At the heart of Meyer Sound's EXP line of cinema products is the Acheron high-performance screen channel loudspeaker. Optimized for installation behind perforated screens, the two­way loudspeaker combines the advantages of self-powered technology and innovative horn design to deliver exceptional, precise coverage for the left, right, and center sound channels for cinema.
The Acheron loudspeaker is available in two full-range models: the Acheron 100, with a 100-degree horizontal by 50-degree vertical horn, which is ideal for wide theatres; and the Acheron 80, with an 80-degree horizontal by 50-degree vertical horn, which is suitable for more narrow theatres and re-recording stages.
The Acheron horn (patent pending) was specifically designed for cinema use and features a very soft roll-off outside the extremely well behaved coverage angle. The horn is fixed within the enclosure to ensure an accurate acoustic crossover, phase response, and an incredibly
Dimensions
Weight
Enclosure
Mounting
31.00" w x 35.00" h x 20.50" d (787 mm x 889 mm x 521 mm)
173 lbs (78.47 kg) Premium birch plywood Low gloss, black textured
Finish
3/8" threaded points on side corners for optional bracket adapters, which allow the Acheron to be mounted to floors with uptilt or downtilt, as well as on top of the Acheron LF (also with uptilt or downtilt)
consistent vertical pattern between the low and high frequencies. The Acheron’s 580 Hz crossover point places most of the dialog in the horn, which is ideal for cinema applications.
Boasting a frequency response of 38 Hz to 17 kHz at
±4 dB
, as well as a generous peak output of 139 dB with very low distortion, the Acheron stands up to the most demanding of digital soundtracks, maintaining a wide dynamic range and full fidelity. Designed and manufactured at Meyer Sound's headquarters in Berkeley, California, the Acheron's drivers include one 15-inch low-frequency neodymium magnet cone driver and one high-frequency 4-inch diaphragm compression driver. The drivers yield uncompromising quality and full bandwidth, making the Acheron suitable for small and medium theatres, re-recording stages, and production and postproduction facilities.
The Acheron's sophisticated onboard amplifica­tion produces consistent and predictable results
in any system design. The proprietary Meyer Sound power amplifier is a two-channel, class AB/H amplifier with complementary MOSFET output stages that yields a total output of 1685 W (3370 W peak). Built-in signal processing includes an electronic crossover and correction filters — to achieve a flat phase and frequency response — along with driver protection circuit­ry. The self-powered design not only ensures consistent results but also simplifies installation in both new and existing rooms.
The optional RMS™ remote monitoring system allows comprehensive monitoring of system parameters on a Windows®-based computer.
Strategically placed 3/8-inch threaded points on the side corners of the Acheron cabinet allow the unit to be fixed to floors with uptilt or downtilt using optional mounting brackets. The Acheron can also be mounted on top of the Acheron LF loudspeaker, also with uptilt or downtilt, using optional stacking brackets.
Exceptional fidelity and extended high­frequency performance
Constant-Q horn yields uniform response throughout the coverage area
Extraordinarily flat amplitude and phase response for tonal accuracy
Wide horn coverage available for larger, wider rooms with the Acheron 100
Narrow, focused coverage available for smaller rooms with the Acheron 80
Seamless integration with the Acheron LF loudspeaker and HMS-10 surround loudspeaker
ApplicationsFeatures & Benefits
Small to medium-sized theatres
Larger theatres with use of Acheron LF
Re-recording stages
Production and postproduction studios
Acheron LCR System with Acheron LF
Network
Remote Monitor System
ytivi
tcA
teseR
kniW
ecivreS
High Limit
Low Limit
Active
TruPower
ACHERON
P
U
S
H
R
E
-
C
I
R
K
-
I T
P
U
S
H
R
E
-
C
I
R
K
-
I T
1
Case
220K
ESD
Earth/Chassis
10K Balanced
3-
2+
LoopInput
2 231 1
3
Meyer Sound, Berkeley, CA, USA
THIS PRODUCT MUST BE GROUNDED
WARNINGS:
clearance from this surface and adequate ventilation. To reduce the risk of electric shock do not remove cover.
To reduce the risk of fire or electric shock
Refer servicing to qualified personnel.
No operator or serviceable parts inside.
do not expose this appliance to rain or moisture.
To ensure proper operation, allow at least 6 inches
ACHTUNG:
ATTENTION:
UND REPARATUR NUR DURCH ELEKTROFÃCHKRAFTE
INTERNES NE SONT AUTORISEES QU'AU
AUTHORIZADO A PERSONAL TÉCNICO CALIFICO
ATENCIÓN:
This surface may reach high tempuratures white in use.
Auto-Voltage Select 95-125V ~ 208-235V~
1400W RMS MAX 1400W RMS MAX
50-60Hz 50-60Hz
U.K. WARNING:
REFER SERVICING TO QUALIFIED PERSONNEL.
NO OPERATOR SERVICEABLE PARTS INSIDE.
Turn on 165V~ Turn off 264V~
Turn on 85V~ Turn off 134V~
Operational Voltage Range:
PERSONNEL TECHNIQUE QUALIFIÉ
THIS APPARATUS MUST BE EARTHED.
ENTRETIENET REPARATIONS
GEHÃUSE NICHT OFFENE WARTUNG
ACCESO INTERNO SOLO
To meet the SPL require­ments for large rooms, the Acheron 80 and Acheron 100 can be daisy-chained with the Acheron LF loudspeaker, which has been carefully designed so its frequency and phase responses compliment the Acheron.
The Acheron LF has the same low end frequency response as the Acheron (38 Hz) and rolls off at 320 Hz to avoid any interference in the cross­over region of the Acheron. This coupling is optimized to allow a single parametric filter to achieve a flat frequency response with approximately 10 dB more of headroom in the low frequencies (depend­ing on the room acoustics and loading conditions).
Right
Center
Left
Cinema Screen
Acheron 80
Acheron 80/100 Architect Specifications
The loudspeaker shall be a self-powered, full-range system; the transducers shall consist of a 15-inch diameter cone driver and 4-inch diaphragm compression driver. Two horn options shall be available: 80-degree horizontal by 50-degree vertical, and 100-degree horizontal by 50-degree vertical. The loudspeaker system shall incorporate internal processing electronics and a two-channel amplifier, one channel for each driver. Processing functions shall include frequency and phase correction, signal division, and protection for the low- and high-frequency sections. The crossover point shall be 580 Hz.
Each amplifier channel shall be class AB/H with complementary MOSFET output stages. Burst capability for the low-frequency channel shall be 1125 watts total with a nominal 4-ohm resistive load and 560 watts for the high-frequency channel with a nominal 8-ohm resistive load. Total burst power shall be 1685 watts (3370 watts peak). Distortion (THD, IM, TIM) shall not exceed 0.02%. Performance specifications for a typical
production unit shall be as follows, measured at 1/3-octave resolution: operating frequency range shall be 37 Hz to 18 kHz; phase response shall be ±30° from 700 Hz to 17 kHz; maximum peak SPL shall be 139 dB at 1 meter, free field.
The audio input shall be electronically balanced with a 10 kOhm impedance and accept a nominal 10 dBV (3.2 V rms, 4.5 V peak) signal. Connectors shall be XLR (A-3) type male and female. RF filtering shall be provided, and CMRR shall be greater than 50 dB from 50 Hz to 500 Hz.
The internal power supply shall perform automatic voltage selection, EMI filtering, soft current turn-on, and surge suppression. Power requirements shall be nominal 100 V, 110 V, or 230 V AC line at 50 or 60 Hz. UL and CE operating voltage ranges shall be 100 to 240 V AC. Maximum peak current draw during burst shall be 6.4 A at 115 V AC, 3.2 A at 230 V AC, and
7.2 A at 100 V AC. Current inrush during soft turn-on shall not
Acheron 80 Horn
80-degree horizontal by 50-degree vertical coverage
Acheron 100 Horn
100-degree horizontal by 50-degree vertical coverage
Circuit
breakers
Limit LEDs
Power LED
Acheron Rear Panel
Audio input and
loop output
connectors
exceed 7 A at 115 V AC, 7 A at 230 V AC, and 10 A at 100 V AC. AC power connectors shall be locking NEMA L6-20 male inlet or IEC 309 male inlet.
The loudspeaker system shall include support for the optional RMS remote monitoring system module.
All loudspeaker components shall be mounted in an acoustically vented enclosure constructed of premium birch plywood with a black textured finish. Dimensions shall be 31.00" wide x 35.00" high x 20.50" deep (787 mm x 889 mm x 521 mm). Weight shall be 173 lbs (78.47 kg). Optional bracket adapters shall allow the Acheron to be fixed to floors, as well as on top of the Acheron LF, with uptilt or downtilt
The loudspeaker shall be the Meyer Sound Acheron.
RMS user panel
(optional)
AC power
connector (NEMA
L6-20 shown)
Loading...