1
Overview printer
1
2
3
54
1
3
5
On/Off Switch
Control panel
Power connection
Pilot lamp – status indicator
2
Interface connector
4
2
Overview functions
C
F
M+
M+
KeyP25P26P28
• Paper feed
• Menu option (+
On switch)
–• Zeroing / taring the balance
• Paper feed
• Scroll up menu option
• Abort – exit
• Paper feed
• Scroll up menu option
• Zeroing / taring the balance
• Abort – exit
–• Printout of date and time
• Scroll down menu option
–• Printing of stable weight values
• Opening the menu – select next
menu option
• Save settings
• Printout of date and time
• Scroll down menu option
• Printing of stable weight values
• Opening the menu – select next
menu option
• Save settings
––• Totaling application
––• Statistics application
3
4
User Manual Printer
English
Benutzerhandbuch
Manual de usuario
Guide de l'utilisateur
简明用户手册
ユーザマニュアル
Deutsch
Español
Français
中文
日本語
1 Safety Information
Two documents named "User Manual" and "Operating Instructions" are available for this instrument.
• The User Manual shows you how to start using the instrument.
• The Operating Instructions contain a full description of the instrument and its use.
• Keep both documents for future reference.
• Include both documents if you transfer the instrument to other parties.
Only use the instrument according to the User Manual and the Operating Instructions. If you do not use the
instrument according to these documents or if the instrument is modified, the safety of the instrument may
be impaired and Mettler-Toledo GmbH assumes no liability.
Additional information about this printer can be found in the Operating Instructions (OI) online.
uwww.mt.com/printer-p-20-OI
1.1 Definitions of signal words and warning symbols
Safety notes contain important information on safety issues. Ignoring the safety notes may lead to personal
injury, damage to the instrument, malfunctions and false results. Safety notes are marked with the following
signal words and warning symbols:
Signal words
WARNING
CAUTION
NOTICE
Warning symbols
Electrical shock
A hazardous situation with medium risk, possibly resulting in death or severe injury if
not avoided.
A hazardous situation with low risk, resulting in minor or moderate injury if not
avoided.
A hazardous situation with low risk, resulting in damage to the instrument, other
material damage, malfunctions and erroneous results, or loss of data.
en
General hazard: read the Operating Instructions for information about the hazards and the
resulting measures.
1.2 Product specific safety notes
Intended use
This instrument is designed to be used in laboratories by trained staff. The instrument is intended for print
out protocol purposes.
Any other type of use and operation beyond the limits of technical specifications without written consent from
Mettler-Toledo GmbH is considered as not intended.
Responsibilities of the instrument owner
The instrument owner is the person holding the legal title to the instrument and who uses the instrument or
authorizes any person to use it, or the person who is deemed by law to be the operator of the instrument.
The instrument owner is responsible for the safety of all users of the instrument and third parties.
METTLER TOLEDO assumes that the instrument owner trains users to safely use the instrument in their
workplace and deal with potential hazards. METTLER TOLEDO assumes that the instrument owner provides
the necessary protective gear.
3Printer
Safety notes
WARNING
Danger of death or serious injury due to electric shock!
Contact with parts that carry a live current can lead to death or injury.
1 Only use the METTLER TOLEDO power supply cable and AC/DC adapter designed for your
instrument.
2 Connect the power cable to a grounded power outlet.
3 Keep all electrical cables and connections away from liquids and moisture.
4 Check the cables and power plug for damage and replace damaged cables and power
plugs.
NOTICE
Risk of damage to the instrument due to the use of unsuitable parts!
Using unsuitable parts with the instrument can damage the Instrument or cause it to
malfunction.
− Only use parts from METTLER TOLEDO that are intended to be used with your instrument.
2 Installation and Putting into Operation
Finding more information
Additional information about this printer can be found in the Operating Instructions (OI) online.
Search for documents.
u www.mt.com/printer-p-20-OI
u www.mt.com/library
2.1 Scope of delivery
NOTICE
Risk of damage to the instrument due to the use of unsuitable parts!
Using unsuitable parts with the instrument can damage the Instrument or cause it to
malfunction.
− Only use parts from METTLER TOLEDO that are intended to be used with your instrument.
• AC/DC adapter
• Power cable (country specific)
• Operating Instructions or User Manual; printed or online, depending on country of use
• Declaration of conformity
4Printer
2.2 Connecting the printer to the power supply
I/O
ïð
WARNING
Danger of death or serious injury due to electric shock!
Contact with parts that carry a live current can lead to death or injury.
1 Only use the METTLER TOLEDO power supply cable and AC/DC adapter designed for your
instrument.
2 Connect the power cable to a grounded power outlet.
3 Keep all electrical cables and connections away from liquids and moisture.
4 Check the cables and power plug for damage and replace damaged cables and power
plugs.
NOTICE
Danger of damage to the AC/DC adapter due to overheating!
If the AC/DC adapter is covered or in a container, it is not sufficiently cooled and will overheat.
1 Do not cover the AC/DC adapter.
2 Do not put the AC/DC adapter in a container.
The printer is supplied with a universal AC/DC adapter or an AC/DC adapter with a country-specific power
cable.
• Install the cables so that they cannot be damaged or interfere with operation.
• Insert the power cable in a grounded power outlet that is easily accessible.
1 Connect the AC/DC adapter to the connection socket
on the back of the printer.
2 Lock the connector with the screw nut.
3 Connect the 3-pin grounded power cable to the socket
for the AC/DC adapter.
4 Connect the printer and the balance with the interface
cable.
5 Switch the balance on.
6 Connect the printer to the power supply.
7 Switch on the printer with the I/O switch.
en
Note
RS232 interface only: the pilot lamp will flash until an instrument is connected. If the lamp is still flashing
check the chapter Troubleshooting in the Operating Instructions.
5Printer
2.3 Inserting paper
1
2
3
4
On
1 Remove paper cover (pull on the back) (1).
2 Insert the paper rotary axis through the core of the
paper roll (2).
3 Feed paper through the slot in the printing unit in the
direction of the arrow (3).
4 Press and hold until enough paper has been fed (4).
5 Lead paper through the paper cover slot.
6 Place the paper cover (1) on.
If, after the first printouts the connection settings
(Bauderate, Bit, Handshake) of the balance change, the
printer must be restarted. Switch off / on to start the auto
bauderate detection again. Auto bauderate can be switched off.
*8 Bit No 8b-no
7 Bit Odd 7b-odd
7 Bit Even 7b-E
7 Bit No 7b-no
Handshake
*Xon/Xoff HS oFF
HS Soft HS Soft
HS Hard HS HArd
Char Set
*IBM/DOS dOS
IBM/DOS Cyrillic dOS CYr
IBM/DOS Japanese dOS JAP
Ansi/Win Latin 1 II in LAt
Ansi/Win Cyrillic II in CYr
Ansi/Win Japanese II in JAP
Tare/Zero
*Zero ZEro
Tare tArE
Settings
Header
Date Day**
Date Month**
Date Year**
Time Minute**
Time Hour**
Date Format***
Time Format***
Baud rate
Bit/Parity
Handshake
Char Set
Tare/Zero
Menu Option
Factory Setting
Examples if balance display is
used:
10Printer
*factory settings
**
***
instruments with built-in clock: not applicable, built-in clock
has priority
instruments with built-in clock: format of printer has priority
Example for setting the day (P26 / P 28 only)
3
¿
M+
M+
Open the menu
− Hold down the F key until Reset appears.
− Select the menu option Day with the F key.
− Select the day, e.g. day 21.
Scroll up with the h key.
Scroll down with the
key.
Save the settings
− Hold down the F key until Stored appears.
Statistics application (P28 only)
Sample weight must be in the range of 70% - 130% of the current average value.
Minimum dynamic weight changed must be 100 d.
1 Press M+ to start the Statistics application (LED on).
2 Add a new sample and press M+.
3 Press F to print subtotal, if needed.
4 Press and hold M+ to print and end the Statistics application (LED off).
Note
• Unit change during the application is not permitted.
• Maximal 999 sample.
Totaling application (P28 only)
Minimum weights + 1 d.
1 Press M+ to start the Totaling application (LED on).
2 Add a new sample and press M+.
3 Press F to print subtotal, if needed.
4 Press and hold M+ to print and end the Totaling application (LED off).
Note
• Unit change during the application is not permitted.
• Maximal 999 sample.
en
5 Maintenance
5.1 Cleaning and servicing
Since the printer housing is made of top grade, resistant materials, all commercially available mild cleaning
agents may be used.
11Printer
Please observe the following notes
1
2
WARNING
Danger of death or serious injury due to electric shock!
Contact with parts that carry a live current can lead to death or injury.
1 Only use the METTLER TOLEDO power supply cable and AC/DC adapter designed for your
instrument.
2 Connect the power cable to a grounded power outlet.
3 Keep all electrical cables and connections away from liquids and moisture.
4 Check the cables and power plug for damage and replace damaged cables and power
plugs.
NOTICE
Risk of damage to printer due to inappropriate cleaning methods
The printer housing is made from high quality, resistant materials and can be damaged by
certain cleaning agents, solvents or abrasives. Any liquid that enters the housing may
damage the printer.
1 Use water and a mild detergent to clean the printer.
2 Wipe off any spills immediately.
3 Prevent liquid from entering the interior of the printer.
Contact a METTLER TOLEDO representative to find about the service options available – regular maintenance
by an authorized service engineer will ensure consistent weighing accuracy over the long term and extend
the service life of the instrument.
5.2 Replacing the paper roll
The insertion of the new paper roll is described in chapter [Inserting paper}Page6]. The order number for
the paper roll can be found in chapter Consumables in the Operating Instructions.
Note
The paper rotary axis must always be transferred from the old paper roll to the new one.
5.3 Replacing the ribbon
The order number for the ribbon cartridge can be found in chapter Consumables in the Operating
Instructions.
1 Remove the paper cover (1).
2 Pull paper out of printing unit (2).
12Printer
4
3
3 Remove ribbon cartridge, by pressing in arrow
direction (3).
4 Insert the new ribbon cartridge. If necessary, take up
slack with tensioning wheel (4).
Insertion of a new paper roll is described in chapter
[Inserting paper}Page6].
6 Technical Data
6.1 General technical data
WARNING
Risk of electric shock
Contact with parts that contain a live current can lead to injury and death.
1 Only use an approved AC/DC adapter with a current-limited SELV output.
2 Ensure correct polarity
Power supply
AC/DC adapter:Primary: 100 – 240 V, 50/60Hz
Cable for AC/DC adapter:3-core, with country-specific plug
Power line voltage:12 V DC
Power consumption:Max. 1 A
Protection and standards
Overvoltage category:II
Degree of pollution:2
Standards for safety and EMC:See Declaration of Conformity
Range of application:For use only in closed interior rooms
Environmental conditions
Height above mean sea level:up to 4000 m
Ambient temperature range:Operation: 0°C ~ 40°C
Relative air humidity:10% up to 80% at 31°C decreasing linearly to 50% at 40°C,
Printer features
Print technology:Dot matrix printer 5 × 7, 24-character line length
Print speed:2.3 lines per second
Ribbon cartridge:Exchangeable, black
Paper roll:Standard paper 57.5 mm × ø 50 to 60 mm, integrated in
Print quality:Light resistant and thermally stable printing (GLP, GMP,
Secondary: 12 V DC, 2.5 A (with electronic overload
protection)
Storage: -25°C ~ 60°C
non-condensing
housing, commercial size
ISO9001)
en
13Printer
Interfaces:RS‑P25, RS‑P26,
RS232C
RS‑P28
USBUSB
Compatibility limits:• Function Date / Time: not applicable on balances with built-
in clock (built-in clock has priority)
• Function Zeroing / Taring: not applicable on all models of
balances
Dimension / weight
Printer dimensions (W × D × H):120 × 203 × 73 mm
Packaging dimensions (W × D ×
255 × 205 × 150 mm
H):
Net weight:740 g (paper roll incl.)
14Printer
1 Sicherheitshinweise
1.1 Erklärung der Warnhinweise und Symbole
1.2 Produktspezifische Sicherheitshinweise
2 Inbetriebnahme der Waage
Sehen Sie dazu auch
2.1
2 }Seite15
2.2
2.3
3
4
4.1
4.2
5
5.1
5.2
Sehen Sie dazu auch
5.3
2 }Seite15
6
6.1
de
15
16
1 Información de seguridad
1.1 Definición de los símbolos y las señales de advertencia
1.2 Información de seguridad sobre el producto
2 Instalación de la balanza
Vea también a este respecto
2.1
2 }página17
2.2
2.3
3
4
4.1
4.2
5
5.1
5.2
Vea también a este respecto
5.3
2 }página17
6
es
6.1
17
18
1 Informations liées à la sécurité
1.1 Définition des avertissements et symboles
1.2 Informations liées à la sécurité produit
2 Réglage de la balance
Voir aussi à ce sujet
2.1
2 }page19
2.2
2.3
3
4
4.1
4.2
5
5.1
5.2
Voir aussi à ce sujet
5.3
2 }page19
6
6.1
fr
19
20
1
安全信息
1.1
提示警告与符号定义
1.2
产品安全信息
2
安装天平
为此请也参阅
2.1
2 }第21页
2.2
2.3
3
4
4.1
4.2
5
5.1
5.2
为此请也参阅
5.3
2 }第21页
6
6.1
zh
21
22
1
安全性について
1.1
注意喚起およびアイコンの定義
1.2
製品安全性情報
2
天びんのセットアップ
以下も参照してください
2.1
2 }23ページ
2.2
2.3
3
4
4.1
4.2
5
5.1
5.2
以下も参照してください
5.3
2 }23ページ
6
6.1
ja
23
24
Mettler-Toledo GmbH
30419762
Im Langacher 44
8606 Greifensee, Switzerland
www.mt.com/contact