Mettler Toledo ID7sx-Sys Operating Instructions Manual

Operating instructions
METTLER TOLEDO MultiRange ID7sx-Sys weighing terminal
www.mt.com/support
Contents
Contents
Page
1 Safety precautions....................................................................... 4
2 Introduction and commissioning................................................... 5
2.1 Documentation............................................................................. 5
2.2 Applications ................................................................................. 5
2.3 ID7sx-Sys weighing terminal.......................................................... 6
2.4 Commissioning ............................................................................ 8
2.5 Cleaning...................................................................................... 8
2.6 Disposal...................................................................................... 8
3 Basic functions............................................................................ 9
3.1 Setting to zero .............................................................................. 9
3.2 Taring ......................................................................................... 9
3.3 Weighing..................................................................................... 10
3.4 Working with several weighing platforms......................................... 10
3.5 Displaying versions ...................................................................... 11
4 Additional functions..................................................................... 12
4.1 Display ID code and test weighing platform ..................................... 12
4.2 Recall information......................................................................... 13
4.3 Recall data from Alibi Memory........................................................ 14
5 Settings in the master mode ........................................................ 17
5.1 Overview of the master mode ......................................................... 17
5.2 Operating the master mode............................................................ 18
5.3 TERMINAL master mode block........................................................ 20
5.4 SCALE master mode block ............................................................. 22
5.5 INTERFACE master mode block ...................................................... 25
6 What to do if....? ......................................................................... 27
7 Technical data and accessories .................................................... 29
7.1 Technical data.............................................................................. 29
7.2 Accessories.................................................................................. 31
8 Index .......................................................................................... 33
Operating instructions 22016401 06/09 3
Safety precautions

1 Safety precautions

The ID7sx-Sys weighing terminal is approved for operation in zone 1 and 21 hazardous areas. It may only be used in areas in which the causes of static electricity build-up, which lead to propagating brush discharges, have been eliminated. If the ID7sx-Sys weighing terminal is used in hazardous areas, special care must be taken. The code of practice is oriented to the "Safe Distribution" concept drawn up by METTLER TOLEDO.
Competence ▲ The weighing system may only be installed, maintained and repaired by
authorised METTLER TOLEDO service personnel.
The mains connection may only be connected or disconnected by the owner’s
electrician.
Ex approval ▲ For the exact specification please refer to the statement of conformity.
ID7sx-Sys
No modifications may be made to the terminal and no repair work may be per-
formed on the modules. Any weighing platform or system modules that are used must comply with the specifications. Non-compliant equipment jeopardises the intrinsic safety of the system, cancels the Ex approval and renders any warranty or product liability claims null and void.
The safety of the weighing system is only guaranteed when the weighing system
is operated, installed and maintained in accordance with the respective instructions.
Also comply with the following:
– the instructions for the system modules – the regulations and standards in the respective country – the statutory requirement for electrical equipment installed in hazardous areas
in the respective country
– all instructions related to safety issued by the owner
The explosion-protected weighing system must be checked to ensure compliance
with the requirements for safety before being put into service for the first time, following any service work and every 3
Operation ▲ Prevent the build-up of static electricity. Therefore:
– always wear suitable working clothes when operating or performing service
work on the system,
– do not rub or wipe off the keyboard surface with a dry cloth or glove.
Do not use protective hoods.
years, at least.
Prevent damage to the weighing terminal. Hairline cracks in the keyboard
membrane are also considered damage.
4 Operating instructions 22016401 06/09

2 Introduction and commissioning

2.1 Documentation

These operating instructions describe the operation of the ID7sx-Sys with the basic functions of the Sys-690 application software and all the possible interfaces. Information on your customer-specific ID7sx-Sys application can be found in the corresponding operating instructions specially authored for you.

2.2 Applications

With the ID7sx-Sys weighing terminals the following applications are possible:

2.2.1 ID7sx-Sys with PSU power supply unit

Introduction and commissioning
RS232
CL
I/O
PSU
CL
ID7sx
K...x / DN...x/
PUA...x/PTA...x
Point Ex
system solution
PBA430x/
Analog scale
In this configuration the following possibilities are available:
• Multi-scale operation with up to 3 weighing platforms (K...x, DN...x, PUA...x, PTA...x, PBA430x or system solution Point Ex)
• Up to 2 data interfaces and one I/O interface
– for printing, – for data exchange with a computer, – for control, e.g. of valves or flaps.
• Alibi memory module for storing the individual configuration data as well as weighing data.
Operating instructions 22016401 06/09 5
Introduction and commissioning

2.2.2 ID7sx-Sys with PSUx power supply unit

ID7sx-Sys
ID7sx
PSUx
Only one weighing platform (K...x, DN...x, PUA...x, PTA...x, PBA430x or Point Ex system solution) is permissible in this configuration.

2.3 ID7sx-Sys weighing terminal

2.3.1 Display

12
MODE
3 4 5 6
7
1 Weight display BIG WEIGHT® with sign and decimal point
2 Stability monitor: lights up until the weighing platform has levelled out, then the
weight unit appears here
3 Range display for multi-range weighing platforms
4 Number of the weighing platform: shows the weighting platform just selected
5 Symbol * for identifying weight values in the second unit or in a higher
resolution
6 NET symbol for marking net weight values
7 Assignment of the function keys
6 Operating instructions 22016401 06/09
Introduction and commissioning

2.3.2 Keypad

1 CODE A ... CODE D keys – enter identification data 2 FUNCTION CHANGE key – display additional functions
when entering weight values: switch over unit
3 INFO key – recall memory contents and system information
4 Function keys F1 … F6 – the current assignment is shown in the display above
the key
5 SCALE key – select scale
6 ZERO-SET key – set scale to zero, test scale
7 TARA key – tare scale
8 TARE SPECIFICATION key – enter known tare values numerically
9 CLEAR key – clear entries and values
10 ENTER key – accept and transfer data
11 Numeric keypad with decimal point and signs
Operating instructions 22016401 06/09 7
Introduction and commissioning

2.4 Commissioning

2.4.1 Control drawings and guides for installers

ID7sx-Sys
The explosion-protected weighing system with the ID7sx-Sys weighing terminal may only be installed according to the respective guide for installers and the accompanying control drawing, depending on the power supply unit.
Component Guide for installers Control drawing
ID7sx ME-22008316
PSU ME-22006472
PSUx/230V ME-22006386 PSUx/230V-ID7sx
PSUx/120V ME-22006395 PSUx/120V-ID7sx

2.5 Cleaning

DANGER OF SHOCK
Do not open ID7sx-Sys weighing terminal to clean.
CAUTION
Make sure that unused connection sockets are covered with the corresponding
protective caps. Ensure the correct position of the seals when doing so.
Do not use high-pressure cleaners.
Cleaning
PSU-ID7sx ME-22006478
ME-22006397
ME-22006399
Wipe off ID7sx-Sys weighing terminal with a commercially available glass or
plastic cleaner.
When used in category 2, zone 21 hazardous areas, the weighing terminal must
be cleaned regularly. See also standard EN 50281-1-1 / 50281-1-2.

2.6 Disposal

In conformance with the European Directive 2002/96 EC on Waste Electrical and Electronic Equipment (WEEE) this device may not be disposed of with domestic waste. This also applies to countries outside the EU, per their specific requirements.
Please dispose of this product in accordance with local regulations at the
collecting point specified for electrical and electronic equipment.
If you have any questions, please contact the responsible authority or the distributor from which you purchased this device. Should this device be passed on to other parties (for private or professional use), the content of this regulation must also be related. Thank you for your contribution to environmental protection.
8 Operating instructions 22016401 06/09

3 Basic functions

3.1 Setting to zero

Setting to zero corrects the influence of minor dirt on the load plate. In the case of excessive dirt which cannot be compensated by setting to zero, the display shows OUT OF RANGE.
Manual zero set 1. Relieve weighing platform.
2. Press ZERO-SET key.
The display shows 0.000 kg.
Automatic zero set On certified weighing platforms the zero point of the weighing platform is automati-
cally corrected when the weighing platform is relieved. The automatic zero set can be switched off in the master mode on non-certified weighing platforms.
Basic functions

3.2 Taring

3.2.1 Manual taring

1. Place empty container on scale.
2. Press TARE key.
The tare weight is saved and the weight display set to zero. The display shows the NET symbol.
Notes
• When the weighing platform is relieved, the saved tare weight is displayed with a negative sign.
• The weighing platform only saves one tare value.

3.2.2 Specify tare weight

This function is only available when ordered expressly.
Enter numerically 1. Press TARE SPECIFICATION key.
2. Enter tare weight (container weight) and confirm with ENTER.
When weighing platform is relieved, the entered tare weight is displayed with a negative sign.
Note
With the FUNCTION CHANGE key you can select the weight unit for entering the tare weight.
Correct entry ➜ Clear the entry character by character with CLEAR key and repeat correctly.
Operating instructions 22016401 06/09 9
Basic functions

3.2.3 Recall currently saved tare weight

The saved tare weight can be recalled at any time. Enter INFO, TARE SPECIFICATION key sequence.
The saved tare weight is displayed.

3.2.4 Clear tare weight

Relieve weighing platform and tare.
– or –
Recall tare weight and press CLEAR key.

3.3 Weighing

Weighing without taring Lay weighing sample on weighing platform.
Gross weight (total weight) is displayed.
ID7sx-Sys
Weighing with taring 1. Place the empty container on the weighing platform and tare.
2. Pour in weighing sample.
The display shows the net weight and the NET symbol.
Weighing with tare
specification
1. Place filled container on weighing platform.
The display shows the gross weight (total weight).
2. Specify tare weight or recall tare memory.
The display shows the net weight (container content) and the NET symbol.

3.4 Working with several weighing platforms

Up to 3 weighing platforms can be connected to the ID7sx-Sys. Depending on the setting in master mode, only the currently active scale appears in the display (serial Multi-scale mode) or all scales are operated at the same time (parallel multi-scale mode). A constantly updated sum scale is also available in parallel multi-scale mode.

3.4.1 Switch over weighing platform

The weighing platform currently selected is shown on the terminal. Press SCALE key.
The next weighing platform is selected.
– or – Enter number of weighing platform and press SCALE key.
The desired weighing platform is selected.
Note
The sum scale can only be operated non-verifiably. It is therefore identified by the symbol
10 Operating instructions 22016401 06/09
Σ.
Basic functions

3.5 Displaying versions

When connected to a power supply, the versions of the ID7sx-Sys and the installed components are displayed.
Version code for the ID7sx-Sys with customer-specific application program
METTLER-TOLEDO ID7sx-Sys
ID7sx 0.13
CC-AA-XXXXXXXX-WV-DD.MM.YYYY
CC Country code, e.g. DE = Germany AA Software type, e.g. 00 = Base XXXXXXXXXX Order No. VVV Software version DD.MM.YYYY Date of manufacture, day.month.year
Operating instructions 22016401 06/09 11