Congratulations on choosing the quality and precision of METTLER TOLEDO. Proper use
according to these instructions and regular calibration and maintenance by our factorytrained service team ensure dependable and accurate operation to protect your investment.
Contact us about a ServiceXXL agreement tailored to your needs and budget.
We invite you to register your product at
www.mt.com/productregistration
so we can contact you about enhancements, updates and important notications concern
9.5 Index .................................................................................................................88
4
METTLER TOL EDO User manual ICS465
04/12Order number 22023406A
1 Introduction
1.1 Safety instructions
General
▲ Do not use the device in a hazardous environment. Special devices are available in
our range of products for hazardous environments.
▲ The safety of the device cannot be ensured if it is not operated in accordance with
these operating instructions.
▲ Only authorised personnel may open the device.
Devices with protection level IP65
Devices with protection level IP65 are dust-tight and protected from water jets according to
EN 60529. They are suitable for use in dusty environment and brief contact with liquids.
▲ Ensure that the device is dried off again after coming into contact with liquid.▲ Do not use the device in environments with a risk of corrosion.▲ Do not ood the device or submerge it in liquid.
Devices with built-in power supply unit
▲ Ensure that the power socket outlet for the device is earthed and easily accessible, so
that it can be de-energised rapidly in emergencies.
▲ Ensure that the supply voltage at the installation site lies within the range of 100V
to 240V.
▲ Check the power cable regularly for damage. If it is damaged, immediately disconnect
the device from the power supply unit.
Devices with built-in storage battery
▲ Only use storage batteries from the manufacturer.▲ Do not use the battery charger in humid or dusty rooms or below 0 °C (32 °F)
ambient temperature.
▲ After the storage battery has been charged, the cover cap of the charging socket at the
device must be closed.
Compact scales
▲ Avoid falling loads, shock loads as well as impacts from the side.
METTLER TOL EDO User manual ICS46504/12Order number 22023406A
5
Introduction
1.2 Presentation
1.2.1 Weighing terminals
There are two versions of the ICS465 weighing terminal:
ICS465awith analog scale interface:
to connect analog weighing platforms
ICS465dwith digital scale interface SICSpro, which is based on RS422:
to connect METTLER TOLEDO weighing platforms with digital scale
interface SICSpro, e.g., PBD 655
1.2.2 Compact scales
A compact scale consists of a weighing terminal with digital scale interface SICSpro and a
weighing platform which are xed together.
Depending on the connected weighing platform there are two basic versions of the ICS465
compact scales:
ICS465d-.../f ICS465 compact scale with strain gauge load cell
ICS465k-.../f ICS465 compact scale with MonoBloc® load cell
The weighing platforms are available in three different sizes as shown below.
ICS465d-...XS/f
ICS465k-...XS/f
ICS465k-...XS/DR/f
extra small weighing platformsmall weighing platformlarge weighing platform
Naming
The complete name of a compact scale also indicates the type, size and capacity of the
connected weighing platform. E.g., ICS465k-6SM/DR/M/f stands for
ICS465k ICS465 terminal, weighing platform with MonoBloc
6 weighing capacity in kg
SM size of the weighing platform
DR if present: Delta Range weighing platform
M if present: weighing platform veried by the manufacturer
/f mechanical design: xed connection
ICS465d-...SM/f
ICS465k-...SM/f
ICS465k-...SM/DR/f
ICS465d-...LA/f
ICS465k-...LA/f
ICS465k-...LA/DR/f
®
load cell
6
METTLER TOL EDO User manual ICS465
04/12Order number 22023406A
1.2.3 Options
Interfaces
Default equipment
ICS465a / ICS465d weighing terminals
• 1 serial interface RS232
• 1 analog scale interface resp. digital scale interface SICSpro
ICS465d.../f / ICS465k.../f compact scales
• 1 serial interface RS232
• 1 digital scale interface SICSpro
One additional interface is possible.
• RS232 (usable as data interface or SICS scale)
• RS422/485 (usable as data interface or scale interface SICSpro)
• USB Device
• USB Host
• Ethernet
• WLAN
• Digital I/O
• Analog scale
Weighing platform resolutions for compact scales
DefaultOptional
ICS465d-.../f1 x 6,000 d, non-approved1 x 30,000 d, non-approved
1 x 60,000 d, non-approved
1 x 6,000 d, approved, e = d
ICS465k-.../fup to 1 x 610,000 d,
non-approved
up to 1 x 61,000 d, approved,
e=10d
Further options
• Exchangeable storage battery (IP54)
• Built-in storage battery (IP65)
• Alibi memory
METTLER TOL EDO User manual ICS46504/12Order number 22023406A
7
Introduction
1.2.4 Display
To meet your special requirements different display layouts are available in the Terminal
menu.
Straight weighing display
Default layout
1 Metrological data – for details see following table
2 Weight value with star, sign and stability monitor – for details see following table
3 Spanner icon: service needed – for details see Event and error messages
4 Battery symbol
5 Net/Gross
6 Unit
7 Soft keys (factory setting, page 1)
8 Auxiliary data line – the contents is dened in the menu; here: bargraph
9 Symbol and info line – for details see following table
Weight values in 3-line mode
Bargraph
The device offers a bargraph indicating the scale capacity available.
The bargraph indicates roughly which part of the scale capacity is already occupied and
what capacity is still available.
In the example, approx. 3/4 of the scale capacity is occupied, although the applied net
weight isn’t really high. The reason therefore could be a high tare weight.
8
METTLER TOL EDO User manual ICS465
04/12Order number 22023406A
Metrological data line
The metrological data are stored in the weighing platform. The weighing terminal only
serves as indicator.
In the metrological data line the following information is displayed:
SymbolInformationRemark
,
,
, ,
,
Accuracy classesDisplayed only if the scale is approved
according to the Weights and Measures
guidelines
Weighing range
information
For multi range devices only,
displayed only if the scale is approved
according to the Weights and Measures
guidelines
Maximum capacity–
Minimum capacityDisplayed only if the scale is approved
according to the OIML Weights and
Measures guidelines
Approved resolutionOIML: Displayed only if the scale is
approved
NTEP: Displayed only if the scale is
approved and d is different from e
Display resolutionPlease note for approved scales:
OIML: Displayed only if d is different
frome
NTEP: Displayed always
Approved weighing
device
Metrology display disabled,
Weights and Measures data must be
indicated on a label near the weight
display
METTLER TOL EDO User manual ICS46504/12Order number 22023406A
9
Weight value
The weight value can be marked with the following symbols:
SymbolInformationRemark
Introduction
✱
–
1.2343 kg
Symbols and info line
In the symbols and info line the following information can be displayed:
SymbolInformationRemark
l<–>l 1
Calculated weight valueE.g., for average weighing results
SignFor negative weight values
Stability monitorFor unstable weight values
Non-approved last digit
with e > d
Weighing rangeFor multi range or multi interval scales only
Scale number–
Weight below
minimum weight
Average weighingAverage must be activated in the menu
For approved scales only
The example shows the weight value for a
scale with e = 1 g and d = 0.1 g
The last, smaller digit is not approved
MinWeigh must be activated in the menu
>0<
S
Automatic taringAuto Tare must be activated in the menu
Automatic clearing
of the tare weight
Checkweighing to
zero
Center of zero
indication
Automatic APW
optimisation
Totalisation
A-Clear Tare must be activated in the
menu
To zero must be assigned to a soft key in
the menu
Availability depending on local Weights and
Measures regulations
APW optimisation must be set to
Auto
–
10
METTLER TOL EDO User manual ICS465
04/12Order number 22023406A
1.2.5 Keyboard
KeyNameFunction in the operating modeFunction in the menu
Power• Switching on and off
• Cancel editing
Clear• Clear tare
• Leave info page
• Cancel editing
• Exit menu
• Clear value
• Clear digit
• Leave counting
Switch• Switch over weight unit• Re-edit
Zero• Set scale to zero
–
• Clear tare
Tare• Tare scale
–
• Clear tare
Info• Activate info screen
–
• Proceed to next info line / info page
• Freeze and release startup screen
Transfer• Transfer data to a printer or computer • Conrm entry / selection
METTLER TOL EDO User manual ICS46504/12Order number 22023406A
11
1.2.6 Soft keys
To meet your specic application requirements, ICS465 offers 16 soft keys which can be
congured in the Terminal menu. The soft keys are divided into four lines (pages).
Factory setting
Introduction
Page 1
Page 2
Page 3, Page 4
uuu
Reference n
here: 10 pieces
APW
S
TotalisingAlibi memoryScroll to page 3
Pages 3 and 4 are free for customer conguration.
When scrolling from page 4, page 1 is displayed again.
Operating soft keys
➜ Press the key below the desired function.
Average
weighing
Alibi
Checkweighing Scroll to page 2
uuu
12
METTLER TOL EDO User manual ICS465
04/12Order number 22023406A
Soft key options
SymbolMenu settingFunction
Zero
Tare
High resolutionShow the weight value with 10times higher
resolution
ID1,ID2, ID3
Prompt
Alibi
S
Average
weighing
ID1, ID2, ID3Enter identications
PromptStarting a predened workow. The user will be
Alibi memoryCalling up the optional alibi memory
Switch scale
Ref nDetermine the average piece weight
APWEnter the average piece weight
APW
optimisation
Weight/countSwitch between weight display and display of
ToZeroCheckweighing to zero
Totalising
Checkweighing
Start average weighing
guided step by step.
Reference weight optimisation
pieces
Save articleSave the current article parameters in the database
Recall articleRecall parameters from the database
Display layoutSwitch between default weight display and 3-line
mode
METTLER TOL EDO User manual ICS46504/12Order number 22023406A
13
1.2.7 Connections
Introduction
12543
1 AC power supply or battery charging
2 Standard interface COM1 (RS232)
3 Optional interface COM2 incl. digital scale interface SICSpro and SICS scale
4 Weighing platform connection SCALE 2, to connect analog weighing platforms only
5 (Digital) weighing platform connection SCALE 1
The SCALE connections for analog weighing platforms are without plug, but with cable
exit.
1.3 Commissioning
1.3.1 Selecting the location
The correct location is crucial to the accuracy of the weighing results.
➜ Select a stable, vibration-free and, if possible, a horizontal location for the weighing
platform.
The ground must be able to safely bear the weight of the fully loaded weighing platform.
➜ Observe the following environmental conditions:
– No direct sunlight
– No strong drafts
– No excessive temperature uctuations
14
METTLER TOL EDO User manual ICS465
04/12Order number 22023406A
1.3.2 Levelling the weighing platform
Only weighing platforms that have been levelled precisely horizontally provide accurate
weighing results. Weights and Measures approved weighing platforms have a spirit level
to simplify levelling.
➜ Turn the adjustable feet of the weighing platform until the spirit level’s air bubble is
inside the inner circle.
Levelling of compact scales
On compact scales levelling can be done in an easier way.
1. Turn the compact scale upside down.
2. Unscrew the plastic screw in the middle of the terminal front side far enough that it
does support the terminal.
3. Screw in the 2 adjustable feet on the side facing the terminal.
4. Turn over the compact scale into its normal position.
5. Level the compact scale by turning the other 2 adjustable feet of the weighing platform
until the spirit level's air bubble is inside the inner circle.
1.3.3 Weighing platform connection
Analog weighing platforms
➜ Call the METTLER TOLEDO service technician to connect an analog weighing platform
to the ICS465a weighing terminal.
Weighing platforms with digital scale interface SICSpro
➜ Connect the weighing platform connector to the ICS465d weighing terminal.
• If you have ordered an approved weighing system consisting of an ICS465d weighing
terminal and an approved PBD... weighing platform, the approval was done in the
factory.
• Due to the new digital scale interface SICSpro, you can disconnect the weighing
platform from the weighing terminal of an approved weighing system without violating
the approval.
– If another weighing platform is connected to the weighing terminal, the system is
not approved.
– If the weighing platform of the approved system is connected again, the approval
is valid again.
• If you have connected a non-approved weighing platform and want to approve the
system, call the METTLER TOLEDO service technician.
METTLER TOL EDO User manual ICS46504/12Order number 22023406A
15
Introduction
1.3.4 Power supply connection
CAUTION
Risk of electric shock!
▲ Before connecting the power supply, check whether the voltage value printed on the
rating plate corresponds to your local system voltage.
▲ Do not under any circumstances connect the device if the voltage value on the rating
plate deviates from the local system voltage.
▲ Make sure the weighing platform has reached room temperature before switching on
the power supply.
➜ Plug the power plug into the power socket.
After it has been connected, the device runs a self-test. The device is ready to operate
when zero appears on the display.
1.3.5 Handling of the storage battery
Note the following when operating a device with a built-in storage battery:
• The operating life depends on the intensity of use, the conguration and the connected
scale. For details see the technical data.
• The battery symbol shows the current state of charge of the storage battery.
– One segment corresponds with approx. 25 % capacity.
– If the symbol ashes, the storage battery has to be charged.
– During charging the segments are "running" until the battery is fully charged and
all segments light up continuously.
• The charging time of the storage battery amounts to approx. 6 hours.
The storage battery is protected against overcharging.
• The storage battery has a service life of approx. 2 years or 500 to 1,000 charging/
discharging cycles.
16
METTLER TOL EDO User manual ICS465
CAUTION
No success in charging the storage battery due to low temperatures!
▲ Do not charge the battery if the battery temperature is below 0 °C (32 °F). Charging
is not possible in this temperature range.
▲ Do not operate the battery charger outside its temperature range of 0 °C to 40 °C
(32°F to 104°F).
04/12Order number 22023406A
Recommended use of the storage battery
The characteristics mentioned above are only valid if the following recommendations are
observed:
• Change the battery as soon as the warning message "Lowbattery" appears and the
battery symbol starts ashing. When the message appeares you still have enough
time (at least 10minutes) to complete your current task.
• For optimum battery performance operate the device with built-in storage battery at an
ambient temperature in the range of 10 °C to 30 °C (50 °F to 86 °F). This applies to
discharging as well as charging the battery.
• If you plan to put the scale out of operation for a longer period, charge the battery
completely.
• Even if you do not use the instrument, charge the battery at least every 3months to
avoid deep discharge.
• On devices with removable battery, remove the battery prior to long term storage.
Changing battery
2.
1.
1. Unlock the battery by moving the slider to the outside and remove the discharged
battery.
2. Insert the fully charged battery and secure it by moving the slider to the inside.
With optional IP65 protection, the battery is not accessible from the outside. Please call
the METTLER TOLEDO service technician.
METTLER TOL EDO User manual ICS46504/12Order number 22023406A
17
Operation
2 Operation
2.1 Switching on and off
2.1.1 Switching on/off
Switching on
➜ Press .
For a few seconds the device shows a start-up screen with device name, software
version, serial number of the weighing terminal and the Geo value (not for MonoBloc
weighing platforms).
• You can freeze the start-up screen by pressing .
• When you start a compact scale, the metrology line shows whether it is approved or
not. If you have ordered an approved compact scale, approval has been done in the
factory already.
• When user management is active, you are asked to select your name and enter the
corresponding password.
®
Switching off
2.1.2 Resetting
➜ Press .
Before the display goes out, -OFF- appears briey.
➜ Press and hold for approx. 5 seconds.
The device is reset and will operate with the last saved settings.
2.2 Simple weighing
1. Place weighing sample on the scale.
2. Wait until the stability monitor goes out.
3. Read the weighing result.
2.3 Switching units
If an additional second weight unit is congured in the menu, it is possible to switch back
and forth between the two weight units.
➜ Press .
The weight value is displayed in the second unit.
18
METTLER TOL EDO User manual ICS465
Possible units are g, kg, oz, lb, lb-oz, t and PCS in piece counting.
04/12Order number 22023406A
2.4 Zeroing / Zero point correction
Zeroing corrects the inuence of slight changes on the load plate or minor deviations from
the zero point.
Manual
1. Unload scale.
2. Press .
Zero appears in the display.
Automatic
In case of nonveried scales, the automatic zero point correction can be deactivated in
the menu or the zero range can be changed. Approved scales are set xed to 0.5 d.
By default, the zero point of the scale is automatically corrected when the scale is unloaded.
• The zero function is only available within a limited weighing range.
• After zeroing the scale, the whole weighing range is still available.
• A successful zeroing will always delete a tare weight.
2.5 Weighing with tare
2.5.1 Taring
➜ Place the empty container on the scale and press .
The zero display and the symbol NET appear.
The tare weight remains stored until it is cleared.
2.5.2 Clearing the tare
➜ Press .
The symbol NET goes out, the gross weight appears in the display.
If the symbol is displayed, i.e., the A-Clear Tare function is activated in the
menu under Scale -> Tare, the tare weight is automatically cleared as soon as the
scale is unloaded.
2.5.3 Automatic clearing of the tare
A tare weight is automatically cleared when the scale is unloaded.
Prerequisite
9 The symbol
is displayed, i.e., the tare function A-Clear Tare is activated in
the Scale menu.
METTLER TOL EDO User manual ICS46504/12Order number 22023406A
19
Operation
2.5.4 Automatic taring
If you place a weight on an empty scale, the scale tares automatically and the symbol
NET is displayed.
Prerequisite
9 The symbol
Scale menu.
The weight to be tared automatically, e.g., packaging material, must be heavier than
9display steps of the scale.
2.5.5 Chain tare
With this function it is possible to tare several times if, e.g., cardboard is placed between
individual layers in a container.
Prerequisite
9 The tare function Chain tare is activated in the Scale menu.
is displayed, i.e., the tare function Auto Tare is activated in the
1. Place the rst container or packaging material on the scale and press
The packaging weight is automatically saved as the tare weight, the zero display and
the symbol NET appear.
2. Weigh the weighing sample and read/print out the result.
3. Place the second container or packaging material on the scale and press
again.
The total weight on the scale is saved as the new tare weight. The zero display
appears.
4. Weigh the weighing sample in the second container and read/print the result.
5. Repeat steps 3 and 4 for other containers.
2.5.6 Tare preset
If you know the weight of your containers, you can enter the tare weight numerically. Thus
you do not have to tare the empty container.
1. Enter the known tare weight and press to conrm.
The weight display shows the negative tare weight and the symbol NET appears.
2. Place the full container on the weighing platform.
The net weight is displayed.
.
20
METTLER TOL EDO User manual ICS465
• The entered tare weight is valid until a new tare weight is entered or the tare weight
is cleared.
• The tare weight can be entered via barcode or SICS command as well.
04/12Order number 22023406A
2.6 Displaying information
Up to 5 different items for display can be congured in the menu for the info key. Depending
on the conguration in the Terminal menu, the following data can be assigned in a
free order, e.g.,
• Date & Time
• Weight values
• Identications
• Device information
• Serial numbers and software versions
On the second and third info page, system and contact information can be displayed.
1. Press .
The (rst) info page is displayed.
2. Press again.
The next info screen is displayed.
3. To leave the info screens, press .
An info screen is displayed until is pressed again or is pressed.
2.7 Printing results
If a printer or computer is connected, weighing results and other information can be printed
or transferred to a computer.
➜ Press .
The dened data is printed or transferred to the computer.
The printout content can be dened in the Templates menu.
METTLER TOL EDO User manual ICS46504/12Order number 22023406A
21
Operation
2.8 Average (dynamic) weighing
With the average weighing function, it is possible to weigh restless weighing samples
such as living animals. If this function is activated, is displayed in the info line.
With average weighing, the scale calculates the mean value from weighing operations
within a certain time interval. The time interval for calculation can be set in the
Application menu.
Start via soft key
(factory setting)
9 Weighing sample heavier than 9 scale divisions.
1. Place the weighing sample on the scale.
2. Press the soft key
During average weighing, stars appear in the display, and the average result will be
displayed with the symbol ✱.
3. Unload the scale to be able to start a new average weighing operation.
2. Press the key dened in the menu to start average weighing.
During average weighing, stars appear in the display, and the average result will be
displayed with the symbol ✱.
3. Unload the scale to be able to perform a new average weighing operation.
9 Application -> Average -> Mode –> Auto is selected in the menu.9 Weighing sample heavier than 9 scale divisions.
1. Place the weighing sample on the scale.
Average weighing starts automatically.
During average weighing, stars appear in the display, and the average result will be
displayed with the symbol ✱.
2. Unload the scale to be able to perform a new average weighing operation.
22
METTLER TOL EDO User manual ICS465
04/12Order number 22023406A
2.9 Workingwithidentications
Weighing series can be assigned 3 identication numbers ID1, ID2 and ID3 with up to
40characters that are also printed out in the protocols. If for example a customer number
and an article number are assigned, it can be clearly seen in the protocol which article
was weighed for which customer.
Direct entry
9 At least one of the soft keys ID1, ID2 or ID3 is activated in the Terminal menu.
1. Press the desired soft key ID1, ID2 or ID3.
The last entered ID is displayed.
2. Enter the ID and conrm with .
The entered ID is assigned to the following weighings until the ID is changed.
Barcodeuse(foroneidenticationonly)
9 ID1, ID2 or ID3 is selected as destination for external input in the Communication
menu.
9 To display the identication, in the Terminal menu ID1, ID2 or ID3 is
9 To display the identication(s), in the Terminal menu ID1, ID2 and/or ID3
is activated for the auxiliary line.
2.10 Working in a higher resolution
The weight value can be displayed in a higher resolution continuously or when called.
Prerequisite
9 Soft key x10 Display is activated in the Terminal menu.
➜ Press soft key x10.
The weight value is displayed in at least 10x higher resolution and is marked with the
symbol ✱.
The higher resolution is displayed until the soft key x10 is displayed again.
With veried weighing platforms, the weight value only appears in a higher resolution as
long as the soft key x10 is pressed.
METTLER TOL EDO User manual ICS46504/12Order number 22023406A
23
Operation
2.11 Working with a prompt
ICS465 offers prompts for often used workows. The weighing terminal will then lead you
from step to step.
In the Application menu one of the following prompts can be activated:
• Tare/Sample
• Sample/Tare
• Hands free
• Multi tare
• Additive tare
During prompting no other soft keys are available.
2.11.1 Tare/Sample
This prompt will guide you through piece counting with rst taring and then determining
the average piece weight.
1. Press the soft key Prompt.
In the soft key line the following is displayed:
2. Load the tare weight and conrm with the soft key below the symbol.
The soft key line changes.
3. Put on the indicated number of reference parts and conrm with the soft key below
the symbol.
The display unit changes to PCS and the soft key line changes.
4. Put on the weighing samples and read the number of pieces.
5. To leave piece counting press the soft key C.
“Cleared” is displayed briey.
If a printer is connected, each individual result can be printed out by pressing .
24
METTLER TOL EDO User manual ICS465
04/12Order number 22023406A
2.11.2 Sample/Tare
This prompt will guide you through piece counting with rst determining the average piece
weight and then taring.
1. Press the soft key Prompt.
In the soft key line the following is displayed:
2. Put on the indicated number of reference parts and conrm with the soft key below
the symbol.
The display unit changes to PCS and the soft key line changes.
3. Load the tare weight and conrm with the soft key below the symbol.
“0 PCS” is displayed and the soft key line changes.
4. Put on the weighing samples and read the number of pieces.
5. To leave piece counting press the soft key C.
“Cleared” is displayed briey.
If a printer is connected, each individual result can be printed out by pressing
2.11.3 Hands free
This prompt will guide you through piece counting without pressing a key.
1. Press the soft key Prompt.
In the soft key line the following instruction is displayed:
“Put on weight and wait for Auto tare.”
2. Put on the tare weight.
When the weight is stable, an automatic taring is carried out.
In the soft key line the next instruction is displayed:
“Load ... reference parts and wait for Auto ref n.”
3. Load the indicated number of reference parts.
The weight unit changes to PCS and the following soft key line is displayed:
4. Put on the weighing samples and read the number of pieces.
5. To leave piece counting press the soft key C.
“Cleared” is displayed briey.
.
METTLER TOL EDO User manual ICS46504/12Order number 22023406A
25
Operation
2.11.4 Multi tare
This prompt will guide you through taring a bundle of containers with the same known
tare weight.
1. Press the soft key Prompt.
The number of containers (n) is highlighted.
2. Enter the number of containers and conrm entry with the soft key OK.
The tare value of a single container is highlighted.
3. Enter the known tare weight of a single container and conrm entry with the soft key
OK.
When all entries are made, the weight display is shown.
E.g., with a bundle 6 containers of 0.4 kg each, a PT value of 2.4 kg is displayed for
the whole bundle.
4. Weigh the bundles.
The net weight of the bundle is displayed without extra taring.
5. To leave prompting press C.
“Cleared” is displayed briey.
2.11.5 Additive tare
This prompt will guide you through taring e.g., a pallet with containers on it with known
tare weights.
1. Press the soft key Prompt.
The following screen is displayed:
2. Enter the known tare weights and conrm each entry with the soft key OK.
– Use the soft key to proceed to the next tare weight. When there is no more tare
weight entered, the marking switches to the rst tare weight.
– Use the soft key to delete a tare weight.
3. When all tare weights are entered, press the soft key OK to nish the entry.
The total of all tare weights is displayed as pretare value indicated with PT.
4. Weigh the pallets or similar.
The net weight of the pallet is displayed without extra taring.
5. To leave prompting press C.
“Cleared” is displayed briey.
26
METTLER TOL EDO User manual ICS465
04/12Order number 22023406A
2.12 Callingupalibilogle
If requested by national regulations, the optional Alibi memory is available to trace all
weighing activities on the scale.
The alibi log le stores all weighings with the mandatory data. In addition you can store
one more item, either device name, device location or article number (Application –> Memory –> Custom eld).
1. Press the soft key Alibi.
The alibi records of the last 5 weighing operations are displayed.
The weighing data of the data record with the highlighted number are displayed.
2. Use the soft keys / to scroll the list. Soft key End leads you to the last weighing.
3. Press the soft key Esc to leave the Alibi memory.
2.13 Switching scales
Prerequisite
9 Two scales are connected to the weighing terminal.9 The soft key Switch scale is activated in the Terminal menu.
➜ Press the soft key to switch the active scale.
The current active scale is displayed in the symbol and info line on the top of the
display.
METTLER TOL EDO User manual ICS46504/12Order number 22023406A
27
Loading...
+ 63 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.