Conventions and Symbols Used in these Operating Instructions1.17
Definition of Signal Warnings and Symbols2.18
Product Specific Safety Notes2.28
Overview3.111
Drying Unit 3.1.111
Terminal3.1.212
Keys on the Terminal3.1.314
User Interface3.215
User "Home" Screen3.2.116
Basic Elements on Touch Screen3.2.217
Icon and Buttons3.2.317
Status Message Icons3.2.3.117
Title Bar Icons3.2.3.217
Action Bar Buttons3.2.3.317
Input Dialogs3.2.418
Entering Text and Numbers3.2.4.118
Entering Numerical Values3.2.4.219
Changing Date and Time3.2.4.320
Lists and Tables3.2.521
Work Screen3.2.622
Graphics View3.2.723
Scope of Delivery4.124
Location4.224
Opening and Closing Sample Chamber4.325
Connecting Instrument4.425
Setting up Drying Unit4.526
Leveling Drying Unit4.627
Anti-theft Device4.728
Setting Reading Angle of Terminal4.828
Setting Date, Time and Country4.928
Adjustment4.1029
Install METTLER TOLEDO RHT sensor 4.1129
Settings634
User Preferences6.135
Languages6.1.135
Screen 6.1.235
Sound6.1.336
Password6.1.436
Table of Contents3
Page 4
System Settings6.237
Regional Settings6.2.137
Peripherals6.2.237
Default Settings6.2.339
Default Languages6.2.3.139
Default Screen Settings6.2.3.240
Company Information6.2.440
Touch Screen Adjustment6.2.540
Network Interfaces6.2.641
Applications Settings6.344
Identifications Management6.3.144
Print and Export Management6.3.245
Quality Management6.448
Test / Adjustment settings6.4.148
Equipment6.4.1.148
Test Settings6.4.1.249
Adjustment Settings6.4.1.351
Print and Output Settings6.4.1.451
FACT (Fully automatic adjustment)6.4.1.552
User Management6.553
Groups6.5.153
Users6.5.255
Account Policies6.5.356
System and Data Management6.657
Result Management6.6.157
Export / Import6.6.257
Back up / Restore6.6.359
Export event logs6.6.459
Reset6.6.560
Update6.6.660
Tests7.267
Weight test - internal7.2.167
Weight test - external7.2.267
Temperature test7.2.368
SmartCal test7.2.469
Test Printout Examples7.2.571
History7.372
Method Definition873
Main Measuring Parameters8.175
Settings of Drying Program8.1.175
Settings of Standard drying8.1.1.175
Settings of Rapid drying8.1.1.276
Table of Contents4
Page 5
Settings of Gentle drying8.1.1.377
Settings of Step drying8.1.1.479
Settings of Switch-off Criterion (SOC)8.1.1.580
Settings of SOC Delay8.1.1.682
Settings of Display Mode8.1.282
Settings of Start Weight8.1.385
Result and Value Handling8.286
Control limits8.2.186
Resolution8.2.287
Free Factor8.2.388
Interfaces Specification13.3120
RS232C13.3.1120
USB Host13.3.2121
USB Device13.3.3121
How to Obtain Best Results15.1127
Measurement Principle of Halogen Moisture Analyzer15.1.1127
Notes on Adjustment of Balance and Heating Module15.1.2127
Optimum Sample Preparation15.1.3128
Further Information on Moisture Determination15.1.4128
Recommended Printer Settings (Strip printer)15.2128
Installing USB Device Driver15.3129
Third Party License/Notice15.4130
Table of Contents6
Page 7
1Introduction
1
2
…
Thank you for purchasing a Halogen Moisture Analyzer from METTLER TOLEDO.
Your Moisture Analyzer is fast and reliable. It offers a high level of operating convenience and useful functions
to facilitate determination of the moisture content of your samples.
Behind your instrument stands METTLER TOLEDO, a leading manufacturer of not only balances and scales for
the lab and production, but also analytical measuring instruments. A customer service network covering the
entire globe with well trained personnel is your service at all times, whether you are choosing accessories or
require guidance for a specific application to ensure optimum utilization of your instrument.
Your Halogen Moisture Analyzer is used for determining the moisture content of almost any substance. The
instrument works on the thermogravimetric principle. At the start of the measurement the Moisture Analyzer
determines the weight of the sample, the sample is then quickly heated by the integral halogen heating module
and the moisture vaporizes. During the drying process the instrument continually measures the weight of the
sample and displays the reduction in moisture. Once drying has been completed, the moisture or solids content
of your sample is displayed as the final result.
Of decisive importance in practice is the rate of heating and even heating of the surface of the sample. In com
parison with conventional infrared heating or the drying oven method, for example, the halogen heating module
of your instrument needs a shorter time to reach its maximum heating power. It also allows use of high temper
atures, an additional factor in shortening the drying time. Uniform heating of the sample material ensures good
repeatability of the drying results and makes it possible to use a smaller amount of sample.
The Moisture Analyzer conforms with all common standards and directives. It supports stipulations, work tech
niques and result records as demanded by all international quality assurance systems, e.g. GLP (Good Labora
tory Practice), GMP (Good Manufacturing Practice). The instrument has a CE declaration of conformity and
METTLER TOLEDO as the manufacturer has been awarded ISO 9001 and ISO 14001 certification. This provides
you with the assurance that your capital investment is protected in the long term by a high product quality and
a comprehensive service package (repairs, maintenance, servicing, adjustment service).
Finding More Information
Software version
These operating instructions are based on the initially installed firmware (software) version V2.10.
1.1Conventions and Symbols Used in these Operating Instructions
Key and button designations are indicated by a picture or text in square brackets (e.g. [Save]).
These symbols indicate an instruction:
prerequisites
steps
results
u www.mt.com/hxhs
7Introduction
Page 8
2Safety Information
2.1Definition of Signal Warnings and Symbols
Safety notes are marked with signal words and warning symbols. These show safety issues and warnings.
Ignoring the safety notes may lead to personal injury, damage to the instrument, malfunctions and false results.
Signal Words
WARNINGfor a hazardous situation with medium risk, possibly resulting in severe
injuries or death if not avoided.
CAUTIONfor a hazardous situation with low risk, resulting in damage to the device or
the property or in loss of data, or minor or medium injuries if not avoided.
Attention(no symbol)
for important information about the product.
Note(no symbol)
for useful information about the product.
Warning Symbols
General hazardElectrical shock
Hot surfaceInflammable or explosive
substance
Toxic substanceAcid / Corrosion
2.2Product Specific Safety Notes
General Safety Information
Your instrument meets the state of the art technology and complies with all recognized safety rules, however,
certain hazards may arise in extraneous circumstances. Do not open the housing of the instrument: It does not
contain any parts which can be maintained, repaired or replaced by the user. If you ever have problems with
your instrument, contact your authorized METTLER TOLEDO dealer or service representative.
Always operate and use your instrument only in accordance with the instructions contained in this manual. The
instructions for setting up your new instrument must be strictly observed.
If the instrument is not used according to these Operating Instructions, protection of the instrument may
be impaired and METTLER TOLEDO assumes no liability.
Intended Use
Your Moisture Analyzer is used for determining the moisture in samples. Use the instrument exclusively for this
purposes. Any other type of use and operation beyond the limits of technical specifications without written con
sent from Mettler-Toledo AG, is considered as not intended.
Moisture determination applications must be optimized and validated by the user according to local regula
tions. Application-specific data provided by METTLER TOLEDO is intended for guidance only.
8Introduction
It is not permitted to use the instrument in explosive atmosphere of gases, steam, fog, dust
and flammable dust (hazardous environments).
Page 9
Staff Safety
The Moisture Analyzer may be operated only by trained personnel who are familiar with the properties of the
samples used and with the handling of the instrument.
In order to use the instrument, you must have read and understood the operating instructions. Keep the operat
ing instructions for further reference.
Never make any modifications to the instrument and use only original spare parts and optional equipment from
METTLER TOLEDO.
Protective Clothing
It is advisable to wear protective clothing in the laboratory when working with the instrument.
A lab coat should be worn.
A suitable eye protection such as goggles should be worn.
Use appropriate gloves when handling chemicals or hazardous substances, checking their
integrity before use.
Safety Notes
WARNING
Risk of electric shock
Your instrument is supplied with a 3-pin power cable with an equipment grounding conduc
tor. Only extension cables which meet this relevant standards and also have an equipment
grounding conductor may be used. Intentional disconnection of the equipment grounding
conductor is prohibited.
CAUTION
The Halogen Moisture Analyzer works with heat!
a) Ensure sufficient free space around the instrument to avoid heat accumulation and over
heating (approx. 1 m free space above the heating module).
b) The vent over the sample must never be covered, plugged, taped over or tampered with
in any other way.
c) Do not place any combustible materials on, under or next to the instrument since the
area around the heating module may be hot.
d) Exercise caution when removing the sample. The sample itself, the sample chamber, the
draft shield and any sample vessels used may still be very hot.
e) During operation, you should never open the heating module itself as the ring-shaped
heating reflector or its protective glass can reach 400 °C! If you have to open the heating
module e.g. for maintenance, disconnect the instrument from the power supply and wait
until the heating module has cooled down completely.
f) No modifications must be made within the heating module. It is particularly dangerous to
bend any components or remove them or to make any other changes.
9Safety Information
Page 10
Certain samples require special care!
With certain types of samples, there is a possibility of danger to personnel or damage of property. Please note
that the user always has the responsibility and liability for damage caused by use of any types of samples!
CAUTION
Fire or Explosion
• Flammable or explosive substances.
• Substances containing solvents.
• Substances which evolve flammable or explosive gases or vapors when heated.
a) In cases of doubt, perform a careful risk analysis.
b) Work at a drying temperature that is low enough to prevent the formation of flames or an
explosion.
c) Wear protective goggles.
d) Work with small amounts of sample.
e) Never leave the instrument unattended!
WARNING
Substances which contain toxic or caustic components
Toxic gases produced during drying could cause irritations (eyes, Skin, breathing), illness or
death.
– Such substances may be dried only in a fume cupboard.
CAUTION
Corrosion
Substances which evolve corrosive vapors when heated (e.g. acids).
– Work with small amounts of samples as the vapor can condense on cooler housing
parts and cause corrosion.
10Safety Information
Page 11
3Design and Function
1234
5
6
7
8
9
10
11
12
2120191817
16
15
14
13
22 4
In order to work with your Moisture Analyzer, you need to familiarize yourself with the instrument layout, drying
unit, graphical user interface of the touch screen as well as the terminal.
3.1Overview
3.1.1Drying Unit
Description of the components and the external connectors on the back of the drying unit (Weighing unit with
heating module).
1 Sample chamber
2 Sample pan handler
3 Sample pan holder
4 Leveling screw
5 Level indicator / Level sen
sor
6 Draft shield element
7 Contacts for temperature
adjustment kit(optional)
8 Power contacts for halogen
lamp
9 Temperature sensor
10 Heating module (with ther
mal overload protection)
11 Handles for emergency
opening the sample cham
ber
12 Inspection window and
vent
13 Fan
14 Dust filter (optional)
15 Power line fuse
16 Power supply socket
17 Kensington slot for anti-
theft purposes
18 Connection for the RHT
sensor.
19 Fastening for terminal
stand.
20 System connection (termi
nal cable)
21 Aux 2 connection (n.a.)
22 Aux 1 connection (n.a.)
Connectivity
20System connection Interface for the communication between terminal and drying unit.
16Power supply socket Power supply inlet socket for the country-specific power cable.
The socket has a built in fuse compartment containing a replacement
fuse.
11Design and Function
Page 12
18RHT sensor connectionConnection for the RHT sensor from METTLER TOLEDO for detecting
EXCELLENCE Plus
Excellence Plus
2
2
3
1
4
10
2
5
64897
3.1.2Terminal
Description of the connections at the terminal (Input and output unit with interfaces).
the current room temperature and relative humidity for SmartCal™
application. Attention
Do not use this port for other purposes!
1 WVGA color display (touch
screen)
2 Foot
3 USB Host connection
4 Faceplate
5 USB Host connection
6 USB Device connection
7 RS232C connection
8 Ethernet RJ45 connection
9 System connection (termi
nal cable)
10 Memory Card slot for SD
Card
12Design and Function
Page 13
Connectivity
USB host
A4 / Letter Printer
A4 / Letter Printer
Strip Printer
Switch /
Router
FTP Server
Workstation
Workstation
LabX direct moisture
MT SICS
USB host
WLAN
RS-232
RS-232
Ethernet
Ethernet
USB device
USB memory stick
SD Memory Card
➂
➂
➅
➄
➁
➁
➀
➆
➃
1System connection Interface for the communication between terminal and drying unit.
2RS232C connectionRS232C interface for connecting the instrument to a peripheral device
(e.g. printer or a PC with a 9-pin male connector).
3USB Host connectionUSB interface for connecting a peripheral device to the instrument
(e.g. memory stick up to 32GB). Type A Socket.
4USB Device connectionUSB interface for connecting the instrument to a peripheral device with
an USB host connection (e.g. PC). Type-B socket.
5Ethernet TCP/IP connectionEthernet interface for connecting the instrument to a TCP/IP network.
The most simple network can be implemented by connecting the
instrument directly to the PC with a cross-over cable (RJ45 Socket).
DHCP and fix IP addresses are supported.
6WLAN connectionWireless LAN interface for connecting the instrument to a wireless
7SD Memory Card slotThe memory card slot fits Secure Digital Memory Cards. SD and
TCP/IP network. DHCP and fix IP addresses are supported.
Note
This function is not available in every country.
SDHC types as well as sizes up to 32GB are supported. You can use
it as an external storage device e.g. to store measured results.
Note
SDXC types are not supported.
13Design and Function
Page 14
3.1.3Keys on the Terminal
2
3
1
4
1ON/OFFTo switch on or off (standby operation) the instrument.
2HomeTo return from any menu level, or other window to the user
NameExplanation
Note
Do not disconnect the instrument from the power supply except
if you will not be using the instrument for an extended period.
home screen.
3Open/CloseTo open or close the sample chamber motorized.
Attention
Do not open the sample chamber manually. Only open manual
ly in emergency situations. In all other cases use always the [ ]
key. See Opening and Closing Sample Chamber (page25)
4Touch screen
14Design and Function
Page 15
3.2User Interface
The colored touch screen is a touch-sensitive WVGA monitor. The touch screen not only displays information, it
also allows you to enter commands by touching certain areas on its surface: You can choose the information
displayed on the screen, change terminal settings or perform certain operations on the instrument.
Only those elements which are available for the current dialog appear on the display.
Buttons on the Touch Screen
Buttons are software elements on the touch screen (Soft keys).
CAUTION
Do not touch the touch screen with pointed or sharp objects!
This may damage the touch screen.
15Design and Function
Page 16
3.2.1User "Home" Screen
2
2
3
1
The user Home screen is the main screen and appears after startup or login of the instrument. All screens of the
user interface can be accessed from the home screen. Returning to the Home screen is possible from all other
screens of the user interface by pressing the [ ] key or tapping the [Home] button.
NameExplanation
MeasurementStart measurement
1
ResultsShow results
Method DefinitionDefine, edit or delete a method
Test/AdjustAdjust or test the instrument
SettingsDefine general settings
2User shortcuts
3Instrument infoShows general info about the instrument like type, serial number, software ver
Prerequisite:
Method is defined and all necessary settings are made.
For further information see My First Measurement (page31) and Measurement
(page94).
Under this menu item, all measurement results can be displayed, printed or
exported.
For further information see Results (page99).
All actions using in a drying method, can be defined under this menu item.
Description of the menu item see Method Definition (page73).
Under this menu item, the integrated balance and the heating module can be
adjusted or tested.
Description of the menu item see Test/Adjust (page62).
All settings of the system can be defined, e.g, system settings, user management
or user preferences. These settings are usually made during installation of the
instrument.
Description of the menu item see Settings (page34)
User-specific shortcuts for frequently used methods. Shortcuts are saved in the
user profile.
How to create shortcuts see Using Shortcuts (page97).
sion.
16Design and Function
Page 17
3.2.2Basic Elements on Touch Screen
1
2
3
4
The graphical user interface consists of the following basic elements.
Screen Areas and their Elements
NameExplanation
1Status BarThe status bar contains the user name, status icons as well as date and time.
See Status Message Icons (page17).
2Title BarThe title bar contains elements for the user's orientation and information, as well
as for special functions. See Title Bar Icons (page17).
3Content AreaThe content area is the main working area of the menus and the applications,
content depends on application or performed action. The content area also
shows graphic illustrations such as the curve diagram of a data set (e.g. drying
curve).
4Action BarThe action bar contains action buttons for triggering the actions which are
required and available in the current dialog (e.g. Back, ->0/T<-, Print, Save,
Delete, OK). See Action Bar Buttons (page17).
3.2.3Icon and Buttons
3.2.3.1Status Message Icons
Status messages are displayed by means of small icons in the status bar. For the most important messages
see Status Messages (page113).
By tapping the symbols, the explanation of the symbols will appear in a separate window. By tapping the quick
access icon , brightness or sound can be set.
3.2.3.2Title Bar Icons
The title bar icons only appear when they are active. The icons which appear in the title bar, are listed with their
function below:
Explanation
Create a shortcut and add it to your user home screen. Edit or remove an existing shortcut
see Using Shortcuts (page97).
3.2.3.3Action Bar Buttons
The action bar contains action buttons for triggering any of the actions which are required and available in the
current dialog (e.g. Back, ->0/T<-, Print, Save, Delete, OK). There are up to six action buttons available for a
work step. The functions of these buttons are self explanatory and therefore not discussed further.
17Design and Function
Page 18
3.2.4Input Dialogs
1
2
3
2
3
1
3.2.4.1Entering Text and Numbers
The keyboard dialog allows you to enter characters including letters, numbers and a variety of special charac
ters. The country-specific layout of the keyboard is in accordance with the selected language, see Regional Set
tings (page37).
NameExplanation
1Input field
2Explanation fieldThe maximum number of characters allowed is indicated.
3ShiftYou can enter lower and upper case letters by toggling . Switch the keyboard
by tapping the corresponding button in the action bar, for entering numbers, spe
cial characters or letters
– Confirm with [OK] (To exit keyboard tap [Cancel]).
Function
Shift-Lock
Delete last character
Cursor left
Cursor right
Note
It is also possible to place cursor directly in input field by tapping the respective position.
18Design and Function
Page 19
3.2.4.2Entering Numerical Values
2
3
2
3
1
The numerical keypad dialog allows you to enter numerical values.
NameExplanation
1SwitchIf a switch appears, located on the left side in the title bar; it must be switched on
2Input field
3Explanation fieldThe valid input range is indicated.
– Confirm with [OK].
To exit keypad, tap [Cancel].
Delete last character
for the entry of a value: O = OFF, I = ON
Function
Cursor left
Cursor right
19Design and Function
Page 20
3.2.4.3Changing Date and Time
1
3
1
2
2
3
1
This dialog (Picker view) allows you to set the date and time by picking from the built-in calendar/clock.
– Confirm with [Set date]. (To exit without changing, tap [Cancel].)
20Design and Function
Page 21
3.2.5Lists and Tables
2
3
1
5
6
4
Simple list view
Basic elements of a simple list including a content title. If necessary, the content area can be scrolled vertically
and can be arranged in a different order.
NameExplanation
1Content title
2Content area
3Arrow icon[i] Showing the list in ascending order.
4Scrolling up
Scrollbar
5Scroller
6
[h] Showing the list in descending order.
Scrolling down
Further types of lists:
Accordion panels can be opened or closed by tapping
[ ].
Closable panels can be opened or closed by tapping
[>].
21Design and Function
Page 22
3.2.6Work Screen
2
7
2
1
3
5
6
4
7
The work screen is used for performing main tasks e.g. measurements.
NameExplanation
1Name fieldName of current Method
2Shortcut buttonAdding/editing a shortcut to the home screen for this method
3Value panelDisplays the current measured values of the work process
4Graphics panelE.g. graphical illustrations of the drying curves, instructions for the user for per
5ID panelIdentifications (IDs) appear after tapping the ID panel for entering or editing val
6Parameter panelDisplays the parameters of the current work process. A detailed overview of the
7Action buttonsDepending on the current context
forming tasks, and weighing-in aid
ues (comments). ID panel appears only if identification input is activated in the
menu.
method parameters appears after tapping the parameter panel.
22Design and Function
Measurement in progress
Page 23
3.2.7Graphics View
Graphical view of single measurementChart view of series of measurements
For further information see Graphical Evaluations of Measurement Results (page99)
23Design and Function
Page 24
4Installation and Putting into Operation
In this section you will find information how to put your new instrument into operation.
4.1Scope of Delivery
Open the package and remove drying unit, terminal and the accessories. Check the completeness of the deliv
ery. The following accessories are part of the standard equipment of your new Moisture Analyzer:
1 Application brochure «Guide to Moisture Analysis»
●
1 Production certificate
●
1 Declaration of conformity
Remove the packaging from the instrument. Check the instrument for transport damage. Immediately inform
your METTLER TOLEDO representative if you have any complaints or parts are missing.
Note
Store all parts of the packaging. This packaging guarantees the best possible protection for the transport of your
instrument.
4.2Location
Your Moisture Analyzer is a precision instrument. An optimum location guarantees accuracy and dependability.
Make sure that the following environmental conditions are met:
●
Operate the instrument only indoors and at an altitude of less than 4000 m above sea level.
●
Before switching on the instrument, allow all its parts to reach room temperature (+5 to 30°C).
Make sure that the relative humidity is between 20% and 80% and non-condensing conditions are met.
●
The power plug must be easily accessible.
●
Firm, horizontal location as free from vibrations as possible.
●
Avoid direct sunlight.
●
No excessive temperature fluctuations.
●
No powerful drafts.
●
Surroundings as free from dust as possible.
●
Sufficient clearance around the instrument to allow warm air to dis
sipate.
●
Sufficient distance from heat-sensitive materials in the vicinity of the
instrument.
24Design and Function
Page 25
WARNING
Substances which contain toxic or caustic components
Toxic gases produced during drying could cause irritations (eyes, Skin, breathing), illness or
death.
– Such substances may be dried only in a fume cupboard.
4.3Opening and Closing Sample Chamber
Open and close the sample chamber exclusively by pressing the [ ] key.
Attention
Do not open the sample chamber manually.
Only manually opening the sample chamber in emergency situation:
1 Hold the handles on the heating module with both hands and pull the module firmly upwards to open the
sample chamber.
2 Pull out the power plug.
Note
It is necessary to reboot the system, after an emergency opening.
4.4Connecting Instrument
WARNING
Risk of electric shock
a) Use only the 3-pin power cable with equipment grounding conductor which was supplied
with your instrument.
b) Only a 3-pin grounded outlet for connecting your instrument must be used.
c) Only extension cables which meet this relevant standards and also have an equipment
grounding conductor may be used.
d) Intentional disconnection of the equipment grounding conductor is prohibited.
Attention
●
First, check whether the voltage printed on the type plate of the drying unit matches your local line voltage. If
this is not the case, on no account connect the drying unit to the power, but contact your METTLER TOLEDO
sales representative or dealer.
Two different versions of drying units with country-specific power cable are available (110VAC or
230VAC).
●
The power plug must be always accessible.
●
Before operating, check all cables for damage.
●
Guide the cables so that they cannot become damaged or interfere with the measuring process.
Connecting the Terminal to the Drying Unit
Drying unit and terminal are at the final location.
1 Connect one end of the supplied terminal cable to the system connection socket on the terminal, see Termi
nal (page12).
2 Screw the connector firmly.
3 Connect the other end to the system connection socket on the drying unit, see Drying Unit (page11).
4 Screw the connector firmly.
25Installation and Putting into Operation
Page 26
Connecting the Drying Unit to the Power Supply
312
Terminal – drying unit interface is connected.
1 Connect one end of the power cable to the power supply socket on the drying unit, see Drying Unit
(page11).
2 Connect the other end to the power line outlet.
4.5Setting up Drying Unit
Terminal and drying unit are connected.
1 Switch on the Instrument by pressing [ ].
2 Press [ ].
the motorized automatic sample chamber opens.
3 Place the draft shield element (1). Only one position is possible.
4 Insert the sample pan holder (2) carefully. Check that the sample pan holder is hooked correctly.
5 Insert the sample pan handler (3).
Attention
The drying unit is specially designed for motorized opening or closing of the sample chamber.
Do not open the sample chamber manually. Only open manually in emergency situations. In all other cases
use always the [ ] key, see Keys on the Terminal (page14).
Note
When putting into operation for the first time or if the instrument is disconnected from the power over a longer
period, leave the instrument connected to the power supply for at least 5 hours to allow the built-in recharge
able battery to charge up! This battery ensures that the date and time are not lost when the instrument is dis
connected from the power. This battery can not be replaced by the user. Please contact a METTLER TOLEDO
representative.
26Installation and Putting into Operation
Page 27
4.6Leveling Drying Unit
L
R
Exact horizontal positioning and stable installation are prerequisites for repeatable and accurate results. To
compensate for small irregularities or inclinations (±2%) at the location, the instrument must be leveled.
For exact horizontal positioning, the drying unit has a level indicator
(level) and 2 leveling screws. When the air bubble in the level indica
tor is exactly in the center, the instrument is standing perfectly horizon
tally. To level it, proceed as follows:
1 Position your Moisture Analyzer at the selected location.
2 Turn the two leveling feet until the air bubble is in the center of the
level indicator.
L = left foot
R = right foot
Air bubble at"12 o'clock"turn both feet clockwise
Air bubble at"3 o'clock"turn left foot clockwise,
Air bubble at"6 o'clock"turn both feet counter
Air bubble at"9 o'clock"turn left foot counterclock
Note
The drying unit should be re-leveled each time its location is changed.
right foot counterclock
wise
clockwise
wise, right foot clockwise
Leveling the drying unit with optional stand for terminal mounted.
Stand for terminal see Accessories and Spare Parts (page122).
The drying unit is positioned at the selected loca
tion.
1 To loose the clamps for the safety feet of the
stand, turn them outwards.
2 Level the drying unit as previously described.
3 To lock the clamps for the safety feet, turn them
inwards as far as they will go.
27Installation and Putting into Operation
Page 28
Level sensor
The built-in level sensor constantly monitors the correct horizontal alignment of the drying unit. When the level
is incorrect, the status icon appears in the display, see Status Message Icons (page17).
Note
The level sensor cannot be switched off.
4.7Anti-theft Device
For protection against theft, your drying unit is fitted
with a Kensington security slot for an anti-theft device.
To find a suitable anti-theft cable see Accessories and
Spare Parts (page122).
4.8Setting Reading Angle of Terminal
– To change the reading angle, fold out the two tilt feet.
4.9Setting Date, Time and Country
Navigation: Home > Settings > System settings > Regional Settings
When you put your new instrument into operation for the first time, you should enter the current date and time
as well as the country in which the instrument is operated. These settings are retained even if you disconnect
your instrument from the power supply.
Note
Various languages are available for the dialog with your instrument and can be selected in the menu:
Navigation: Settings > User preferences, see User Preferences (page35).
Set the current date
Regional Settings is selected.
1 Tap Date.
2 Set day, month and year.
3 Confirm with [Set date].
Set the current time
Regional Settings is selected.
1 Tap Time.
2 Set Hours and minutes.
3 Confirm with [Set time].
28Installation and Putting into Operation
Page 29
Set the country in which the instrument is operated.
Regional Settings is selected.
1 Tap Country.
2 Set the country (region).
3 Confirm with [Save].
Note
For changing the format for date and time, see Regional Settings (page37).
4.10Adjustment
To obtain accurate measuring results, it is necessary to adjust the integrated balance as well as the heating
module.
Adjusting is necessary:
●
before the instrument is used for the first time.
●
at regular intervals.
●
after a change of location.
The following adjustment options are possible:
●
Fully automatic balance adjustment FACT.
●
Balance adjustment with internal weight.
●
Balance adjustment with external weight (accessory).
●
Temperature adjustment with temperature adjustment kit (accessory).
For more information to perform these operations see Test/Adjust (page62).
4.11Install METTLER TOLEDO RHT sensor
The RHT sensor from METTLER TOLEDO allows the automatic detection of relative humidity and temperature
values for SmartCal tests, see SmartCal test (page69).
Note
Not delivered with every model.
Installation on the Drying Unit
1 Loosen the two screws.
2 Remove screws and cover.
3 Retain these for later use.
29Installation and Putting into Operation
Page 30
1 Take the sensor out of its packing.
A
2 Retain the packing for later use.
3 Connect the RHT sensor to the drying unit with
sensor opening (A) facing down.
– Tighten the two screws to secure the RHT sensor.
Attention
Please observe the following instructions to avoid wrong SmartCal measurements.
●
Do not install the RHT sensor on the terminal.
●
Be sure that the sensor opening is clean.
●
Do not touch the sensor opening with sharply pointed objects.
●
After installing, RHT sensor must be acclimatized in working area for about one hour, before using.
●
Exposure to acids, bases or volatile compounds (e.g. solvents) at high concentration or long exposure time
must be avoided.
●
The RHT sensor must be stored in the original, sealed anti-static bag.
●
For storage temperature shall be in the range of 10°C…50°C and humidity at 20…60%rH.
●
We recommend to remove the RHT sensor from the drying unit after a SmartCal measurement and to
store it in the original, sealed anti-static and bag.
●
Settings see Equipment (page48).
30Installation and Putting into Operation
Page 31
5My First Measurement
After you have successfully put your new Moisture Analyzer into operation for the first time, you can immediate
ly perform your first measurement. In doing so, you will become familiar with the instrument.
Use the supplied specimen sample (absorbent glass fiber filter) for your first measurement to determine the
moisture content. During your first measurement the instrument operates with the factory settings.
Switching on
The instrument is connected to the mains.
– To switch on, press [ ].
Create a method
1 Tap Method Definition.
Method Definition menu appears.
2 To define a new method, tap [New...].
The keypad appears.
3 Enter a name for your first method e.g. My first method.
4 Confirm with [OK].
5 To store your new method with factory settings, tap [Save].
6 Tap [Home].
User home screen appears.
Select the method for measuring
1 Tap [Measurement].
The methods list is displayed.
2 Tap My first method.
The work screen of the method My first method appears.
The sample chamber opens automatically.
Placing sample pan
The display now prompts you to load the empty sample pan and
tare the balance.
1 Place the empty sample pan in the sample pan handler.
2 Place the sample pan handler in the sample chamber. Ensure that
the tongue of the pan handler fits exactly in the slot of the draft
shield element. The sample pan must lie flat in the pan holder.
Note
We advise you to work with the sample pan handler at all times. The
pan handler is ergonomic, automatic positioning, safe and provides
protection against possible burns due to the hot sample pan.
31My First Measurement
Page 32
Taring balance
#
– Tap [->0/T<-].
The sample chamber closes automatically for taring.
When taring is completed, the sample chamber opens auto
matically.
Start measuring
Following taring, the display prompts you to add the sample to the
sample pan.
1 Place the specimen sample (glass fibre filter) in the sample pan.
2 Wet the specimen sample with a few drops of water.
3 Tap [Start drying]
The sample camber closes automatically.
The drying process starts automatically.
Drying process
You can follow the measurement process on the display, see Work Screen (page22).
●
The drying process is continuously displayed graphically.
●
The current temperature in the heating module is displayed as well as the elapsed drying time and the cur
rent drying value.
●
The display shows the selected settings.
●
The drying process can be aborted by tapping [Stop drying].
At the end of the drying process you can read the moisture content of your sample on the display. If you have
defined the control limits in the method, passed, warned or failed status is shown.
Remove Sample
CAUTION
Danger of burns
Sample, sample pan and sample pan holder may still be hot.
32My First Measurement
Page 33
The drying process is completed.
The sample chamber is open (opens automatically after the mea
surement is completed).
1 Carefully remove the sample pan handler from the sample cham
ber.
Note
To remove the sample pan from the handler, lift the pan slightly
from below and remove it from the handler.
2 • To perform a further measurement with the current method, tap
[Next Sample].
• To perform a measurement with a new method, tap [Measurement].
• To return to the home screen, press [ ].
Congratulations!
You have just performed your first measurement with your new Moisture Analyzer. In the following sections
you will find more information about the extensive functions of this instrument.
33My First Measurement
Page 34
6Settings
Navigation: Home > Settings
In this section you will find information how to define the general settings of your instrument.
Menu structure
Main menuSubmenuFurther information
User preferences
System settings
Application settings
Quality managementTest / Adjustment settingssee Test / Adjustment settings
Result managementsee Result Management (page57)
Export / Importsee Export / Import (page57)
Back up / Restoresee Back up / Restore (page59)
Export event logssee Export event logs (page59)
Resetsee Reset (page60)
Updatesee Update (page60)
34My First Measurement
Page 35
6.1User Preferences
Navigation: Home > Settings > User preferences
This menu item defines the basic settings for each user. This settings are stored under the active user profile
and apply when working within this profile. When a user profile is called up (login user account), the relevant
settings are loaded automatically. See User Management (page53).
You can define the following parameters:
Menu itemExplanationFurther Information
LanguagesDefines your preferred display and keyboard lan
ScreenDefines the brightness and the color scheme of the
SoundDefines audible feedbacksee Sound (page36)
PasswordDefines user passwordsee Password (page36)
6.1.1Languages
Navigation: Home > Settings > User preferences > Languages
Select your preferred language for operating the terminal.
Factory setting: Generally, the language of the destination country (if available) or English is set.
Defines user-specific layout of the Keypad.English| Deutsch|
Italiano| Français|
Español| Português|
Polski| Magyar|
Český
6.1.2Screen
Navigation: Home > Settings > User preferences > Screen
You can define the following parameters:
ParameterExplanationValues
BrightnessDefines user-specific brightness of the display.10…100%
Color schemeDefines user-specific display color scheme.Blue*| Green|
* Factory setting
(80%)*
Orange| Grey
35Settings
Page 36
6.1.3Sound
Navigation: Home > Settings > User preferences > Sound
You can define the following parameters:
ParameterExplanationValues
SoundActivate / deactivate of audible feedback and adjust the Volume.
* Factory setting
6.1.4Password
Navigation: Home > Settings > User preferences > Password
In this menu item you can change the user password. It is also possible to create a password for protection or
to deactivate the password protection.
You can define the following parameters:
ParameterExplanationValues
PasswordChange an existing (Old password) and create a New
Audible feedback:
●
when tapping a button.
●
upon measurement completed.
●
before automatic closing of the sample chamber.
●
when an error message appears.
password.
ON = for entry of a new login password.
OFF = no password protection.
OFF*| ON
0...100 %
(50 %)*
ON | OFF | any
36Settings
Page 37
6.2System Settings
Navigation: Home > Settings > System settings
This menu item defines the basic settings for the system. The system settings apply to the entire system and
therefore to all user profiles and applications.
You can define the following parameters:
Menu itemExplanationFurther Information
Regional set
tings
PeripheralsDefines the configuration of printers and other
Network inter
faces
Default settingsDefines the default settings of your instrument.see Default Settings (page39)
Company infor
mation
Touch screen
adjustment
6.2.1Regional Settings
Navigation: Home > Settings > System settings > Regional Settings
This menu item defines the settings of date & time.
You can define the following parameters:
ParameterExplanationValues
DateSets the date of the clock of the instrument.Day| Month| Year
TimeSets the clock time of the instrument.Hours| Minutes
Date formatDefines the date format.
Time formatDefines the time format.
CountryDefines the country in which the instrument is operated.Europe| China|
* Factory setting
Defines the settings of date & time, keypad and
country options.
devices.
Defines network connections. see Network Interfaces (page41)
Defines company specific information.see Company Information (page40)
Adjusts the touch screen.see Touch Screen Adjustment
Date and time of a connected printer will be ignored. Date and time of instrument is relevant.
6.2.2Peripherals
Navigation: Home > Settings > System settings > Peripherals
In this menu item you can configure one printer and one host connection.
PCs
The MT-SICS host connection (remote client) is enabled by default and only usable with the METTLER TOLEDO
specific protocol MT-SICS.
37Settings
Page 38
MT-SICS commands and functions can be transmitted via the RS232 interface (COM1 port) or the USB device
interface (COM4 port). The use of the USB device interface requires the installation of an USB device driver on
the PC, see Installing USB Device Driver (page129).
Commands and further information please refer to the Reference Manual MT-SICS Interface Commands forHalogen Moisture Analyzers downloadable from the internet.
u www.mt.com/hxhs
Printers / PCs
No printer is installed by default. To install a printer:
The desired printer is properly connected to the terminal.
Note
Do not attempt to connect a printer to the drying unit!
1 Tap [New...]
Peripheral type list appears.
2 Select device.
Note
Currently supported devices from METTLER TOLEDO with preset parameters:
• RS-P42 Strip Printer, see RS232 parameters
• RS-P25 Strip Printer, see RS232 parameters
• Local PCL printer, see USB parameters
• Network PCL printer, see network parameters
• LabX Direct Moisture, see RS232 parameters
3 Set the parameters.
4 To store the settings, tap [Save].
5 To activate the interface, tap [ON].
Status changes from Disabled to Enabled.
Note
●
A printer or host connection can also be deleted.
●
For strip printer settings see Recommended Printer Settings (Strip printer) (page128).
●
For defining the printouts see Print and Export Management (page45).
●
Only one printer can be installed. To install another printer, you have to delete the old printer first.
38Settings
RS232 parameters
You can define the following parameters:
ParameterExplanationValues
Device NameDefines a name for the device.any
Device PortDefines the device port.
COM1*| COM 4
COM1: RS232 / COM4: USB Device (Driver required)
Note
It is possible to use an USB-to-Serial adapter. If such an adapter
is connected, these devices are shown as e.g.SOU1, SOU2 (SOU
stands for serial over USB)
BaudrateDefines the speed of the data transmission (data transfer rate /
Baud rate).
1200 | 2400 | 4800 |
9600* | 19200 |
38400 | 57600 |
115200
DataBitsDefines the number of data bits.7 | 8*
ParityDefines the variant of parity bit. None* | Odd | Even
StopBitsDefines the stop bits of the transmitted data.1 StopBit* |
2 StopBits
Page 39
Flow ControlDefines the type of flow control (Handshake).None | Xon/Xoff*
* Factory setting
USB parameters
●
Supported A4 Printer: OKI B411 USB
●
Supported printer command language: PCL 3 or higher
You can define the following parameters:
ParameterExplanationValues
Device NameDefines a name for the device.any
Network parameters
You can define the following parameters:
ParameterExplanationValues
Device NameDefines a name for the device.any
IP addressDefines the IP address of the printer.
PortDefines the printer's port.
* Factory setting
6.2.3Default Settings
Default address* | any
Default address*: 192.168.000.004
9100 * | any
Note
Usually the default value is used.
Navigation: Home > Settings > System settings > Default settings
Define the default settings of your instrument.
You can define the following parameters:
Menu itemExplanationFurther Information
Default lan
guages
Default screen
settings
6.2.3.1Default Languages
Navigation: Home > Settings > System settings > Default settings > Default languages
Select the default language for operating the terminal. Factory setting: Generally, the language of the destination
country (if available) or English is set.
You can define the following parameters:
ParameterExplanationValues
Default display
language
Default key
board language
Defines a default display and keyboard language.see Default Languages (page39)
Defines the default brightness and color scheme.see Default Screen Settings
Defines default layout of the keyboard.English| Deutsch|
Italiano| Français|
Español| Português|
Polski| Magyar|
Český
39Settings
Page 40
6.2.3.2Default Screen Settings
Navigation: Home > Settings > System settings > Default settings > Default screen settings
You can define the following parameters:
ParameterExplanationValues
BrightnessDefines default brightness of the display.10…100%
Color schemeDefines default display color scheme.Blue*| Green|
* Factory setting
6.2.4Company Information
Navigation: Home > Settings > System settings > Company information
In this menu item you can define optional specific company informations for using on printouts and reports.
You can define the following parameters:
ParameterExplanationValues
Company nameEntry of the company name.any
DepartmentEntry of the company department.any
Instrument IDEntry of the company specific instrument identificationany
Instrument loca
tion
Instrument
responsible
Entry of the location of the instrument.any
Entry of the name of the responsible person for the instrument.any
(80%)*
Orange| Grey
6.2.5Touch Screen Adjustment
Navigation: Home > Settings > System settings > Touch screen adjustment
If the alignment of the touch-sensitive areas of the screen correspond not exactly with the position of the buttons
e.g. after a software update was performed, then you can solve this error by executing this function.
CAUTION
Do not touch the touch screen with pointed or sharp objects!
This may damage the touch screen.
Menu System settings appears.
1 Choose Touch screen adjustment and tap [Start].
Adjustment screen appears.
2 Touch and hold a touch screen stylus (resistive) on the center of
the target until it moves to the next position on the screen.
3 Repeat this procedure until a message appears (New calibration
settings have been measured).
4 Tap the screen to confirm or wait for 30 seconds for canceling
(timeout).
A message box appears.
5 To store the setting, tap [OK].
40Settings
Page 41
Note
●
Tap the center of the target as accurately as possible otherwise the process has to be repeated several
times.
●
Make sure not to touch any other locations on the screen and the fix key areas while doing this adjustment.
●
Make sure not to touch the screen with your hand.
●
Keep accurate angle for your usage.
●
The adjustment process cannot be aborted.
6.2.6Network Interfaces
Navigation: Home > Settings > System settings > Network interfaces
In this section you will find information how to define network connections and other terminal interfaces.
Menu structure
Main menuSubmenuFurther information
Host nameDefines the host name of the instrumentsee Ethernet (page41)
EthernetActivates and sets Ethernet connection.see Ethernet (page41)
WLANActivates and sets wireless local area network
(WLAN) connection.
Host Name
Navigation: Home > Settings > System settings > Network interfaces > Host name
The Host name is the name of your instrument and is a unique identifier on a network (Ethernet, WLAN). If
using multiple devices, you should ensure that the host name of each instrument is unique. If necessary, con
tact the network administrator of your IT department or your IT support.
You can define the following parameters:
ParameterExplanationValues
Host nameDefines the host name. The host name must be unique on a net
work.
Default host name*: Model name and serial number of the instru
ment.
see WLAN (page42)
any
* Factory setting
Ethernet
Navigation: Home > Settings > System settings > Network interfaces > Ethernet
Ethernet interface for connecting the instrument to a TCP/IP network. The most simple network can be imple
mented by connecting the instrument directly to the PC with a cross-over cable (RJ45 Socket). DHCP and fix IP
addresses are supported.
Note
●
We recommend to use the default setting DHCP (automatic network settings).
●
Ensure that the host name of the instrument is unique, see Host Name (page41).
●
For installing and configuring an Ethernet interface you need to have basic knowlege of TCP/IP-based net
works and of network technology in general. If necessary, contact the network administrator of your IT
department or your IT support.
You can define the following parameters:
ParameterExplanationValues
ConfigurationDefines whether the settings are made automatically (dynamic,
DHCP) or manually (static).
DHCP assignment |
Manual assignment
41Settings
Page 42
DHCP assign
ment
Dynamic Host Configuration Protocol to assign all necessary net
work parameters on this interface automatically (Dynamic
none
assignment).
Manual assign
ment
IP addressDefines the IP address of this instrument. Only setable when
Manually assign all the necessary network parameters on this
interface. (Static assignment)
IP address | Subnet
Default address* | any
DHCP is disabled.
Default address*: 192.168.002.100
The IP address unique numeric identifier for a device which par
ticipates on a network.
If DHCP is enabled, the automatically assigned IP address is dis
played.
SubnetDefines the subnet mask within the ethernet interface is address
Default value* | any
able. Only setable when DHCP is disabled.
Default subnet mask*: 255.255.255.000
* Factory setting
Note
The addresses are written as four dot-separated decimal integers in the range from 0 to 255. Leading zeros
need not be written.
WLAN
Navigation: Home > Settings > System settings > Network interfaces > WLAN
Wireless LAN interface for connecting the instrument to a wireless TCP/IP network. DHCP and fix IP addresses
are supported.
Note
WLAN is not available in every country.
The following WLAN authentications are supported:
●
Open
●
WEP
●
WPA-PSK
●
WPA2-PSK (tkip only)
You can define the following parameters:
ParameterExplanationValues
WLANActivates or deactivates WLAN radio transmitter.OFF*| ON
* Factory setting
Note
After activating WLAN, it takes some time until WLAN is active.
WLAN Network Settings
Navigation: Home > Settings > System settings > Network interfaces > WLAN > Settings > WLAN configu
rations
●
We recommend to use the default setting DHCP (automatic network settings).
●
Ensure that the host name of the instrument is unique, see Host Name (page41).
●
For installing and configuring an Ethernet interface you need to have basic knowlege of TCP/IP-based net
works and of network technology in general. If necessary, contact the network administrator of your IT
department or your IT support.
42Settings
Page 43
You can define the following parameters:
ParameterExplanationValues
ConfigurationDefines whether the settings are made automatically (dynamic,
DHCP) or manually (static).
DHCP assign
ment
Manual assign
ment
IP addressDefines the IP address of this instrument. Only setable when
SubnetDefines the subnet mask within the ethernet interface is address
* Factory setting
Note
The addresses are written as four dot-separated decimal integers in the range from 0 to 255. Leading zeros
need not be written.
Dynamic Host Configuration Protocol to assign all necessary net
work parameters on this interface automatically (Dynamic
assignment).
Manually assign all the necessary network parameters on this
interface. (Static assignment)
DHCP is disabled.
Default address*: 192.168.002.100
The IP address unique numeric identifier for a device which par
ticipates on a network.
If DHCP is enabled, the automatically assigned IP address is dis
played.
able. Only setable when DHCP is disabled.
Default subnet mask*: 255.255.255.000
DHCP assignment |
Manual assignment
none
IP address | Subnet
Default address* | any
Default value* | any
Networks
Receivable networks are displayed.
Entries for WLAN:
ParameterExplanationValues
WLAN name
(SSID)
PasswordEntry for the required password.any
AutoconnectActivate or deactivate automatic connecting to the preferred net
Establish a connection:
1 Touch the desired network.
Note
If the device is connected to a network, the WiFi icon indicates the signal strength. The more bars displayed,
the stronger the connection.
2 Enter your password.
3 Enable automatic connection if needed.
4 Touch [connect] to establish the connection.
Displays the name of the selected WLAN (SSID, service set identi
fier)
work upon startup of the device.
Note
Only for one network possible.
not editable
(deactivated)*|
(activated)
43Settings
Page 44
6.3Applications Settings
Navigation: Home > Settings > Application settings
You can define the following parameters:
Menu itemExplanationFurther Information
Identifications
management
Print and export
management
6.3.1Identifications Management
Navigation: Home > Settings > Application settings > Identifications management
Identifications (ID) contain descriptive text for individual measurements, which enables samples to be easily
allocated to specific tasks or customers. This feature allows you to define identifications in order to comment
measurements, such as company id, id badge, id sample. In the ID panel on the work screen, the values
(comments) can be entered or changed before measurement, see Work Screen (page22). IDs have an impact
on all measurements, regardless of methods. The IDs are included on printouts or can be exported to a PC.
Menu structure
Main menuSubmenuFurther information
Identificationsno submenu
You can define the following parameters:
ParameterExplanationValues
Identifications
input
Clear input after
measurement
IdentificationsDefines general identifications in order to comment measure
Defines identifications and their use in order to
comment measurements.
Defines the default settings for the printouts.see Print and Export Management
Defines the method for entering comments.
ON = activates ID panel on work screen.
Free input = the IDs appear after tapping on the ID panel (work
screen) for entries or changes of values (comments).
Guided input = each ID is displayed individually in order of defi
nition (ID1 to ID10) before measurement, to make entries or
changes of values (comments).
Defines the ID whose value (comment) is deleted after measure
ment.
ments.
+ = New identifications (max. 10 IDs, 1…20characters)
- = Remove identifications (selectable)
Identifications inputIdentifications usage
Clear input after measurement
see Identifications Management
(page44).
(page45).
see below
OFF*| ON|
Free input|
Guided input
OFF*| ON |
ID selection:
| |
-| +*| any
44Settings
* Factory setting
Page 45
6.3.2Print and Export Management
Navigation: Home > Settings > Application settings > Print and export management
You can define the following parameters:
Menu itemExplanationFurther Information
Print manage
ment (Strip)
Print manage
ment (A4)
Print management
Print management (Strip)
Navigation: Home > Settings > Application settings > Print and export management > Print management
(Strip)
If a strip printer is connected and activated, results can be automatically printed out. The interim values are
printed out in the pre-selected intervals and the final results are logged at the completion of the measurement.
The printout contains information to the instrument, time, date as well as the method and results, depending of
the protocol. The level of detail depends on the selected type of printout (short, standard) and the activated pro
tocol items (settings or method), see Information on Printouts (page101).
Note
●
The definitions in this menu item are the default settings for the printouts. These parameters are displayed at
every initialization of a Printout and can be modified again.
●
The setting for printout language in this menu item has no impact on test or adjustment printouts, see Print
and Output Settings (page51).
●
Not all languages are compatible with some printers, and also depending on the settings of the printer, see
Recommended Printer Settings (Strip printer) (page128).
●
For installing and defining a printer see Peripherals (page37).
Defines the settings for printouts on strip printers.see Print management (page45).
Defines the settings for ISO A4 printouts on PCL
printers.
see Print management (page45).
You can define the following parameters:
ParameterExplanationValues
Printout typeSelects a detailed printout or in a short form. Standard*| Short
Printout lan
guage
Defines the language for general printouts.
Note
No impact on test or adjustment printouts.
English| Deutsch|
Italiano| Français|
Español| Português|
Polski| Magyar|
Český
Print results
automatically
Print results automatically after measurement if activated. (deactivated)*|
(activated)
after measure
ment
Include interme
diate results to
Defines the time intervals at which interim results are transferred
to the printer.
OFF*| 10s| 30s|
1min| 2min| 10min
printout
* Factory setting
Print management A4
Navigation: Home > Settings > Application settings > Print and export management > Print management
(A4)
If a PCL printer is connected and activated, results can be manually or automatically printed out on ISO A4
paper size. The level of detail depends on the selected export file, see Information on Exports (page105).
45Settings
Page 46
Note
●
The definitions in this menu item are the default settings for the printouts. These parameters are displayed at
every initialization of a Printout and can be modified again.
●
The setting for printout language in this menu item has no impact on test or adjustment printouts, see Print
and Output Settings (page51).
●
For installing and defining an A4 printer, see Peripherals (page37).
You can define the following parameters:
ParameterExplanationValues
Printout lan
guage
Defines the language for general printouts.
Note
No impact on test or adjustment printouts.
English| Deutsch|
Italiano| Français|
Español| Português|
Polski| Magyar|
Český| Pусский|
日本語| 中文|
한국어/조선말
Print results
automatically
Print results automatically after measurement if activated. (deactivated)*|
(activated)
after measure
ment
Export management
Navigation: Home > Settings > Application settings > Print and export management > Export management
If a PC or WLAN is connected and activated, final results can be automatically exported. The export contains
information to the instrument, time, date, method, result as well as the graphical curve.
You can define the following parameters:
ParameterExplanationValues
File name prefix Defines the name of the new data file. Date and time are auto
matically added by the system.
File typeDefines the type of the data file.CSV* | PDF
Printout lan
guage
Defines the language for general printouts.
Note
No impact on test or adjustment printouts.
Export manage
Export results automatically after measurement if activated.Selection:
ment
Export targetDefines the destination of data transfer. Peripheral |
* Factory setting
any
English| Deutsch|
Italiano| Français|
Español| Português|
Polski| Magyar|
Český| Pусский|
日本語| 中文|
한국어/조선말
*|
Network (FTP)
46Settings
Export target: Peripheral
ParameterExplanationValues
LocationFinds the location on the storage device.Browse and select
* Factory setting
Export target: Network (FTP)
For data transfer over a network (Ethernet and WLAN) the File Transfer Protocol FTP is used. The receiving serv
er is defined by entry of the appropriate IP address. If necessary, contact the network administrator of your IT
department or your IT support.
Page 47
ParameterExplanationValues
IP addressDefines the IP address of the receiving server.any
PortDefines the Port for communication with the server.
Note
Usually the default value is used.
PasswordEntry for the password needed for server login.any
User nameEntry for the user name needed for server login.any
* Factory setting
21* | any
47Settings
Page 48
6.4Quality Management
Navigation: Home > Settings > Quality management
In this menu you can define all settings related to the adjustment and Test of the instrument. Periodic adjust
ments or tests ensure accurate measurement results.
You can define the following parameters:
Menu itemExplanationFurther Information
Test / Adjust
ment settings
6.4.1Test / Adjustment settings
Navigation: Home > Settings > Quality management > Test / Adjustment settings
This section describes all the menu options available for defining the parameters relating to the adjustment and
testing of your instrument.
For performing test and adjustments see Test/Adjust (page62).
Menu structure
Main menuSubmenuFurther information
Equipment
Test settings
Adjustment settings
FACTno submenusee FACT (Fully automatic adjust
Defines the equipment for adjusting and the work
flow for testing or adjusting.
see Test / Adjustment settings
(page48)
Test weight 1
Test weight 2
Temperature kit
External humidity sensor
Weight test - internal
Weight test - external
Temperature test
SmartCal test
Weight adjustment - internalNo adjustable settings available
Weight adjustment - external
Temperature adjustment
Printout languagePrint and output settings
Print results automatically after
test/adjustment
see Equipment (page48)
see Test Settings (page49)
see Adjustment Settings (page51)
see Print and Output Settings
(page51)
ment) (page52)
6.4.1.1Equipment
Navigation: Home > Settings > Quality management > Test / Adjustment settings > Equipment
This menu item defines the equipment which are required for the following tests:
●
●
●
●
●
For performing temperature adjustment or temperature test, you need the optional temperature adjustment kit,
see Accessories and Spare Parts (page122).
48Settings
Weight adjustment
Weight test
Temperature adjustment
Temperature test
SmartCal test (optional)
Page 49
Test Weight 1 and Test Weight 2
You can define the following parameters:
ParameterExplanationValues
Test weight
name
Nominal weightDefines the nominal weight in grams.0.1…200.000g
IdentificationDefines the identification (ID) of the weight. The ID of the weight
* Factory setting
Temperature kit
You can define the following parameters:
ParameterExplanationValues
Temperature kit
name
IdentificationDefines the identification (ID) of the Temperature kit. The ID is
External humidity sensor
For performing SmartCal tests, you can use the METTLER TOLEDO RHT sensor for the automatically setting of
temperature and humidity values.
Defines a name that is in an easily recognizable form as an alter
native to the ID. A name should be unique and unambiguous.
is provided on the Weight Certificate. The ID may contain your
company specific identification number. This ID is stored in the
adjustment or test history and shows up on the printouts.
Defines a name that is in an easily recognizable form as an alter
native to the ID. A name should be unique and unambiguous.
provided on the Certificate. The ID may contain your company
specific identification number. This ID is stored in the adjustment
or test history and shows up on the printouts.
any
(200g)*
any
any
any
Note
Not applicable for certified RHT sensors, see SmartCal test (page69).
You can define the following parameters:
ParameterExplanationValues
IdentificationDefines the identification (ID) of the RHT sensor. This ID is stored
6.4.1.2Test Settings
Navigation: Home > Settings > Quality management > Test / Adjustment settings > Test settings
Weight test internal
You can define the following parameters:
ParameterExplanationValues
ToleranceDefines the measuring tolerance of the internal weight.0…1%
* Factory setting
Weight test external
You can define the following parameters:
ParameterExplanationValues
Test weightSelects the predefined Test weight.
ToleranceDefines the measuring tolerance of the weight.0.0001…0.1000g
in the test history and shows up on the printouts.
Test weight 1 / Test weight 2 = defined in the menu item Equip
ment
any
(0.001 %)*
Test weight 1 |
Test weight 2
(0.0010 g)*
49Settings
Page 50
* Factory setting
Temperature test
You can define the following parameters:
ParameterExplanationValues
Temperature kitShows the name of the Temperature kit which was defined in the
none
menu item Equipment.
Temperature 1Defines the lower test temperature.
The value is based on the lower adjustment temperature and is
OFF | ON
(100 °C)*
not editable in the temperature test.
ToleranceDefines the tolerance of the test temperature.1…5°C
(3 °C)*
Temperature 2Defines the upper test temperature
The value is based on the upper adjustment temperature.
OFF | ON
(160 °C)*
ToleranceDefines the tolerance of the test temperature.1…5°C
(3 °C)*
Temperature 3
(additional)
Defines an additional test temperature.OFF* | ON |
50…200°C
ToleranceDefines the tolerance of the test temperature.1…5°C
(3 °C)*
* Factory setting
SmartCal test
You can define the following parameters:
ParameterExplanationValues
Lot number
input
Defines the type of input for the Lot number. The Lot number can
be found on the product label.
Free input: Input is not required
ON* | OFF |
Free input |
Guided input *
Guided input: Input is required.
Clear lot num
ber after mea
Enabled or disabled the function for clearing the Lot number after
test measurement.
(enabled)|
(disabled)*
surement
TemperatureDefines the test temperature.
Note
●
The setting of the temperature influences the setting of the
control limits.
●
If custom temperatur is set, the controll limits will be off.
70°C | 100°C* |
130°C | 160°C |
Custom temperature...
40°C…230°C
(105°C*)
50Settings
Page 51
UsecSmartCalSets the controll limits to the correct values for using of cSmart
Cal.
Note
Enabling of cSmartCal affects only the protocol entry but has no
effect to the values of the control limits, if custom temperature
was set.
Control limitsDefines the control limits. The values of the control limits are in
dependence of the temperature setting. The recommended values
are automatically set. The values can also be changed.
The recommended values are (lower - upper limits):
70 °C: 3.2-4.4 %MCN (cSmartCal: 3.3 - 4.3 %MCN)
100 °C: 5.2-6.4 %MCN (cSmartCal: 5.3 - 6.3 %MCN)
130 °C: 7.4-8.8 %MCN (cSmartCal: 7.5 - 8.7 %MCN)
160 °C: 9.9-11.7 %MCN (cSmartCal: 10.0 - 11.6 %MCN)
Note
Control limits are switched off if custom temperature was set.
* Factory setting
6.4.1.3Adjustment Settings
Navigation: Home > Settings > Quality management > Test / Adjustment settings > Adjustment settings
Weight adjustment internal
No editable parameters.
(enabled)|
(disabled)*
values see explanation |
OFF
Weight adjustment external
You can define the following parameters:
ParameterExplanationValues
Test weightSelects the predefined Test weight.
Test weight 1 / Test weight 2 = defined in the menu item Equip
ment
Temperature adjustment
You can define the following parameters:
ParameterExplanationValues
Temperature kitShows the name of the Temperature kit which was defined in the
menu item Equipment.
Temperature 1Defines the lower temperature.80…140°C
Temperature 2Defines the upper temperature140…200°C
* Factory setting
Note
Most samples are measured in the range of 100 ° C and 160 ° C. This is also the factory setting. The range
can be expanded to the range of 80°C and 200°C. The difference between the lower and upper temperature has
to be equal or more than 60°C.
6.4.1.4Print and Output Settings
Test weight 1 |
Test weight 2
none
(100°C)*
(160°C)*
Navigation: Home > Settings > Quality management > Test / Adjustment settings > Print and output set
tings
This menu item allows you to set specific printer functions for test or adjustment printouts.
51Settings
Page 52
●
The setting for printout language in this menu item has impact on test or adjustment printouts only. For set
ting the general printout language, see Print and Export Management (page45).
●
Not all languages are compatible with any printer, and also depending on the settings of the printer, see
Recommended Printer Settings (Strip printer) (page128).
●
For installing and defining a printer see Peripherals (page37).
You can define the following parameters:
ParameterExplanationValues
Printout lan
Defines the printout language for test or adjustment printouts.English| Deutsch|
guage
Print results
Activated or deactivated function. (enabled) |
automatically
after test/adjust
ment
* Factory setting
6.4.1.5FACT (Fully automatic adjustment)
Navigation: Home > Settings > Quality management > Test / Adjustment settings > FACT
This menu item allows you to deactivate or activate fully automatic adjustment function FACT.
Note
●
Before performing an external weight adjustment, we recommend you to disable FACT. Otherwise FACT
overwrites the adjustment.
●
This function is not available for approved models – that is, FACT is always active.
Italiano| Français|
Español| Português|
Polski| Magyar|
Český
(disabled)*
You can define the following parameters:
ParameterExplanationValues
FACTEnabled or disabled fully automatic adjustment FACT function. (enabled)*|
(disabled)
* Factory setting
52Settings
Page 53
6.5User Management
Navigation: Home > Settings > User management
The security system of the instrument is based on a "Users and Groups" concept. Every real user of the instru
ment should be represented by a user account on the instrument which holds particular settings of the respec
tive user. Every user belongs to a particular group and inherits the access rights assigned to that group.
You can define the following parameters:
Menu itemExplanationFurther Information
GroupsDefines groups and their access rights.see Groups (page53)
UsersDefines the user accounts.see Users (page55)
Account policies Set default startup user.see Account Policies (page56)
6.5.1Groups
Navigation: Home > Settings > User management > Groups
In this menu you can create, delete, or edit user groups and define their access rights.
Four predefined groups are available. The default group with all access rights is administrator. The administra
tor group can not be edited or deleted. All other groups can be edited or deleted.
Predefined
groups
Administra
tor
Supervisor
Default access rights
User Pref
erence set
tings
System set
tings
Edit Meth
ods
Run TestsRun Adjust
ments
Quality
manage
ment
User and
data man
agement
Quality
Manager
Operator
Creating a new group
Menu Groups selected.
1 Tap [New...].
2 Enter the name of the new group and confirm with [OK]. Name should be unique and unambiguous.
3 Edit the properties of the new group.
Deleting a group
Menu Groups selected.
1 Select the group you wish to delete.
2 Tap [Delete]. Confirm the message box.
Note
The Administrator group as well as groups with assigned users cannot be deleted, see Users (page55).
Editing a group
Menu Groups selected.
1 Select the group you wish to edit.
2 Edit the group parameters. Store the settings with [Save].
53Settings
Page 54
You can define the following parameters:
ParameterExplanationValues
Group properties Name and (optional) description of the group. Name should be
any
unique and unambiguous.
Access rightsDefines the access rights to menus or operations.User Preference set
tings | System settings
| Edit Methods | Run
Tests | Run Adjust
ments | Quality Man
agement | User and
data management
Group members Displays the users assigned to this group (no editing can be
none
done here, the assignment is done when setting up or editing a
user).
HistoryDisplays the date and time of the last modifications made to this
none
group (no editing here).
Influence of access rights
Access rightsImpact on
User Preference settingsUser preferences
Navigation: Home > Settings > User preferences
See User Preferences (page35)
System settingsSystem settings
Navigation: Home > Settings > System settings
See System Settings (page37)
Edit Methods
Method definition
Navigation: Home > Method definition
See Method Definition (page73)
Application settings
Navigation: Home > Settings > Application settings
See Applications Settings (page44)
Run TestsTests
Navigation: Home > Test/Adjust > Tests
See Tests (page67)
Run AdjustmentsAdjustments
Navigation: Home > Test/Adjust > Adjustments
See Adjustments (page62)
Quality managementQuality management
Navigation: Home > Settings > Quality management
See Quality Management (page48)
User and data management
User management
Navigation: Home > Settings > User management
See User Management (page53)
System and data management
Navigation: Home > Settings > System and data management
See System and Data Management (page57)
Deleting results
See Graphical Evaluations of Measurement Results (page99)
54Settings
Note
●
If password protection is mandatory requirement, the access right User Preference settings must be dis
abled.
●
If a user does not have the appropriate access rights, the respective navigation elements are not shown (on
Home screen) or are disabled (greyed out).
Page 55
6.5.2Users
Navigation: Home > Settings > User management > Users
In this menu you can create, edit, or delete user accounts.
Attention
Important note for the Administrator password.
We recommend that you note down your administrator password and keep it in a safe place. If you forgot the
password for the default administrator access, it is not possible to regain access to the moisture analyzer. In
this case contact your METTLER TOLEDO representative.
Creating a new user account
Note
The user account name must be unique.
Menu Users selected.
1 Tap [New...].
2 Enter the name of the new user account and confirm with [OK].
3 Edit the properties of the new user account.
Editing an existing user account
Menu Users selected.
1 Select the user account you wish to edit.
2 Select menu User properties.
3 Edit the user account parameters.
4 To store the settings, tap [Save].
You can define the following parameters:
ParameterExplanationValues
User nameName of the user account. Name should be unique and unam
Full nameFull name of the user (optional).any
DescriptionDescriptive text for the user account (optional).any
Account activeActivate or deactivate the user account. Inactive user accounts
PasswordCreate a new or change an existing password. OFF = no pass
GroupAssign the user account to a particular group.available groups
* Factory setting
biguous.
are not available for login.
word protection.
any
(deactivated)*|
(activated)
OFF* | ON | any
Note
●
To view the date and time of last modification made to a user account, select the respective account and
tap [History].
●
If password protection is mandatory requirement, the access right User Preference settings must be dis
abled, see Groups (page53).
Deleting a user account
Menu Users selected.
1 Select the user account you wish to delete.
2 Tap [Delete]. Confirm the message box.
Note
You cannot delete the Administrator account or the account that is currently active.
55Settings
Page 56
6.5.3Account Policies
Navigation: Home > Settings > User management > Account policies
In this menu you can set the default startup user.
You can define the following parameters:
ParameterExplanationValues
Default startup
user
* Factory setting
Note
If a non-standard user logs out, the default startup user profile is automatically activated.
Select the default user account for login at startup.OFF | ON* |
available user
accounts
56Settings
Page 57
6.6System and Data Management
Navigation: Home > Settings > System and data management
This menu item allows you to export or import settings and methods to or from an external USB storage device,
as well as to restore the system (depending on the user rights).
Menu structure
Main menuSubmenuFurther information
Result managementAuto-deletesee Result Management (page57)
Export / Import
Back up / Restore
Export event logsExport all event informationsee Export event logs (page59)
Resetno submenusee Reset (page60)
UpdateUpdate your instrument softwaresee Update (page60)
Note for using USB memory sticks
●
Memory sticks up to 32 GB are supported.
●
Recommended formatting: FAT32 (NTFS not supported).
●
Max. cluster size: 32 KB.
●
Max. file size: 32 MB.
●
Make sure that the stick is fully inserted.
●
Make sure that the write protection is deactivated if present.
Export settings and methods to
external storage devices...
Import settings and methods from
external storage device...
Back up your system on external
storage device...
Restore your system from selected
back up...
see Export / Import (page57)
see Back up / Restore (page59)
6.6.1Result Management
Home > Settings > System and data management > Result management
This menu item allows you to manage your results. The Auto-delete functionality prevents the instrument from
filling up with old measurement results by removing them. We advise you to use this function to improve the
performance of your Moisture Analyzer. Is the Auto-delete functionality activated, you can define the number of
stored results with the result limit.
Attention
The default value of the result limit is 1000. If there are more than 1000 results on your Moisture Analyzer, the
system automatically deletes the oldest results. Make sure that important data will periodically be saved on an
external storage.
You can define the following parameters:
ParameterExplanationValues
Auto-deleteActivates the auto-delete functionality and defines the maximal
number of stored result via Result limit.
* Factory setting
6.6.2Export / Import
Navigation: Home > Settings > System and data management > Export / Import
OFF| ON*
1...3000
(1000)*
57Settings
Page 58
This menu item allows you to export or import settings and methods to or from an external storage device.
These data can be transferred to other instruments of the same type and can be useful to configure multiple
instruments with the same specifications.
Note
●
Software Version must be equal or higher.
●
Data transfer from HX models to HS models is limited. Features which are not supported by HS models can
not be imported, e.g. Step drying or high resolution.
●
Export / import of methods can also be performed from the menu Method Definition.
Export settings and methods to external storage devices...
You can define the following parameters:
ParameterExplanationValues
File nameDefines the name of the new data file.any
LocationFinds the location on the storage device.Browse and select
Export selection Defines the data for export.
Note
●
User management and user preferences contains: User
management settings, user preferences
●
System, application and QM settings contains: System set
An external storage device is connected e.g. memory stick.
Settings are made.
– To start, tap [Export].
To abort, tap [Cancel].
Import settings and methods from external storage device...
You can define the following parameters:
ParameterExplanationValues
Import from fileDefines the data to be imported.Browse and select
LocationShows the location of the import file.–
Import selection Defines the data for import.All* | User manage
ment and user prefer
ences |
System, application
and QM settings |
Methods
* Factory setting
Import settings and methods from external storage devices – is selected.
An external storage device is connected e.g. memory stick.
1 Tap Browse and select
Import from file appears.
2 Select Device and import file.
Full menu of Import settings and methods from external storage devices appears.
3 Tap Import selection and select the data for import if needed.
4 To start, tap Import button and follow the instructions in the message window.
To abort, tap [Cancel].
58Settings
Page 59
6.6.3Back up / Restore
Navigation: Home > Settings > System and data management > Back up / Restore
This menu item allows you to create a recovery point of the system and to store them on an external storage
device. We advise you to create a recovery point of the system regularly. So you are able to restore the system
with all data in fault.
Attention
●
After restoring, the system is in backup status. That means, that newer data such as settings, methods or
results are lost.
●
Restore is only possible on the same instrument as the back up was carried out.
Backup
You can define the following parameters:
ParameterExplanationValues
File nameDefines the name of the new data file.any
LocationFinds the location on the storage device.Browse and select
Procedure:
An external storage device is connected e.g. memory stick.
Back up your system on external storage device... – is selected.
1 Define the name of the new data file.
2 Define the location on the storage device.
3 To confirm, tap [OK].
4 To start, tap [Backup].
To abort, tap [Cancel].
Restore
You can define the following parameters:
ParameterExplanationValues
Restore from file Finds the location on the storage device and selects the file for
Procedure:
Restore your system from selected back up... – is selected.
An external storage device is connected e.g. memory stick.
1 Tap Restore from file... (Browse and select).
Storage device appears.
2 Select the file for restoring.
3 To start, tap [Restore].
To abort, tap [Cancel].
Confirmation window appears.
4 Confirm with [Restore].
The system will restore the data and then perform a restart. Wait until the system has completely started up
again.
6.6.4Export event logs
Browse and select
restoring.
Navigation: Home > Settings > System and data management > Export event logs
59Settings
Page 60
This menu item allows you to export a log file (Zip format) with all relevant data to an external storage device.
These data can be used for example, to support METTLER TOLEDO for troubleshooting.
You can define the following parameters:
ParameterExplanationValues
File nameDefines the name of the new data file.any
Export targetDefines the destination of data transfer. Peripheral |
Network (FTP)
Export target: Peripheral
ParameterExplanationValues
LocationFinds the location on the storage device.Browse and select
* Factory setting
Export target: Network (FTP)
For data transfer over a network (Ethernet and WLAN) the File Transfer Protocol FTP is used. The receiving serv
er is defined by entry of the appropriate IP address. If necessary, contact the network administrator of your IT
department or your IT support.
ParameterExplanationValues
IP addressDefines the IP address of the receiving server.any
PortDefines the Port for communication with the server.
Note
Usually the default value is used.
PasswordEntry for the password needed for server login.any
User nameEntry for the user name needed for server login.any
File typeDefines the type of the data file.CSV* | PDF
* Factory setting
21* | any
6.6.5Reset
Navigation: Home > Settings > System and data management > Reset
This menu item allows you to reset the Instrument to factory settings. Date, time, weight and temperature
adjustments/history are not affected.
You can define the following parameters:
ParameterExplanationValues
ResetResets the instrument to factory settings.none
6.6.6Update
Navigation: Home > Settings > System and data management > Update
Note
This function is not available with approved instruments. For update, contact your METTLER TOLEDO represen
tative.
METTLER TOLEDO is continuously improving its instrument firmware (software) for the benefit of customers. So
that the customer can benefit quickly and easily from further developments, METTLER TOLEDO makes the latest
CAUTION
Data loss after system reset.
After resetting, the instrument is in state as delivered. That means, that all data such as set
tings, methods or results are lost.
– We recommend you to save first the appropriate data on an external storage device, see
Export / Import (page57) and Back up / Restore (page59).
60Settings
Page 61
firmware versions available on the Internet. The firmware made available on the Internet has been developed
and tested by Mettler-Toledo AG using processes that meet the guidelines of ISO 9001. Mettler-Toledo AG does
not, however, accept liability for consequences that might arise from using the firmware.
Update procedure
1 Connect to the Internet.
2 Go to the site http://www.mettler-toledo-support.com.
3 Log in to the METTLER TOLEDO Balance Support Site (registration with the serial number of a METTLER
TOLEDO instrument required).
4 Click Customer Support.
5 Click appropriate product folder e.g. HX204 or HS153.
6 Click Latest Firmware and Update Support.
7 Important: Before updating read the downloadable supplementary sheet carefully. This document provides
you with the relevant information for updating to the new firmware version.
61Settings
Page 62
7Test/Adjust
Navigation: Home > Test/Adjust
This function offers you to adjust or test the integrated balance and the heating module. For the relevant settings
see Test / Adjustment settings (page48).
Menu structure
Weight test - internalsee Weight test - internal (page67)
Weight test - externalsee Weight test - external (page67)
Temperature testsee Temperature test (page68)
SmartCal testsee SmartCal test (page69)
Weight test history
Weight adjustment history
Temperature adjustment history
Temperature test history
SmartCal test history
see History (page72)
7.1Adjustments
Navigation: Home > Test/Adjust > Adjustments
In this menu item you can adjust the balance as well as the heating module of your instrument. For relevant
settings see Test / Adjustment settings (page48).
Attention
●
To obtain accurate results, the balance must be adjusted at the point of use under measuring condition in
order to match the gravitational acceleration at its location. The instrument must be connected to the power
supply for approximately 60 minutes in order to reach operating temperature before adjusting. Adjusting is
necessary:
•
before the instrument is used for the first time.
•
after a change of location.
●
We advice you to wait at least 30 minutes after a drying operation (or previous heating module adjustment)
before performing the adjustment.
Fully automatic adjustment FACT
This instrument is equipped with fully automatic adjustment with two internal weights called Fully Automatic
Calibration Technology (FACT).
The balance adjusts itself automatically:
●
after the warm-up phase after connection to the power supply.
●
when a change in the ambient conditions (temperature) could lead to a noticeable deviation in the mea
surement.
●
on a fixed time interval
62Settings
FACT is activated by default and can be switched off as required e.g. when performing an external adjustment,
see FACT (Fully automatic adjustment) (page52).
Navigation: Home > Settings > Quality management > Test / Adjustment settings > FACT
Page 63
Note
With approved models FACT cannot be switched off.
This function allows you to adjust the balance with the built-in weights. The internal adjustment is equivalent to
the FACT adjustment.
Perform this function as follows:
1 Tap the menu item Weight adjustment - internal.
The adjustment screen appears.
2 Clear pan and tap [Start adjustment].
The balance adjusts itself automatically.
The instrument indicates when the adjustment process is done. The balance is adjusted and ready to use
for further measurements. The display shows the adjustment results. The results can be printed out by tap
ping [ ].
This function allows you to adjust the balance using an external weight. We recommend to use certified weights
so that full traceability is guaranteed.
Note
We recommend you to disable FACT. Otherwise FACT overwrites the adjustment.
Perform this function as follows:
FACT is off.
Test weight and Adjustment settings are defined.
see Test / Adjustment settings (page48)
1 Have required test weight ready.
2 Tap the item Weight adjustment - external.
The adjustment screen appears.
3 Clear sample pan holder and tap [Start adjustment].
Note
We recommend not to use a pan.
The required value flashes and prompts you to load the weight, e.g. "100.00 g".
4 Load the required test weight in the center of sample pan holder.
The balance indicates the adjustment process, "––––––" appears.
5 When the display flashes "000.00" remove the test weight.
The balance is adjusted and ready to use for further measurements. The display shows the adjustment
results. The results can be printed out by tapping [ ]
Note
After a timeout the error message appears Weight out of range.The adjustment has been aborted The
adjustment was not executed.
1 Confirm with [OK].
2 Remove the test weight for unloading.
3 Repeat the adjustment.
63Test/Adjust
Page 64
7.1.3Temperature Adjustment
1
23
Navigation: Home > Test/Adjust > Adjustments > Temperature adjustment
This function allows you to adjust the temperature control of the heating module. You need the optional Tem
perature kit for performing this function, see Accessories and Spare Parts (page122). To learn when an
adjustment of the heating module is necessary, see Notes on Adjustment of Balance and Heating Module
(page127). We advise you to wait at least 30 minutes after a drying operation (or previous heating module
adjustment) before performing the adjustment.
Note
●
The duration of the temperature adjustment is 30 minutes. (15 minutes for each measuring temperature).
●
The sample chamber must be less than 50 °C before a further adjustment or test can be done.
●
It is also possible to perform a test first, and then to transform the test into an adjustment if required. Only
possible for tests conducted with 2 temperatures, see Temperature test (page68).
●
For temperature adjustment settings see Adjustment Settings (page51).
CAUTION
Danger of burns
Sample chamber may still be hot.
– Cool down instrument before setting up.
Adjustment settings are defined, see Adjustment Settings (page51).
– Tap menu item Temperature adjustment.
Work screen Temperature adjustment appears.
Setting up Drying Unit
Have required Temperature kit ready.
Instrument is on
Sample chamber is open.
Instrument is cooled down.
1 Remove sample pan handler (with pan) (1).
2 Remove sample pan holder (2).
3 Contact areas (3) should be clean. Clean them if
needed.
Note
Do not remove draft shield.
64Test/Adjust
Page 65
– Insert Temperature kit (4).
4
Start adjustment
Draft shield is installed.
Temperature kit is inserted.
1 Tap [Start adjustment].
Note
The adjustment process takes 30 minutes.
The instrument starts the adjustment process. The screen shows the current temperature and the remain
ing time.
The instrument heats up to the target temperature 1 for determining the predefined lower temperature.
After 15 minutes, the instrument adjusts the lower temperature and continues with the process.
The instrument heats up to the target temperature 2 for determining the predefined upper temperature.
After 15 minutes, the instrument adjusts the upper temperature and concludes the adjustment.
2 • To print out the results, tap [].
• To display or print out the results of previous adjustments, tap [History].
• To return to the home screen, tap [ ].
3 After cooling down, remove Temperature kit and set up drying unit for measurement.
See History (page72) and Setting up Drying Unit (page26)
Note
Your calibrated temperature adjustment kit can be re-calibrated. Please contact your local METTLER TOLEDO
representative for more information.
65Test/Adjust
Page 66
7.1.4Adjustment Printout Examples
-WEIGHT ADJUST INTERNAL-
03.07.2013 11:51
METTLER TOLEDO
Halogen MoistureAnalyzer
Type HX204
SNR(Drying Unit)
0123459789
SNR(Terminal) 9876543210
Nominal Weight
100.000 %
Cell temperature
24.60 °C
Balance is levelled
Adjustment Done
Last Weight Test
02.05.2014 11:34
Last Weight Adjustment
02.05.2014 16:38
Signature:
........................
---------- END ---------
-WEIGHT ADJUST EXTERNAL-
03.07.2013 11:51
METTLER TOLEDO
Halogen MoistureAnalyzer
Type HX204
SNR(Drying Unit)
1234567890
SNR(Terminal) 0987654321
User name Administrator
Weight ID ECW-100/1
Nominal Weight
100.000 g
Cell temperature
25.20 °C
Balance is levelled
Adjustment Done
Last Weight Test
02.05.2014 11:34
Last Weight Adjustment
02.05.2014 16:38
Signature
........................
---------- END ---------
-TEMPERATURE ADJUSTMENT-
03.07.2013 11:51
METTLER TOLEDO
Halogen MoistureAnalyzer
Type HX204
SNR(Drying Unit)
1234567890
SNR(Terminal) 0987654321
User name Administrator
Temp Kit ID MT-414/A
Temp1 target 100.0 °C
Temp1 actual 97.0 °C
Temp2 target 160.0 °C
Temp2 actual 162.0 °C
Adjustment Done
Last Temperature Test
02.05.2014 11:34
Last Temperature
Adjustment
02.05.2014 16:38
Signature:
........................
---------- END ---------
Weight adjustment internal
Weight adjustment external
Temperature adjustment
66Test/Adjust
Page 67
7.2Tests
Navigation: Home > Test/Adjust > Tests
In this menu item you can check the adjustment of the balance as well the temperature of the heating module.
For relevant settings see Test / Adjustment settings (page48).
7.2.1Weight test - internal
Navigation: Home > Test/Adjust > Tests > Weight test - internal
This function allows you to test the balance with the built-in weight. Perform this function as follows:
Test settings are defined (Factory setting of the tolerance is 0.0010%)
see Test / Adjustment settings (page48)
1 Open sample chamber
2 Tap the item Weight test - internal.
The test screen appears.
3 Clear pan and tap [Start test].
The balance is tested automatically.
When the test process is done, the display shows the test results and indicates whether the test is passed or
failed according to defined tolerances.
The test results can be printed out by tapping [ ].
7.2.2Weight test - external
Navigation: Home > Test/Adjust > Tests > Weight test - external
This function allows you to test the balance using an external weight. Perform this function as follows:
Test weight and test settings are defined.
see Test / Adjustment settings (page48)
1 Have required test weight ready.
2 Open sample chamber.
3 Tap the item Weight test - external.
The test screen appears.
4 Clear sample pan holder and tap [Start test].
Note
We recommend not to use a pan.
The required value flashes and prompts you to load the weight.
5 Load the required test weight.
The balance indicates the test process, "––––––" appears.
6 When the display flashes "000.00" remove the test weight.
When the test process is done, the display shows the test results and indicates whether the test is passed or
failed according to defined tolerances. The results can be printed out by tapping [ ].
Timeout
After a timeout of 75 seconds the error message appears Weight out of range.The test has been aborted.
The test was not executed.
1 Confirm with [OK].
2 Repeat the test.
67Test/Adjust
Page 68
7.2.3Temperature test
Navigation: Home > Test/Adjust > Tests > Temperature test
This function allows you to test the temperature control of the heating module. You need the optional Tempera
ture Kit for performing this function, see Accessories and Spare Parts (page122). To learn when an test of the
heating module is necessary, see Notes on Adjustment of Balance and Heating Module (page127). We advise
you to wait at least 30 minutes after a drying operation (or previous heating module adjustment) before per
forming a test.
Note
●
The duration of the temperature test is 15 minutes for each measuring temperature.
●
The sample chamber must be cooled down below 50 °C before a further adjustment or test can be done.
●
It is possible to perform a test and then subsequently to transform the test into an adjustment if required.
This is only possible for tests conducted with temperatures 1 and 2.
●
Temperature test settings see Test Settings (page49).
Setting up the Drying Unit for temperature test
Same procedure as for temperature adjustment, see Temperature Adjustment (page64).
CAUTION
Danger of burns
Sample chamber may still be hot.
– Cool down instrument before setting up.
Performing temperature test
Test settings are defined, see Test Settings (page49).
Setting up the drying unit for temperature testing has been carried out.
1 Tap menu item Temperature test.
Work screen Temperature test appears.
2 Tap [Start test].
Note
The testing process takes 15 minutes for each temperature (depending on the settings).
The instrument starts the testing process. The screen shows the current temperature and remaining time.
The instrument is heating up to the target temperature 1 for determining the predefined lower tempera
ture.
After 15 minutes, the instrument displays and stores the measured lower temperature and continues
with the process.
The instrument is heating up to the target temperature 2 for determining the predefined upper tempera
ture.
After 15 minutes, the instrument displays and stores the measured upper temperature.
If temperature 3 is defined, the procedure has an additional step.
The test is done and indicates whether the test has passed or failed according to defined tolerances.
3 Decide if an adjustment is needed.
4 • To return to the menu Tests, tap [Tests].
• To print out the results, tap [ ].
• To display or print the results at any time, tap [History].
• To return to the home screen, press [ ].
5 After cooling down, remove temperature adjustment kit and set up drying unit for measurement, see Setting
up Drying Unit (page26).
68Test/Adjust
Page 69
7.2.4SmartCal test
What is SmartCal™?
Proper operation of the Halogen Moisture Analyzer can be quickly verified with a SmartCal test. SmartCal is a
granular test material with a defined moisture value after a specified time at a defined drying temperature.
SmartCal is available for four test temperatures. There are control limits for each test temperature. If the mea
sured and normalized moisture value is within the control limits, the instrument has passed the functional test.
If value is outside the control limits, there may be a problem with the instrument or the test conditions may not
have been met.
Test temperatures and control limits
cSmartCal (certified) and SmartCal can be used for testing at any temperature between 70°C and 230°C.
METTLER TOLEDO provides established control limits for testing at 70°C, 100°C, 130°C and 160°C.
Select the temperature closest to the drying temperature normally used.
MCN = Normalized moisture content (Calculated value in consideration of temperature and humidity)
Note about using SmartCal
●
Store SmartCal at room temperature.
●
Do not open the blister pack before use.
●
Shelf life: The expiry date is printed on the blister pack and on the stick (e.g. Exp08.2013).
●
Disposal: Can be disposed of as normal waste. Observe local and national environmental regulations.
Additional information on using SmartCal, e.g. SmartCal user guide, see
u www.mt.com/smartcal
Performing SmartCal™ test
Navigation: Home > Test/Adjust > Tests > SmartCal test
The test is carried out in the same way as a measurement. The duration of the test is 10 minutes.
The Instrument is acclimatized in working area, cooled and connected to AC power for at least one hour.
The SmartCal package is acclimatized in working area.
The expiration date of the Smart Call sample has not been reached.
The METTLER TOLEDO RHT sensor is properly installed and acclimatized in working area after installing for
at least one hour. If no RHT sensor is available, room temperature and humidity must be enter manually,
see Install METTLER TOLEDO RHT sensor (page29).
Alternatively:
– you can use a certified RHT sensor from Testo, see note at the end of this Chapter.
– you can enter the temperature and humidity manually.
Identification of the METTLER TOLEDO RHT sensor if needed, see Equipment (page48)
Test temperature and control limits are set, see Test Settings (page49)
1 Tap SmartCaltest.
Sample chamber opens.
2 If no RHT sensor is used, enter current room temperature and humidity. Tap [OK]
3 Enter SmartCal lot number if needed. Tap [OK]
4 Place the sample pan handler with the aluminum sample pan in the instrument.
69Test/Adjust
Page 70
5 Tap [->0/T<-] to tare the balance.
6 Remove a SmartCal stick from the blister pack, tear it open, and distribute the entire contents evenly over the
sample pan. If necessary, carefully rotate and tilt the sample pan until it is fully and uniformly covered with
granulate.
7 Start the test immediately by tapping start drying.
SmartCal test is performing.
The test is done and indicates whether the test has passed or failed. The display shows the normalized
result.
●
Passed: Your instrument works properly and is ready for other measurements.
●
Failed: Your instrument works not properly. Action are required:
•
See What to Do if… (page114)
•
We recommend not to use this instrument further until the problem is resolved. In this case contact your
METTLER TOLEDO representative.
– • To return to the menu Tests, tap [Tests].
• To print out the results, tap [ ].
• To display or print the results at any time, tap [History].
• To return to the home screen, press [ ].
Note
SmartCal tests do not supersede the recommended periodic weight or temperature tests.
Certified RHT sensors
The RHT sensor from METTLER TOLEDO in not available as a certified version. If an certified version is required,
the following RTH models from testo are supported: testo 435-2, testo 435-4, testo 635-2, testo 735-2.
The Testo RHT sensor has to be connected on the USB port on the terminal. If both RHT sensors are connected,
the testo RHT sensor has priority.
For more information about Testo, see
u http://www.testo.com
70Test/Adjust
Page 71
7.2.5Test Printout Examples
--WEIGHT TEST INTERNAL--
03.07.2013 11:51
METTLER TOLEDO
Halogen MoistureAnalyzer
Type HX204
SNR(Drying Unit)
1234567890
SNR(Terminal) 0987654321
Nominal Weight
100.0000 %
Actual Weight
99.9994 %
Difference -0.0006 %
Tolerance +/-0.0010 %
Cell temperature
24.30 °C
Balance is levelled
Test passed
Last Weight Test
02.05.2014 11:34
Last Weight Adjustment
02.05.2014 16:38
Signature:
........................
---------- END ---------
--WEIGHT TEST EXTERNAL--
03.07.2013 11:51
METTLER TOLEDO
Halogen MoistureAnalyzer
Type HX204
SNR(Drying Unit)
1234567890
SNR(Terminal) 0987654321
User name Administrator
Weight ID ECW-100/1
Nominal Weight
100.0000 g
Actual Weight
101.3198 g
Difference 1.3198 g
Tolerance +/- 0.001 g
Cell temperature
23.83 °C
Balance is levelled
Test Failed
Last Weight Test
02.05.2014 11:34
Last Weight Adjustment
02.05.2014 16:38
Signature:
........................
---------- END ---------
----TEMPERATURE TEST----
03.07.2013 11:51
METTLER TOLEDO
Halogen MoistureAnalyzer
Type HX204
SNR(Drying Unit)
1234567890
SNR(Terminal) 0987654321
User name Administrator
Temp Kit ID MT-414/A
Temp1 target 100.0 °C
Temp1 actual 99.0 °C
Temp1 tolerance
+/- 3.0 °C
Temp2 target 160.0 °C
Temp2 actual 159.0 °C
Temp2 tolerance
+/- 3.0 °C
Test passed
Last Temperature Test
02.05.2014 11:34
Last Temperature
Adjustment
02.05.2014 16:38
Signature:
........................
---------- END ---------
Weight test internal
Weight test external
Temperature test
71Test/Adjust
Page 72
7.3History
Navigation: Home > Test/Adjust > History
The instrument always records all test or adjustment operations that have been made and saves them in a
memory which is specially protected against power failure (limited to the last 50 records per history selection).
Note
Aborted adjustments or tests will not be saved.
When the History is selected, a list appears with the history selection as follows:
●
Weight test history
●
Weight adjustment history
●
Temperature test history
The following information is displayed:
Weight test history
Weight test externalWeight test internal
Calibration weight identificationNominal weight100 %
Nominal weight gActual weight%
Actual weight gDifference%
Difference gTolerance%
TolerancegTemperature°C
Temperature °CLeveling information
Leveling information
Calibration weight nameTemperature°C
Calibration weight identificationLeveling information
Nominal weight g
Temperature °C
Leveling information
Temperature adjustment/test history
Temperature adjustmentTemperature test
Adjustment kit identificationAdjustment kit identification
Temperature 1target - actualTemperature 1target - actual
Temperature 2target - actualTemperature 2target - actual
Free temperaturetarget - actual
Tolerances for each temperature°C
SmartCal test history
SmartCal test
User name
SmartCal Identification
Start weightg
Total test timeminutes
Dry weight%MCN
Test resultpassed / failed
Date and time
Leveling information
72Test/Adjust
The selected individual results can be printed out by tapping [ ].
Page 73
8Method Definition
Navigation: Home > Method definition
What is a method?
Methods simplify and accelerate your daily work. A method contains all settings for measuring the moisture
content of a particular sample (substance). It can be recalled by tapping a measurement button or a shortcut
and your instrument immediately operates with the corresponding settings.
The optimal setting of parameters and the drying time depends on the type and size of the sample and the
desired accuracy of the measurement result. The exact parameters can only be determined experimentally, see
How to Obtain Best Results (page127). Your Instrument helps you to determine the settings.
Method definition
This function offers you to define new methods and to change, delete, export or import existing methods
depending on the user rights. It allows you to store up to 300 individual methods.
All parameters using in a drying method, can be defined under this menu item.
Note
●
In most cases it is sufficient to set Main measurement parameters.
●
You will find more information about defining methods in the delivered application brochure «Guide to Mois
ture Analysis» or see How to Obtain Best Results (page127).
Prerequisite
The parameter menu appears only if a method already exists and is selected in the method definition dialog or
create a new method.
Menu structure
Main menuSubmenuFurther information
Main measurement parame
ters
Result and value handling
General method propertiesMethod namesee Method name (page91)
Drying program
(including temperature and switch-off
criteria)
Display modesee Settings of Display Mode
Start weightsee Settings of Start Weight
Control limitssee Control limits (page86)
Resolutionsee Resolution (page87)Free factorsee Free Factor (page88)
2 Enter a name for the new method. Name should be unique and unambiguous.1 to 30 characters are possi
ble (including spaces).
3 Confirm with [OK].
The parameter menu for the new method appears.
4 Set the desired parameters e.g. Main measurement parameters.
5 To store the method, tap [Save].
Editing an existing method
Method definition is selected.
1 Tap the method in the list you want to edit.
The parameter menu for the selected method appears.
2 Edit the desired parameters e.g. Main measurement parameters.
3 To store the method, tap [Save].
Copying an existing method
Method definition is selected.
1 Tap the method in the list you want to copy.
The parameter menu of the desired method appears.
2 Tap [Save as...].
The keypad appears.
3 Enter a new name for the copied method. Name should be unique and unambiguous.1 to 30 characters are
possible.
4 To store the method, tap [Save].
Removing an existing method
Note
All results of this method are also removed.
Method definition is selected.
1 Tap the method in the list you want to remove.
The parameter menu of the desired method appears.
2 Tap [Delete].
A message box appears.
3 Confirm with [Delete].
The desired method is removed.
Note
A possible shortcut to this method is not removed.
For removing shortcuts see Using Shortcuts (page97)
74Method Definition
Page 75
8.1Main Measuring Parameters
Navigation: Home > Method Definition > Method name > Main measurement parameters
These parameters are relevant for measuring and must be determined for all samples. Most samples can be
determined with these parameters.
You can define the following parameters:
Menu itemExplanationFurther Information
Drying programDefines the drying program which is best suited for
the specific sample. (including temperature and
switch-off criteria)
Display modeDefines the type of value for displaying and printing. see Settings of Display Mode
Start weightDefines a start weight so that the samples always
have approximately the same weight .
8.1.1Settings of Drying Program
Navigation: Home > Method Definition > Method name > Main measurement parameters > Drying pro
gram
This function offers you different predefined drying programs for optimum matching of the drying characteristics
to the sample used. Furthermore, the drying temperature, switch-off criterion as well as the start weight can be
set. Carry out a test measurement for determining the appropriate switch-off criterion, if you do not know the
behavior of the sample. For carry out a test measurement see Testing a Method (page92).
Note
You will find more information about defining methods in the delivered application brochure «Guide to Moisture
Analysis».
You can define the following parameters:
ParameterExplanationValues
Drying programDefines the drying program which is best suited for the specific
sample.
* Factory setting
Further information:
●
Standard drying see Settings of Standard drying (page75)
●
Rapid drying see Settings of Rapid drying (page76)
●
Gentle drying see Settings of Gentle drying (page77)
●
Steps drying see Settings of Step drying (page79)
see Setting the Drying Program
(page75)
(page82)
see Settings of Start Weight
(page85)
Standard*| Rapid|
Gentle| Steps
8.1.1.1Settings of Standard drying
Standard drying
This drying program is set in the factory and is suitable for most samples. The sample is
heated to the drying temperature.
Factory setting
Drying temperature = 105 °C, Switch-off criterion 3 = 1 mg / 50 s
75Method Definition
Page 76
You can define the following parameters:
ParameterExplanationValues
Drying tempera
ture
Switch-off crite
rion
SOC delayActivates and defines the delay for the starting time of the switch-
Setting the Drying Temperature
Navigation: Method Definition > Name of method > Main measurement parameters > Drying temperature
In this menu item you can set the final drying temperature.
Note:
The admissible input range for the drying temperature is indicated.
Defines the drying temperature. 40…230 °C
(105 °C *)
Defines the criterion when the instrument should end the drying.1 (1 mg / 10 s)|
Setting Switch-off criterion
see Settings of Switch-off Criterion (SOC) (page80)
8.1.1.2Settings of Rapid drying
Rapid drying
This drying program is primarily suitable for samples with a moisture content over 30%.
Following the start, the selected temperature is exceeded by 40% for 3 minutes (however,
is possible up to maximum 230°C) to compensate for the cooling due to vaporization and
accelerate the drying process. The drying temperature is then lowered to the set value and
maintained.
Factory setting
Drying temperature = 105 °C, Switch-off criterion 3 = 1 mg / 50 s
76Method Definition
Page 77
You can define the following parameters:
ParameterExplanationValues
Drying tempera
ture
Switch-off crite
rion
* Factory setting
Setting the Drying Temperature
Navigation: Method Definition > Name of method > Main measurement parameters > Drying temperature
In this menu item you can set the final drying temperature.
Note:
The admissible input range for the drying temperature is indicated.
Defines the drying temperature. 40…230 °C
(105 °C *)
Defines the criterion when the instrument should end the drying.1 (1 mg / 10 s)|
Setting Switch-off criterion
see Settings of Switch-off Criterion (SOC) (page80)
8.1.1.3Settings of Gentle drying
Gentle drying
This drying program is suitable for the gentle drying of substances which tend to form a
skin (e.g. substances containing sugar or volatile substances). With this program the temperature is continuously increased and attains the selected drying temperature only after
the elapse of the so-called ramp time. The «ramp», i.e. the time that should elapse
between the start of drying and attainment of the final temperature can be pre-set.
Factory setting
Drying temperature = 105 °C, Ramp time = 3:00 min,
Switch-off criterion 3 = 1 mg / 50 s
77Method Definition
Page 78
You can define the following parameters:
ParameterExplanationValues
Drying tempera
ture
Ramp timeDefines the time in minutes that should elapse between the start
Switch-off crite
rion
* Factory setting
Setting the Drying Temperature
Navigation: Method Definition > Method name > Main measurement parameters > Drying
programGentleDrying temperature
In this menu item you can set the desire final drying temperature.
Defines the drying temperature. 40…230 °C
(105 °C *)
0…480 min
of drying and attainment of the final temperature for Gentle dry
ing.
Defines the criterion when the instrument should end the drying.1 (1 mg / 10 s)|
Setting the ramp time
Navigation: Method Definition > Method name > Main measurement parameters > Drying programGentle
> Ramp time
In this menu item you can define the Ramp time, i.e. the time that should elapse between the start of drying
and attainment of the final temperature. The ramp is started once the temperature reaches 50°C.
1 Start of drying
2 Final temperature
3 Ramp time
Setting Switch-off criterion
see Settings of Switch-off Criterion (SOC) (page80)
78Method Definition
Page 79
8.1.1.4Settings of Step drying
Step drying
This drying program is suitable for the drying of substances composed of several compo
nents which vaporize at different temperatures (e.g. ethereal oils). With this program drying
is performed stepwise, i.e. the sample is preheated to a particular temperature (1st step)
and kept at this temperature for the selected switch-off criterion e.g. time or weight loss per
unit of time. The temperature can be increased for the next step, lowered or remain the
same. At the last step, the switch-off criterion terminates the measurement. Maximum 5
steps are selectable.
Step drying can also be used for faster determining of samples with high moisture content.
In this case the first step should be set with a higher temperature than for the last step. This
reduces evaporation.
Tip for the measurement of plastic granules:
Setting of switch-off criterion "timed" for the first step (possibly same temperature setting as
for step 2). The larger sample (e.g. 30 g) has to be heated first before it gives off the small
amount of moisture. This prevents that the measurement is terminated prematurely. Setting
of switch-off criterion "5" for the second step which terminates the measurement automati
cally.
Factory setting
Step 1, Temperature = 50 °C, Switch-off criterion = 5:00 min
Step 2, Temperature = 105 °C, Switch-off criterion 3 = 1 mg / 50 s
You can define the following parameters:
ParameterExplanationValues
Drying stepsDefines the number of steps for Step drying. This dialog includes
the setting of temperature and switch-off criterion for each step.
TemperatureDefines the drying temperature for each Step.50…230 °C
Switch-off crite
rion
* Factory setting
Drying steps
Navigation: Method Definition > Method name > Main measurement parameters > Drying programSteps >
Drying steps
Defines the criterion when the instrument should end the drying
or should start the next step.
1 Start of drying
2 Step temperature
3 Next step, Switch-off criterion
4 Last step
Setting Switch-off criterion
see Settings of Switch-off Criterion (SOC) (page80)
79Method Definition
Page 80
8.1.1.5Settings of Switch-off Criterion (SOC)
Navigation: Home > Method Definition > Method name > Main measurement parameters > Drying pro
gram
This function offers you different switch-off criteria. A switch-off criterion defines when the instrument should end
the drying or should start the next step ("Step drying"). Switch-off criteria ensure that measurements are finished
in the same condition (weight loss per unit of time) every time, ensuring repeatable measurements.
Note
Accurate results require same start weights, see Settings of Start Weight (page85).
You can define the following parameters:
ParameterExplanationValues
Switch-off crite
rion
* Factory setting
●
Weight loss per unit of time (5 preprogrammed settings)
●
Free switch-off criterion (2 different settings)
●
Timed switch-off
Defines the criterion when the instrument should end the drying.1 (1 mg / 10 s)|
The switch-off defines in which drying condition, the measurement is completed. This switch-off is based on a
weight loss per unit of time. As soon as the mean weight loss is less that a preset value during a specified
time, the instrument considers drying as complete and automatically discontinues the measurement process.
Note
The switch-off criterion is inactive during the first 30 sec.
The following 5 preprogrammed settings are available
Switch-off
Δ g Δ tDescription
criterion
11 mg10 sThis setting is suitable for fast measurements to determine a trend.
21 mg20 sThis setting is suitable for quick drying samples.
31 mg50 sThis is the factory setting. It is suitable for most kind of samples.
41 mg90 sThis setting is suitable for samples which dry moderately quickly or for
samples with higher accuracy requirements.
51 mg140 sThis setting is suitable for samples which dry very slowly (trapped
moisture, skin formation) or for samples with very low moisture con
tent e.g. plastics. Not suitable for very temperature sensitive samples.
The graph below exemplifies the mode of operation of the switch-off operation (not to scale).
80Method Definition
Page 81
∆g
∆g
∆g
∆ g
∆ t
(
)
∆t
(10 s)
∆t
(1
40 s)
∆t
(50 s)
t
1)
2)
1 (1 mg / 10 s)3 (1 mg / 50 s)5 (1 mg / 140 s)
W
W
=
=
t=time1)=equal area
W=weight of sample2)=mean weight loss per unit of time
1, 3, 5=switch-off criteria shown as an example
Free switch-off criterion
The free switch-off criterion is based on a user-defined mean weight loss per unit of time.
The following 2 settings are available:
●
Switch-off criterion > Free (mg / s)... (weight loss per unit of time)
●
Switch-off criterion > Free (% / s)... (weight loss in percent per unit of time)
Timed switch-off
With this switch-off criterion the measurement lasts until the pre-set drying time has elapsed. The display pro
vides you with continuous information in the drying time.
Performing Test measurements
For performing test measurements to determine a correct switch-off criterion, see Testing a Method (page92).
81Method Definition
Page 82
8.1.1.6Settings of SOC Delay
Navigation: Home > Method Definition > Method name > Main measurement parameters > SOC delay
With this function you can delay the starting time of the switch-off criterion. This can be useful for samples with
low moisture content which need extended time until they evaporate moisture e.g. plastics.
Note
SOC delay is only available for the following drying programs:
●
Standard
●
QuickPredict
You can define the following parameters:
ParameterExplanationValues
SOC delayActivates and defines the delay for the starting time of the switch-
off criterion.
OFF = no delay applied.
* Factory setting
8.1.2Settings of Display Mode
Navigation: Home > Method Definition > Method name > Main measurement parameters > Display Mode
With this function you can select the desired type of result display. You also define what type of values are
printed on the records.
You can define the following parameters:
ParameterExplanationValues
Display ModeDefines the type of value for displaying and printing.%MC*| %DC| %AM|
Calculated values are indicated with an asterisk in the display.
Detailed information:
82Method Definition
Page 83
%MC – Moisture Content
WW
DW
MC
MC
WW
DW
WW
=
–
· 100 %
DC
DW
WW
=
· 100 %
The moisture content of the sample is displayed (and printed out) as a
percentage of the wet weight (WW = initial weight = 100 %). This is the
factory setting.
During the measurement the value is constantly displayed in percent and
as a graphical drying curve. The measured value is marked by "%MC"
(Moisture Content, e.g. 11.35 %MC) also for the printed results.
The dry content of the sample is displayed (and printed out) as a per
centage of the wet weight (WW = initial weight = 100 %).
During the measurement the value is constantly displayed in percent and
as a graphical drying curve. The measured value is marked by "%DC"
(Dry Content, e.g. 88.65 %DC) also for the printed results.
The moisture content of the sample is displayed (and printed out) as a
percentage of the dry weight (DW = final weight = 100 %)
During the measurement the value is constantly displayed in percent and
as a graphical drying curve. The measured value is marked by "%AM"
(ATRO Moisture Content, e.g. 255.33 %AM) also for the printed results.
The wet weight of the sample is displayed (and printed out) as a per
centage of the dry weight (DW = final weight = 100 %)
During the measurement the value is constantly displayed in percent and
as a graphical drying curve. The measured value is marked by "%AD"
(ATRO Dry Content, e.g. 312.56 %AD) also for the printed results..
If the current measured value in the ATRO display mode is greater or less than the predefined limit value (i.e.
greater than 999.99 %AD or less than –999.99 %AM), the ATRO result values are limited to 999.99%.
g – Weight in Grams
The weight of the sample is displayed (and printed out) in grams. With
this setting, the Moisture Analyzer is used as a precision balance.
During the measurement current weight is constantly displayed in
grams.
84Method Definition
g/kg MC – Moisture Content
The moisture content of the sample is displayed (and printed out)in g/kg
of the wet weight (WW = initial weight = 1000 g/kg).
During the measuremnet the current measured value is constantly dis
played in percent and as a graphical drying curve. The measured value
is marked by "g/kg MC" (Moisture Content, e.g. 11.35 g/kg MC) also for
the printed results.
The dry content of the sample is displayed (and printed out) in g/kg of
the wet weight (WW = initial weight = 1000 g/kg).
During the measuremnet the current measured value is constantly dis
played in percent and as a graphical drying curve. The measured value
is marked by "g/kg DC" (Dry Content, e.g. 88.65 g/kg DC) also for the
printed results.
The moisture content of the sample is displayed (and printed out) as a
percentage of the wet weight (WW = initial weight = 100 %).
During the measurement the value is constantly displayed in percent and
as a graphical drying curve. The measured value is marked by "-%MC"
(Moisture Content, e.g. -11.35 -%MC) also for the printed results and
shown as a negative value.
Navigation: Home > Method Definition > Method name > Main measurement parameters > Start weight
The start weight affects both the duration of the measurement as well as the accuracy of the results. A small
weight results in a shorter duration of the measurement but will decrease the accuracy of the result. With this
function you can define a start weight so that the samples are approximately of equal weight thus improving the
repeatability of the measurements. The weighing-in aid assists you in weighing-in the sample. At most of the
samples the target weight is in the range of 2–5g (plastics 30g). We recommend to cover the whole surface
of the sample pan with a thin uniform layer of sample.
You can define the following parameters:
ParameterExplanationValues
Start weightDefines a start weight so that the samples always have approxi
mately the same weight .
Start weight tol
erance
Weigh-in aidDefines monitoring of target weight and tolerance.
Defines the tolerance of the Start weight.
10%, recommended for sample weights up to 5g.
Passive = tolerance is displayed.
Active = tolerance is monitored. If the startweight is out of toler
ance, the measurement cannot be started.
OFF* | ON
(0.100…200.000g)
1…25%
(10%)*
Passive*| Active
* Factory setting
85Method Definition
Page 86
8.2Result and Value Handling
Navigation: Home > Method Definition > Method name > Result and value handling
You can define the following parameters:
Menu itemExplanationFurther Information
Control limitsDefines the acceptable range for measuring results
in the unit of the selected display mode.
ResolutionDefines the readability of the built-in analytical bal
ance.
Free factorDefines a method-specific multiplication factor to
calculate a corrected final result.
8.2.1Control limits
Navigation: Home > Method Definition > Method name > Result and value handling > Control limits
With this function you can set warning and intervention limits for the quality and process monitoring. You can
also set limits for distinguish passed or failed.
You can define the following parameters:
ParameterExplanationValues
Control limitsDefines the acceptable range for the measuring results in the unit
of the selected display mode.
OFF = no limits applied.
T1+ (Upper
warning limit)
T1- (Lower
warning limit)
T2+ (Upper
intervention lim
it)
T2- (Lower
intervention lim
it)
* Factory setting
Defines the upper warning limit in the selected unit of the display
mode. Measurement passed with warning (!).
Value range in ATRO mode (%AD, %AM) up to 1000.
Defines the lower warning limit in the unit of the selected display
mode. Measurement passed with warning (!).
Value range in ATRO mode (%AD, %AM) up to 1000.
Defines the upper intervention limit in the unit of the selected dis
play mode. Measurement failed (X).
Value range in ATRO mode (%AD, %AM) up to 1000.
Defines the lower intervention limit in the unit of the selected dis
play mode. Measurement failed (X).
Value range in ATRO mode (%AD, %AM) up to 1000.
(✓)Measurement is within the warning limits: passed (displayed in green)
(!)Measurement is between the warning limits and the intervention limits: passed with warning (displayed
in yellow)
(X)Measurement is outside the intervention limit: failed (displayed in red)
Control limits is off = no limits applied (displayed in blue)
8.2.2Resolution
Navigation: Home > Method Definition > Method name > Result and value handling > Resolution
Traditionally, moisture analyzers are operated at a maximum resolution of 1mg / 0.01 %. The following set
ting allows you to determine moisture content using the resolution of the built-in analytical balance, which is
ten times higher (0.1mg weight / 0.001% moisture). The high resolution is especially suitable for samples
with low moisture content (lower than 1%). Careful sample preparation is extremely important for these kind of
samples!
Note
High resolution is not available for the display mode ATRO moisture content or ATRO dry content, see Settings
of Display Mode (page82).
You can define the following parameters:
ParameterExplanationValues
ResolutionDefines the readability of the built-in analytical balance.Standard* | High
* Factory setting
87Method Definition
Page 88
8.2.3Free Factor
Navigation: Home > Method Definition > Method name > Result and value handling > Free factor
This function allows you to multiply the result by a method-specific factor in the selected display mode. Further
more, it allows you changing the result by an offset entry in the unit of the selected display mode. It is used to
calculate a corrected final result (e.g. in order to compensate for systematic deviations from the reference
result).
Note
●
Free factor is not available in display mode "g" (weight).
●
The calculation is carried out continuously during the measurement and displayed with the graphical drying
curve.
●
With free factor, the results are calculated and marked with an asterisk in the display.
You can define the following parameters:
ParameterExplanationValues
Free factorDefines the settings for free factor.
FactorDefines the multiplication factor.-10.000…+10.000
OffsetDefines the offset value in the selected display mode.-1000.000…
FormatDefines the number of decimal places of the calculated final
* Factory setting
OFF* | ON
OFF = no free factor applied.
(1.000)*
+1000.000
(0.000)*
x | x.x | x .xx | x.xxx*
results, for displaying and printing.
88Method Definition
Page 89
8.3Workflow Handling
Navigation: Home > Method Definition > Method name > Workflow handling
With this functions you can define the workflow for the measurement
You can define the following parameters:
Menu itemExplanationFurther Information
Starting modeDefines how the sample chamber is operated.see Starting Mode (page89)
PreheatingDefines the settings for preheating the sample
chamber before starting the measurement.
8.3.1Starting Mode
Navigation: Home > Method Definition > Method name > Workflow handling > Starting mode
In this menu item you can choose whether the sample chamber should operate automatically or manually (e.g.
tare, stop drying).
You can define the following parameters:
ParameterExplanationValues
Starting modeDefines how the sample chamber is operated.Automatic*|
* Factory setting
Automatic
Your instrument is set in the factory to the automatic operating mode. This mode can be used for most kind of
samples. When closing the sample chamber, the weight of the sample is recorded and the measurement is
started.
see Preheating (page89)
Manual
Manual
We advise you to use the manual operating mode for samples which contain readily volatile substances. In
contrast to the automatic operating mode, in the manual operating mode the sample chamber does not auto
matically close when the [Start drying] button is tapped. However, the initial weight (wet weight) important for
the determination of the moisture content is recorded. In the manual operating mode you have time for further
preparation of the sample (e.g. mixing with quartz sand or even distribution of the sample) while weight losses
due to evaporation during the preparation time are measured from the outset. As soon as the sample is ready
for drying, press [ ] key. The automatic sample chamber closes and drying starts. In the manual operating
mode you can open the sample chamber during a drying operation. In contrast to the automatic mode, drying
will not be stopped but simply interrupted until the automatic sample chamber is closed again.
8.3.2Preheating
Navigation: Home > Method Definition > Method name > Workflow handling > Preheating
If necessary, you can activate preheating function to preheat the sample chamber. Because of the short heat-up
times with halogen moisture analyzers, no preheating is usually required for standard applications. A preheated
instrument can improve the reproducibility and accuracy of the results, since the instrument is in the same cli
matic state with every measurement. Preheating will only executed until time of measurement (Manual), in
standby mode even after the measurement.
You can define the following parameters:
ParameterExplanationValues
PreheatingDefines the settings for preheating the sample chamber (standby
temperature) before starting the measurement.
OFF = no preheating applied.
OFF* | ON |
Manual |
Standby
* Factory setting
89Method Definition
Page 90
Manual
Before a measurement can be started, the instrument prompts the user to activate the function preheating. The
instrument indicates, when it is enough preheated to start the measurement. The measurement can also be per
formed during the preheating phase by tapping Stop preheating. In this case, the duration of preheating will be
recorded. After a maximal preheating time of 1 hour, preheat will be off.
You can define the following parameters:
ParameterExplanationValues
TemperatureDefines the standby temperature.40…100°C
(40°C)*
* Factory setting
Standby
The instrument indicates, when it is enough preheated to start the measurement. The measurement can also be
performed during the preheating phase by tapping Stop drying. In this case, the duration of preheating will be
recorded.
The function Duration allows you to deactivate preheating at a preselected time period after measurement. The
feature Turn-off time allows to disable preheating at a defined clock time.
You can define the following parameters:
ParameterExplanationValues
TemperatureDefines the standby temperature.40…100°C
(40°C)*
DurationDefines the time which the instrument is maintained at standby
temperature for a limited amount of time after measurement (time
out).
Turn-off timeDefines the clock time at which Preheating will be off.OFF* | Hours : Minutes
* Factory setting
Hours | Minutes
(3 h)*
90Method Definition
Page 91
8.4General Method Properties
Navigation: Home > Method Definition > Method name > General method properties
8.4.1Method name
Navigation: Home > Method Definition > Method name > General method properties > Method name
You can define the following parameters:
ParameterExplanationValues
Method nameRenaming a method. Name should be unique and unambiguous. any
91Method Definition
Page 92
8.5Testing Methods
0 1 2 3 4 5 6 7 8 9 10 11
t
MC (%)
0
5
10
15
20
1
2
4
5
3
8.5.1Testing a Method
Test a method
This function allows you to test the settings during the definition phase of a method. Testing is possible at any
time. Test measurements are recorded in the journal and marked as test results. If you wish to work with the
switch-off criterion «weight loss per unit of time» and are not familiar with the behavior of the sample, the test
measurement will help you select the suitable setting. For more information about switch-off criteria, see Set
tings of Switch-off Criterion (SOC) (page80).
The diagram illustrates the progress of a
drying. The points at which the individual
switch-off criteria were reached (1-5) are
marked.
During this measurement, the measured values are recorded the switch-off criteria 1 to 5 and maybe one of a
free-defined switch-off criterion. The measurement terminates after the defined time (default 30minutes). Note
that the start weight affects the switch-off criterion. The test time can also be switched off. In this case the mea
surement terminates after reaching the predefined switch-off criterion. Nevertheless, all switch-off criteria are
recorded.
By comparing the measured values with values of a reference method e.g. drying oven and the standard devia
tion, you can define the appropriate parameter settings. For more information see the application brochure
«Guide to Moisture Analysis».
Carry out all measurements under Home > Method Definition > Method name > Tests before releasing a
method. The results of test measurements are specifically marked.
Attention
Before releasing the method, check if the determined switch-off criterion is set.
Performing a Test measurement
You perform a test measurement just like any other measurement. How to perform the measurement see Mea
surement (page94).
Changing the test time
Work screen for testing is displayed.
1 Tap Test time in the work screen.
Test time in min appears.
2 Confirm with OK.
Displaying the parameter
Work screen for testing is displayed.
– Tap the parameter in the work screen.
The parameter list appears.
Printing results of the determined switch-off criteria
For a printout example , See Information on Printouts (page101) section «Special events».
92Method Definition
Page 93
Displaying results of the determined switch-off criteria
See Graphical Evaluations of Measurement Results (page99)
8.5.2Testing with AutoMet
AutoMet test measurement helps you to save time when developing methods. It also enables you to octain a
result with your Moisture Analyzer that corresponds most closely to the reference value for the chosen tempera
ture and sample quantity.
With this function you can use the AutoMet button to enter the reference value and the instrument automatically
establishes an appropriate switch-off criterion for the defined method. This will be the point at which the mea
surement most accurately matches the reference value. This is the free switch-off criterion Free (mg / s).... The
AutoMet test measurement only proposes the switch-off criterion Free (mg / s)... if the drying trend means you
can expect a precise moisture determination. The range for the switch-off criterion Free (mg / s)... is therefore
limited to between 1mg/20 seconds and 1mg/140 seconds.
Note
If the target value is reached but the switch-off criterion is still outside 1mg/20-140 seconds, you have not
selected the optimum temperature. If Free (mg / s)... is below 1mg/20 seconds, reduce the temperature. If
Free (mg / s)... is above 1mg/140 seconds, either switch-off criterion 5 will provide a good approximation or
it might be a good idea to increase the drying temperature. If the target value is not reached, increasing the dry
ing temperature may obtain the desired result.
Performing a test with AutoMet
1 Perform a test measurement with the same sample as for the reference measurement.
2 Tap [AutoMet].
3 Enter Measurement reference in display unit (target value) and tap [OK].
AutoMet suggests you an appropriate switch-off criterion for the temperature selected or gives further
instructions on the display.
4 Tap [Save] to assume this switch-off criterion into the method.
93Method Definition
Page 94
9Measurement
This function offers you to perform a measuring using previously defined methods. After choosing the measure
ment method, the measurement process can be started. The work screen guides you step by step through the
measuring process.
The following functions are available:
●
On the work screen, you can create a shortcut. This allows you to start a method directly from the home
screen.
See Using Shortcuts (page97).
●
After completion of a measuring you can perform a further measuring with same method by tapping [Next
Sample] or with an other method by tapping [Measurement].
●
For graphical evaluations of measurement results tap [Results]. If you have defined the control limits in the
method, passed, warned or failed status is shown.
See Results (page99)
●
A detailed overview of the method parameter can you call up by tapping the parameter panel.
See Work Screen (page22).
See also
●
Using Shortcuts (page97)
●
Results (page99)
●
Work Screen (page22)
9.1Performing a Measurement
You are now familiar with all the parameters of your instrument and have defined all values for your sample.
The instrument is now ready for the determination of your samples. In this Section you will learn how to perform
measurements and how to stop the measurement process.
Switching on
The instrument must be connected to the power supply for approxi
mately 60 minutes in order to reach operating conditions.
1 To switch on the Instrument, press [ ].
2 Log-in with your password, if needed.
Selecting method for measurement
1 Tap Measurement.
The methods list is displayed.
2 Select the method to determine your sample.
The work screen of the method appears.
The sample chamber opens automatically.
94Method Definition
Page 95
Placing sample pan
#
The display now prompts you to load the empty sample pan and
tare the balance.
1 Place the empty sample pan in the sample pan handler.
2 Place the sample pan handler in the sample chamber. Ensure that
the tongue of the pan handler fits exactly in the slot of the draft
shield element. The sample pan must lie flat in the pan holder.
Note
We advise you to work with the sample pan handler at all times. The
pan handler is ergonomic, automatic positioning, safe and provides
protection against possible burns due to the hot sample pan.
Taring balance
– Tap [->0/T<-].
The sample chamber closes automatically for taring.
When taring is completed, the sample chamber opens auto
matically.
Starting measurement
After taring, the display prompts you to add the sample to the sam
ple pan.
1 Add the sample to the sample pan. If you have defined a start
weight, weigh the sample using the weighing-in aid.
2 Tap [Start drying].
The sample chamber closes automatically.
The drying process starts automatically.
Drying process
You can follow the measurement process on the display, see Work Screen (page22).
●
The drying process is continuously displayed graphically.
●
The current temperature in the heating module is displayed as well as the elapsed drying time and the cur
rent drying value.
●
The display shows the selected settings.
●
The drying process can be aborted by tapping [Stop drying].
At the end of the drying process you can read the moisture content of your sample on the display. If you have
defined the control limits in the method, passed, warned or failed status is shown.
Removing Sample
CAUTION
Danger of burns
Sample, sample pan and sample pan holder may still be hot.
95Measurement
Page 96
The drying process is completed.
The sample chamber is open (opens automatically).
1 Carefully remove the sample pan handler from the sample cham
ber.
Note
To remove the sample pan from the handler, lift the pan slightly
from below and remove it from the handler.
2 • To perform a further measurement with the current method, tap
[Next Sample].
• To perform a measurement with a new method, tap [Measurement].
• To return to the home screen, press [ ].
Stop drying
When you stop the measuring process by tapping [Stop drying], you can chose between two possibilities:
●
Abort without saving
Abort without saving of any data collected until now.
●
Abort measurement and save data
Already sampled data are stored and an entry will be made in the results. The result is marked as aborted.
Adding a comment
At the end of a measurement you can add a comment to the result of the measurement. This comment is stored
in the measurement result and can be printed. A comment can only be entered before leaving the current mea
surement.
1 To create a comment, tap [Note].
The keyboard dialog appears.
2 Enter a comment.
3 Confirm with [OK].
9.2Work with Weighing-in Aid
The weighing-in aid can be defined for each method and facilitates weighing in of the sample to a target value.
This is particularly necessary if you require all the samples of a method you wish to process to have same
weight in order to improve the repeatability of the measurement results. In addition, the weighing-in aid can be
set as active so that the drying process cannot be started if the weight of sample is outside the set tolerance.
You are therefore compelled to weigh-in the correct quantity of sample. If all sample weighed are within toler
ances then this will improve the repeatability. The weighing-in aid is available only if start weight has been acti
vated. For further information see Settings of Start Weight (page85).
IconFunction
Lower weight limit (tolerance range)
Target weight
96Measurement
Page 97
IconFunction
9.3Using Shortcuts
Navigation for managing shortcuts: Home > Measurement > Method name > [ ]
Shortcuts allow you to start methods directly from the home screen. Shortcuts are user-specific, i.e. each indi
vidual user can have his own shortcuts for the most common tasks.
You can define the following parameters:
ParameterExplanationValues
Shortcut nameDefines a name for the shortcut. It is recommended to choose a
Method nameShows the name of the method. The name of the method is the
Defining a shortcut
Menu Measurement is activated.
The method is selected.
1 Tap [ ].
Window My shortcuts appears.
2 Tap Add a shortcut to my home for this method.... (To abort, tap [X].)
New shortcut appears.
3 To enter a name for the shortcut if needed, tap Shortcut name.
Note
It is recommended to choose a short name because only approx. 8 characters are displayed on the short
cut. Name should be unique and unambiguous.
4 Confirm with [OK].
5 To store the setting, tap [Save].
To abort, tap [Cancel].
The shortcut is added to the home screen.
Upper weight limit (tolerance range)
any
short name because only approx. 8 characters are displayed on
the shortcut. Name should be unique and unambiguous.
none
target of the shortcut and can not be changed.
Editing a shortcut
The method is selected.
1 Tap [ ].
Window My shortcuts appears.
2 Tap Edit this shortcut.... (To abort tap [X].)
Shortcut properties appears.
3 To edit the name of the shortcut, tap Shortcut name.
4 Confirm with [OK].
5 To store the setting, tap [Save].
To abort, tap [Cancel].
Removing a shortcut
The method is selected.
1 Tap [ ].
Window My shortcuts appears.
97Measurement
Page 98
2 Tap Edit this shortcut.... (To abort, tap [X].)
Shortcut properties appears.
3 To remove the shortcut, tap [Remove].
A message window appears.
4 Confirm with [Remove]. (To abort, tap [Cancel].)
The shortcut is removed from the home screen.
98Measurement
Page 99
10Results
1
2
3
4
5a
5b
Test measurement
10.1Graphical Evaluations of Measurement Results
Navigation: Home > Results
This function allows you to manage and evaluate measurement results.
99Results
Page 100
1 Method list
– Tap the method you want to evaluate.
The journal view appears.
2 Journal view
The journal view allows you to start different graphical evaluations from a measurement series. You can per
form the following functions:
– To start filter function, tap [ ].
The filter menu appears.
– To start chart view, tap [Chart].
The chart view of the series of measurement appears (4).
– To start graphic view, tap a measurement result.
The graphic view appears (5).
3 Filter menu
The filter function allows you to evaluate the measurement series according to various criteria. You can select
the following criteria:
●
All (No filter)
●
Today
●
This week
●
Date range (Begin - End)
●
Last 10 measurements / tests*
●
Last 20 measurements / tests
– Tap [X] to close filter menu.
* Factory setting
4 Chart view
This view allows you to display the results of a series of measurements depending on the filter settings. If you
have defined the control limits in the method, they are diagramed in the results.
The marked measuring point is displayed with date, time, and the measurement result. You can perform fol
lowing functions:
– To jump forward to the next measurement result, tap [ -> ].
– To jump backwards to the previous measurement result, tap [ <- ]. Alternatively, tap directly on the desired
measurement point.
– To recall the full measurement curve of the corresponding measurement, tap [ ].
5a Graphics view
With this function you can display a graphical view of the detailed results of a single measurement. If you have
defined the control limits in the method, passed, warned or failed status is shown, see Control limits
(page86).
You can perform the following functions:
Printing result
– To print the result, tap [ ].
Exporting result
– To export the result, tap [Export].
See Exporting Results (page103).
100Results
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.