Metro C5 9 User Manual

Page 1
Item # _____________________________________
Job _______________________________________
Metro C5 9 Series Controlled Humidity Heated Holding and Proofing Cabinet
• Control: The intuitive 9 Series solid state controller provides
continuous monitoring of both temperature and humidity, providing accurate control over the internal environment of the cabinet, resulting in better food quality. Actual temperature and relative humidity are measured, displayed, and controlled.
• Performance: Rapid heat-up and recovery times, and precise
humidity control, are achieved with a digitally controlled dual­element ducted heating and humidity system. Intelligent power distribution maximizes efficiency and assures food is held at the desired temperature. Low water sensor and low temperature alarm assure cabinet is performing safely.
• Temperature Priority: The C5 9 Series controller prioritizes heat
generation over humidity generation assuring the cabinet holds food at the desired temperature, promoting food safety.
• Configurations:
• Sizes: Full Height, 3/4 Height, 1/2 Height, and Under Counter.
• Doors: Full Length Solid, Full Length Clear, Dutch Solid, Dutch Clear. All are lift off and field reversible.
• Reach-In or Pass-Thru (not available on under counter).
• Materials: Stainless Steel and Aluminum.
• Capacity: Universal slides hold 18"x26" sheet pans or 12"x20"
steam table pans on adjustable 1 hold 18"x26" sheet pans on 1 interfaces with universal slide system to accommodate small items and pans.
• Reliability: Reliability and durability are designed into C5 from
the ground up. High-quality components and robust construction provide a long life of service and worry-free use.
• Top-Mounted Controls: Ergonomic user-friendly controls are
mounted at the top of the cabinet for easier access, better readability, to prevent damage, and to simplify cleaning.
• NAFEM Data Protocol: The C5 controller is NDP capable.
• Energy Star: Full Height,
Energy Star.
1
/2" increments. Lip load slides
1
/2" increments. Optional Wire Shelf
3
/4 Height, and 1/2 Height models are
Under Counter
Full Solid Door
1
/2 Height
Full Clear Door
3
/4 Height
Full Solid Door
Full Height
Dutch Clear Doors
Full Height Dutch Solid Doors
Full Height
Full Solid Door
Metro C5 9 Series Controlled Humidity Heated Holding and Proofing Cabinet
9 Series Controller:
cabinet temperature
• Intuitive: Easy-to-use controls that anyone
can understand.
• Humidity: Measures and displays actual
cabinet relative humidity.
• Temperature Priority: 9 Series controller
generates heat before humidity for food safety.
• Low-Water Alarm: A safety feature that
indicates when water is needed. Water element will not be energized when water is low.
• Low-Temp Alarm: Assures cabinet is operating
at desired temperature.
• Recall & Memory: View settings at the touch of
a button. Settings are saved when turned off.
*Patents Pending
InterMetro Industries Corporation
North Washington Street Wilkes-Barre, PA 18705 www.metro.com
13.99
Page 2
Reach-In Model Number Description
Low Watt Model Number Description
Models with Accessories or Options
Add “L” for Lower Wattage Cabinets (120V, 12A, 60Hz, 1440W)
Add “X” for Export Cabinets (220-240V, 7.6-8.3A, 50/60Hz, 1681-2000W)
NEMA 6-15P
NEMA 5-15P
C5
9 9
--
L
S DSPU
DS
C5
9 9
S DS U
C5
9 9
-
-
S DS U
Pass-Thru Model Number Description
Export Model Number Description
- -
X
C5
9 9
S DS U
- -
For Standard Wattage Cabinets (120V, 16A, 60Hz, 2000W)
NEMA 5-20P
Door Style FS = Full Length Solid FC = Full Length Clear DS = Dutch Solid * DC = Dutch Clear *
Cabinet Height 9 = Full Height 7 = 3/4 Height 5 = 1/2 Height 3 = Under Counter
Cabinet Material S = Stainless N = Aluminum
Slide Type U = Universal Wire L = Lip Load Aluminum
Pass Thru* Door Style
C5
9 9
-
-
S DSPU
DS
A
C5
9 9
-
-
S DSAU
An “A” suffix indicates that accessories need to be factory assembled to the cabinet. Order accessories separately.
G
W
*Please note: Pass-Thru is only available on Full Height,
3
/4 Height, and 1/2 Height Models.
*Please note: Dutch doors only available on full-size models.
Metro C5 9 Series Controlled Humidity Heated Holding and Proofing Cabinet
Specifications
13.99
Metro C5 9 Series Controlled Humidity Heated Holding and Proofing Cabinet
• Cabinet Material: Type 304 stainless steel; 20-gauge polished
exterior; 22-gauge interior, or .063" aluminum, brushed exterior, natural interior.
• Insulation: Full perimeter, 1" thick, high-density fiberglass.
R Value=4.2
• Casters: Four casters with 5" donut neoprene wheel, double ball
bearing swivel, ball bearing axle, nickel plated, two with brake. 3" rubber casters on Under Counter models.
• Doors:
• Solid doors are fully insulated, double-panel construction.
• Clear doors are double-pane, tempered glass. Argon filled with Low-E coating.
• Hinges: Self-closing, lift-off, double hinged, with long-life
nylon bearings.
• Gaskets: High temperature, cabinet mounted, Santoprene gaskets.
• Latches: Chrome plated, high-strength magnetic pull latch with
lever-action release.
• Handles: Four built-in polymer handles.
• Universal Slides: Universal wire slides;
wire adjustable on 1 steel vertical standards.
• Lip Load Slides: 1
on .063" aluminum vertical standards.
• Slide Capacities:
Universal Slides Slide Pairs Pan Capacity** Pan Capacity
Cabinet Size Provided Max.* 18"x26" 12"x20"x21/2" 18"x26"
Full Height 18 37 18 36 36 Full Height/Dutch 18 35 17 34 35
3
/4 Height 14 29 14 28 29
1
/2 Height 8 17 8 16 17
Under Counter 5 10 5 10 10
*Maximum number of slide pairs @ 11/2" spacing. Additional slide pairs ordered separately. **Capacity based on standard number of slide pairs provided on 3" spacing.
• Bumper/Drip Trough: Non-marking polymer bumper and drip
trough combination.
• Display and Controls: Actual cabinet temperature and relative
humidity display with individual control dials for each.
• Heat Generation System: Thermostatically controlled closed loop
feedback with 1950 Watt heating element, ball bearing blower motor, and ducted air system. Low temperature alarm enable/disable.
• Cord: 7
3
• Humidity Generation System: Closed loop controlled 1950 Watt
heating element with ducted air system, low water sensor, and 4
1
/2' cord with NEMA 5-20P plug. Cord mounted on top (Full,
/4, Pass Thru) or back (1/2, Under Counter) can be field reversed.
gallon water reservoir (filled to
• Thermal Performance: 200
• Humidity Performance: Up to 95% RH at 100
o
160
F, or 75% RH at 200o F (Full-Height model).
• Minimum Clearances for Enclosures: 1
and 3" on back is provided by built in bumper. 6" clearance is required on top.
• Dimensions:
All Metro Catalog Sheets are available on our Web Site: www.metro.com
74.75"
Full Height
1
/2" increments. 16-gauge, Type 304, stainless
1
/2"x1/2"x.063" extruded aluminum channel slides
62.75"
3
/4 Height
InterMetro Industries Corporation
North Washington Street, Wilkes-Barre, PA 18705 Phone: 570-825-2741 • Fax: 570-825-2852
For Product Information Call: 1-800-433-2232
1
/4" diameter nickel-chrome
1
/2" from top) with drain.
o
F maximum temperature.
All cabinets are 30" wide and 34" deep
44.75"
1
/2 Height
o
F, 90% RH at
1
/2" clearance on sides
32.25"
Under Counter Height
Lip Load Slide
Available Accessories:
• Flush Latch Handle (C5-LATCHFLUSH) *
• Twist Locking Handle (C5-LATCHTWST) *
• Key Locking Latch Handle (C5-LATCHLOCK) *
• Stainless Steel Handles (C5-HANDLE)
• Twist Lock Plug (C5-RTWSTPLG)
• Right Angle (P-Style) Plug (C5-RTANGPLG)
• Control Panel Cover (C5-COVER)
• 5" Rear Rigid Casters (C5-5RDGCSTR)
• 6" Casters (C5-6CASTER)
1
/2
• 6" Stainless Steel Legs (C5-SSLEGS)
• Chrome Universal Slide Pair (C5-USLIDECPR)
• Stainless Steel Universal Slide Pair (C5-USLIDESPR)
• Stainless Steel Universal Slide Upgrades
• Full Height (C5-SSUSLIDE-9)
• 3/4 Height (C5-SSUSLIDE-7)
• 1/2 Height (C5-SSUSLIDE-5)
• Under Counter (C5-SSUSLIDE-3)
• Small Item Shelf (C5-SHELF)
• Drain Hose Adapter (C5-HOSEADPT)
• Factory Left-Hand Hinging (DD3768)
• Factory Same-Side Pass-Thru Door Hinging (C5-SAMESIDE)
*Please note: (1) handle must be ordered for each door (i.e. — dutch
doors require (2) handles; pass-thru dutch doors require (4) handles)
Metro Heated cabinets are for
hot food holding applications only.
Printed in U.S.A. Rev. 11/08
Information and specifications are subject to change
without notice. Please confirm at time of order.
Copyright © 2008 InterMetro Industries Corp.