1 Introduction
1.1 General Description
Demonstration board simulates typical electrical installation usually met in individual
houses or apartments. This board is to be used preferably by sales personnel when
demonstrating operation of electrical installation test equipment, especially the new
Metrel’s electrically installations safety testers with built in Autosequencer.
The board is placed into plastic carrying case. The board contains real elements of
electrical installation like RCD, mains switch, automatic fuses, switches, lamps, 1-phase
and 3-phase mains test outlet, N and PE collector.
TN or TT system can be simulated.
Demonstration board is constructed according to European safety standard EN 61010-1.
1.2 General warnings
• Connect Demonstration board to outlets with well grounded protection
terminal only! Line impedance (ZLN) of outlet must be less than 1 Ω!
• If Demonstration board is not used in a manner specified by manufacturer,
the protection provided by the equipment may be impaired.
• Only qualified personnel who are familiar with the board and related
installation testers can work with the Demonstration board!
• Do not use Demonstration board in case of any damage noticed!
• Only an authorised person may carry out servicing of Demonstration
board!
• Use carefully the Demonstration board to avoid electric shock. Mains
voltage is present on it in the same manner as in the real switchboards.
• 1- and 3-phase outlets are intended for demonstration purposes only.
Never use other equipment than installation testers.
• Never touch metal tip of test probes or put fingers over protection barrier.
See the figure below
Barrier
Correct and safety
4
Wrong and
Hazardous live
MI 3099 Demonstration board
1.3 Meaning of front panel warnings
Take care. Demonstration board operates only at
declared mains voltages (according to the description
under the mains socket) and right connected mains
terminals!
Use only outlets with grounded protection terminal!
There is a protection circuit inside the board. The
board will not turn on:
− if PE terminal is not grounded
− if N terminal is not connected
if phase voltage is not applied to the boards L
−
1-phase connection: The board will turn on if mains
plug is inserted correctly. Otherwise swap L and N
terminals!
terminal. Swap the mains plug in this case.
− if there is a voltage difference higher than 30V
between N and PE terminals.
Use the test outlets on front panel only for
demonstration purposes!
Do not connect any other equipment/loads, otherwise
the board may be damaged and the operator exposed
to hazardous voltage!
Do not connect any external voltage except voltages
generated by measuring instruments – possible
hazardous voltage on accessible parts of board.
PE terminals collectors and N terminals collectors are
NOT connected to mains PE terminal but to neutral
line.
5
MI 3099 Demonstration board
345
2 Front panel and mains cable description
2.1 Front panel
1
2
6
7
8
1112
Legend:
1........Mains connector. For connection to mains voltage via belonging mains cable.
For connection to 1-phase system use the 1-phase to 3-phase adapter
2........Main switch.
3........RCD protection device. It can be by passed with rotary switch (position 6)
4........N - collector.
5........PE - collector.
6........Rotary switch for by-passing of the RCD.
⇒ RCD is included
⇒ RCD is by-passed
7........3-phase socket.
8........1-phase socket
9........Switches for loads (lamps)
10......Loads (lamps)
11......Automatic fuses
12......Jumper for selection of TN-C(S) or TT system
10
9
6
MI 3099 Demonstration board
N
E
2.2 Mains cable 3-phase
L3
L1
L2
P
3 Technical data
Nominal mains voltage ..............................230 V / 400 V (STAR connection) / 50 Hz
Power consumption ................................... 7 W
Reference temperature range ................. 10 °C ÷ 30 °C
Reference humidity range ....................... 40 %RH ÷ 70 %RH
Operation conditions
Working temperature range ....................5 °C ÷ 40 °C
Maximum relative humidity...................... 95 %RH (5 °C ÷ 40 °C), non-condensing
4 Maintenance
4.1 Cleaning
Use a soft cloth slightly moistened with soapy water or alcohol to clean the surface of
the board and then leave the board to dry totally before use.
Do not use liquids based on petrol!
Do not spill liquids over the board!
7
MI 3099 Demonstration board
4.2 Service
In case of improper operation of Demonstration board or if there is any damage noticed,
the product has to be taken to an authorised service. Consult the producer or your
dealer for further information.
The product has no internal user serviceable parts (fuses, etc).
5 Standard set
Upon receipt of Demonstration board it is advisable to check the content of the delivery.
The following items have to be included:
• Demonstration board
• Jumper
• Tip probe (3 pcs)
• Mains cable (3-phase)
• Adapter 1-phase to 3-phase
• Instruction manual