microphones with the wire­less systems to ensure the correct electronic circuit. Do not use non-standard adapters or connectors as you might damage the microphone preamplifier.
Fig. 1. 4080 Miniature Cardioid Microphone, Lavalier
Fig. 2. Loop between holder and clip on 4080
Learn more at www.dpamicrophones.com
Fig. 4. Place 4080 20-25 cm (8 – 10 in) from mouth Fig. 7. SCO60-H Heavy Duty in SCM0001 Miniature Clip
Fig. 5. 2 x SC4071 in SCM0008 Miniature Clip Fig. 8. SC4060 in SCM0004 Miniature Clip, Small
Fig. 3. Securing the cable with the cable clamp on 4080
Fig. 6. SC4060 in SCM0017 Miniature Mic Holder
DPZ-4060-3
Specifications
SC4060, SC4061, SC4062, SC4063, SC4071
4080, SCO60-H, SCO61-H, SCO71-H
Directional characteristics
SC4060/61/62/63/71, SCO60-H/61-H/71-H: Omnidirectional 4080: Cardioid
Principle of operation
SC4060/61/62/63/71, SCO60-H/61-H/71-H: Pressure 4080: Pressure Gradient
Cartridge type
Pre-polarized condenser element with vertical diaphragm
Frequency range, ± 2 dB
SC4060/61/62/63, SCO60-H/61-H: Soft boost grid: 20 Hz- 20 kHz, 3 dB soft boost at 8 – 20 kHz High boost grid: 20 Hz- 20 kHz, 10 dB boost at 12 kHz SC4071, SCO71-H: 100 Hz – 15 kHz with typ. 5 dB soft boost at 4-6 kHz 4080: 250 Hz – 17 kHz with typ. 4 dB soft boost at 4 - 6 kHz (-5 dB at 100 Hz)
Sensitivity, nominal, ± 3 dB at 1 kHz
SC4060, SCO60-H, 4080: 20 mV/Pa; -34 dB re. 1 V/Pa SC4061/63/71, SCO61-H/71-H: 6 mV/Pa; -44.5 dB re. 1V/Pa SC4062: 1 mV/Pa; -60 dB re. 1V/Pa
Equivalent noise level, A-weighted
SC4060, SCO60-H, 4080: Typ. 23 dB(A) re. 20 µPa (max. 26 dB(A)) SC4061/63/71, SCO61-H/71-H: Typ. 26 dB(A) re. 20 µPa (max. 28 dB(A)) SC4062: Typ. 33 dB(A) re. 20 µPa (max. 37 dB(A))
S/N ratio (A-weighted) re. 1 kHz at 1 Pa (94 dB SPL)
SC4060, SCO60-H, 4080: 71 dB SC4061/63/71, SCO61-H/71-H: 68 dB SC4062: 61 dB
Total Harmonic Distortion (THD)
<1% THD up to 123 dB SPL peak <1% THD up to 120 dB SPL RMS sine
Dynamic Range
SC4060, SCO60-H, 4080: Typ. 100 dB SC4061/63/71, SCO61-H/71-H: Typ. 97 dB SC4062: Typ. 90 dB
Max. SPL peak before clipping
SC4060, SCO60-H, 4080: 134 dB SC4061/71, SCO61-H/71-H: 144 dB SC4062: 154 dB SC4063: 138 dB
Output impedance
30 – 40 Ω, depending on current draw
Cable drive capability
300 m (984 ft) with DAD6001-BC/DAD6024/DAD4099 XLR phantom power adapter
Power supply
With DAD6001-BC/DAD6024/DAD4099: 48 V phantom power ±4 V for full performance. For wireless systems: Min. 5 V through DPA adapter (SC4063 min. 3 V).
Polarity
Positively increasing sound pressure produces positive going voltage on MicroDot pin.
Connector
MicroDot, adapters are available
Weight incl. cable and MicroDot connector
SC4060/61/62/63: 7.5 g (0.26 oz) SC4071: 9 g (0.32 oz) 4080: 15 g (0.53 oz) SCO60-H/61-H: 13 g (0.46 oz) SCO71-H: 14 g (0.49 oz)
Cable length
1.8 m (5.9 ft) (4080: 1.2 m (4 ft))
Cable diameter
SC4060/61/62/63/71, 4080: 1,6 mm (0.06 in) SCO60-H/61-H/71-H: 2,2 mm (0.09 in)
Temperature range
-40 °C to 45 °C
Relative Humidity (RH)
Up to 90%
Frequency Response
SC4060/61/62/63, SCO60-H/61-H
Polar pattern
SC4060/61/62/63, SCO60-H/61-H
Service & Repair
Products from DPA Microphones are extremely stable and there should not be any significant change in the specifications with time and use. If, however, you are not totally satisfied with the characteristics exhibited by these products, please contact your nearest DPA Microphones representative for fur ther de­tails of service and the repair facilities that are available.
SC4071, SCO71-H
CE Marking
The CE mark guarantees that the product conforms with relevant directives approved by the European Commission.
EMC directive: 2004/108/EEC
Low voltage directive: 2006/95/EC
4080
4080SC4071, SCO71-H
Head Ofce
DPA Microphones A/S Gydevang 42-44 DK-3450 Alleroed, Denmark
Tel: +45 4814 2828
Fax: +45 4814 2700
Warranty
All products from DPA Microphones are covered by a two-year limited warranty on both mechanical func­tionality and documented specifications as long as the items are not mistreated, abused or modified in any way. In case of a warranty claim your invoice is your warranty reg­istration.
This product is produced by www.spreadcard.com , # 11007
Environmental Policy
This product is comprised by the Waste (WEEE) directive and should not be thrown in the garbage bin when obsolete. Instead, return it to your local DPA representative (or DPA Microphones A/S directly) who will dispose of the product in accordance with the current environmental standards.
RoHS directive: 2002/95/EC WEEE directive: 2002/96/EC
© October 2014, DPA Microphones A/S
Product features and specifications are subject to change without notice.
US Sales Ofce
DPA Microphones, Inc.
1500 Kansas Avenue, Unit 3A
Longmont, CO 80501
Tel: +1 303-485-1025
Fax: +1 303-485-6470
info-usa@dpamicrophones.com www.dpamicrophones.com
info@dpamicrophones.com www.dpamicrophones.com
APAC Sales Oce
DPA Microphones Ltd. Unit 801-2, 8/F, Asia Orient Tower 33 Lockhart Road, Wanchai Hong Kong
Tel: +852 2617 9990 Fax: +852 2617 9887
www.dpamicrophones.com info-apac@dpamicrophones.com
Loading...