Metso Ball Valves Maintance Manual

Ball Valves with Up-Stream Vent Hole in Ball for Hydrogen Peroxide Service
Installation, Maintenance and Operating Instructions
IMO-PX2 EN • 11/2017
2 IMO-PX2 EN
TABLE OF CONTENTS
1. GENERAL .................................................................. 3
4. SERVICE / SPARE PART ............................................. 4
IMO 11/17
READ THESE INSTRUCTIONS FIRST!
These instructions provide information about safe handling and operation of the valve. If you require additional assistance, please contact the manufacturer or manufacturer’s representative. Addresses and phone numbers are printed on the back cover. See also www.metso.com/valves for the latest documentation.
SAVE THESE INSTRUCTIONS!
IMO-PX2 EN 3
1. GENERAL
This instruction manual contains important information regarding the installation, operation and troubleshooting of the Jamesbury® Ball Valves with Up-Stream Vent Hole in Ball for Hydrogen Peroxide Service. Please read these instructions carefully and save them for future reference.
WARNING:
FOR YOUR SAFETY, IT IS IMPORTANT THAT THE FOLLOWING PRECAUTIONS BE TAKEN PRIOR TO REMOVAL OF THE VALVE FROM THE LINE OR BEFORE ANY DISASSEMBLY.
1. WEAR ANY PROTECTIVE EQUIPMENT NORMALLY REQUIRED WHEN WORKING WITH THE FLUID INVOLVED DURING REMOVAL AND DISASSEMBLY TO PROTECT AGAINST ANY SPRAY OF TRAPPED HYDROGEN PEROXIDE.
2. DEPRESSURIZE THE LINE AND VALVE AS FOLLOWS:
A. SHUT OFF THE VALVE AND BLEED THE LINE.
B. CYCLE THE VALVE TO RELIEVE RESIDUAL PRESSURE BEFORE
REMOVAL FROM THE LINE..
C. AFTER REMOVAL CYCLE THE VALVE AGAIN SEVERAL TIMES.
104. These valves are designed to prevent hydrogen peroxide entrapment and decomposition which could cause explosive pressure build-up. All wetted surfaces are completely machined and venting ports are included to prevent media entrapment in the body. Each valve is factory cleaned to remove dirt or uid that might react with the media, and only compatible lubricants are used during manufacture.
NOTE: Hydrogen peroxide valves must be passivated before use. Valves are not passivated before shipment.
3. INSTALLATION
1. Before installation of any valve into a pipeline, factory­attached tags should be checked to assure that the valve is identied as having been processed for hydrogen peroxide service and that the valve type and material conform to requirements of the service intended. VALVE MUST BE PASSIVATED BEFORE INSTALLATION.
2. Standard piping practices should be followed during valve installation. Screwed end valves should be tightened by wrenching at the hex ats nearest the pipe being attached. Flanged valve bolts must be tightened to recommendations given by the manufacturer of the particular type of gaskets being used.
2. DESCRIPTION
Jamesbury valves with a vent hole in the ball for hydrogen peroxide service are available in both screwed and anged ends, in either all stainless steel components or in aluminum bodies with stainless steel balls and stems. Material grades are in accordance with FMC recommendations, Bulletin
3. With the valve in the closed position with the handle or actuator mounted, check the orientation of the ball and ow arrow. Compare with (Figure 1). Correct any misorientation by removing the handle or actuator rotating the ball 180 degrees and reinstalling the handle or actuator.
IMO 11/17
4 IMO-PX2 EN
4. SERVICE / SPARE PART
We recommend that valves be directed to our service cen­ters for maintenance. The service centers are equipped to provide rapid turn-around at a reasonable cost and oer new valve warranty with all reconditioned valves.
NOTE: When sending goods to the service center for repair, do not disassemble them. Clean the valve carefully and ush the valve internals. Include the material safety data­sheet(s) (MSDS) for all media owing through the valve. Valves sent to the service center without MSDS datasheet(s)
CORRECT
INCORRECT
will not be accepted.
Figure 1
NOTE: When ordering spare parts, always include the fol­lowing information:
a. Valve catalog code from identication plate,
b. If the valve is serialized – the serial number (from
identication plate),
c. From exploded view, the ballooned part number,
part name and quantity required.
Subject to change without prior notice.
Metso Flow Control Inc.
Europe, Vanha Porvoontie 229, P.O. Box 304, FI-01301 Vantaa, Finland. Tel. +358 20 483 150. Fax +358 20 483 151
North America, 44 Bowditch Drive, P. O. Box 8044, Shrewsbury, M A 01545, USA. Tel. +1 508 852 0200. Fax +1 508 852 8172
South America, Av. Independéncia, 2500-Iporanga, 18087-101, Sorocaba-São Paulo, Brazil. Tel. +55 15 2102 9700. Fax +55 15 2102 9748
China, 11/F, China Youth Plaza, No.19 North Rd of East 3rd Ring Rd, Chaoyang District, Beijing 100020, China. Tel. +86 10 6566 6600. Fax +86 10 6566 2583
Middle East, Roundabout 8, Unit AB-07, P. O. Box 17175, Jebel Ali Freezone, Dubai, United Arab Emirates. Tel. +971 4 883 6974. Fax +971 4 883 6836
Asia Pacic, 238B Thomson Road, #17-01 Novena Square Tower B, Singapore 307685. Tel. +65 6511 1011. Fax +65 6250 0830
www.metso.com/valves
Loading...